10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques
Colorado Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: State Laws, Regulations & CCWP Certification
1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
2 Chapter 2: Source Water & Drinking Water Treatment Processes
2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle
3 Chapter 3: Disinfection & Chemical Addition
3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices
4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance
4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management
5 Chapter 5: Wastewater Treatment Principles & Biological Processes
5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects
6 Chapter 6: Advanced Wastewater Treatment & Solids Management
6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84
7 Chapter 7: Water Distribution Systems
7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems
8 Chapter 8: Wastewater Collection Systems
8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment
9 Chapter 9: Pumps, Motors & Utility Mechanics
9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control
10 Chapter 10: Laboratory Analysis & Water Quality Monitoring
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)
11 Chapter 11: Operator Mathematics & Applied Calculations
11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance
12 Chapter 12: Safety, Emergency Operations & Compliance
12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques
Key Takeaways Explain This Topic AI
Grab samples capture instantaneous stream conditions and are legally mandatory for transient parameters including pH, dissolved oxygen, temperature, residual chlorine, and fecal coliform.
Composite samples (time-weighted or flow-proportional) provide flow-averaged representations over 24 hours, required for regulatory BOD5, TSS, metals, and nutrient monitoring.
Microbiological sample containers must be sterile and contain sodium thiosulfate (Na2S2O3) to neutralize residual chlorine and prevent continuous pathogen inactivation in transit.
Chemical preservation methods (e.g., HNO3 to pH < 2 for metals, H2SO4 to pH < 2 for ammonia/nutrients/COD, NaOH to pH > 12 for cyanide) arrest biological activity and prevent chemical precipitation.
A legally defensible Chain of Custody (COC) document must maintain an unbroken record of physical possession, secure transfer, and tamper-evident container tracking from field collection to final reporting.
Last updated: August 2026
Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques
Accurate laboratory analysis is the cornerstone of regulatory compliance, process optimization, and public health protection in drinking water and wastewater operations across Colorado. An analytical result is only as dependable as the sample from which it was derived; improper collection, inadequate preservation, or excessive transit holding times invalidate laboratory data regardless of analytical precision.
1. Fundamental Sampling Classifications: Grab vs. Composite
Regulatory environmental sampling falls into two distinct operational categories: grab samples and composite samples . Selecting the appropriate sampling type depends strictly upon regulatory mandates, the stability of the target constituent, and whether data will represent an instantaneous snapshot or a flow-weighted average. +---------------------------------------------------------------------------------------------------------+
- | SAMPLING METHODOLOGY SELECTION |
- +---------------------------------------------------+-----------------------------------------------------+
- | GRAB SAMPLING | COMPOSITE SAMPLING |
- | - Instantaneous single-point collection | - Multiple aliquots gathered over specified time |
- | - Mandatory for rapidly changing / volatile tests | - Flow-proportional or time-weighted aliquots |
- | - Parameters: pH, DO, Temp, Cl2, VOCs, Coliform | - Parameters: BOD5, TSS, COD, Metals, Nutrients |
- | - Reflects exact condition at moment of capture | - Reflects 24-hr aggregate mass discharge / loading |
- +---------------------------------------------------+-----------------------------------------------------+
- Grab Samples
A grab sample represents an individual, discrete volume of water or wastewater collected at a specific location, depth, and point in time over a period not exceeding 15 minutes . Grab sampling is legally required for constituents that undergo rapid physical, chemical, or biological transformation immediately upon collection:
Physical and Chemical Field Measurements: pH, water temperature, dissolved oxygen (DO), total residual chlorine, and sulfite (must be analyzed immediately in the field within ≤ 15 minutes \le 15\text{ minutes} ≤ 15 minutes ).
Microbiological Indicators: Total coliform, fecal coliform, and Escherichia coli (composite sampling causes unrepresentative microbial die-off or bacterial multiplication during the collection period).
Volatile and Immiscible Compounds: Volatile organic compounds (VOCs), purgeable aromatics, and oil & grease (agitation or composite pumping introduces head-space degassing, volatilization, or container wall adhesion).
Labile Anions and Inorganics: Cyanide ( CN − \text{CN}^- CN − ) and sulfide ( S 2 − \text{S}^{2-} S 2 − ).
Composite Samples
A composite sample consists of a series of individual sample aliquots collected at regular intervals throughout a defined monitoring period (typically 24 hours ) and combined into a single homogeneous volume. Composite sampling averages diurnal process fluctuations, representing the aggregate discharge mass loading under Clean Water Act (CWA) National Pollutant Discharge Elimination System ( NPDES ) and Colorado Discharge Permit System ( CDPS ) permits.
Time-Weighted Composite Sampling: Discrete sample aliquots of identical volume are collected at fixed time increments (e.g., 100 mL 100\text{ mL} 100 mL every 60 minutes for 24 hours), regardless of wastewater stream flow rate. This method is suitable only where flow rates remain relatively constant.
Flow-Proportional Composite Sampling: The volume of each aliquot or the frequency of aliquot collection varies in direct proportion to the instantaneous effluent flow rate. Automatic composite samplers receive a pacing signal (pulse or 4 – 20 mA 4\text{--}20\text{ mA} 4 – 20 mA ) from a flow meter (such as a Parshall flume ultrasonic transducer or magnetic flowmeter). Aliquot Volume V i = V base × ( Q i Q average ) \text{Aliquot Volume } V_i = V_{\text{base}} \times \left(\frac{Q_i}{Q_{\text{average}}}\right) Aliquot Volume V i = V base × ( Q average Q i )
Where:
- V i V_i V i = Volume of individual aliquot to sample ( m L mL m L )
- V base V_{\text{base}} V base = Programmed base aliquot volume ( m L mL m L )
- Q i Q_i Q i = Instantaneous flow rate during the sampling interval ( M G D MGD MG D or g p m gpm g p m )
Q average Q_{\text{average}} Q average = Anticipated average daily flow rate ( M G D MGD MG D or g p m gpm g p m )
Worked Example 9.1.1: Calculating Flow-Proportional Composite Aliquots
An automated sampler is programmed to collect a 24-hour composite with a base volume ( V base V_{\text{base}} V base ) of 120 mL 120\text{ mL} 120 mL when plant flow is at the design average of 4.0 MGD 4.0\text{ MGD} 4.0 MGD . During peak morning flow at 08:00, the instantaneous flow rate reaches 6.5 MGD 6.5\text{ MGD} 6.5 MGD . During minimum night flow at 03:00, the flow drops to 1.8 MGD 1.8\text{ MGD} 1.8 MGD . Calculate the aliquot volume the sampler must pull at 08:00 and at 03:00.
Step 1: Calculate the peak morning aliquot volume ( V 08 : 00 V_{08:00} V 08 : 00 ): V 08 : 00 = 120 mL × ( 6.5 MGD 4.0 MGD ) = 120 mL × 1.625 = 195.0 mL V_{08:00} = 120\text{ mL} \times \left(\frac{6.5\text{ MGD}}{4.0\text{ MGD}}\right) = 120\text{ mL} \times 1.625 = 195.0\text{ mL} V 08 : 00 = 120 mL × ( 4.0 MGD 6.5 MGD ) = 120 mL × 1.625 = 195.0 mL
Step 2: Calculate the low nighttime aliquot volume ( V 03 : 00 V_{03:00} V 03 : 00 ): V 03 : 00 = 120 mL × ( 1.8 MGD 4.0 MGD ) = 120 mL × 0.450 = 54.0 mL V_{03:00} = 120\text{ mL} \times \left(\frac{1.8\text{ MGD}}{4.0\text{ MGD}}\right) = 120\text{ mL} \times 0.450 = 54.0\text{ mL} V 03 : 00 = 120 mL × ( 4.0 MGD 1.8 MGD ) = 120 mL × 0.450 = 54.0 mL
2. Sample Container Specifications & Preparation Protocols
The choice of sample container material directly impacts sample integrity. Inappropriate containers can leach contaminants into the sample or adsorb target analytes onto container walls.
Loading diagram... Regulatory Environmental Sampling, Preservation & Chain of Custody Workflow
Container Material Guidelines
High-Density Polyethylene (HDPE) or Polypropylene: Standard containers for inorganic non-metallic minerals, physical parameters, and general wet chemistry analytes (Alkalinity, Hardness, Turbidity, TSS, TDS, Sulfate, Fluoride, Chloride, BOD5). Polyethylene is non-reactive and shatter-resistant.
Fluoropolymer (PTFE / Teflon) or Borosilicate Glass: Mandatory for organic compounds, pesticides, herbicides, PCBs, and oil & grease. Organic constituents can leach plasticizers from polyethylene or diffuse through container pores.
Amber Glass Bottles with Teflon-Lined Septa: Required for light-sensitive analytes and Volatile Organic Compounds (VOCs). Amber glass shields photosensitive compounds from ultraviolet photodegradation. VOC vials ( 40 mL 40\text{ mL} 40 mL ) must be filled to a convex meniscus and sealed without trapping any air bubbles (zero headspace) to prevent volatile degassing into vapor spaces.
Sterile Polyethylene Bags (Whirl-Pak) or Autoclavable Polypropylene Bottles: Required for all bacteriological sampling (Total Coliform, Fecal Coliform, E. coli ). Must contain sodium thiosulfate ( Na 2 S 2 O 3 \text{Na}_2\text{S}_2\text{O}_3 Na 2 S 2 O 3 , typically 10 mg 10\text{ mg} 10 mg per 100 mL 100\text{ mL} 100 mL vessel) to immediately neutralize free and combined chlorine residuals up to 15 mg/L 15\text{ mg/L} 15 mg/L , preventing ongoing bacterial inactivation during transit. Bacteriological Dechlorination Reaction:
- Na2S2O3 + 4 HOCl + H2O ---> 2 NaHSO4 + 4 HCl (Neutralizes Disinfectant Instantly)
- 3. Preservation Techniques & Regulatory Holding Times
Preservation stabilizes target analytes by retarding biological decomposition, hydrolytic chemical reactions, and physical phase changes (volatilization, sorption, or precipitation). EPA 40 CFR Part 136.3 (Table II) and Colorado regulations enforce strict preservation protocols and maximum allowable holding times .
Core Preservation Mechanisms
Refrigeration / Thermal Preservation: Cooling to ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C (above freezing) with wet ice suppresses microbial respiration and slows chemical reaction kinetics. Mandatory for nearly all wastewater and drinking water samples during transport and storage.
Acidification with Nitric Acid ( HNO 3 \text{HNO}_3 HNO 3 ): Lowering sample pH to < 2 < 2 < 2 keeps polyvalent metal cations ( Fe 2 + , Mn 2 + , Pb 2 + , Cu 2 + , Zn 2 + , Cd 2 + \text{Fe}^{2+}, \text{Mn}^{2+}, \text{Pb}^{2+}, \text{Cu}^{2+}, \text{Zn}^{2+}, \text{Cd}^{2+} Fe 2 + , Mn 2 + , Pb 2 + , Cu 2 + , Zn 2 + , Cd 2 + ) in dissolved ionic solution, preventing hydroxide precipitation and adsorption onto vessel walls.
Acidification with Sulfuric Acid ( H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 ): Lowering pH to < 2 < 2 < 2 and cooling to ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C inhibits biological assimilation and conversion of nitrogenous and organic fractions (Ammonia NH 3 -N \text{NH}_3\text{-N} NH 3 -N , Total Kjeldahl Nitrogen TKN, Total Phosphorus, Chemical Oxygen Demand COD).
Alkalinization with Sodium Hydroxide ( NaOH \text{NaOH} NaOH ): Elevating pH to > 12 > 12 > 12 converts volatile, toxic hydrogen cyanide gas ( HCN \text{HCN} HCN ) into stable, non-volatile cyanide ions ( CN − \text{CN}^- CN − ).
Preservation with Zinc Acetate and NaOH \text{NaOH} NaOH : Precipitates dissolved sulfide as stable zinc sulfide ( ZnS \text{ZnS} ZnS ) at pH > 9 \text{pH} > 9 pH > 9 , preventing oxidation to sulfate or outgassing of hydrogen sulfide ( H 2 S \text{H}_2\text{S} H 2 S ).
Master Regulatory Preservation & Holding Time Reference Table
Analytical Parameter Container Type Mandatory Preservative Maximum Holding Time (40 CFR 136) Primary Technical Objective
pH, DO, Temp, Residual Cl₂ Glass or Plastic None (Analyze immediately) ≤ 15 minutes \le 15\text{ minutes} ≤ 15 minutes Prevents rapid gas exchange, temperature shift, and chemical decay
Total / Fecal Coliform, E. coli Sterile Glass or Plastic Na 2 S 2 O 3 \text{Na}_2\text{S}_2\text{O}_3 Na 2 S 2 O 3 + Cool ≤ 10 ∘ C \le 10^\circ\text{C} ≤ 1 0 ∘ C 30 hours 30\text{ hours} 30 hours (Drinking Water) / 8 hours 8\text{ hours} 8 hours (Wastewater NPDES) Dechlorinates sample; retards bacterial die-off or overgrowth
BOD₅ / CBOD₅ HDPE or Glass Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 48 hours 48\text{ hours} 48 hours Suppresses ongoing heterotrophic microbial respiration
Total Suspended Solids (TSS) HDPE or Glass Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 7 days 7\text{ days} 7 days Prevents biological lysis and particle agglomeration/dissolution
Total Dissolved Solids (TDS) HDPE or Glass Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 7 days 7\text{ days} 7 days Prevents mineral precipitation and biological uptake
Turbidity HDPE or Glass Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 48 hours 48\text{ hours} 48 hours Prevents coagulation, flocculation, and biological growth
Ammonia, TKN, Total P, COD HDPE or Glass H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 to pH < 2 \text{pH} < 2 pH < 2 + Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 28 days 28\text{ days} 28 days Stops microbial nitrification, deamination, and organic digestion
Nitrate (Unpreserved) HDPE or Glass Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 48 hours 48\text{ hours} 48 hours Prevents bacterial reduction to nitrite or conversion to ammonia
Nitrate + Nitrite (Combined) HDPE or Glass H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 to pH < 2 \text{pH} < 2 pH < 2 + Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 28 days 28\text{ days} 28 days Preserves combined oxidized nitrogen state
Total Metals (Except Mercury) HDPE or Fluoropolymer HNO 3 \text{HNO}_3 HNO 3 to pH < 2 \text{pH} < 2 pH < 2 6 months (180 days) 6\text{ months (180 days)} 6 months (180 days) Prevents cation precipitation and container adsorption
Mercury (Total Hg) Borosilicate Glass HNO 3 \text{HNO}_3 HNO 3 to pH < 2 \text{pH} < 2 pH < 2 + Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 28 days 28\text{ days} 28 days Prevents mercury reduction, volatilization, and glass leaching
Total Cyanide (CN⁻) HDPE or Glass NaOH \text{NaOH} NaOH to pH > 12 \text{pH} > 12 pH > 12 + Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 14 days 14\text{ days} 14 days Prevents conversion to toxic, volatile HCN \text{HCN} HCN gas
Oil & Grease (HEM) Wide-mouth Glass only HCl \text{HCl} HCl or H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 to pH < 2 \text{pH} < 2 pH < 2 + Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 28 days 28\text{ days} 28 days Prevents bacterial lipid consumption; glass prevents wall adhesion
Volatile Organics (VOCs) 40 mL 40\text{ mL} 40 mL Amber Vials (Zero Headspace) HCl \text{HCl} HCl to pH < 2 \text{pH} < 2 pH < 2 + Cool ≤ 6 ∘ C \le 6^\circ\text{C} ≤ 6 ∘ C 14 days 14\text{ days} 14 days Eliminates biological degradation and gas-phase volatilization
4. Chain of Custody (COC) Protocols & Legal Admissibility
All regulatory compliance monitoring data must be legally defensible. In legal enforcement proceedings, regulatory agencies must prove that the laboratory result represents the exact, untampered water condition at the time of collection.
The Four Legal Criteria of Sample Custody
A sample is defined as being in legal custody if it meets at least one of the following four conditions:
- It is in the sampler's actual physical possession;
- It is in the sampler's direct, unobstructed visual sight after being in physical possession;
It was in the sampler's physical possession and was subsequently locked in a secure area, vehicle, or locker to prevent unauthorized tampering; OR
It is placed in a designated secure transit container (cooler) sealed with tamper-evident custody tape . +---------------------------------------------------------------------------------------------------------+
- | CHAIN OF CUSTODY (COC) MANDATORY FIELDS |
- +---------------------------------------------------------------------------------------------------------+
- | 1. Unique Sample Identification Number (e.g., WWTP-EFF-20260831-01) |
- | 2. Facility Name, PWSID / CDPS Permit Number, and Sampling Station Location Description |
- | 3. Date and Exact Military Time of Collection (e.g., 2026-08-31 @ 08:45 MST) |
- | 4. Sample Matrix (Potable Finished Water, Surface Raw Water, Wastewater Influent, Final Effluent) |
- | 5. Sampling Method: Discrete Grab or 24-Hour Flow-Proportional Composite |
- | 6. Container Count, Volume, and Material (e.g., 2 x 1L HDPE, 1 x 500mL Sterile Whirl-Pak) |
- | 7. Preservatives Added (e.g., HNO3 to pH < 2, H2SO4 to pH < 2, Na2S2O3, or Unpreserved on Ice) |
- | 8. Analytical Test Parameters Requested (e.g., EPA 200.8 Total Metals, EPA 405.1 BOD5, SM 2540D TSS) |
- | 9. Field Data: Field pH, Temperature, Residual Chlorine (mg/L), and Sampler Observations |
- | 10. Relinquishing & Receiving Signatures, Printed Names, Organizations, and Exact Timestamps |
- | 11. Laboratory Sample Receipt Verification: Cooler Temperature upon receipt (<= 6.0 deg C) |
- +---------------------------------------------------------------------------------------------------------+
- 5. Laboratory Quality Assurance & Quality Control (QA/QC)
Laboratory QA/QC procedures evaluate analytical data precision, accuracy, and background contamination.
1. Blanks
Method Blank (Laboratory Reagent Blank / LRB): Pure deionized water processed through all analytical extraction and digestion steps. Verifies that reagents, glassware, and instruments are free from background contamination.
Field Blank / Trip Blank: Ultra-pure water filled at the laboratory, transported sealed to the field, opened at the sampling station during collection (Field Blank) or kept sealed in the cooler (Trip Blank for VOCs), and returned for analysis. Pinpoints contamination from field airborne sources, container transport, or handling.
2. Matrix Spikes and Accuracy
A Matrix Spike (MS) is an aliquot of an environmental sample to which a known concentration of target analyte is added prior to digestion and analysis. It evaluates analytical accuracy and matrix interference. % Recovery = C spiked − C unspiked C added × 100 \text{\% Recovery} = \frac{C_{\text{spiked}} - C_{\text{unspiked}}}{C_{\text{added}}} \times 100 % Recovery = C added C spiked − C unspiked × 100
Where:
C spiked C_{\text{spiked}} C spiked = Measured analyte concentration in the spiked sample ( mg/L \text{mg/L} mg/L )
C unspiked C_{\text{unspiked}} C unspiked = Measured analyte concentration in the native unspiked sample ( mg/L \text{mg/L} mg/L )
C added C_{\text{added}} C added = Theoretical concentration of standard added to the sample ( mg/L \text{mg/L} mg/L )
Acceptable matrix spike recoveries typically fall between 80% and 120% (or 70% to 130% for complex matrices).
3. Duplicates and Precision
Duplicate (or Replicate) Samples are two separate aliquots drawn from the identical sample container and analyzed independently. They quantify analytical precision, expressed as Relative Percent Difference (RPD) : RPD (%) = ∣ X 1 − X 2 ∣ X 1 + X 2 2 × 100 \text{RPD (\%)} = \frac{|X_1 - X_2|}{\frac{X_1 + X_2}{2}} \times 100 RPD (%) = 2 X 1 + X 2 ∣ X 1 − X 2 ∣ × 100
Where X 1 X_1 X 1 and X 2 X_2 X 2 are the duplicate analytical results. Acceptable laboratory duplicate RPDs are typically ≤ 10 % \le 10\% ≤ 10% to ≤ 20 % \le 20\% ≤ 20% depending on the specific method.
4. Shewhart Control Charts
Laboratories track Quality Control (QC) check standards chronologically on Shewhart control charts:
Upper / Lower Warning Limits (UWL / LWL): Established at ± 2 \pm 2 ± 2 standard deviations ( ± 2 σ \pm 2\sigma ± 2 σ ) from the historical mean ( 95.4 % 95.4\% 95.4% confidence interval).
Upper / Lower Control Limits (UCL / LCL): Established at ± 3 \pm 3 ± 3 standard deviations ( ± 3 σ \pm 3\sigma ± 3 σ ) from the historical mean ( 99.7 % 99.7\% 99.7% confidence interval).
Action Rules: Any single data point exceeding ± 3 σ \pm 3\sigma ± 3 σ , or two consecutive points exceeding ± 2 σ \pm 2\sigma ± 2 σ , or seven consecutive points falling on one side of the mean indicates an out-of-control analytical system requiring corrective action and batch re-analysis.