Study guide

8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection

Colorado Water/Wastewater Operator Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: State Laws, Regulations & CCWP Certification

1.1 CDPHE CCWP Program & Regulatory Framework (Regulation 100 / 5 CCR 1003-2) 1.2 Facility Classification & Operator in Responsible Charge (ORC) Requirements 1.3 Certification Levels, Education, Experience & Exam Eligibility (Class D-A, Grade 1-4, Class S/T) 1.4 License Renewal, Training Units (TUs) & Mandatory Regulatory Training 1.5 Colorado Primary Drinking Water Regulations (Regulation 11) & Compliance 1.6 Colorado Discharge Permit System (Regulations 61/62), DMRs & Biosolids Reporting

2 Chapter 2: Source Water & Drinking Water Treatment Processes

2.1 Raw Water Sources, High-Altitude Characteristics & Reservoir Quality 2.2 Coagulation Chemistry, Rapid Mixing & Chemical Dosing (Alum, Ferric, Polymers) 2.3 Flocculation & Sedimentation Basin Design, Operation & Settling Zones 2.4 Granular Media Filtration, Backwash Procedures & Turbidity Standards 2.5 Advanced Treatment: Membranes, Softening, GAC/PAC Adsorption & Aeration 2.6 Groundwater Sources, Well Hydraulics, Static and Pumping Levels & Specific Capacity 2.7 Source Water Characteristics, Contaminant Categories & Watershed Protection Plans 2.8 Pretreatment: Presedimentation, Aeration, Algae Control & Taste-and-Odor Management 2.9 Direct, In-Line, Pressure, Cartridge & Diatomaceous Earth Filtration 2.10 Lime-Soda Softening, Ion Exchange & Water Stabilization 2.11 Water Treatment Plant Residuals: Lagoons, Drying Beds, Land Application & Recycle

3 Chapter 3: Disinfection & Chemical Addition

3.1 Chlorine Chemistry: Hypochlorous Acid, Free/Combined Residual & Breakpoint Chlorination 3.2 Disinfection Kinetics, Baffle Factors, T10 & CT Compliance Calculations 3.3 Disinfection Byproducts (TTHMs, HAA5s) & Stage 1/2 DBP Rules 3.4 Alternative Disinfection: Chloramination, Ultraviolet (UV) Light & Chlorine Dioxide 3.5 Corrosion Control, Lead & Copper Rule Revisions (LCRR) & Fluoridation Practices

4 Chapter 4: Water Treatment Plant Equipment, Instrumentation & Maintenance

4.1 Raw Water Intakes, Screening Equipment & Raw Water Pumping 4.2 Chemical Feed Equipment: Feeders, Day Tanks, Carrier Water & Feed-Rate Calibration 4.3 Chlorination Equipment: Gas Systems, Vacuum Regulators, Hypochlorite Storage & Onsite Generation 4.4 Filter Underdrains, Support Gravel, Surface Wash, Air Scour & Filter-to-Waste 4.5 Plant Process Control, SCADA and PLC Systems, Alarm Management & Records of Operation 4.6 Preventive, Corrective and Predictive Maintenance, Work Orders & Asset Management

5 Chapter 5: Wastewater Treatment Principles & Biological Processes

5.1 Preliminary Treatment: Bar Screens, Shredders, Grit Chambers & Flow Equalization 5.2 Primary Clarification, Solids Separation & Scum Removal Mechanics 5.3 Activated Sludge Fundamentals: Aerobic Microbiology, DO Control & Biomass Growth 5.4 Return & Waste Activated Sludge Management (RAS/WAS Operations & Sludge Age) 5.5 Activated Sludge Troubleshooting: Bulking, Nocardia Foaming, Rising Sludge & Pin Floc 5.6 Wastewater Characteristics, Organic and Hydraulic Loading, Diurnal Flow & Septicity 5.7 Activated Sludge Arrangements: Conventional, Complete Mix, Step Feed, Contact Stabilization, Extended Aeration, Oxidation Ditch, SBR & MBR 5.8 Aeration Systems: Blowers, Diffusers, Surface Aerators, Oxygen Transfer & Altitude Effects

6 Chapter 6: Advanced Wastewater Treatment & Solids Management

6.1 Biological Nutrient Removal: Nitrification, Denitrification & Anoxic Zones 6.2 Biological & Chemical Phosphorus Removal (EBPR & Coagulant Precipitation) 6.3 Sludge Thickening, Aerobic & Anaerobic Digestion (Mesophilic/Thermophilic) 6.4 Dewatering Equipment (Centrifuges, Belt Filter Presses) & Biosolids Standards (Reg 64) 6.5 Pond & Lagoon Operations, Trickling Filters & Rotating Biological Contactors (RBCs) 6.6 Secondary Clarification: Overflow and Solids Loading Rates, RAS Rate Setting & Clarifier Diagnostics 6.7 Tertiary Filtration, Effluent Polishing & Wastewater Disinfection with Chlorine, Dechlorination and UV 6.8 Effluent Disposal, Rapid Infiltration Basins, Colorado Water Reuse Law & Regulation 84

7 Chapter 7: Water Distribution Systems

7.1 Distribution Hydraulics, Pressure Zones, Static Head & Friction Headloss 7.2 Finished Water Storage Tanks, Standpipes, Mixing & Water Age Control 7.3 Distribution Piping, Valves (Gate, Butterfly, PRV), Hydrants & Main Flushing 7.4 Cross-Connection Control, Hazard Assessment & Backflow Preventers (RPZ, DCVA, PVB, Air Gap) 7.5 Water Main Installation, Trenching, Repair, Pressure Testing & Disinfection (AWWA C651) 7.6 Network Layout, Pressure Zones, Demand Patterns, Fire Flow & the Hydraulic Grade Line 7.7 Fire Hydrants, Dry Barrel Operation, Fire Flow Testing & Unidirectional Flushing 7.8 Booster Pump Stations, Hydropneumatic Systems, Controls & Surge Protection 7.9 Customer and Master Metering, Meter Sizing, Accuracy Testing, AMR & AMI 7.10 System Mapping, GIS, As-Builts, Operational Analysis & the AWWA Water Audit 7.11 Service Line Installation, Wet Tapping, Curb Stops & the Lead Service Line Inventory 7.12 Leak Detection, District Metered Areas, Minimum Night Flow & Pressure Management 7.13 Storage Facility Inspection, Sanitary Defects, Water Age Control, Cleaning & AWWA C652 Disinfection 7.14 Utility Locating, Colorado 811 Damage Prevention, the APWA Color Code & New Construction Inspection 7.15 Well and Wellhead Maintenance, Sanitary Condition, Rehabilitation & AWWA C654 Disinfection 7.16 Booster Chlorination, Remote Chemical Feed, Chemical Storage, Security & Supply Management 7.17 Distribution Sampling Technique, Chlorine Residual Monitoring & Nitrification Control in Chloraminated Systems

8 Chapter 8: Wastewater Collection Systems

8.1 Gravity Collection Systems: Flow Velocities, Slopes, Pipe Materials & Manholes 8.2 Wastewater Lift Stations: Wet Wells, Submersible Pumps, Level Controls & Force Mains 8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection 8.4 Collection Maintenance: Hydraulic Jetting, Mechanical Rodding & FOG/Root Mitigation 8.5 Sanitary Sewer Overflows (SSOs): Root Causes, Containment, Reporting & Mitigation 8.6 Lift Station Electrical Devices, Level Detection, Telemetry, Gas Detection & Capacity Adjustment 8.7 Lift Station Configurations, Preventive Maintenance, Wet Well Cleaning, Troubleshooting & Emergency Bypass Pumping 8.8 Collection System Rehabilitation: CIPP, Pipe Bursting, Sliplining, Grouting, Manhole Repair & Tap Defects 8.9 Excavation, Hydro Excavation, Bedding and Haunching, Grade Control & Sewer Acceptance Testing 8.10 Collection System Flow Monitoring, Area-Velocity Metering, Weirs and Flumes & Capacity Assessment

9 Chapter 9: Pumps, Motors & Utility Mechanics

9.1 Centrifugal Pumps: Volutes, Impellers, Packing Seals & Mechanical Seals 9.2 Positive Displacement Pumps (Peristaltic, Diaphragm, Progressive Cavity) & Dosing Systems 9.3 Pump Performance Curves, System Head Curves, Cavitation & NPSH Calculations 9.4 Electric Motors (Single/Three Phase), Controls, Variable Frequency Drives (VFDs) & Power 9.5 Flow Meters (Venturi, Magnetic, Ultrasonic), Online Analyzers, PLCs & SCADA Telemetry 9.6 Air Compressors, Conveyors, Hoists and Cranes, Service Piping & Standby Power Generation 9.7 Valve Types and Duties, Air Release and Air-Vacuum Valves, Water Hammer & Surge Control

10 Chapter 10: Laboratory Analysis & Water Quality Monitoring

10.1 Regulatory Sampling Procedures, Chain of Custody, Holding Times & Preservation Techniques 10.2 Physical & Chemical Drinking Water Testing: Turbidity, pH, Alkalinity, Hardness & Chlorine (DPD) 10.3 Wastewater Laboratory Analysis: BOD5, COD, Total Suspended Solids (TSS) & Settleometry 10.4 Microbiological Testing: Total Coliform, E. coli (Colilert, Membrane Filtration) & QA/QC 10.5 Bench-Scale Jar Testing, Coagulant Optimization & Streaming Current Monitoring 10.6 Laboratory Equipment, Calibration and Verification, QA/QC Program & Certified Laboratory Requirements 10.7 Nutrient Series, Metals Sampling, Whole Effluent Toxicity & Electrode Measurements (DO, pH, ORP, H2S)

11 Chapter 11: Operator Mathematics & Applied Calculations

11.1 Core Conversions, Geometric Area, Pipe Volume & Continuous Flow Rate (MGD, GPM, cfs) 11.2 Chemical Dosage, The Standard "Pounds Formula", Active Chemical & Solution Purity 11.3 Hydraulic Retention Time (HRT), Surface Overflow Rate (SOR) & Weir Overflow Rates 11.4 Process Control Calculations: F/M Ratio, MCRT/Solids Retention Time (SRT) & Sludge Volume Index (SVI) 11.5 Distribution Pressure, Static vs Dynamic Head, Water Horsepower & Wire-to-Water Efficiency 11.6 CT Calculations: Baffling Factors, T10, Temperature and pH Corrections & Multi-Segment Compliance

12 Chapter 12: Safety, Emergency Operations & Compliance

12.1 Permit-Required Confined Space (PRCS) Entry, Atmospheric Testing (O2/LEL/H2S/CO) & Rescue 12.2 Control of Hazardous Energy: Lockout/Tagout (LOTO), Arc Flash & Electrical Safety 12.3 Chemical Safety: Chlorine Gas Handling, Ton Cylinders, Sulfur Dioxide, Ammonia & SDS/GHS 12.4 Trenching & Excavation: Soil Classification, Sloping, Shoring, Shielding & Competent Person Rules 12.5 Emergency Action Plans, Security Vulnerability, Spill Containment & CDPHE Tier 1/2/3 Public Notice 12.6 Work Zone Traffic Control, PPE, Fall Protection, Fire Extinguishers, First Aid & Bloodborne Pathogens 12.7 Standard Operating Procedures, Operating Records, Regulatory Reporting, Customer Complaints & Supervisory Duties

8.3 Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection

Key Takeaways Explain This Topic AI

Inflow is direct stormwater runoff entering the collection system rapidly through surface openings (downspouts, manhole pick holes, sump pumps), creating sharp, steep hydrograph peaks.

Infiltration is groundwater entering subterranean defects (cracked pipes, failing joints, deteriorated manhole walls), characterized by gradual, sustained baseflow increases following precipitation or seasonal snowmelt.

Diurnal wastewater flow follows a predictable double-peak sinusoidal curve; dry-weather minimum nighttime flows between 2:00 AM and 5:00 AM exceeding 25% to 30% of average daily flow indicate severe chronic infiltration.

Smoke testing utilizes non-toxic chemical smoke under positive air pressure to identify direct inflow sources and illegal connections, requiring mandatory multi-agency and public notification 24 to 48 hours in advance.

Internal CCTV robotic inspection utilizes the standardized NASSCO PACP 1-to-5 defect scoring system to categorize structural and operational defects, guiding prioritized trenchless rehabilitation.

Last updated: August 2026

Inflow and Infiltration (I&I) Sources, Flow Monitoring, Smoke Testing & CCTV Inspection

Separate sanitary sewer systems are engineered exclusively to collect and transport domestic, commercial, and industrial wastewater. The entry of extraneous, unpolluted groundwater and surface stormwater—collectively termed Inflow and Infiltration (I&I) —is one of the most pervasive and costly challenges facing wastewater collection utilities. I&I overloads hydraulic capacity, triggers sanitary sewer overflows (SSOs), increases lift station electrical pumping costs, and severely disrupts biological treatment processes at downstream wastewater facilities.

1. Defining Inflow vs. Infiltration & Hydraulic Impacts

Although often discussed together, Inflow and Infiltration enter through distinctly different pathways and exhibit completely different hydraulic signatures: +-------------------------------------------------------------------------+

  • | INFLOW VS. INFILTRATION |
  • +-------------------------------------------------------------------------+
  • | Characteristic | Inflow (Direct Surface Entry) | Infiltration (Groundwater) |
  • +---------------------+-------------------------------+-----------------------------+
  • | Source Type | Direct surface stormwater | Subterranean groundwater |
  • | Entry Pathways | - Vented/pick-hole manholes | - Cracked / crushed pipes |
  • | | - Submerged frame rings | - Deteriorated pipe joints |
  • | | - Roof downspouts (gutters) | - Failing lateral taps |
  • | | - Foundation sump pumps | - Leaking manhole barrels |
  • | | - Yard & driveway drains | - Root-penetrated fissures |
  • | | - Storm sewer cross-links | |
  • | Hydrograph Response | Immediate, rapid spike | Delayed, gradual, sustained |
  • | Peak Timing | Concurrent with rain event | Peaks days/weeks post-storm |
  • | Duration | Hours (subsides with storm) | Days, weeks, or seasonal |
  • +---------------------+-------------------------------+-----------------------------+ Flow Rate (MGD)
  • ^
  • | /\ <--- INFLOW: Sharp, instantaneous stormwater spike
  • | / \
  • | / \_________________
  • | / \ <--- INFILTRATION: Elevated baseflow
  • | _.-'' ''-._ persisting after groundwater rise
  • | / \
  • +---------------------------------------> Time (Days)
  • [--- Rain Event ---]
  • The Operational Hazards of Excessive RDII

Rainfall-Derived Inflow and Infiltration (RDII) creates severe operational failures:

Hydraulic Overloading & SSOs: Wastewater volume exceeds pipeline carrying capacity, surcharging gravity mains and discharging raw sewage onto public streets or into local waterways.

Lift Station Drowning: Inflow floods lift station wet wells beyond pump capacity, tripping electrical alarms and burning out motors.

Treatment Process Disruption: Massive hydraulic surges wash active biomass (activated sludge) out of secondary clarifiers, drastically shorten hydraulic retention time in aeration basins, dilute wastewater temperature and BOD concentration, and dramatically increase chemical disinfection costs.

Loading diagram... I&I Entry Pathways, Hydrograph Response & Field Investigation Hierarchy

2. Diurnal Flow Monitoring & Hydrograph Analysis

Under dry-weather conditions, municipal wastewater collection networks exhibit a predictable, sinusoidal diurnal flow curve reflecting human behavioral patterns: Flow Rate (% of Average Daily Flow)

200% | .-. .-.

  • | / \ <-- Morning Peak / \ <-- Evening Peak
  • 100% | / \ / \
  • | / '._ _.' \
  • 50% | / `'---------'` \
  • | _.._ / \ _.._
  • 0% +-' `'---------------------------------------'`---->
  • 12 AM 3 AM 6 AM 9 AM 12 PM 3 PM 6 PM 9 PM 12 AM
  • [ Nighttime Low ]

Morning Peak (6:00 AM – 9:00 AM): Waking, showering, toilet flushing, breakfast preparation.

Midday Plateau / Dip (11:00 AM – 2:00 PM): Reduced domestic occupancy as population commutes to workplaces.

Evening Peak (6:00 PM – 9:00 PM): Cooking dinner, running dishwashers, laundry, bathing.

Minimum Nighttime Flow (2:00 AM – 5:00 AM): Domestic water use ceases almost entirely.

Infiltration Quantification from Nighttime Flow

During the minimum nighttime window (2:00 AM to 5:00 AM), flow measured by an area-velocity meter represents almost exclusively groundwater infiltration plus minor baseline industrial/commercial 24-hour discharges.

Rule of Thumb: If dry-weather minimum nighttime flow exceeds 25% to 30% of average daily flow (ADF), the basin suffers from significant groundwater infiltration.

3. Smoke Testing Protocols & Public Safety

Smoke testing is an efficient, cost-effective field method used to detect direct inflow sources, illegal connections, and shallow structural pipe breaks: +-------------------------------------------------------------------------+

  • | SMOKE TESTING WORKFLOW |
  • +-------------------------------------------------------------------------+
  • | 1. Public / Agency Notification: Door hangers, emergency dispatch, |
  • | and local fire departments notified 24 to 48 hours prior. |
  • | 2. Line Isolation: Isolate target sewer segment using sandbags or |
  • | pneumatic expandable pipe plugs at adjacent manholes. |
  • | 3. Smoke Injection: Position high-capacity blower (1,500–4,000 CFM) |
  • | over manhole; ignite non-toxic zinc chloride/paraffin smoke candle |
  • | or liquid smoke generator to pressurize pipe with white smoke. |
  • | 4. Surface Documentation: Field crews walk line inspecting and mapping |
  • | smoke emerging from downspouts, yard drains, pavement, or cleanouts. |
  • +-------------------------------------------------------------------------+
  • Mandatory Public Notification & Safety Protocols

Pre-Notification: Residents must receive written notification 24 to 48 hours in advance. Individuals with chronic respiratory ailments (asthma, COPD) must be identified so special precautions can be taken.

Emergency Dispatch Coordination: Local 911 dispatch centers and fire departments must be briefed on the exact testing schedule every morning to prevent false structure fire responses.

Indoor Smoke Entry: Non-toxic white smoke should never enter a residence. If smoke does appear indoors, it indicates a dry plumbing trap (P-trap) , a fractured internal drain-waste-vent (DWV) pipe, or an unvented fixture. Operators must inform the building owner immediately, as these defects allow lethal, flammable sewer gas ( H 2 S \text{H}_2\text{S} H 2 ​ S , CH 4 \text{CH}_4 CH 4 ​ ) into occupied living spaces.

4. Dye Testing & Cross-Connection Tracing

Dye testing confirms suspected direct hydraulic cross-connections between storm drainage structures and sanitary collection networks:

Procedure: Non-toxic, biodegradable fluorescent tracing dyes (e.g., Fluorescein / Uranine or Rhodamine WT) are introduced into suspected roof downspouts, commercial area drains, parking lot catch basins, or stream beds and flushed with clean water from a water tanker.

Detection: Downstream sanitary manholes are visually monitored or sampled with handheld fluorometers. The appearance of intense green/red color confirms a direct illicit physical cross-connection.

5. Robotic CCTV Inspection & NASSCO PACP Standards

Internal pipe condition assessment relies on self-propelled robotic Closed-Circuit Television (CCTV) crawler tractors equipped with high-definition, pan-tilt-zoom color cameras, laser profiling rings, and auxiliary LED lighting.

NASSCO PACP Standardized Defect Scoring

The National Association of Sewer Service Companies (NASSCO) Pipeline Assessment Certification Program (PACP) provides a uniform, objective coding standard for sewer defects: +-------------------------------------------------------------------------+

  • | NASSCO PACP DEFECT SEVERITY SCALE |
  • +-------------------------------------------------------------------------+
  • | Grade 1: Minor / Blemish | Minor defect; failure unlikely in 20+ yrs|
  • | Grade 2: Light Defect | Defect not currently progressing; 10–20 yr|
  • | Grade 3: Moderate Defect | Significant deterioration; 5–10 yr life |
  • | Grade 4: Severe Defect | High risk of collapse within 1 to 5 yrs |
  • | Grade 5: Most Severe Defect | Pipe collapsed or collapse imminent |
  • +-------------------------------------------------------------------------+
  • Defect Classifications

Structural Defects (PACP-S): Cracks (longitudinal, circumferential, spiral), fractures, broken pipe walls, missing pipe fragments, hole in pipe with soil visible, deformed/deflected PVC pipe ( > 7.5 % > 7.5\% > 7.5% ), dropped joints, collapsed pipe.

Operation & Maintenance Defects (PACP-OM): Root intrusion (fine hair roots, medium root masses, taproots), grease coatings/plugs, mineral encrustation/calcium scaling, settled debris/grit, protruding lateral taps (hammer taps), standing water / pipe sags (bellies).

Multi-Sensor Inspection Enhancements

Laser Profiling: Projects a circular laser ring onto the pipe wall to calculate exact cross-sectional ovality, proving whether flexible PVC pipe exceeds the maximum allowable 5% deflection threshold.

Sonar Profiling: Utilizes high-frequency acoustic sound waves beneath the waterline to calculate the exact volume of settled grit, sand, and sludge in surcharged or deep interceptor pipes without requiring bypass pumping.

  • 6. Worked Inspection & I&I Calculations
  • Worked Example 7.3.1: Inflow Volume Calculation from Hydrograph Surcharge

A municipal collection basin serving 10,000 residents has a baseline dry-weather flow of 1.0 MGD ( 694.4 gpm 694.4\text{ gpm} 694.4 gpm ). During a high-intensity summer thunderstorm, an area-velocity flow meter at the basin outlet records a peak flow spike reaching 4.5 MGD ( 3 , 125 gpm 3,125\text{ gpm} 3 , 125 gpm ). The storm hydrograph surcharge lasts for a total duration of 4.0 hours , averaging 3.0 MGD ( 2 , 083.3 gpm 2,083.3\text{ gpm} 2 , 083.3 gpm ) over that period. Calculate the total volume of direct stormwater Inflow (in gallons) that entered the collection network.

Step 1: Calculate the extraneous Inflow flow rate above baseline dry-weather flow: Average Total Storm Flow = 3.0 MGD \text{Average Total Storm Flow} = 3.0\text{ MGD} Average Total Storm Flow = 3.0 MGD Baseline Sanitary Dry-Weather Flow = 1.0 MGD \text{Baseline Sanitary Dry-Weather Flow} = 1.0\text{ MGD} Baseline Sanitary Dry-Weather Flow = 1.0 MGD Extraneous Inflow Rate = 3.0 MGD − 1.0 MGD = 2.0 MGD \text{Extraneous Inflow Rate} = 3.0\text{ MGD} - 1.0\text{ MGD} = 2.0\text{ MGD} Extraneous Inflow Rate = 3.0 MGD − 1.0 MGD = 2.0 MGD

Step 2: Convert Inflow rate from MGD to gallons per hour: Inflow Rate = 2 , 000 , 000 gallons 24 hours = 83 , 333.3 gallons/hour \text{Inflow Rate} = \frac{2,000,000\text{ gallons}}{24\text{ hours}} = 83,333.3\text{ gallons/hour} Inflow Rate = 24 hours 2 , 000 , 000 gallons ​ = 83 , 333.3 gallons/hour

Step 3: Calculate total extraneous Inflow volume over the 4.0-hour event: Total Inflow Volume = 83 , 333.3 gal/hr × 4.0 hours = 333 , 333 gallons \text{Total Inflow Volume} = 83,333.3\text{ gal/hr} \times 4.0\text{ hours} = 333,333\text{ gallons} Total Inflow Volume = 83 , 333.3 gal/hr × 4.0 hours = 333 , 333 gallons

Worked Example 7.3.2: Groundwater Infiltration Baseline Evaluation

A sanitary sewer meter basin records an Average Daily Flow (ADF) of 800,000 gallons/day (0.80 MGD). Between 2:00 AM and 5:00 AM during a dry-weather period with zero industrial discharges, the meter records a steady flow rate of 240 gpm . Determine if this basin exceeds the 30% infiltration screening threshold.

Step 1: Convert the 2:00 AM to 5:00 AM nighttime flow rate to an equivalent 24-hour daily rate: Nighttime Flow Rate = 240 gpm × 1 , 440 minutes/day = 345 , 600 gallons/day \text{Nighttime Flow Rate} = 240\text{ gpm} \times 1,440\text{ minutes/day} = 345,600\text{ gallons/day} Nighttime Flow Rate = 240 gpm × 1 , 440 minutes/day = 345 , 600 gallons/day

Step 2: Calculate nighttime flow as a percentage of Average Daily Flow: Percentage = ( 345 , 600 gal/day 800 , 000 gal/day ) × 100 = 43.2 % \text{Percentage} = \left( \frac{345,600\text{ gal/day}}{800,000\text{ gal/day}} \right) \times 100 = 43.2\% Percentage = ( 800 , 000 gal/day 345 , 600 gal/day ​ ) × 100 = 43.2%

Conclusion: Because 43.2% exceeds the 25% to 30% screening threshold, this collection sub-basin is experiencing severe groundwater infiltration and should be prioritized for CCTV robotic inspection and joint sealing.