Study guide
10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry
Colorado Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: State Laws, Regulations & CCWP Certification
1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
2 Chapter 2: Source Water & Drinking Water Treatment Processes
2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle
3 Chapter 3: Disinfection & Chemical Addition
3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices
4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance
4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management
5 Chapter 5: Wastewater Treatment Principles & Biological Processes
5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects
6 Chapter 6: Advanced Wastewater Treatment & Solids Management
6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84
7 Chapter 7: Water Distribution Systems
7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems
8 Chapter 8: Wastewater Collection Systems
8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment
9 Chapter 9: Pumps, Motors & Utility Mechanics
9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control
10 Chapter 10: Laboratory Analysis & Water Quality Monitoring
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)
11 Chapter 11: Operator Mathematics & Applied Calculations
11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance
12 Chapter 12: Safety, Emergency Operations & Compliance
12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties
10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry
Key Takeaways Explain This Topic AI
The 5-day Biochemical Oxygen Demand (BOD5) test requires incubation at 20.0°C ± 1.0°C in complete darkness, mandating a minimum DO depletion of 2.0 mg/L and residual DO of 1.0 mg/L.
The Glucose-Glutamic Acid (GGA) standard check is the primary quality control benchmark for BOD5, requiring an analytical recovery of 198 ± 30.5 mg/L.
Chemical Oxygen Demand (COD) provides rapid chemical oxidation of organics within 2 hours using potassium dichromate in concentrated sulfuric acid at 150°C.
Total Suspended Solids (TSS) are captured on glass fiber filters and dried at 103°C–105°C, while Volatile Suspended Solids (VSS) are ignited at 550°C in a muffle furnace.
Sludge Volume Index (SVI) calculates the volume in milliliters occupied by one gram of settled sludge after 30 minutes; values between 80 and 150 mL/g indicate optimal settling characteristics.
Last updated: August 2026
Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry
Wastewater treatment facilities operate under strict effluent discharge limitations governed by the Clean Water Act (CWA) , EPA 40 CFR Part 133 (Secondary Treatment Standards) , and CDPHE Regulation 62 (Colorado Discharge Permit System). Regulatory compliance and biological process control depend directly upon precise laboratory quantification of organic loading, solids partitioning, and sludge settleability.
1. 5-Day Biochemical Oxygen Demand (BOD5 & CBOD5)
Biochemical Oxygen Demand (BOD5) is the empirical bioassay measuring the mass of dissolved oxygen consumed by heterotrophic microorganisms while biochemically oxidizing organic matter in wastewater over a 5-day period. Organic Matter + Microorganisms + O 2 ⟶ CO 2 + H 2 O + New Biomass \text{Organic Matter} + \text{Microorganisms} + \text{O}_2 \longrightarrow \text{CO}_2 + \text{H}_2\text{O} + \text{New Biomass} Organic Matter + Microorganisms + O 2 ⟶ CO 2 + H 2 O + New Biomass
Standard Analytical Conditions (Standard Methods 5210B)
Incubation Bottle: 300 mL 300\text{ mL} 300 mL borosilicate glass BOD bottles with tapered ground-glass stoppers and flared liquid-seal necks. Bottles must be filled with water seals and capped with plastic covers to prevent evaporation.
Incubation Temperature: Thermostatically controlled incubator maintained at 20.0 ∘ C ± 1.0 ∘ C 20.0^\circ\text{C} \pm 1.0^\circ\text{C} 20. 0 ∘ C ± 1. 0 ∘ C .
Incubation Duration: Exactly 5 days ± 6 hours 5\text{ days} \pm 6\text{ hours} 5 days ± 6 hours (120 hours) .
Total Darkness: Incubator interior must be completely dark to prevent photosynthetic oxygen generation by microscopic algae.
Dilution Water Preparation: High-purity deionized water aerated to saturation with dissolved oxygen (approx. 8.5 – 9.0 mg/L 8.5\text{--}9.0\text{ mg/L} 8.5 – 9.0 mg/L at sea level; 7.0 – 7.5 mg/L 7.0\text{--}7.5\text{ mg/L} 7.0 – 7.5 mg/L at Colorado mountain elevations). Dilution water is buffered using analytical nutrient pillows containing phosphate buffer ( pH 7.2 \text{pH } 7.2 pH 7.2 ), magnesium sulfate ( MgSO 4 \text{MgSO}_4 MgSO 4 ), calcium chloride ( CaCl 2 \text{CaCl}_2 CaCl 2 ), and ferric chloride ( FeCl 3 \text{FeCl}_3 FeCl 3 ). Dilution Water Blank QC Criterion: Dissolved Oxygen Depletion <= 0.20 mg/L over 5 Days
Seeding & Carbonaceous BOD (CBOD5)
Microbial Seed: Disinfected (chlorinated/UV-treated) effluents, industrial wastes, or high-temperature samples lack viable heterotrophic bacteria. They must be inoculated with an acclimated microbial seed (fresh unchlorinated secondary effluent or commercial bacterial seed capsules such as PolySeed).
Carbonaceous BOD (CBOD5): Autotrophic nitrifying bacteria ( Nitrosomonas and Nitrobacter ) oxidize ammonia nitrogen to nitrite and nitrate, exerting Nitrogenous Biochemical Oxygen Demand (NOD) : NH 4 + + 2 O 2 ⟶ NO 3 − + 2 H + + H 2 O \text{NH}_4^+ + 2\text{O}_2 \longrightarrow \text{NO}_3^- + 2\text{H}^+ + \text{H}_2\text{O} NH 4 + + 2 O 2 ⟶ NO 3 − + 2 H + + H 2 O To measure only carbonaceous oxygen demand, add TCMP (2-chloro-6-(trichloromethyl)pyridine), a chemical nitrification inhibitor that selectively halts nitrifying bacteria without inhibiting carbon-oxidizing heterotrophs.
Regulatory Acceptance & Quality Control Criteria
For an analytical BOD dilution bottle to be valid for compliance reporting, it must satisfy two mandatory criteria:
Minimum DO Depletion: The sample must consume at least 2.0 mg/L 2.0\text{ mg/L} 2.0 mg/L of dissolved oxygen over the 5-day incubation ( D O initial − D O final ≥ 2.0 mg/L DO_{\text{initial}} - DO_{\text{final}} \ge 2.0\text{ mg/L} D O initial − D O final ≥ 2.0 mg/L ).
Minimum Residual DO: The sample bottle must retain at least 1.0 mg/L 1.0\text{ mg/L} 1.0 mg/L of dissolved oxygen at the conclusion of Day 5 ( D O final ≥ 1.0 mg/L DO_{\text{final}} \ge 1.0\text{ mg/L} D O final ≥ 1.0 mg/L ).
Glucose-Glutamic Acid (GGA) Standard Check: A standard solution containing 150 mg/L 150\text{ mg/L} 150 mg/L reagent-grade glucose and 150 mg/L 150\text{ mg/L} 150 mg/L glutamic acid ( 6.0 mL 6.0\text{ mL} 6.0 mL of GGA standard in a 300 mL 300\text{ mL} 300 mL bottle) must achieve a 5-day BOD recovery of 198 ± 30.5 mg/L 198 \pm 30.5\text{ mg/L} 198 ± 30.5 mg/L (valid acceptance range: 167.5 to 228.5 mg/L 167.5\text{ to } 228.5\text{ mg/L} 167.5 to 228.5 mg/L ).
Mathematical BOD Formulas & Calculations
1. Unseeded BOD Formula: BOD 5 (mg/L) = D O initial − D O final P \text{BOD}_5\text{ (mg/L)} = \frac{DO_{\text{initial}} - DO_{\text{final}}}{P} BOD 5 (mg/L) = P D O initial − D O final
Where P = Dilution Fraction = Sample Volume (mL) 300 mL P = \text{Dilution Fraction} = \frac{\text{Sample Volume (mL)}}{300\text{ mL}} P = Dilution Fraction = 300 mL Sample Volume (mL) .
2. Seeded BOD Formula: BOD 5 (mg/L) = ( D O initial − D O final ) − ( B 1 − B 2 ) × f P \text{BOD}_5\text{ (mg/L)} = \frac{(DO_{\text{initial}} - DO_{\text{final}}) - (B_1 - B_2) \times f}{P} BOD 5 (mg/L) = P ( D O initial − D O final ) − ( B 1 − B 2 ) × f
Where:
- B 1 B_1 B 1 = Initial DO of seed control bottle ( mg/L \text{mg/L} mg/L )
- B 2 B_2 B 2 = Day 5 DO of seed control bottle ( mg/L \text{mg/L} mg/L )
f f f = Ratio of seed volume in sample bottle to seed volume in seed control bottle: f = mL seed in sample bottle mL seed in seed control bottle f = \frac{\text{mL seed in sample bottle}}{\text{mL seed in seed control bottle}} f = mL seed in seed control bottle mL seed in sample bottle
Worked Example 9.3.1: Seeded BOD5 Calculation
A laboratory technician sets up a seeded BOD5 test on primary effluent. A 300 mL 300\text{ mL} 300 mL bottle receives 15.0 mL 15.0\text{ mL} 15.0 mL of wastewater sample and 2.0 mL 2.0\text{ mL} 2.0 mL of seed. A seed control bottle containing 10.0 mL 10.0\text{ mL} 10.0 mL of seed in 300 mL 300\text{ mL} 300 mL yields an initial DO of 8.60 mg/L 8.60\text{ mg/L} 8.60 mg/L and a Day 5 DO of 5.10 mg/L 5.10\text{ mg/L} 5.10 mg/L . The wastewater sample bottle yields an initial DO of 8.40 mg/L 8.40\text{ mg/L} 8.40 mg/L and a Day 5 DO of 3.20 mg/L 3.20\text{ mg/L} 3.20 mg/L . Calculate the wastewater BOD5.
Step 1: Check QC criteria for the sample bottle:
DO Depletion = 8.40 − 3.20 = 5.20 mg/L 8.40 - 3.20 = 5.20\text{ mg/L} 8.40 − 3.20 = 5.20 mg/L (Satisfies ≥ 2.0 mg/L \ge 2.0\text{ mg/L} ≥ 2.0 mg/L requirement)
Residual DO = 3.20 mg/L 3.20\text{ mg/L} 3.20 mg/L (Satisfies ≥ 1.0 mg/L \ge 1.0\text{ mg/L} ≥ 1.0 mg/L requirement)
Step 2: Calculate seed correction factor ( f f f ) and seed DO depletion ( B 1 − B 2 B_1 - B_2 B 1 − B 2 ): f = 2.0 mL 10.0 mL = 0.20 f = \frac{2.0\text{ mL}}{10.0\text{ mL}} = 0.20 f = 10.0 mL 2.0 mL = 0.20 ( B 1 − B 2 ) = 8.60 − 5.10 = 3.50 mg/L (B_1 - B_2) = 8.60 - 5.10 = 3.50\text{ mg/L} ( B 1 − B 2 ) = 8.60 − 5.10 = 3.50 mg/L Seed Correction = 3.50 mg/L × 0.20 = 0.70 mg/L \text{Seed Correction} = 3.50\text{ mg/L} \times 0.20 = 0.70\text{ mg/L} Seed Correction = 3.50 mg/L × 0.20 = 0.70 mg/L
Step 3: Calculate sample dilution fraction ( P P P ): P = 15.0 mL 300.0 mL = 0.050 P = \frac{15.0\text{ mL}}{300.0\text{ mL}} = 0.050 P = 300.0 mL 15.0 mL = 0.050
Step 4: Calculate seeded BOD5: BOD 5 = ( 8.40 − 3.20 ) − 0.70 0.050 = 5.20 − 0.70 0.050 = 4.50 0.050 = 90.0 mg/L \text{BOD}_5 = \frac{(8.40 - 3.20) - 0.70}{0.050} = \frac{5.20 - 0.70}{0.050} = \frac{4.50}{0.050} = 90.0\text{ mg/L} BOD 5 = 0.050 ( 8.40 − 3.20 ) − 0.70 = 0.050 5.20 − 0.70 = 0.050 4.50 = 90.0 mg/L
Loading diagram... Wastewater Solids Gravimetric Separation & Thermal Partitioning
2. Chemical Oxygen Demand (COD)
Chemical Oxygen Demand (COD) is a rapid chemical test that measures the total oxygen equivalent of all organic matter susceptible to oxidation by a strong chemical oxidant. While BOD5 requires 5 days of incubation, COD results are obtained in 2.5 to 3 hours , making COD an invaluable tool for real-time plant process control.
Closed Reflux Colorimetric Method (Standard Methods 5220D)
Chemical Reagents: Sample is pipetted into a sealed borosilicate digestion vial containing potassium dichromate ( K 2 Cr 2 O 7 \text{K}_2\text{Cr}_2\text{O}_7 K 2 Cr 2 O 7 ) as the primary oxidant in concentrated sulfuric acid ( H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 ).
Catalyst: Silver sulfate ( Ag 2 SO 4 \text{Ag}_2\text{SO}_4 Ag 2 SO 4 ) is added to catalyze the oxidation of straight-chain aliphatic hydrocarbons and alcohols.
Chloride Interference Suppressor: Mercuric sulfate ( HgSO 4 \text{HgSO}_4 HgSO 4 ) is added to complex chloride ions ( Cl − \text{Cl}^- Cl − ) as soluble mercuric chloride complexes, preventing chloride from reacting with dichromate to cause false-positive COD elevations.
Digestion Conditions: Vials are heated in a pre-calibrated heating block at 150 ∘ C ± 2 ∘ C 150^\circ\text{C} \pm 2^\circ\text{C} 15 0 ∘ C ± 2 ∘ C for exactly 2 hours (120 minutes) .
Photometric Measurement: As organics are oxidized, hexavalent chromium ( Cr 6 + \text{Cr}^{6+} Cr 6 + , orange) is reduced to trivalent chromium ( Cr 3 + \text{Cr}^{3+} Cr 3 + , green). Spectrophotometric absorbance is measured at 600 nm 600\text{ nm} 600 nm (for high-range COD 100 – 1500 mg/L 100\text{--}1500\text{ mg/L} 100 – 1500 mg/L ) or 420 nm 420\text{ nm} 420 nm (for low-range COD 0 – 150 mg/L 0\text{--}150\text{ mg/L} 0 – 150 mg/L ).
COD:BOD Ratio Dynamics in Wastewater
Typical Raw Domestic Wastewater: COD : BOD 5 \text{COD}:\text{BOD}_5 COD : BOD 5 ratio is typically 1.5 : 1 to 2.5 : 1 1.5:1\text{ to } 2.5:1 1.5 : 1 to 2.5 : 1 .
Final Treated Effluent: Ratio rises to 3.0 : 1 to 5.0 : 1 3.0:1\text{ to } 5.0:1 3.0 : 1 to 5.0 : 1 because biological treatment removes readily biodegradable organics, leaving refractory (non-biodegradable) organic compounds.
Industrial Waste Streams: A high COD : BOD 5 \text{COD}:\text{BOD}_5 COD : BOD 5 ratio ( > 3.0 : 1 > 3.0:1 > 3.0 : 1 ) in raw influent indicates toxic, refractory, or synthetic organic compounds resistant to biological oxidation.
3. Gravimetric Solids Analysis: TSS, TDS, and VSS
Wastewater solids are categorized by physical separation (filtration) and thermal behavior (drying and combustion). +---------------------------------------------------------------------------------------------------------+
- | TOTAL SOLIDS (TS) THERMAL PARTITIONING |
- +---------------------------------------------------+-----------------------------------------------------+
- | TOTAL SUSPENDED SOLIDS (TSS) | TOTAL DISSOLVED SOLIDS (TDS) |
- | - Retained on 1.5 um glass fiber filter | - Passes through 1.5 um glass fiber filter |
- | - Dried at 103°C to 105°C | - Evaporated and dried at 180°C |
- | +-----------------------+-----------------------+ | +-------------------------+-----------------------+ |
- | | Volatile Suspended | Fixed Suspended | | | Volatile Dissolved | Fixed Dissolved | |
- | | Solids (VSS) | Solids (FSS) | | | Solids (VDS) | Solids (FDS) | |
- | | - Burned at 550°C | - Mineral ash residue | | | - Burned at 550°C | - Mineral residue | |
- | | - Organic biomass | - Sand, silt, grit | | | - Soluble organics | - Dissolved salts | |
- | +-----------------------+-----------------------+ | +-------------------------+-----------------------+ |
- +---------------------------------------------------+-----------------------------------------------------+
- 1. Total Suspended Solids (TSS) Procedure (Standard Methods 2540D)
Place a standard Whatman 934-AH or GF/C glass fiber filter disc ( 1.5 μ m 1.5\text{ }\mu\text{m} 1.5 μ m pore size) in a vacuum filtration apparatus. Wash with deionized water, dry in an oven at 103 – 105 ∘ C 103\text{--}105^\circ\text{C} 103 – 10 5 ∘ C , cool in a desiccator , and record tare weight ( W tare W_{\text{tare}} W tare ) on an analytical balance ( 0.1 mg 0.1\text{ mg} 0.1 mg precision).
Filter a well-mixed sample volume ( V V V , typically 25 – 100 mL 25\text{--}100\text{ mL} 25 – 100 mL for mixed liquor or 250 – 1000 mL 250\text{--}1000\text{ mL} 250 – 1000 mL for final effluent).
Dry filter and retained residue in a laboratory drying oven at 103 ∘ C– 105 ∘ C 103^\circ\text{C}\text{--}105^\circ\text{C} 10 3 ∘ C – 10 5 ∘ C for a minimum of 1 hour .
Cool to room temperature in a desiccator and weigh to constant weight ( < 0.5 mg < 0.5\text{ mg} < 0.5 mg weight change): TSS (mg/L) = ( W dry − W tare ) in grams × 1,000,000 Sample Volume (mL) = ( W dry − W tare ) in mg × 1,000 Sample Volume (mL) \text{TSS (mg/L)} = \frac{(W_{\text{dry}} - W_{\text{tare}})\text{ in grams} \times 1{,}000{,}000}{\text{Sample Volume (mL)}} = \frac{(W_{\text{dry}} - W_{\text{tare}})\text{ in mg} \times 1{,}000}{\text{Sample Volume (mL)}} TSS (mg/L) = Sample Volume (mL) ( W dry − W tare ) in grams × 1 , 000 , 000 = Sample Volume (mL) ( W dry − W tare ) in mg × 1 , 000
2. Total Dissolved Solids (TDS) Procedure (Standard Methods 2540C)
The filtrate passing through the TSS glass fiber filter is transferred to a pre-weighed evaporating dish and evaporated to dryness in a drying oven at 180 ∘ C ± 2 ∘ C 180^\circ\text{C} \pm 2^\circ\text{C} 18 0 ∘ C ± 2 ∘ C for 1 hour. Drying at 180 ∘ C 180^\circ\text{C} 18 0 ∘ C removes occluded water of crystallization and decomposes mineral bicarbonates.
3. Volatile Suspended Solids (VSS) Procedure (Standard Methods 2540E)
The dried TSS filter disc is placed in a muffle furnace at 550 ∘ C ± 50 ∘ C 550^\circ\text{C} \pm 50^\circ\text{C} 55 0 ∘ C ± 5 0 ∘ C for 15 to 20 minutes . Organic volatile carbon volatilizes to CO 2 \text{CO}_2 CO 2 , while inorganic mineral ash remains as Fixed Suspended Solids (FSS) . In activated sludge mixed liquor, the MLVSS / MLSS \text{MLVSS}/\text{MLSS} MLVSS / MLSS ratio is typically 0.70 to 0.85 0.70\text{ to } 0.85 0.70 to 0.85 (70–85% active biological biomass). VSS (mg/L) = ( W dry at 105 ∘ C − W ash at 550 ∘ C ) in mg × 1,000 Sample Volume (mL) \text{VSS (mg/L)} = \frac{(W_{\text{dry at } 105^\circ\text{C}} - W_{\text{ash at } 550^\circ\text{C}})\text{ in mg} \times 1{,}000}{\text{Sample Volume (mL)}} VSS (mg/L) = Sample Volume (mL) ( W dry at 10 5 ∘ C − W ash at 55 0 ∘ C ) in mg × 1 , 000
4. Settleometry & Sludge Volume Index (SVI)
Clarifier performance and activated sludge settling kinetics are evaluated using the 30-Minute Settleometer Test .
Settleometer Protocol
A fresh sample of mixed liquor suspended solids (MLSS) is collected from the aeration basin effluent weir.
Pour the sample immediately into a standard 2.0 L 2.0\text{ L} 2.0 L Mallory settleometer or 1.0 L 1.0\text{ L} 1.0 L wide-diameter graduated cylinder. Gently stir with a paddle to halt rotation, then allow the sludge blanket to settle under quiescent conditions for 30 minutes .
Record the Settled Sludge Volume after 30 minutes ( SSV 30 \text{SSV}_{30} SSV 30 in mL/L \text{mL/L} mL/L ). Also observe settling characteristics: settleability speed, interface clarity, and pin-point floc presence.
Sludge Volume Index (SVI) Formula
Sludge Volume Index (SVI) is defined as the volume in milliliters occupied by 1 gram of activated sludge solids after 30 minutes of settling: SVI (mL/g) = SSV 30 (mL/L) × 1,000 mg/g MLSS (mg/L) = SSV 30 (mL/L) MLSS (mg/L) / 1,000 \text{SVI (mL/g)} = \frac{\text{SSV}_{30}\text{ (mL/L)} \times 1{,}000\text{ mg/g}}{\text{MLSS (mg/L)}} = \frac{\text{SSV}_{30}\text{ (mL/L)}}{\text{MLSS (mg/L)} / 1{,}000} SVI (mL/g) = MLSS (mg/L) SSV 30 (mL/L) × 1 , 000 mg/g = MLSS (mg/L) /1 , 000 SSV 30 (mL/L)
Operational Interpretation of SVI Ranges
SVI Range (mL/g) Sludge Blanket Characteristics Clarifier Performance & Process Diagnosis
< 70 mL/g < 70\text{ mL/g} < 70 mL/g Rapid settling; dense, compact sludge; fine straggler pin-floc Old sludge / High MCRT: Over-oxidized biomass; turbid supernatant with sheared pin-floc.
80 – 150 mL/g 80\text{--}150\text{ mL/g} 80 – 150 mL/g Uniform settling blanket; compact sludge mass; crystal clear supernatant Ideal Operating Range: Optimal sludge age; excellent clarifier compaction and clear effluent.
> 150 – 200 mL/g > 150\text{--}200\text{ mL/g} > 150 – 200 mL/g Slow settling; bulky, loose sludge mass; deep clarifier blanket Bulking Sludge: Excessive filamentous bacteria ( Microthrix , Nocardia , Type 021N) or young sludge.
Rising Sludge (Clumps) Sludge settles well initially, then floats in clumps after 1–2 hours Denitrification in Clarifier: Nitrate reduced to N 2 \text{N}_2 N 2 gas bubbles that buoy sludge clumps to surface.