Study guide

10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

Key Takeaways Explain This Topic AI

Total Kjeldahl nitrogen equals organic nitrogen plus ammonia nitrogen, and total nitrogen equals TKN plus nitrite plus nitrate.

Ammonia toxicity is driven by the un-ionized fraction, which increases sharply as pH and temperature rise.

Dissolved metals require filtration through a 0.45 micron filter before acid preservation, while total metals are preserved and digested without filtration.

Whole effluent toxicity failures trigger a toxicity identification evaluation and a toxicity reduction evaluation, and ammonia, chlorine residual, surfactants, and industrial metals are the usual causes.

Dissolved oxygen probes must be altitude corrected in Colorado, where saturation at 5,300 feet is roughly 83 percent of the sea-level value, and ORP distinguishes truly anoxic from truly anaerobic zones where a DO probe cannot.

Last updated: August 2026

The analytes a wastewater permit actually names

WPI's wastewater Laboratory Analysis outline requires operators to collect samples for, conduct, and interpret data from bacteriological analyses , biological analyses (BOD, CBOD, WET) , chemical analyses (COD, nutrients, metals) , and physical analyses (pH, temperature, DO, settleable solids) , and to operate and maintain instrumentation for DO, pH, H2S, and ORP . BOD, COD, and TSS are covered in the wastewater laboratory section; this section covers the nutrients, metals, toxicity, and electrode measurements that make up the rest of the list.

Nitrogen series

Nitrogen appears in wastewater in several forms, and each is separately meaningful.

  • Form What it is Significance
  • Organic nitrogen Nitrogen in proteins, urea, amino acids Hydrolyzes to ammonia

Ammonia nitrogen (NH3-N) Free ammonia plus ammonium Toxic to fish; exerts oxygen demand; the substrate for nitrification

Total Kjeldahl nitrogen (TKN) Organic nitrogen plus ammonia nitrogen The reduced nitrogen available for nitrification

Nitrite (NO2-N) Intermediate of nitrification Rising nitrite signals incomplete nitrification or nitrification in the distribution system

  • Nitrate (NO3-N) Fully oxidized nitrogen Denitrification substrate; drinking water MCL of 10 mg/L as N
  • Total nitrogen TKN plus nitrite plus nitrate The permit parameter under nutrient rules

Two relationships to carry: TKN equals organic nitrogen plus ammonia , and total nitrogen equals TKN plus nitrite plus nitrate . Also note that ammonia toxicity is driven by the un-ionized fraction , which increases sharply with rising pH and temperature — the same total ammonia concentration is far more toxic at pH 9 and 25 degrees Celsius than at pH 7 and 10 degrees.

Methods. Ammonia by ion selective electrode, salicylate or Nessler colorimetry, or distillation and titration. TKN by digestion followed by ammonia measurement. Nitrate and nitrite by cadmium reduction, ultraviolet absorption, or ion chromatography.

Phosphorus

Orthophosphate is the soluble, reactive, immediately available form and is what a chemical precipitation or EBPR process is controlled on.

Total phosphorus requires digestion to convert condensed and organic phosphorus to orthophosphate before measurement.

The standard colorimetric method is the ascorbic acid method, producing a blue complex read at 880 nanometers.

For process control, an operator commonly runs orthophosphate on a filtered sample to see what the biology or chemistry has actually removed, and reports total phosphorus on an unfiltered sample for compliance.

Metals

Metals reach a wastewater plant from industrial users, from corrosion, and from stormwater. They matter for three reasons: they can be toxic to the biological process , they are limited in biosolids under Regulation 64 and Part 503, and they may carry water-quality-based effluent limits .

Sample handling is where metals results are won or lost. Samples are collected in acid-washed containers and preserved with nitric acid to pH below 2 to keep metals in solution and off the container walls.

Total metals requires acid digestion of the sample; dissolved metals requires filtration through a 0.45 micron filter before preservation . Getting this order wrong is a common and invalidating error.

Methods are atomic absorption spectroscopy or inductively coupled plasma, which is why metals are sent to a laboratory rather than run at the plant.

Whole effluent toxicity

WET testing exposes test organisms — typically the water flea Ceriodaphnia dubia and the fathead minnow Pimephales promelas — to a series of effluent dilutions.

Acute tests measure survival over 24 to 96 hours and report an LC50 , the concentration lethal to 50 percent of organisms.

Chronic tests measure survival plus growth or reproduction over about 7 days and report a NOEC (no observed effect concentration) or an IC25 .

A failed test triggers a toxicity identification evaluation (TIE) to find the cause and a toxicity reduction evaluation (TRE) to fix it. At domestic plants the usual suspects are ammonia , residual chlorine , surfactants , and metals from an industrial user .

Sample handling matters enormously: WET samples are chilled, delivered fast, and, where chlorine is present, the residual is addressed per the method, because otherwise the test simply measures chlorine.

Electrode measurements

Measurement Instrument notes

Dissolved oxygen Membrane (Clark) probes consume oxygen and require flow across the membrane ; luminescent (optical) probes do not, and have largely replaced them. Calibrate in water-saturated air, and correct for altitude — a critical point in Colorado, where saturation at 5,300 feet is roughly 83 percent of the sea-level value

pH Two-point calibration bracketing the sample; slope 95 to 105 percent; store in KCl storage solution

ORP (oxidation-reduction potential) Reported in millivolts; used to identify aerobic, anoxic, and anaerobic zones in BNR. Strongly positive indicates aerobic, near zero to slightly negative indicates anoxic, and strongly negative indicates anaerobic and sulfide-forming conditions

Hydrogen sulfide Field colorimetric or ion selective electrode for liquid; fixed and personal gas detectors for the atmosphere

Temperature NIST-traceable verification, correction factor recorded

ORP is the most underused of these. Because a BNR process depends on maintaining genuinely anoxic conditions in the denitrification zone and genuinely anaerobic conditions in the phosphorus release zone, ORP tells the operator directly whether those zones are what they are supposed to be — something a dissolved oxygen probe reading zero cannot distinguish.

Loading diagram... Nutrient, Metals, Toxicity, and Electrode Measurements