Study guide
11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity
Colorado Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: State Laws, Regulations & CCWP Certification
1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
2 Chapter 2: Source Water & Drinking Water Treatment Processes
2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle
3 Chapter 3: Disinfection & Chemical Addition
3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices
4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance
4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management
5 Chapter 5: Wastewater Treatment Principles & Biological Processes
5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects
6 Chapter 6: Advanced Wastewater Treatment & Solids Management
6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84
7 Chapter 7: Water Distribution Systems
7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems
8 Chapter 8: Wastewater Collection Systems
8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment
9 Chapter 9: Pumps, Motors & Utility Mechanics
9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control
10 Chapter 10: Laboratory Analysis & Water Quality Monitoring
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)
11 Chapter 11: Operator Mathematics & Applied Calculations
11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance
12 Chapter 12: Safety, Emergency Operations & Compliance
12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties
11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity
Key Takeaways Explain This Topic AI
The universal Pounds Formula states: Chemical Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal.
The constant 8.34 represents the mass of one gallon of water and bridges the metric concentration (mg/L, equivalent to parts per million) to Imperial daily mass units (lbs/day).
Commercial dry chemicals with active strengths less than 100% require dividing the calculated pure chemical demand by the decimal purity (Commercial lbs = Pure lbs / Purity Decimal).
Liquid chemical feed calculations must incorporate the solution's Specific Gravity (SG) and percent concentration to determine active chemical mass per gallon: Active lbs/gal = SG × 8.34 × Concentration Decimal.
To convert liquid feed rates from Gallons per Day (GPD) to laboratory/metering pump milliliters per minute (mL/min), multiply GPD by 3,785 mL/gal and divide by 1,440 min/day (shortcut multiplier: GPD × 2.6285 = mL/min).
Last updated: August 2026
Chemical Feed Calculations & The Davidson Pie
Accurate chemical dosing is vital for disinfection, coagulation, pH stabilization, and nutrient removal. Under-dosing fails to achieve pathogen destruction or turbidity reduction, while over-dosing wastes utility funds, risks regulatory violations (such as disinfection byproduct formation), and may create toxic conditions in receiving streams. The standard Pounds Formula (historically taught using the "Davidson Pie" visual mnemonic) serves as the primary tool for calculating chemical addition in water and wastewater systems.
The Fundamental Pounds Formula
The standard formula connects volumetric daily flow, chemical dosage concentration, and the physical density of water: Chemical Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal \mathbf{\text{Chemical Feed (lbs/day)} = \text{Flow (MGD)} \times \text{Dosage (mg/L)} \times 8.34\text{ lbs/gal}} Chemical Feed (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal +-------------------------------------------------------------------------+
- | THE DAVIDSON PIE CHART |
- +-------------------------------------------------------------------------+
- | |
- | [ Pounds / Day ] |
- | ------------------------ |
- | [ Flow ] [ Dose ] [8.34] |
- | (MGD) (mg/L) (lbs/gal) |
- | |
- +-------------------------------------------------------------------------+
- Mathematical Proof of the 8.34 Constant
Operators often ask why 8.34 8.34 8.34 is the universal constant. It is derived from the conversion between metric concentration and English mass units:
1 mg/L = 1 part per million (ppm) = 1 lb chemical 1 , 000 , 000 lbs water 1\text{ mg/L} = 1\text{ part per million (ppm)} = \frac{1\text{ lb chemical}}{1,000,000\text{ lbs water}} 1 mg/L = 1 part per million (ppm) = 1 , 000 , 000 lbs water 1 lb chemical
1 gallon of water = 8.34 lbs 1\text{ gallon of water} = 8.34\text{ lbs} 1 gallon of water = 8.34 lbs
Therefore, 1 Million Gallons (MG) of water = 1 , 000 , 000 gal × 8.34 lbs/gal = 8 , 340 , 000 lbs of water 1\text{ Million Gallons (MG) of water} = 1,000,000\text{ gal} \times 8.34\text{ lbs/gal} = 8,340,000\text{ lbs of water} 1 Million Gallons (MG) of water = 1 , 000 , 000 gal × 8.34 lbs/gal = 8 , 340 , 000 lbs of water
Dosing 1 mg/L 1\text{ mg/L} 1 mg/L into 1 MG 1\text{ MG} 1 MG yields: Mass = 8 , 340 , 000 lbs water × 1 lb chemical 1 , 000 , 000 lbs water = 8.34 lbs chemical \text{Mass} = 8,340,000\text{ lbs water} \times \frac{1\text{ lb chemical}}{1,000,000\text{ lbs water}} = 8.34\text{ lbs chemical} Mass = 8 , 340 , 000 lbs water × 1 , 000 , 000 lbs water 1 lb chemical = 8.34 lbs chemical
Algebraic Variations of the Pounds Formula
Depending on the known and unknown operational variables, the formula can be rearranged:
Desired Parameter Manipulated Formula Operational Application
Chemical Feed Rate (lbs/day) lbs/day = Flow (MGD) × Dose (mg/L) × 8.34 \text{lbs/day} = \text{Flow (MGD)} \times \text{Dose (mg/L)} \times 8.34 lbs/day = Flow (MGD) × Dose (mg/L) × 8.34 Setting gas chlorinators, bulk chemical orders
Delivered Dose (mg/L) Dose (mg/L) = lbs/day Flow (MGD) × 8.34 \text{Dose (mg/L)} = \frac{\text{lbs/day}}{\text{Flow (MGD)} \times 8.34} Dose (mg/L) = Flow (MGD) × 8.34 lbs/day Verifying actual dosage from feed scale logs
Treated Plant Flow (MGD) Flow (MGD) = lbs/day Dose (mg/L) × 8.34 \text{Flow (MGD)} = \frac{\text{lbs/day}}{\text{Dose (mg/L)} \times 8.34} Flow (MGD) = Dose (mg/L) × 8.34 lbs/day Calculating capacity treated by known chemical mass
Static Tank Batch Dose (lbs) lbs = Volume (MG) × Dose (mg/L) × 8.34 \text{lbs} = \text{Volume (MG)} \times \text{Dose (mg/L)} \times 8.34 lbs = Volume (MG) × Dose (mg/L) × 8.34 Shock chlorinating a storage tank or basin
Note for Tank Batch Dosing with Gallons: If tank volume is given in gallons rather than MGD, divide gallons by 1 , 000 , 000 1,000,000 1 , 000 , 000 : lbs chemical = Tank Volume (gal) × Dose (mg/L) × 8.34 1 , 000 , 000 \text{lbs chemical} = \frac{\text{Tank Volume (gal)} \times \text{Dose (mg/L)} \times 8.34}{1,000,000} lbs chemical = 1 , 000 , 000 Tank Volume (gal) × Dose (mg/L) × 8.34
Adjusting for Chemical Purity & Active Constituent Strength
The standard pounds formula calculates the required weight of 100% pure active chemical (such as pure gaseous chlorine, C l 2 Cl_2 C l 2 ). However, many commercial chemicals are shipped as dry compounds or liquid solutions with active strengths significantly below 100%:
Calcium Hypochlorite (HTH): Dry granular/tablet disinfectant typically contains 65% available chlorine by weight ( 0.65 0.65 0.65 purity).
Hydrated Lime ( Ca(OH) 2 \text{Ca(OH)}_2 Ca(OH) 2 ): Commercial lime used for pH/alkalinity adjustment typically possesses 90% purity ( 0.90 0.90 0.90 purity).
Soda Ash ( Na 2 CO 3 \text{Na}_2\text{CO}_3 Na 2 CO 3 ): Industrial grade soda ash typically has 98% purity ( 0.98 0.98 0.98 purity).
To determine the actual pounds of commercial chemical product required to deliver the target dosage, divide the calculated pure pounds by the decimal purity: Commercial Chemical (lbs/day) = Pure Chemical Required (lbs/day) Chemical Purity (as decimal) = Flow (MGD) × Dose (mg/L) × 8.34 Purity (as decimal) \mathbf{\text{Commercial Chemical (lbs/day)} = \frac{\text{Pure Chemical Required (lbs/day)}}{\text{Chemical Purity (as decimal)}} = \frac{\text{Flow (MGD)} \times \text{Dose (mg/L)} \times 8.34}{\text{Purity (as decimal)}}} Commercial Chemical (lbs/day) = Chemical Purity (as decimal) Pure Chemical Required (lbs/day) = Purity (as decimal) Flow (MGD) × Dose (mg/L) × 8.34
Rule of Thumb: Because commercial chemical is never 100% pure, the required weight of commercial chemical will always be greater than the pure active weight calculated by the base pounds formula.
Liquid Chemical Feed Solutions & Specific Gravity
Liquid chemicals—such as sodium hypochlorite ( N a O C l NaOCl N a OCl ), liquid alum, ferric chloride, and aqueous ammonia—require accounting for both solution strength (percent active ingredient by weight) and solution density via Specific Gravity (SG) .
Specific Gravity & Liquid Solution Weight
Specific Gravity is the ratio of the density of a liquid compared to the density of pure water at 4 ∘ C 4^\circ\text{C} 4 ∘ C ( 1.000 SG = 8.34 lbs/gal 1.000\text{ SG} = 8.34\text{ lbs/gal} 1.000 SG = 8.34 lbs/gal ): Liquid Solution Density (lbs/gal) = Specific Gravity (SG) × 8.34 lbs/gal \text{Liquid Solution Density (lbs/gal)} = \text{Specific Gravity (SG)} \times 8.34\text{ lbs/gal} Liquid Solution Density (lbs/gal) = Specific Gravity (SG) × 8.34 lbs/gal
To calculate the active pounds of chemical contained within one gallon of liquid solution: Active Chemical (lbs/gal) = SG × 8.34 lbs/gal × % Active Concentration (as decimal) \mathbf{\text{Active Chemical (lbs/gal)} = \text{SG} \times 8.34\text{ lbs/gal} \times \% \text{ Active Concentration (as decimal)}} Active Chemical (lbs/gal) = SG × 8.34 lbs/gal × % Active Concentration (as decimal) +-----------------------------------------------------------------------------------------+
- | TYPICAL LIQUID CHEMICAL CHARACTERISTICS |
- +-----------------------------------------------------------------------------------------+
- | Chemical Solution | Typical Specific Gravity (SG) | Concentration (% by weight) |
- +-------------------------+-------------------------------+-------------------------------+
- | Sodium Hypochlorite | 1.18 to 1.22 (avg. 1.20) | 10.0% to 15.0% (avg. 12.5%) |
- | Liquid Alum | 1.32 to 1.34 (avg. 1.33) | 48.0% to 50.0% (dry equiv.) |
- | Ferric Chloride | 1.38 to 1.45 (avg. 1.42) | 37.0% to 42.0% (FeCl3) |
- | Sodium Hydroxide (50%) | 1.52 to 1.54 (avg. 1.53) | 50.0% (NaOH) |
- | Sulfuric Acid (93%) | 1.83 to 1.84 (avg. 1.84) | 93.2% (H2SO4) |
- +-----------------------------------------------------------------------------------------+
- Determining Liquid Feed Rates (Gallons per Day & mL/min)
Once the pure chemical demand is established, the daily volumetric feed rate of liquid chemical is calculated: Liquid Chemical Feed (GPD) = Pure Chemical Demand (lbs/day) Active Chemical per Gallon (lbs/gal) \text{Liquid Chemical Feed (GPD)} = \frac{\text{Pure Chemical Demand (lbs/day)}}{\text{Active Chemical per Gallon (lbs/gal)}} Liquid Chemical Feed (GPD) = Active Chemical per Gallon (lbs/gal) Pure Chemical Demand (lbs/day)
Because metering pumps are calibrated in milliliters per minute (mL/min), the daily gallon feed rate must be converted using time and volumetric factors: Feed Rate (mL/min) = Liquid Feed (GPD) × 3 , 785 mL/gal 1 , 440 min/day = Liquid Feed (GPD) × 2.6285 \mathbf{\text{Feed Rate (mL/min)} = \frac{\text{Liquid Feed (GPD)} \times 3,785\text{ mL/gal}}{1,440\text{ min/day}} = \text{Liquid Feed (GPD)} \times 2.6285} Feed Rate (mL/min) = 1 , 440 min/day Liquid Feed (GPD) × 3 , 785 mL/gal = Liquid Feed (GPD) × 2.6285
Dry Chemical Feeder Calibration & Catch Sampling
Dry chemical feeders (volumetric screw feeders, belt gravimetric feeders) require routine physical calibration. An operator places a catch container beneath the feed chute, collects chemical for a measured time duration (e.g., 5 or 10 minutes), and weighs the catch on a digital balance. Feed Rate (lbs/day) = Mass Caught (lbs) Time (minutes) × 1 , 440 min/day \text{Feed Rate (lbs/day)} = \frac{\text{Mass Caught (lbs)}}{\text{Time (minutes)}} \times 1,440\text{ min/day} Feed Rate (lbs/day) = Time (minutes) Mass Caught (lbs) × 1 , 440 min/day
If the mass is measured in grams on a laboratory balance, convert grams to pounds by dividing by 453.6 grams/lb 453.6\text{ grams/lb} 453.6 grams/lb : Feed Rate (lbs/day) = Mass Caught (grams) 453.6 g/lb × Time (minutes) × 1 , 440 min/day \text{Feed Rate (lbs/day)} = \frac{\text{Mass Caught (grams)}}{453.6\text{ g/lb} \times \text{Time (minutes)}} \times 1,440\text{ min/day} Feed Rate (lbs/day) = 453.6 g/lb × Time (minutes) Mass Caught (grams) × 1 , 440 min/day
- Step-by-Step Worked Exam Calculations
- Worked Example 1: Chlorine Gas Feed Rate
Problem: A water treatment plant treating a constant flow of 4.50 MGD 4.50\text{ MGD} 4.50 MGD maintains a primary chlorine disinfectant dosage of 2.80 mg/L 2.80\text{ mg/L} 2.80 mg/L . Determine the required chlorine gas ( 100 % C l 2 100\%\ Cl_2 100% C l 2 ) feed rate setting in pounds per day.
Step 1: Apply the standard pounds formula. Feed Rate (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal \text{Feed Rate (lbs/day)} = \text{Flow (MGD)} \times \text{Dosage (mg/L)} \times 8.34\text{ lbs/gal} Feed Rate (lbs/day) = Flow (MGD) × Dosage (mg/L) × 8.34 lbs/gal Feed Rate (lbs/day) = 4.50 MGD × 2.80 mg/L × 8.34 lbs/gal \text{Feed Rate (lbs/day)} = 4.50\text{ MGD} \times 2.80\text{ mg/L} \times 8.34\text{ lbs/gal} Feed Rate (lbs/day) = 4.50 MGD × 2.80 mg/L × 8.34 lbs/gal Feed Rate (lbs/day) = 12.60 × 8.34 = 105.08 lbs/day (or 105.1 lbs/day) \text{Feed Rate (lbs/day)} = 12.60 \times 8.34 = \mathbf{105.08\text{ lbs/day}}\text{ (or } 105.1\text{ lbs/day)} Feed Rate (lbs/day) = 12.60 × 8.34 = 105.08 lbs/day (or 105.1 lbs/day)
Worked Example 2: Liquid Sodium Hypochlorite Dosing & Pump Calibration
Problem: A wastewater reclamation facility operates at a design effluent flow of 2.00 MGD 2.00\text{ MGD} 2.00 MGD and requires a chlorine disinfection dosage of 6.00 mg/L 6.00\text{ mg/L} 6.00 mg/L . The plant feeds commercial sodium hypochlorite solution containing 12.5 % 12.5\% 12.5% available chlorine by weight with a Specific Gravity of 1.20 1.20 1.20 . Calculate:
The daily pure chlorine demand in lbs/day.
The active chlorine concentration in lbs per gallon of solution.
The required liquid hypochlorite feed rate in gallons per day (GPD).
The chemical metering pump calibration rate in milliliters per minute (mL/min).
Step 1: Calculate pure chlorine demand in lbs/day. Pure C l 2 (lbs/day) = 2.00 MGD × 6.00 mg/L × 8.34 lbs/gal = 100.08 lbs/day \text{Pure } Cl_2\text{ (lbs/day)} = 2.00\text{ MGD} \times 6.00\text{ mg/L} \times 8.34\text{ lbs/gal} = \mathbf{100.08\text{ lbs/day}} Pure C l 2 (lbs/day) = 2.00 MGD × 6.00 mg/L × 8.34 lbs/gal = 100.08 lbs/day
Step 2: Calculate active chlorine pounds per gallon of solution. Solution Weight = 1.20 (SG) × 8.34 lbs/gal = 10.008 lbs/gal \text{Solution Weight} = 1.20\text{ (SG)} \times 8.34\text{ lbs/gal} = 10.008\text{ lbs/gal} Solution Weight = 1.20 (SG) × 8.34 lbs/gal = 10.008 lbs/gal Active C l 2 /gal = 10.008 lbs/gal × 0.125 (purity) = 1.251 lbs C l 2 /gal \text{Active } Cl_2\text{/gal} = 10.008\text{ lbs/gal} \times 0.125\text{ (purity)} = \mathbf{1.251\text{ lbs } Cl_2\text{/gal}} Active C l 2 /gal = 10.008 lbs/gal × 0.125 (purity) = 1.251 lbs C l 2 /gal
Step 3: Calculate liquid feed rate in gallons per day (GPD). Liquid Feed (GPD) = 100.08 lbs C l 2 /day 1.251 lbs C l 2 /gal = 80.00 GPD \text{Liquid Feed (GPD)} = \frac{100.08\text{ lbs } Cl_2\text{/day}}{1.251\text{ lbs } Cl_2\text{/gal}} = \mathbf{80.00\text{ GPD}} Liquid Feed (GPD) = 1.251 lbs C l 2 /gal 100.08 lbs C l 2 /day = 80.00 GPD
Step 4: Convert GPD to mL/min for pump calibration. Feed Rate (mL/min) = 80.00 gal/day × 3 , 785 mL/gal 1 , 440 min/day = 302 , 800 mL/day 1 , 440 min/day = 210.28 mL/min ≈ 210.3 mL/min \text{Feed Rate (mL/min)} = \frac{80.00\text{ gal/day} \times 3,785\text{ mL/gal}}{1,440\text{ min/day}} = \frac{302,800\text{ mL/day}}{1,440\text{ min/day}} = \mathbf{210.28\text{ mL/min}} \approx \mathbf{210.3\text{ mL/min}} Feed Rate (mL/min) = 1 , 440 min/day 80.00 gal/day × 3 , 785 mL/gal = 1 , 440 min/day 302 , 800 mL/day = 210.28 mL/min ≈ 210.3 mL/min
Worked Example 3: Calcium Hypochlorite (65%) Well Disinfection
Problem: A deep drinking water well casing and gravel pack contain a total static volume of 8 , 500 gallons 8,500\text{ gallons} 8 , 500 gallons . Following maintenance, the well must be shock-chlorinated to an initial concentration of 150 mg/L 150\text{ mg/L} 150 mg/L using granular calcium hypochlorite ( 65 % 65\% 65% available chlorine). How many pounds of granular product must be dissolved and introduced into the well?
Step 1: Calculate the pure chlorine mass required. Pure C l 2 (lbs) = 8 , 500 gal × 150 mg/L × 8.34 lbs/gal 1 , 000 , 000 = 10 , 633 , 500 1 , 000 , 000 = 10.6335 lbs pure C l 2 \text{Pure } Cl_2\text{ (lbs)} = \frac{8,500\text{ gal} \times 150\text{ mg/L} \times 8.34\text{ lbs/gal}}{1,000,000} = \frac{10,633,500}{1,000,000} = 10.6335\text{ lbs pure } Cl_2 Pure C l 2 (lbs) = 1 , 000 , 000 8 , 500 gal × 150 mg/L × 8.34 lbs/gal = 1 , 000 , 000 10 , 633 , 500 = 10.6335 lbs pure C l 2
Step 2: Correct for 65% chemical purity. Granular Product (lbs) = 10.6335 lbs pure C l 2 0.65 (purity) = 16.36 lbs of Calcium Hypochlorite \text{Granular Product (lbs)} = \frac{10.6335\text{ lbs pure } Cl_2}{0.65\text{ (purity)}} = \mathbf{16.36\text{ lbs of Calcium Hypochlorite}} Granular Product (lbs) = 0.65 (purity) 10.6335 lbs pure C l 2 = 16.36 lbs of Calcium Hypochlorite