Study guide
5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age)
Colorado Water/Wastewater Operator Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: State Laws, Regulations & CCWP Certification
1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting
2 Chapter 2: Source Water & Drinking Water Treatment Processes
2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle
3 Chapter 3: Disinfection & Chemical Addition
3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices
4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance
4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management
5 Chapter 5: Wastewater Treatment Principles & Biological Processes
5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects
6 Chapter 6: Advanced Wastewater Treatment & Solids Management
6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84
7 Chapter 7: Water Distribution Systems
7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems
8 Chapter 8: Wastewater Collection Systems
8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment
9 Chapter 9: Pumps, Motors & Utility Mechanics
9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control
10 Chapter 10: Laboratory Analysis & Water Quality Monitoring
10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)
11 Chapter 11: Operator Mathematics & Applied Calculations
11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance
12 Chapter 12: Safety, Emergency Operations & Compliance
12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties
5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age)
Key Takeaways Explain This Topic AI
Return Activated Sludge (RAS) recycles settled biological biomass from secondary clarifiers back to the aeration basin at 25% to 100% of influent flow, maintaining the required MLSS inventory and controlling clarifier blanket depth (target: 1 to 3 feet).
Waste Activated Sludge (WAS) is the primary operational process control lever, intentionally removing excess daily biomass growth to govern Mean Cell Residence Time (MCRT / Sludge Age) and Food-to-Microorganism (F/M) ratio.
MCRT defines the average residence time (in days) that microorganisms spend within the active biological system; conventional activated sludge targets an MCRT of 5 to 15 days (extended aeration: 15 to 30+ days).
The Food-to-Microorganism (F/M) ratio balances daily applied influent BOD5 mass against total aeration basin MLVSS inventory, with conventional systems operating between 0.2 and 0.5 lb BOD5/lb MLVSS-day.
Sludge Volume Index (SVI), derived from a 30-minute settleometer test, quantifies sludge compactibility and settling characteristics; optimal settling ranges from 80 to 150 mL/g.
Last updated: August 2026
Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age)
Process control of the activated sludge system centers on the precise management of two liquid streams: Return Activated Sludge (RAS) and Waste Activated Sludge (WAS) . While aeration supplies oxygen for metabolism, RAS and WAS dictate the mass, age, settleability, and food balance of the living biological population. An operator controls the entire treatment plant by manipulating these two operational valves.
1. Return Activated Sludge (RAS) Operational Dynamics
In the secondary clarifier, mixed liquor suspended solids settle to the tank floor, leaving clarified, pathogen-reduced effluent above. The concentrated settled biomass ( RAS ) must be returned continuously to the head of the aeration basin. The Activated Sludge Mass Loop:
Primary Effluent (Q, BOD_in) ===> [ Aeration Basin (V_aer, MLSS) ] ===> [ Secondary Clarifier ] ===> Final Effluent (Q - Q_was, TSS_eff)
- ^ |
- |----------- [ RAS (Q_r, RAS_TSS) ] --+
- |
- v
- [ WAS (Q_was, WAS_TSS) ]
- Primary Functions of RAS
Maintaining Aerator Biomass : Replenishing the active microbial population in the aeration basin to instantly inoculate incoming raw wastewater.
Controlling Clarifier Sludge Blanket Depth : Continuously evacuating settled solids from the clarifier floor to maintain a healthy sludge blanket depth between 1.0 and 3.0 feet (0.3 to 0.9 m) .
Setting the RAS Flow Rate ( Q r Q_r Q r )
Typical Flow Range : Q r Q_r Q r is operated at 25% to 75% of influent flow ( Q Q Q ) for conventional carbonaceous systems, and 50% to 100%+ for biological nutrient removal (BNR) and nitrification facilities.
Under-Pumping RAS ( Q r Q_r Q r Too Low) : Sludge blanket deepens (> 4 ft); solids retention time in the clarifier exceeds 2–4 hours; oxygen is depleted, causing denitrification rising sludge or anaerobic septicity; high blankets risk catastrophic solids washout over effluent weirs during peak hydraulic surges.
Over-Pumping RAS ( Q r Q_r Q r Too High) : Draws thin, dilute RAS ( < 4 , 000 mg/L < 4,000\text{ mg/L} < 4 , 000 mg/L ); creates excessive hydraulic turbulence in the clarifier center well; shears settling floc; unnecessarily shortens aeration basin hydraulic retention time.
RAS Flow Rate Calculation (Clarifier Mass Balance)
Assuming negligible solids in the clarified secondary effluent, a steady-state mass balance across the secondary clarifier yields: ( Q + Q r ) × M L S S = Q r × R A S T S S (Q + Q_r) \times MLSS = Q_r \times RAS_{TSS} ( Q + Q r ) × M L SS = Q r × R A S TSS Q r = Q × ( M L S S R A S T S S − M L S S ) Q_r = Q \times \left( \frac{MLSS}{RAS_{TSS} - MLSS} \right) Q r = Q × ( R A S TSS − M L SS M L SS )
Where Q Q Q is influent flow (MGD), M L S S MLSS M L SS is mixed liquor suspended solids (mg/L), and R A S T S S RAS_{TSS} R A S TSS is return sludge concentration (mg/L).
2. Waste Activated Sludge (WAS) and Inventory Control
As heterotrophic and autotrophic bacteria consume BOD and ammonia, they synthesize new cellular protoplasm. Without solids removal, the biomass inventory will increase uncontrollably, eventually overloading the secondary clarifiers.
Purpose of WAS : Purging the exact mass of excess microorganisms synthesized each day to maintain a stable, steady-state biomass inventory, establish the target sludge age, and sustain optimal bio-flocculation.
Wasting Locations : Most facilities waste from the RAS line ( Q was Q_{\text{was}} Q was ), taking advantage of high solids concentration ( 4 , 000 to 10 , 000 mg/L 4,000\text{ to }10,000\text{ mg/L} 4 , 000 to 10 , 000 mg/L ) to minimize volumetric pumping to solids handling units. Some plants waste directly from the aeration basin (Mixed Liquor WAS), which offers a dilute ( 1 , 500 – 3 , 500 mg/L 1,500\text{--}3,500\text{ mg/L} 1 , 500 – 3 , 500 mg/L ) but highly consistent solids concentration.
3. Mean Cell Residence Time (MCRT) / Solids Retention Time (SRT)
Mean Cell Residence Time (MCRT) —also termed Sludge Age or Solids Retention Time (SRT) —is the single most critical operational parameter in biological wastewater engineering. It represents the average duration, in days, that an individual microbial cell remains within the active biological treatment process before being wasted or lost in the effluent. MCRT (days) = Total Mass of Biomass in Active System (lb) Total Mass of Biomass Lost per Day (lb/day) \text{MCRT (days)} = \frac{\text{Total Mass of Biomass in Active System (lb)}}{\text{Total Mass of Biomass Lost per Day (lb/day)}} MCRT (days) = Total Mass of Biomass Lost per Day (lb/day) Total Mass of Biomass in Active System (lb) MCRT = [ V aer × M L S S × 8.34 ] + [ V clar × T S S clar × 8.34 ] ( Q was × W A S T S S × 8.34 ) + ( Q eff × T S S eff × 8.34 ) \text{MCRT} = \frac{[V_{\text{aer}} \times MLSS \times 8.34] + [V_{\text{clar}} \times TSS_{\text{clar}} \times 8.34]}{(Q_{\text{was}} \times WAS_{TSS} \times 8.34) + (Q_{\text{eff}} \times TSS_{\text{eff}} \times 8.34)} MCRT = ( Q was × W A S TSS × 8.34 ) + ( Q eff × TS S eff × 8.34 ) [ V aer × M L SS × 8.34 ] + [ V clar × TS S clar × 8.34 ]
(Note: When clarifier solids inventory is negligible or excluded by facility convention, the numerator simplifies to the Aeration Basin mass alone, often designated as SRT). +-------------------------------------------------------------------------------------+
- | MCRT RANGES ACROSS PROCESS MODES |
- +-------------------------------------------------------------------------------------+
- | Process Mode | Target MCRT Range | Operational Focus |
- +----------------------------------+---------------------+----------------------------+
- | High-Rate Activated Sludge | 1 to 3 days | High BOD removal, low air |
- | Conventional Activated Sludge | 5 to 15 days | Carbonaceous BOD removal |
- | Biological Nitrification | 8 to 20 days | Autotrophic ammonia oxid. |
- | Extended Aeration / Oxidation D. | 15 to 30+ days | Digested sludge, stability |
- +-------------------------------------------------------------------------------------+
Impact of Sludge Age : Operating at a low MCRT (young sludge) produces rapid metabolic rates, high sludge yield, and light, fluffy straggler floc. Operating at a high MCRT (old sludge) produces complete nitrification, low sludge yield, dense floc, and high oxygen demand, but risks pin floc carryover.
4. Food-to-Microorganism ( F / M F/M F / M ) Ratio
The F / M F/M F / M ratio quantifies the organic loading pressure applied to the living microbial community, defined as the pounds of primary effluent BOD 5 \text{BOD}_5 BOD 5 applied per day per pound of mixed liquor volatile suspended solids (MLVSS) under aeration: F / M = Influent BOD 5 Mass Applied (lb/day) Aeration Basin MLVSS Mass (lb) F/M = \frac{\text{Influent } \text{BOD}_5 \text{ Mass Applied (lb/day)}}{\text{Aeration Basin MLVSS Mass (lb)}} F / M = Aeration Basin MLVSS Mass (lb) Influent BOD 5 Mass Applied (lb/day) F / M = Q inf (MGD) × BOD 5 (mg/L) × 8.34 V aer (MG) × M L V S S (mg/L) × 8.34 = Q inf × BOD 5 V aer × M L V S S F/M = \frac{Q_{\text{inf}} \text{ (MGD)} \times \text{BOD}_5 \text{ (mg/L)} \times 8.34}{V_{\text{aer}} \text{ (MG)} \times MLVSS \text{ (mg/L)} \times 8.34} = \frac{Q_{\text{inf}} \times \text{BOD}_5}{V_{\text{aer}} \times MLVSS} F / M = V aer (MG) × M L V SS (mg/L) × 8.34 Q inf (MGD) × BOD 5 (mg/L) × 8.34 = V aer × M L V SS Q inf × BOD 5
Units : Expressed as lb BOD 5 / lb MLVSS ⋅ day \text{lb } \text{BOD}_5 / \text{lb MLVSS}\cdot\text{day} lb BOD 5 / lb MLVSS ⋅ day (or simply day − 1 \text{day}^{-1} day − 1 ).
Operational Ranges :
- Conventional Activated Sludge: 0.2 to 0.5 day⁻¹
- Extended Aeration: 0.05 to 0.15 day⁻¹
- High-Rate / Contact Stabilization: 0.5 to 1.5 day⁻¹
Inverse Relationship with MCRT : As an operator increases wasting (lowering MLVSS inventory and shortening MCRT), the F / M F/M F / M ratio increases. Conversely, decreasing wasting raises MLVSS, lowering the F / M F/M F / M ratio.
5. Sludge Volume Index (SVI) and Settleometry
Sludge settleability is evaluated using the 30-minute settleometer test , performed in a 1-liter graduated cylinder or a 2-liter transparent Mallory settleometer. 30-Minute Settleometer Test:
- Time = 0 min: 1,000 mL uniform MLSS suspension
- Time = 5 min: Rapid initial agglomeration and interface formation
- Time = 30 min: Measure final Settled Sludge Volume (SSV_30 in mL/L)
- The SVI Formula
Sludge Volume Index (SVI) is defined as the volume in milliliters occupied by 1 gram of activated sludge suspended solids after 30 minutes of quiescent settling: S V I (mL/g) = S S V 30 (mL/L) × 1 , 000 mg/g M L S S (mg/L) SVI \text{ (mL/g)} = \frac{SSV_{30} \text{ (mL/L)} \times 1,000 \text{ mg/g}}{MLSS \text{ (mg/L)}} S V I (mL/g) = M L SS (mg/L) SS V 30 (mL/L) × 1 , 000 mg/g +-------------------------------------------------------------------------------------+
- | SVI DIAGNOSTIC INTERPRETATION |
- +-------------------------------------------------------------------------------------+
- | SVI Range (mL/g) | Sludge Condition | Physical Settling Characteristics |
- +------------------+---------------------------+--------------------------------------+
- | < 80 | Old Sludge / Over-aerated | Settles rapidly like sand; leaves a |
- | | | hazy supernatant with fine pin floc |
- | 80 to 150 | Optimal Conventional | Uniform blanket descent; clear |
- | | Sludge | supernatant; excellent compaction |
- | > 150 to 200 | Filamentous Bulking / | Settles very slowly; high blanket; |
- | | Young Sludge | loose fluffy floc; solids washout |
- | > 300 | Severe Bulking Emergency | Little to no settling; clarifier full|
- +-------------------------------------------------------------------------------------+
- 6. Worked Step-by-Step Operator Math Calculations
- Worked Example: Target WAS Calculation for Desired MCRT
A municipal activated sludge plant operates under the following conditions:
- Influent Flow Rate ( Q Q Q ) = 3.0 MGD
- Aeration Basin Volume ( V aer V_{\text{aer}} V aer ) = 1.20 Million Gallons (MG)
- Aeration Basin MLSS = 2,500 mg/L
Return Activated Sludge ( R A S T S S = W A S T S S RAS_{TSS} = WAS_{TSS} R A S TSS = W A S TSS ) = 7,500 mg/L
- Secondary Effluent TSS ( T S S eff TSS_{\text{eff}} TS S eff ) = 10.0 mg/L
- Target MCRT = 8.5 Days
(Clarifier solids inventory is excluded per plant standard) .
Step 1: Calculate the total mass of MLSS under aeration: Mass in Aerator = 1.20 MG × 2 , 500 mg/L × 8.34 = 25 , 020 lbs of MLSS \text{Mass in Aerator} = 1.20\text{ MG} \times 2,500\text{ mg/L} \times 8.34 = 25,020\text{ lbs of MLSS} Mass in Aerator = 1.20 MG × 2 , 500 mg/L × 8.34 = 25 , 020 lbs of MLSS
Step 2: Calculate the total daily allowable mass loss for an 8.5-day MCRT: Total Daily Loss (lb/day) = Total Mass Target MCRT = 25 , 020 lbs 8.5 days = 2 , 943.53 lb/day \text{Total Daily Loss (lb/day)} = \frac{\text{Total Mass}}{\text{Target MCRT}} = \frac{25,020\text{ lbs}}{8.5\text{ days}} = 2,943.53\text{ lb/day} Total Daily Loss (lb/day) = Target MCRT Total Mass = 8.5 days 25 , 020 lbs = 2 , 943.53 lb/day
Step 3: Calculate the daily mass lost in the final secondary effluent: Effluent Loss (lb/day) = 3.0 MGD × 10.0 mg/L × 8.34 = 250.20 lb/day \text{Effluent Loss (lb/day)} = 3.0\text{ MGD} \times 10.0\text{ mg/L} \times 8.34 = 250.20\text{ lb/day} Effluent Loss (lb/day) = 3.0 MGD × 10.0 mg/L × 8.34 = 250.20 lb/day
Step 4: Calculate the required daily WAS mass to be wasted: WAS Mass Target = 2 , 943.53 lb/day − 250.20 lb/day = 2 , 693.33 lb/day \text{WAS Mass Target} = 2,943.53\text{ lb/day} - 250.20\text{ lb/day} = 2,693.33\text{ lb/day} WAS Mass Target = 2 , 943.53 lb/day − 250.20 lb/day = 2 , 693.33 lb/day
Step 5: Calculate the required daily WAS flow rate ( Q was Q_{\text{was}} Q was in MGD): Q was (MGD) = WAS Mass Target (lb/day) W A S T S S (mg/L) × 8.34 = 2 , 693.33 7 , 500 × 8.34 = 2 , 693.33 62 , 550 = 0.04306 MGD Q_{\text{was}} \text{ (MGD)} = \frac{\text{WAS Mass Target (lb/day)}}{WAS_{TSS} \text{ (mg/L)} \times 8.34} = \frac{2,693.33}{7,500 \times 8.34} = \frac{2,693.33}{62,550} = 0.04306\text{ MGD} Q was (MGD) = W A S TSS (mg/L) × 8.34 WAS Mass Target (lb/day) = 7 , 500 × 8.34 2 , 693.33 = 62 , 550 2 , 693.33 = 0.04306 MGD
Step 6: Convert WAS flow rate to Gallons Per Minute (GPM): Q was (GPM) = 0.04306 MGD × 1 , 000 , 000 gal/MG 1 , 440 min/day = 29.9 GPM (set WAS pump to 30 GPM) Q_{\text{was}} \text{ (GPM)} = \frac{0.04306\text{ MGD} \times 1,000,000\text{ gal/MG}}{1,440\text{ min/day}} = 29.9\text{ GPM (set WAS pump to 30 GPM)} Q was (GPM) = 1 , 440 min/day 0.04306 MGD × 1 , 000 , 000 gal/MG = 29.9 GPM (set WAS pump to 30 GPM)