Study guide

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping

Key Takeaways Explain This Topic AI

Multi-level intake ports let the operator draw from the depth with the best quality, avoiding the anoxic hypolimnion in summer and the algal surface layer during blooms.

The screening sequence runs coarse to fine: trash rack, then traveling water screen, then microstrainer, with each stage protecting the next.

Traveling water screens are washed by high-pressure spray, and rising differential head across the screen is the primary indicator that washing or debris removal is needed.

Frazil ice forms as supercooled crystals in turbulent open water below freezing and adheres to submerged trash racks and screens, blocking intakes without visible surface ice.

Raw water low-lift pumps must be protected against running dry and against suction-side blockage, so intake wet-well level, screen differential, and pump amperage are monitored together.

Last updated: August 2026

The first equipment in the train

Everything downstream depends on getting raw water into the plant reliably and free of debris. The WPI Equipment Operation and Maintenance outline lists "raw water intake, screening, and pumping" as the first item an operator inspects, maintains, and operates, and a plant that loses its intake has lost everything.

Intake configurations

Type Description Where used

Submerged crib or screened pipe Screened opening on the bed of a lake or river, feeding a shore well by gravity Lakes and reservoirs, shallow rivers

Intake tower Vertical structure in the reservoir with multiple ports at different elevations Deep stratified reservoirs

Shore intake / wet well Structure on the bank with screening and low-lift pumps Rivers

Infiltration gallery Perforated pipe in the streambed aquifer, filtered by the bed material Alluvial rivers; may still be GWUDI

Floating or barge intake Suspended at a chosen depth, follows fluctuating levels Reservoirs with wide drawdown

The multi-level intake tower is the operator's most valuable water quality tool. A stratified Colorado reservoir has warm, algae-bearing water at the surface and cold, anoxic water carrying dissolved iron, manganese, ammonia, and sulfide at the bottom. Mid-depth withdrawal usually gives the best water. During a summer cyanobacteria bloom you drop below the epilimnion; when the hypolimnion goes anoxic you rise above it; after turnover the whole column is mixed and port selection stops mattering until stratification re-establishes. Ports are exercised on a schedule so gates do not seize in position, and each port should have a sampling capability so the operator can compare before switching.

Intake velocity is a design constraint with an operational consequence. Approach velocities are kept low — commonly 0.5 ft/s or less at the screen face — to reduce debris and fish entrainment and to limit headloss. High velocity pulls leaves, ice, and organisms onto the screen faster than they can be removed.

Screening equipment, coarse to fine

Trash rack (bar rack). Vertical or inclined steel bars with clear openings of roughly 1 to 3 inches, stopping logs, branches, and large debris. Cleaned by mechanical rake or by hand. A plugged trash rack shows up as a rising differential between river and wet well level.

Traveling water screen. A continuous belt of wire-mesh panels, typically 3/8 inch mesh, that rotates through the flow and is washed at the top by a high-pressure spray wash discharging debris into a trough. Screens may be run continuously in high-debris conditions or intermittently on a timer or differential level setpoint. Rising differential across the screen is the primary operating indicator.

Microstrainer. A rotating drum covered in fine fabric, commonly 20 to 60 microns, that removes algae and fine organic matter. Also backwashed by spray. Microstrainers reduce algal loading on filters, but they blind quickly during heavy blooms.

Fish protection. Where required, fine-mesh screens with low approach velocity, behavioral barriers, or return systems.

Maintenance items to know: spray nozzles plug and must be cleaned or replaced; chain, sprocket, and bearing wear on traveling screens produces mistracking; screen panels corrode and develop holes that pass debris; and the debris trough must actually drain or it backs up into the screen.

Cold-weather intake problems

Two ice phenomena appear on Colorado exams because they genuinely shut plants down.

Anchor ice forms on the streambed and on submerged structures in shallow, turbulent water.

Frazil ice is the more dangerous. In turbulent, open water that has become slightly supercooled, ice forms as fine crystals suspended in the water column rather than as a surface sheet. Those crystals adhere to cold metal — trash racks, screens, and intake gratings — and build up rapidly. The signature is an intake that blocks solid on a clear cold night with no visible surface ice . Countermeasures include heating or coating the rack, backflushing warm water, air bubbling, and switching to an alternate intake.

Raw water (low-lift) pumping

Low-lift or raw water pumps move water from the intake structure to the head of the plant. They are usually vertical turbine pumps set in a wet well, or horizontal split-case pumps with a flooded suction.

Operating essentials:

Never run dry. Vertical turbine pumps rely on pumped water to lubricate line-shaft bearings unless externally lubricated. Low wet-well level must trip the pump, and the level switch is safety equipment, not a convenience.

Suction blockage is the hidden failure. If the screen plugs, wet well level drops, submergence is lost, the pump begins to cavitate or draw a vortex, and motor amperage falls rather than rises. Falling amperage on a raw water pump with rising screen differential is a debris problem, not a pump problem.

Air relief and priming. Where suction lift exists, a priming system with vacuum pumps or foot valves is required, and it must be tested.

Flow matching. The plant is a series of unit processes sized for a design rate. Raw water pumping is throttled, staged, or driven by variable frequency drives to hold a steady plant rate rather than swinging with demand — the clearwell and distribution storage absorb demand variation.

Grit protection. Sand pumped from a river destroys wear rings, mechanical seals, and check valve seats. Presedimentation exists partly to protect this equipment.

Instrumentation to trend: wet well level, screen differential, pump discharge pressure, flow, motor amperage, bearing temperature, and vibration.

Loading diagram... Raw Water Intake and Screening Sequence