Study guide

8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation

Key Takeaways Explain This Topic AI

High-velocity hydraulic water jetting operates at 1,500 to 2,500 psi and 50 to 80 gpm, propelling the nozzle upstream from the downstream manhole to ensure flow control and prevent catastrophic basement flooding.

Specialized jet nozzles (chisel penetrators, sand flusher nozzles, rotating chain cutters, vibrating nozzles) match specific blockage types including grease plugs, root collars, and compacted gravel.

Mechanical rodding and heavy-duty bucket machines clear severe structural stoppages, dense taproots, and massive debris deposits where hydraulic nozzles cannot penetrate.

Chemical root control utilizes foaming metam sodium and diquat dibromide formulations that fill the pipe crown, killing root tissue on contact without damaging surface vegetation or disrupting downstream biological treatment.

Commercial Fats, Oils, and Grease (FOG) management enforces grease interceptor sizing (20 to 30-minute detention time) and mandates complete pump-outs under the 25% Rule whenever combined grease and solids exceed 25% of liquid depth.

Last updated: August 2026

Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation

Maintaining the structural integrity and hydraulic carrying capacity of a wastewater collection network requires a rigorous, scheduled preventive maintenance program. Unmaintained collection systems inevitably suffer from capacity loss, odor complaints, root damage, and catastrophic pipe blockages that trigger Sanitary Sewer Overflows (SSOs). Modern collection operators utilize high-pressure water jetting, mechanical rodding, chemical root eradication, and commercial grease pretreatment programs to protect municipal assets.

1. Hydraulic Water Jetting (Hydro-Jetting) Fundamentals

High-velocity hydraulic water jetting (hydro-jetting) is the industry-standard method for cleaning small- to medium-diameter gravity sewer mains ( 6 to 18 inches 6\text{ to }18\text{ inches} 6 to 18 inches ): +-------------------------------------------------------------------------+

  • | HIGH-VELOCITY JETTING SPECIFICATIONS |
  • +-------------------------------------------------------------------------+
  • | Operating Pressure: 1,500 to 2,500 psi (103 to 172 bar) |
  • | Water Delivery Flow: 50 to 80 gpm (189 to 303 L/min) |
  • | Hose Specifications: Heavy-duty thermoplastic sewer hose (3/4 to 1 in)|
  • | Hose Travel Speed: 15 to 30 feet per minute (controlled retraction) |
  • | Vacuum Hose Pickup: Positioned at the downstream invert to extract |
  • | dislodged grit, gravel, and grease slurry. |
  • +-------------------------------------------------------------------------+
  • The Mandatory Upstream Jetting Rule

In all routine collection sewer cleaning operations, the jet nozzle MUST be inserted into the downstream manhole and advanced UPSTREAM (against the wastewater flow) toward the next manhole: Upstream Manhole Downstream Manhole

  • +--------------+ +----------------+
  • | | <==== Water Nozzle Drives Upstream | [Jet-Vac Truck]|
  • | Gravity Flow| =================================>| [Water Hose / |
  • | ---------> | Dislodged Grit & Grease Flows Down | Vacuum Tube] |
  • +------+-------+-------------------------------------+-------+--------+
  • | Sewer Main Line |

Crucial Operational Reasons for Upstream Jetting:

Debris Control & Extraction: Dislodged sand, grit, rocks, and grease are washed downstream by the sewer flow directly to the downstream manhole, where the combination Jet-Vac truck's vacuum tube extracts the solids from the line.

Basement Flooding Prevention: If a nozzle were pushed downstream with the flow, water pressure would build up behind the moving blockage, pressurizing the line and forcing sewage backwards up residential service laterals, causing catastrophic basement flooding and plumbing fixture blowouts.

Continuous Visual Monitoring: The operator maintains direct visual observation of the dislodged debris and water clarity emerging into the downstream manhole, ensuring complete line cleaning.

Loading diagram... Preventive Cleaning Operations: Hydro-Jetting Setup, Chemical Foaming & FOG Control

2. Jet Nozzle Mechanics & Selection

Jet nozzles convert hydraulic pump pressure into high-velocity water streams. Rearward-directed orifices (angled between 15 ∘ 15^\circ 1 5 ∘ and 45 ∘ 45^\circ 4 5 ∘ ) generate the forward reactive thrust that propels the heavy hose up the pipe while scouring the walls: +-------------------------------------------------------------------------+

  • | SPECIALIZED JET NOZZLE TYPES |
  • +-------------------------------------------------------------------------+
  • | 1. Penetrator / Chisel Nozzle: |
  • | - Features 1 to 3 forward-facing cutting jets (0°–15°) and 4–6 rear |
  • | thrust jets (30°–45°). |
  • | - Application: Piercing complete blockages, ice dams, and hard grease|
  • | |
  • | 2. Flusher / Granular Scouring Nozzle (Bomb / Sand Nozzle): |
  • | - Heavy, bottom-weighted design with low-angle rear jets (10°–20°). |
  • | - Application: Maximum invert tractive force; pulls heavy gravel, |
  • | sand, and broken rocks down the pipe invert. |
  • | |
  • | 3. Rotating Chain Scraper / Root Cutter Nozzle: |
  • | - High-pressure water spins a central drive turbine spinning hardened|
  • | stainless steel chains expanded against the full pipe circumference|
  • | - Application: Shearing dense root collars and hard calcium scale. |
  • | |
  • | 4. Vibrating / Pulsating Nozzle: |
  • | - Induces rapid pressure pulsations and mechanical vibration. |
  • | - Application: Fracturing stubborn mineral encrustations. |
  • +-------------------------------------------------------------------------+
  • 3. Mechanical Rodding & Bucket Machines

When hydraulic water jetting cannot penetrate a solid obstruction, mechanical clearing methods are deployed:

Mechanical Power Rodders

Utilize continuous or sectional high-tensile spring steel rods rotated by a heavy-duty hydraulic drive motor.

Equipped with specialized cutting heads: corkscrews, bullet cutters, root saws, and augers.

Primary Application: Emergency clearing of rigid blockages (e.g., dense wood/construction stakes, hard mineral deposits, dry grease plugs) to re-establish an initial flow channel when water jetting would cause an immediate upstream surcharge.

Bucket Machines (Power Winches)

Paired engine-driven winches set over adjacent manholes pull an expandable steel clam-shell bucket back and forth along the sewer invert.

Primary Application: Large-diameter trunk sewers and interceptors ( ≥ 24 inches \ge 24\text{ inches} ≥ 24 inches ) choked with massive accumulations of rocks, construction gravel, heavy road silt, or massive grease logs where hydraulic jetting is ineffective.

4. Chemical Root Control Technologies

Tree root intrusion through compromised pipe joints and service lateral connections is a primary cause of structural damage and pipe blockages: +-------------------------------------------------------------------------+

  • | CHEMICAL ROOT CONTROL DYNAMICS |
  • +-------------------------------------------------------------------------+
  • | Delivery Method: High-expansion clinging micro-foam fills 100% of the |
  • | pipe cross-section above the waterline. |
  • | Active Chemicals: 1. Metam Sodium: Fast-acting cellular toxicant that |
  • | kills root tissue on contact. |
  • | 2. Diquat Dibromide: Non-volatile contact herbicide. |
  • | 3. Dichlobenil: Root-growth inhibitor preventing |
  • | re-growth for up to 24 to 36 months. |
  • | Degradation: Killed roots decay and slough away naturally over |
  • | 2 to 6 months without damaging the surface tree. |
  • | Plant Impact: Safe for downstream wastewater treatment plants when |
  • | applied according to EPA label instructions. |
  • +-------------------------------------------------------------------------+
  • 5. Fats, Oils, and Grease (FOG) Management & Pretreatment

Fats, Oils, and Grease (FOG) discharged from commercial food service establishments (restaurants, cafeterias, bakeries) is the leading cause of collection system blockages and dry-weather SSOs across North America.

The Saponification Mechanism

When warm FOG is discharged into municipal sewers, it cools to ambient underground temperature ( 50 ∘ to 55 ∘ F 50^\circ\text{ to }55^\circ\text{F} 5 0 ∘ to 5 5 ∘ F ) and undergoes chemical saponification —reacting with calcium, magnesium, and alkaline compounds in the wastewater and concrete pipe walls to form rock-hard, insoluble calcium fatty-acid salts (metallic soaps or "fatbergs") that adhere tenaciously to pipe walls. Warm Liquid FOG discharged ---> Cools in Sewer Main (50-55°F)

  • |
  • v
  • Reacts with Free Calcium (Ca2+) ---> Saponification Reaction ---> Hard Insoluble Fatberg
  • Commercial Grease Interceptors & Sizing

Hydromechanical Grease Interceptors (HGIs): Compact indoor units placed near individual commercial sinks; rated by flow (gpm) and grease storage capacity (lbs).

Outdoor Gravity Grease Interceptors (GGIs): Large underground two-compartment concrete or fiberglass tanks (typically 750 to 2,500+ gallons ) installed on commercial kitchen waste lines prior to joining the sanitary sewer.

Design Hydraulic Retention Time (HRT): Must provide a minimum detention time of 20 to 30 minutes at peak kitchen drainage flow to allow low-density grease to float to the surface and dense food solids to settle to the bottom. Inflow from Kitchen ----> [ Compartment 1 ] ===> [ Compartment 2 ] ----> Outflow to Sewer

  • +---------------+ +---------------+ (Pretreated)
  • | Floating FOG | | Floating FOG |
  • | ~ ~ ~ ~ ~ ~ ~ | | ~ ~ ~ ~ ~ ~ ~ |
  • | Clear Water |=====>| Clear Water |
  • | _ _ _ _ _ _ _ | | _ _ _ _ _ _ _ |
  • | Settled Food | | Settled Food |
  • +---------------+ +---------------+
  • The Mandatory 25% Rule for Interceptor Maintenance

Commercial pretreatment ordinances strictly enforce the 25% Rule :

A grease interceptor MUST be completely pumped out and cleaned by a licensed waste hauler whenever the combined thickness of the floating grease layer ( T g r e a s e T_{grease} T g re a se ​ ) and the bottom settled solids layer ( T s o l i d s T_{solids} T so l i d s ​ ) equals or exceeds 25% of the total liquid depth ( D l i q u i d D_{liquid} D l i q u i d ​ ) in the tank: Combined FOG/Solids Percentage = ( T g r e a s e + T s o l i d s D l i q u i d ) × 100 ≥ 25 % \text{Combined FOG/Solids Percentage} = \left( \frac{T_{grease} + T_{solids}}{D_{liquid}} \right) \times 100 \ge 25\% Combined FOG/Solids Percentage = ( D l i q u i d ​ T g re a se ​ + T so l i d s ​ ​ ) × 100 ≥ 25%

Warning

Prohibition of Chemical Emulsifiers and Enzymes: Discharging chemical degreasers, surfactants, or enzymatic additives into commercial grease interceptors is strictly illegal under municipal sewer use ordinances . These chemicals merely emulsify grease temporarily, washing it into the public sewer main where it separates and re-solidifies, causing massive main blockages.

  • 6. Worked Maintenance Calculations
  • Worked Example 7.4.1: Hydro-Jetting Water Consumption & Tanker Cycling

A utility maintenance crew is assigned to hydro-jet a 400-foot reach of 10-inch sewer line. The jetting pump operates at 65 gpm . The operator advances the nozzle upstream to the top manhole, and then retracts the nozzle downstream at a steady cleaning speed of 20 feet per minute . If setup and initial upstream travel consumed 400 gallons , calculate the total water consumed during the cleaning cycle and determine if a 1,000-gallon truck water tank is sufficient.

Step 1: Calculate the nozzle retraction cleaning time ( t t t ): t = 400 feet 20 feet/minute = 20.0 minutes t = \frac{400\text{ feet}}{20\text{ feet/minute}} = 20.0\text{ minutes} t = 20 feet/minute 400 feet ​ = 20.0 minutes

Step 2: Calculate water consumed during the controlled cleaning retraction: Water Consumed = 20.0 minutes × 65 gpm = 1 , 300 gallons \text{Water Consumed} = 20.0\text{ minutes} \times 65\text{ gpm} = 1,300\text{ gallons} Water Consumed = 20.0 minutes × 65 gpm = 1 , 300 gallons

Step 3: Calculate total water required for the complete run: Total Water = 400 gal (travel) + 1 , 300 gal (cleaning) = 1 , 700 gallons \text{Total Water} = 400\text{ gal (travel)} + 1,300\text{ gal (cleaning)} = 1,700\text{ gallons} Total Water = 400 gal (travel) + 1 , 300 gal (cleaning) = 1 , 700 gallons

Conclusion: The 1,000-gallon truck water tank is insufficient for a single continuous run. The crew must arrange an on-site hydrant refill connection or schedule a mid-run tank reload.

Worked Example 7.4.2: Grease Interceptor 25% Rule Inspection

A municipal FOG inspector measures an outdoor gravity grease interceptor with a total liquid depth of 48.0 inches . Using a clear Sludge Judge sampling core, the inspector records a floating grease cap thickness of 7.5 inches and a settled bottom solids layer of 6.0 inches . Determine whether the restaurant is in violation of the 25% rule.

Step 1: Calculate combined thickness of floating grease and settled solids: Combined Thickness = 7.5 in + 6.0 in = 13.5 inches \text{Combined Thickness} = 7.5\text{ in} + 6.0\text{ in} = 13.5\text{ inches} Combined Thickness = 7.5 in + 6.0 in = 13.5 inches

Step 2: Calculate percentage of total liquid depth: Percentage = ( 13.5 inches 48.0 inches ) × 100 = 28.125 % \text{Percentage} = \left( \frac{13.5\text{ inches}}{48.0\text{ inches}} \right) \times 100 = 28.125\% Percentage = ( 48.0 inches 13.5 inches ​ ) × 100 = 28.125%

Conclusion: Because 28.1% exceeds the 25.0% regulatory limit , the interceptor is in direct violation. The restaurant must be issued a notice of violation requiring a complete pump-out within 48 hours.