Study guide
9.1 Biometry Overview
COA Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: COA Orientation and Exam Strategy
1.1 Current COA Exam Facts 1.2 Eligibility, Application, and Scheduling 1.3 Blueprint Domains and Weighting 1.4 Question Style and Score Report Thinking 1.5 Study Calendar and Practice Plan
2 Chapter 2: History and Documentation
2.1 History and Documentation Overview 2.2 Core Workflows and Decision Points 2.3 Scenario Practice for History and Documentation 2.4 Common Traps in History and Documentation 2.5 Practice Drills and Readiness Markers
3 Chapter 3: Visual Assessment
3.1 Visual Assessment Overview 3.2 Core Workflows and Decision Points 3.3 Scenario Practice for Visual Assessment 3.4 Common Traps in Visual Assessment 3.5 Practice Drills and Readiness Markers
4 Chapter 4: Visual Field Testing
4.1 Visual Field Testing Overview 4.2 Core Workflows and Decision Points 4.3 Scenario Practice for Visual Field Testing 4.4 Common Traps in Visual Field Testing 4.5 Practice Drills and Readiness Markers
5 Chapter 5: Pupil Assessment
5.1 Pupil Assessment Overview 5.2 Core Workflows and Decision Points 5.3 Scenario Practice for Pupil Assessment 5.4 Common Traps in Pupil Assessment 5.5 Practice Drills and Readiness Markers
6 Chapter 6: Tonometry
6.1 Tonometry Overview 6.2 Core Workflows and Decision Points 6.3 Scenario Practice for Tonometry 6.4 Common Traps in Tonometry 6.5 Practice Drills and Readiness Markers
7 Chapter 7: Keratometry
7.1 Keratometry Overview 7.2 Core Workflows and Decision Points 7.3 Scenario Practice for Keratometry 7.4 Common Traps in Keratometry 7.5 Practice Drills and Readiness Markers
8 Chapter 8: Lensometry
8.1 Lensometry Overview 8.2 Core Workflows and Decision Points 8.3 Scenario Practice for Lensometry 8.4 Common Traps in Lensometry 8.5 Practice Drills and Readiness Markers
9 Chapter 9: Biometry
9.1 Biometry Overview 9.2 Core Workflows and Decision Points 9.3 Scenario Practice for Biometry 9.4 Common Traps in Biometry 9.5 Practice Drills and Readiness Markers
10 Chapter 10: Diagnostic Ultrasound
10.1 Diagnostic Ultrasound Overview 10.2 Core Workflows and Decision Points 10.3 Scenario Practice for Diagnostic Ultrasound 10.4 Common Traps in Diagnostic Ultrasound 10.5 Practice Drills and Readiness Markers
11 Chapter 11: Supplemental Testing
11.1 Supplemental Testing Overview 11.2 Core Workflows and Decision Points 11.3 Scenario Practice for Supplemental Testing 11.4 Common Traps in Supplemental Testing 11.5 Practice Drills and Readiness Markers
12 Chapter 12: Microbiology
12.1 Microbiology Overview 12.2 Core Workflows and Decision Points 12.3 Scenario Practice for Microbiology 12.4 Common Traps in Microbiology 12.5 Practice Drills and Readiness Markers
13 Chapter 13: Pharmacology
13.1 Pharmacology Overview 13.2 Mydriatics, Cycloplegics, and Anesthetics 13.3 Glaucoma, Anti-Infective, and Anti-Inflammatory Agents 13.4 Stains, Instillation Technique, and Safety Traps 13.5 Practice Drills and Readiness Markers
14 Chapter 14: Surgical Assisting
14.1 Surgical Assisting Overview 14.2 Core Workflows and Decision Points 14.3 Scenario Practice for Surgical Assisting 14.4 Common Traps in Surgical Assisting 14.5 Practice Drills and Readiness Markers
15 Chapter 15: Ophthalmic Patient Services and Education
15.1 Ophthalmic Patient Services and Education Overview 15.2 Core Workflows and Decision Points 15.3 Scenario Practice for Ophthalmic Patient Services and Education 15.4 Common Traps in Ophthalmic Patient Services and Education 15.5 Practice Drills and Readiness Markers
16 Chapter 16: Optics and Spectacles
16.1 Optics and Spectacles Overview 16.2 Core Workflows and Decision Points 16.3 Scenario Practice for Optics and Spectacles 16.4 Common Traps in Optics and Spectacles 16.5 Practice Drills and Readiness Markers
17 Chapter 17: Contact Lenses
17.1 Contact Lens Types, Parameters, and Oxygen 17.2 Fitting Workflows: K Readings, Tear Lens, and the SAM/FAP Rule 17.3 Insertion, Removal, Care Systems, and Wear Schedules 17.4 Complications: Hypoxia, Infiltrates, and Corneal Ulcers 17.5 Specialty Lenses, Multifocals, and Readiness Drills
18 Chapter 18: Equipment Maintenance and Repair
18.1 Equipment Maintenance and Repair Overview 18.2 Core Workflows and Decision Points 18.3 Scenario Practice for Equipment Maintenance and Repair 18.4 Common Traps in Equipment Maintenance and Repair 18.5 Practice Drills and Readiness Markers
19 Chapter 19: Medical Ethics, Legal, and Regulatory Issues
19.1 Medical Ethics, Legal, and Regulatory Issues Overview 19.2 Core Workflows and Decision Points 19.3 Scenario Practice for Medical Ethics, Legal, and Regulatory Issues 19.4 Common Traps in Medical Ethics, Legal, and Regulatory Issues 19.5 Practice Drills and Readiness Markers
20 Chapter 20: General Medical Knowledge
20.1 General Medical Knowledge Overview 20.2 Medical Terminology, Anatomy, and Physiology 20.3 Systemic Disease with Ocular Manifestations 20.4 Pharmacology and Medical Emergencies 20.5 Microbiology, Infection Control, and Readiness Drills
21 Chapter 21: Refraction
21.1 Refraction Overview 21.2 Core Workflows and Decision Points 21.3 Scenario Practice for Refraction 21.4 Common Traps in Refraction 21.5 Practice Drills and Readiness Markers
22 Chapter 22: Ophthalmic Imaging
22.1 Ophthalmic Imaging Overview 22.2 Core Workflows and Decision Points 22.3 Scenario Practice for Ophthalmic Imaging 22.4 Common Traps in Ophthalmic Imaging 22.5 Practice Drills and Readiness Markers
23 Chapter 23: Ocular Motility Testing
23.1 Ocular Motility Testing Overview 23.2 Core Workflows and Decision Points 23.3 Scenario Practice for Ocular Motility Testing 23.4 Common Traps in Ocular Motility Testing 23.5 Practice Drills and Readiness Markers
24 Chapter 24: Final Review and Test Day
24.1 Timed Practice Strategy 24.2 Last-Week Review Map 24.3 Exam-Day Checklist 24.4 After the Exam and Next Steps
9.1 Biometry Overview
Key Takeaways Explain This Topic AI
Biometry is the measurement of ocular dimensions, axial length, keratometry, and anterior chamber depth, used to calculate intraocular lens power before cataract surgery.
Axial length contributes roughly 54 percent of the refractive error in an IOL calculation, so a 1 mm error shifts the postoperative refraction by about 2.5 to 3.0 diopters.
Optical biometry, partial coherence interferometry, is more accurate and reproducible than applanation A-scan ultrasound and is now the clinical standard.
On the COA exam, biometry and diagnostic ultrasound questions reward knowing why a measurement is wrong, not just the definition of a term.
Last updated: June 2026
9.1 Biometry Overview
Biometry is the set of measurements an ophthalmic technician takes to calculate the intraocular lens (IOL) power implanted during cataract surgery. The three measurements that drive nearly every IOL formula are axial length (AL) , the front-to-back length of the eye in millimeters; keratometry (K) , the corneal curvature in diopters; and anterior chamber depth (ACD) , the distance from the cornea to the lens. Get any of these wrong and the patient ends up needing glasses they were promised they would not need, the most common cause of a refractive surprise after cataract surgery.
Why precision matters
The single largest source of postoperative refractive error is axial length. As a working rule, a 1 mm error in axial length shifts the final spectacle refraction by roughly 2.5 to 3.0 diopters . Because the average eye is about 23.5 mm long, even a 0.3 mm error, the kind a sloppy applanation A-scan produces, can leave a patient a diopter off target. Keratometry is the second largest contributor; a 1 D error in K produces about 1 D of refractive error. ACD matters most in short and long eyes.
- Measurement Average value Approx. effect of error
- Axial length (AL) 23.5 mm (range ~22-25) 1 mm error ≈ 2.5-3.0 D
- Keratometry (K) 43-44 D / 7.5-8.0 mm radius 1 D K error ≈ 1 D refraction
- Anterior chamber depth (ACD) 3.0-3.5 mm Affects effective lens position
- Two ways to measure axial length
Optical biometry uses partial coherence interferometry (PCI) , an infrared 780 nm light beam, in devices such as the IOLMaster. It is non-contact, does not touch or compress the cornea, and is far more reproducible, the longitudinal resolution of light is roughly eight times finer than a 10 MHz ultrasound wave. Optical biometry has become the clinical standard for routine cataract cases.
Ultrasound A-scan biometry uses a 10 MHz sound wave. It is still required when optical biometry cannot acquire a reading, for example a dense (mature) cataract , a vitreous hemorrhage, or a corneal scar that blocks the light beam. A-scan comes in two flavors: applanation (contact) , where the probe touches the cornea, and immersion , where a fluid-filled scleral shell separates the probe from the cornea.
How biometry appears on the COA exam
The COA blueprint folds these topics into a small biometry slice plus diagnostic ultrasound. Expect applied items: a stem describes a measurement workflow or an error and asks what caused it or what to do next. Typical traps include forgetting that applanation falsely shortens the eye, confusing axial length with corneal thickness (pachymetry), or selecting the wrong A-scan mode for a phakic versus pseudophakic versus silicone-oil-filled eye. Read every stem for the eye state, the device, and the immediate task before choosing.
Use the official IJCAHPO content outline and candidate handbook to confirm current domain weights and the Registered Ophthalmic Ultrasound Biographer (ROUB) scope before relying on secondary summaries: IJCAHPO COA Certification Page .
What the IOL formula actually uses
Every modern IOL power formula combines the same core inputs in different mathematical ways. The earliest regression formula was the SRK formula, written as P = A − 2.5L − 0.9K, where P is implant power, A is the lens-specific A-constant , L is axial length, and K is average keratometry. You will not be asked to compute it by hand, but the form makes the lesson concrete: axial length (L) carries a coefficient of 2.5, so every millimeter swings power by 2.5 D, and keratometry (K) carries 0.9, so each diopter of K moves power by about 0.9 D.
Theoretical and ray-tracing formulas, Hoffer Q, Holladay 1 and 2, the SRK/T, and the Barrett Universal II , refine the estimate of effective lens position (ELP) , where the IOL will sit in the eye, by adding ACD, lens thickness, and white-to-white corneal diameter.
Matching the formula to the eye
A practical clinic rule is that formula accuracy depends on axial length:
- Short eyes (AL under ~22 mm): Hoffer Q or Barrett tend to perform best
- Average eyes (~22-26 mm): most modern formulas perform well
Long eyes (AL over ~26 mm): SRK/T, Barrett, and axial-length-adjusted formulas reduce the hyperopic surprise that older formulas produce in myopic eyes
The technician's job is not to pick the formula, that is the surgeon's call, but to deliver inputs clean enough that the chosen formula can succeed. A flawless formula cannot rescue a compressed-cornea axial length or a keratometry taken on a dried-out tear film.
Keratometry in detail
Keratometry measures the curvature of the central cornea in two principal meridians, reporting each as a power in diopters or a radius of curvature in millimeters. A normal cornea is roughly 43 to 44 diopters, equivalent to about a 7.5 to 7.8 mm radius; remember that a flatter cornea has a longer radius and lower power , while a steeper cornea has a shorter radius and higher power. The difference between the two meridians is the corneal astigmatism , and the orientation of the steeper meridian is its axis.
Optical biometers measure keratometry automatically by projecting light rings onto the cornea and measuring their reflected size, the same principle as a manual keratometer or a corneal topographer. The technician confirms the rings are crisp and circular; a broken or distorted mire reflection signals dry eye, irregular cornea, or poor fixation and means the K value is unreliable.
Anterior chamber depth and effective lens position
Anterior chamber depth is measured from the corneal epithelium (or endothelium, depending on the device convention) to the front of the natural lens, normally 3.0 to 3.5 mm. It matters because modern formulas use it to predict the effective lens position, where the implanted IOL will finally rest. A shallower chamber tends to push the implant forward, increasing its effective power, so ignoring ACD in short or unusually shallow eyes is a known source of error. White-to-white corneal diameter (the horizontal visible iris diameter) and lens thickness feed the same ELP estimate in advanced formulas such as Holladay 2 and Barrett.