Study guide

10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC

Key Takeaways Explain This Topic AI

Coliform bacteria serve as sanitary indicators for enteric pathogens; the Revised Total Coliform Rule (RTCR) enforces an absence/presence compliance standard in 100 mL drinking water samples.

The Defined Substrate Technology (Colilert) uses ONPG to detect total coliform (beta-galactosidase turns yellow) and MUG to detect E. coli (beta-glucuronidase fluoresces bright blue under 365 nm UV light).

Membrane filtration captures bacteria on 0.45 um cellulose ester grid filters; total coliforms produce distinct golden-green metallic sheen colonies on m-Endo agar at 35.0°C.

Fecal coliform membrane filtration utilizes m-FC medium incubated in a precision water bath at 44.5°C ± 0.2°C, yielding distinctive dark blue colonies.

Microbiological QA/QC requires positive controls (E. coli), negative controls (Pseudomonas aeruginosa), sterility blanks, and autoclave sterilization validation at 121°C (15 psi) for 15 minutes.

Last updated: August 2026

Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC

Waterborne pathogens—including bacterial agents ( Salmonella typhi , Shigella dysenteriae , Vibrio cholerae ), enteric viruses (Norovirus, Hepatitis A), and protozoan cysts ( Giardia lamblia , Cryptosporidium )—are difficult, expensive, and dangerous to isolate directly in water treatment laboratories. Consequently, regulatory programs under the Safe Drinking Water Act (SDWA) and the Revised Total Coliform Rule (RTCR) mandate the use of indicator organisms to evaluate the sanitary integrity of potable supplies and wastewater discharges.

1. Microbial Indicators & The Coliform Hierarchy

An ideal microbial indicator must be universally present in high numbers in the feces of warm-blooded mammals, survive longer in environmental water than enteric bacterial pathogens, exhibit comparable resistance to disinfection, and be rapidly quantifiable through standardized, reproducible laboratory assays. +---------------------------------------------------------------------------------------------------------+

  • | THE COLIFORM BACTERIAL HIERARCHY |
  • +---------------------------------------------------------------------------------------------------------+
  • | TOTAL COLIFORM GROUP (Broad Sanitary Indicator) |
  • | - Gram-negative, non-spore-forming, aerobic / facultatively anaerobic rods |
  • | - Ferment lactose with acid and gas production at 35.0°C ± 0.5°C within 24 to 48 hours |
  • | - Genera: Escherichia, Enterobacter, Klebsiella, Citrobacter (Found in feces, soil, and vegetation) |
  • | +---------------------------------------------------------------------------------------------------+ |
  • | | FECAL (THERMOTOLERANT) COLIFORMS | |
  • | | - Subset capable of lactose fermentation at elevated temperature of 44.5°C ± 0.2°C | |
  • | | - Primarily fecal origin; indicates potential wastewater contamination | |
  • | | +---------------------------------------------------------------------------------------------+ | |
  • | | | ESCHERICHIA COLI (E. COLI) | | |
  • | | | - Specific species within fecal coliform group (~97% produce enzyme beta-glucuronidase) | | |
  • | | | - Definitive, unambiguous proof of mammalian fecal contamination; triggers acute health boil| | |
  • | | | water advisories under RTCR | | |
  • | | +---------------------------------------------------------------------------------------------+ | |
  • | +---------------------------------------------------------------------------------------------------+ |
  • +---------------------------------------------------------------------------------------------------------+
  • Revised Total Coliform Rule (RTCR) Compliance Framework

Under CDPHE Regulation 11, public water systems collect distribution compliance samples based on population served (e.g., minimum 1 to 480+ samples/month). All compliance testing is performed on 100 mL 100\text{ mL} 100 mL sample volumes :

Maximum Contaminant Level Goal (MCLG): Zero ( 0 0 0 ) for E. coli and total coliform.

Presence/Absence (P/A) Determination: Any total coliform-positive sample triggers mandatory repeat sampling (within 24 hours: original tap, within 5 service connections upstream, within 5 connections downstream) and analysis for E. coli .

Treatment Technique Triggers: An E. coli positive repeat sample or coliform hits exceeding 5.0% of monthly samples triggers a mandatory Level 1 or Level 2 Sanitary Assessment across the distribution system.

2. Defined Substrate Technology: Colilert & Quanti-Tray Analysis

Defined Substrate Technology (DST) (EPA-approved Standard Methods 9223B / Colilert method) simultaneously detects and enumerates Total Coliforms and E. coli within 24 hours (or 18 hours for Colilert-18) without requiring secondary confirmatory broths.

Dual Biochemical Enzyme Mechanisms

The reagent medium supplies nutrient substrates linked to specific chromogenic and fluorogenic indicators as the sole carbon sources:

Total Coliform Detection via ONPG ( β -galactosidase \beta\text{-galactosidase} β -galactosidase ): All coliform bacteria express the enzyme β -D-galactosidase \beta\text{-D-galactosidase} β -D-galactosidase , which hydrolyzes the colorless substrate ONPG ( o -nitrophenyl- β -D-galactopyranoside o\text{-nitrophenyl-}\beta\text{-D-galactopyranoside} o -nitrophenyl- β -D-galactopyranoside ), releasing yellow o -nitrophenol o\text{-nitrophenol} o -nitrophenol . ONPG (Colorless) → β -galactosidase (Total Coliform) o -Nitrophenol (Distinct Yellow Color) \text{ONPG (Colorless)} \xrightarrow{\beta\text{-galactosidase (Total Coliform)}} o\text{-Nitrophenol (Distinct Yellow Color)} ONPG (Colorless) β -galactosidase (Total Coliform) ​ o -Nitrophenol (Distinct Yellow Color)

E. coli Detection via MUG ( β -glucuronidase \beta\text{-glucuronidase} β -glucuronidase ): Escherichia coli uniquely produces the intracellular enzyme β -D-glucuronidase \beta\text{-D-glucuronidase} β -D-glucuronidase (present in > 97 % > 97\% > 97% of strains). This enzyme hydrolyzes the fluorogenic substrate MUG ( 4 -methylumbelliferyl- β -D-glucuronide 4\text{-methylumbelliferyl-}\beta\text{-D-glucuronide} 4 -methylumbelliferyl- β -D-glucuronide ), releasing 4 -methylumbelliferone 4\text{-methylumbelliferone} 4 -methylumbelliferone . MUG (Colorless) → β -glucuronidase (E. coli) 4 -Methylumbelliferone (Fluoresces Blue under 365 nm UV) \text{MUG (Colorless)} \xrightarrow{\beta\text{-glucuronidase (E. coli)}} 4\text{-Methylumbelliferone (Fluoresces Blue under 365 nm UV)} MUG (Colorless) β -glucuronidase (E. coli) ​ 4 -Methylumbelliferone (Fluoresces Blue under 365 nm UV) Colilert Analytical Interpretation Summary:

  • Clear / Colorless Vessel: NEGATIVE for Total Coliform and E. coli
  • Yellow Vessel (Equal to or darker than Ref): POSITIVE for Total Coliform
  • Yellow + Bright Blue Fluorescence at 365 nm: POSITIVE for E. coli

Loading diagram... Defined Substrate (Colilert) Dual-Enzyme Analytical Pathway

Quanti-Tray Most Probable Number (MPN) Enumeration

When quantitative bacterial counts are required (e.g., surface water source characterization or wastewater discharge compliance), the 100 mL 100\text{ mL} 100 mL Colilert mixture is poured into a 51-well or 97-well Quanti-Tray and heat-sealed in an automated sealer. Trays are incubated at 35.0 ∘ C ± 0.5 ∘ C 35.0^\circ\text{C} \pm 0.5^\circ\text{C} 35. 0 ∘ C ± 0. 5 ∘ C for 24 hours .

Count the number of yellow wells (Total Coliform).

Count the number of yellow wells that fluoresce under a 365 nm 365\text{ nm} 365 nm ultraviolet lamp ( E. coli ).

Cross-reference the positive well counts with the standardized MPN Generating Table to establish the statistical Most Probable Number per 100 mL (MPN/100 mL) with 95% statistical confidence limits.

3. Membrane Filtration (MF) Methodology

Membrane Filtration (Standard Methods 9222) provides direct visual colony enumeration by passing a liquid sample through a sterile micro-porous membrane filter.

Equipment & Filtration Mechanics

Apparatus: Sterile magnetic filter funnel, vacuum flask, and vacuum pump ( < 25 in. Hg < 25\text{ in. Hg} < 25 in. Hg / ≈ 0.7 bar \approx 0.7\text{ bar} ≈ 0.7 bar to avoid cell lysis).

Membrane Filter: Sterile, gridded cellulose ester membrane disc, 47 mm 47\text{ mm} 47 mm diameter , with a calibrated 0.45 μ m 0.45\text{ }\mu\text{m} 0.45 μ m nominal pore size . Bacteria are physically retained on the grid surface. [ 100 mL Sample ]

  • |
  • v
  • +---------------------------+
  • | Sterile Magnetic Funnel |
  • +---------------------------+
  • | 0.45 um Gridded Membrane | <--- Bacteria Retained on Grid
  • +---------------------------+
  • |
  • v (Vacuum Filtration)
  • [ Filtrate ]
  • Analytical Protocols for Coliform Media

Total Coliform on m-Endo Medium (SM 9222B):

Place membrane on an absorbent pad saturated with m-Endo broth (or m-Endo agar) in a 50 mm 50\text{ mm} 50 mm Petri dish.

Invert dish and incubate at 35.0 ∘ C ± 0.5 ∘ C 35.0^\circ\text{C} \pm 0.5^\circ\text{C} 35. 0 ∘ C ± 0. 5 ∘ C for 24 ± 2 hours 24 \pm 2\text{ hours} 24 ± 2 hours .

Colony Appearance: Total coliform bacteria ferment lactose to produce acetaldehyde, which reacts with sodium sulfite and basic fuchsin to form red colonies with a distinctive golden-green metallic sheen .

Ideal Counting Range: 20 to 80 coliform colonies per membrane .

Fecal Coliform on m-FC Medium (SM 9222D):

Place membrane on m-FC broth containing rosolic acid inhibitor.

Seal Petri dishes in watertight plastic bags and submerge in a thermostatically controlled circulating water bath at 44.5 ∘ C ± 0.2 ∘ C 44.5^\circ\text{C} \pm 0.2^\circ\text{C} 44. 5 ∘ C ± 0. 2 ∘ C for 24 ± 2 hours 24 \pm 2\text{ hours} 24 ± 2 hours .

Colony Appearance: Fecal coliforms produce distinct blue colonies (non-fecal organisms appear gray or cream-colored).

Ideal Counting Range: 20 to 60 fecal coliform colonies per membrane .

Membrane Filtration Calculation Formula Coliform Colonies / 100 mL = Coliform Colonies Counted × 100 Sample Volume Filtered (mL) \text{Coliform Colonies / 100 mL} = \frac{\text{Coliform Colonies Counted} \times 100}{\text{Sample Volume Filtered (mL)}} Coliform Colonies / 100 mL = Sample Volume Filtered (mL) Coliform Colonies Counted × 100 ​

Worked Example 9.4.1: Membrane Filtration Fecal Coliform Calculation

A wastewater laboratory analyst filters a series of final effluent dilutions through 0.45 μ m 0.45\text{ }\mu\text{m} 0.45 μ m filters and incubates them on m-FC media in a 44.5 ∘ C 44.5^\circ\text{C} 44. 5 ∘ C water bath for 24 hours. The 10.0 mL 10.0\text{ mL} 10.0 mL sample volume produces 82 blue colonies (too numerous to count reliably), while the 5.0 mL 5.0\text{ mL} 5.0 mL volume produces 34 distinct blue colonies. Calculate the fecal coliform density per 100 mL 100\text{ mL} 100 mL .

Step 1: Select the statistically valid membrane: The ideal counting range on m-FC is 20 to 60 colonies. The 5.0 mL 5.0\text{ mL} 5.0 mL filter with 34 colonies is within the ideal range.

Step 2: Calculate density: Fecal Coliform / 100 mL = 34 colonies × 100 5.0 mL = 3,400 5.0 = 680 CFU / 100 mL \text{Fecal Coliform / 100 mL} = \frac{34\text{ colonies} \times 100}{5.0\text{ mL}} = \frac{3{,}400}{5.0} = 680\text{ CFU / 100 mL} Fecal Coliform / 100 mL = 5.0 mL 34 colonies × 100 ​ = 5.0 3 , 400 ​ = 680 CFU / 100 mL

4. Multiple Tube Fermentation (MTF) / MPN Method

Multiple Tube Fermentation (Standard Methods 9221) is the traditional statistical broth method, indispensable for highly turbid, colored, or clay-laden waters that would clog 0.45 μ m 0.45\text{ }\mu\text{m} 0.45 μ m membrane filters.

Presumptive Phase: Inoculate series of Lauryl Tryptose Broth (LTB) fermentation tubes containing inverted Durham vials. Incubate at 35.0 ∘ C ± 0.5 ∘ C 35.0^\circ\text{C} \pm 0.5^\circ\text{C} 35. 0 ∘ C ± 0. 5 ∘ C for 24 – 48 hours 24\text{--}48\text{ hours} 24 – 48 hours . Gas formation (bubble in Durham vial) and turbidity indicates a presumptive positive.

Confirmed Phase: Transfer an inoculum loop from positive LTB tubes into Brilliant Green Bile (BGB) 2% Lactose Broth (for Total Coliform at 35.0 ∘ C 35.0^\circ\text{C} 35. 0 ∘ C ) or EC Medium (submerged in a 44.5 ∘ C ± 0.2 ∘ C 44.5^\circ\text{C} \pm 0.2^\circ\text{C} 44. 5 ∘ C ± 0. 2 ∘ C water bath for Fecal Coliform). Gas within 24 to 48 hours confirms coliform presence.

Completed Phase: Streak positive confirmed tubes onto m-Endo agar and perform Gram staining (confirms Gram-negative, non-spore-forming bacilli).

5. Microbiological QA/QC & Laboratory Safety

Microbiological testing requires rigorous quality control to verify media sterility, specificity, and equipment performance.

Positive Culture Controls: Test each new lot of media with known bacterial strains: Escherichia coli (ATCC 25922, produces yellow ONPG and UV fluorescence) and Enterobacter aerogenes (produces yellow ONPG without fluorescence).

Negative Culture Controls: Test each lot with Pseudomonas aeruginosa (ATCC 27853) or Proteus vulgaris to verify that non-coliform bacteria do not produce false-positive reactions.

Sterility Blanks: Process sterile dilution water through the filtration apparatus at the start, middle, and end of every filtration series. Sterility blanks must yield zero ( 0 0 0 ) colonies.

Autoclave Sterilization Validation: Autoclave media, sample bottles, and biohazard waste at 121 ∘ C 121^\circ\text{C} 12 1 ∘ C ( 250 ∘ F 250^\circ\text{F} 25 0 ∘ F ) at 15 psi 15\text{ psi} 15 psi for a minimum of 15 minutes 15\text{ minutes} 15 minutes . Validate monthly with Geobacillus stearothermophilus spore ampoules.