Study guide
4.2 Core Workflows and Decision Points
COA Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: COA Orientation and Exam Strategy
1.1 Current COA Exam Facts 1.2 Eligibility, Application, and Scheduling 1.3 Blueprint Domains and Weighting 1.4 Question Style and Score Report Thinking 1.5 Study Calendar and Practice Plan
2 Chapter 2: History and Documentation
2.1 History and Documentation Overview 2.2 Core Workflows and Decision Points 2.3 Scenario Practice for History and Documentation 2.4 Common Traps in History and Documentation 2.5 Practice Drills and Readiness Markers
3 Chapter 3: Visual Assessment
3.1 Visual Assessment Overview 3.2 Core Workflows and Decision Points 3.3 Scenario Practice for Visual Assessment 3.4 Common Traps in Visual Assessment 3.5 Practice Drills and Readiness Markers
4 Chapter 4: Visual Field Testing
4.1 Visual Field Testing Overview 4.2 Core Workflows and Decision Points 4.3 Scenario Practice for Visual Field Testing 4.4 Common Traps in Visual Field Testing 4.5 Practice Drills and Readiness Markers
5 Chapter 5: Pupil Assessment
5.1 Pupil Assessment Overview 5.2 Core Workflows and Decision Points 5.3 Scenario Practice for Pupil Assessment 5.4 Common Traps in Pupil Assessment 5.5 Practice Drills and Readiness Markers
6 Chapter 6: Tonometry
6.1 Tonometry Overview 6.2 Core Workflows and Decision Points 6.3 Scenario Practice for Tonometry 6.4 Common Traps in Tonometry 6.5 Practice Drills and Readiness Markers
7 Chapter 7: Keratometry
7.1 Keratometry Overview 7.2 Core Workflows and Decision Points 7.3 Scenario Practice for Keratometry 7.4 Common Traps in Keratometry 7.5 Practice Drills and Readiness Markers
8 Chapter 8: Lensometry
8.1 Lensometry Overview 8.2 Core Workflows and Decision Points 8.3 Scenario Practice for Lensometry 8.4 Common Traps in Lensometry 8.5 Practice Drills and Readiness Markers
9 Chapter 9: Biometry
9.1 Biometry Overview 9.2 Core Workflows and Decision Points 9.3 Scenario Practice for Biometry 9.4 Common Traps in Biometry 9.5 Practice Drills and Readiness Markers
10 Chapter 10: Diagnostic Ultrasound
10.1 Diagnostic Ultrasound Overview 10.2 Core Workflows and Decision Points 10.3 Scenario Practice for Diagnostic Ultrasound 10.4 Common Traps in Diagnostic Ultrasound 10.5 Practice Drills and Readiness Markers
11 Chapter 11: Supplemental Testing
11.1 Supplemental Testing Overview 11.2 Core Workflows and Decision Points 11.3 Scenario Practice for Supplemental Testing 11.4 Common Traps in Supplemental Testing 11.5 Practice Drills and Readiness Markers
12 Chapter 12: Microbiology
12.1 Microbiology Overview 12.2 Core Workflows and Decision Points 12.3 Scenario Practice for Microbiology 12.4 Common Traps in Microbiology 12.5 Practice Drills and Readiness Markers
13 Chapter 13: Pharmacology
13.1 Pharmacology Overview 13.2 Mydriatics, Cycloplegics, and Anesthetics 13.3 Glaucoma, Anti-Infective, and Anti-Inflammatory Agents 13.4 Stains, Instillation Technique, and Safety Traps 13.5 Practice Drills and Readiness Markers
14 Chapter 14: Surgical Assisting
14.1 Surgical Assisting Overview 14.2 Core Workflows and Decision Points 14.3 Scenario Practice for Surgical Assisting 14.4 Common Traps in Surgical Assisting 14.5 Practice Drills and Readiness Markers
15 Chapter 15: Ophthalmic Patient Services and Education
15.1 Ophthalmic Patient Services and Education Overview 15.2 Core Workflows and Decision Points 15.3 Scenario Practice for Ophthalmic Patient Services and Education 15.4 Common Traps in Ophthalmic Patient Services and Education 15.5 Practice Drills and Readiness Markers
16 Chapter 16: Optics and Spectacles
16.1 Optics and Spectacles Overview 16.2 Core Workflows and Decision Points 16.3 Scenario Practice for Optics and Spectacles 16.4 Common Traps in Optics and Spectacles 16.5 Practice Drills and Readiness Markers
17 Chapter 17: Contact Lenses
17.1 Contact Lens Types, Parameters, and Oxygen 17.2 Fitting Workflows: K Readings, Tear Lens, and the SAM/FAP Rule 17.3 Insertion, Removal, Care Systems, and Wear Schedules 17.4 Complications: Hypoxia, Infiltrates, and Corneal Ulcers 17.5 Specialty Lenses, Multifocals, and Readiness Drills
18 Chapter 18: Equipment Maintenance and Repair
18.1 Equipment Maintenance and Repair Overview 18.2 Core Workflows and Decision Points 18.3 Scenario Practice for Equipment Maintenance and Repair 18.4 Common Traps in Equipment Maintenance and Repair 18.5 Practice Drills and Readiness Markers
19 Chapter 19: Medical Ethics, Legal, and Regulatory Issues
19.1 Medical Ethics, Legal, and Regulatory Issues Overview 19.2 Core Workflows and Decision Points 19.3 Scenario Practice for Medical Ethics, Legal, and Regulatory Issues 19.4 Common Traps in Medical Ethics, Legal, and Regulatory Issues 19.5 Practice Drills and Readiness Markers
20 Chapter 20: General Medical Knowledge
20.1 General Medical Knowledge Overview 20.2 Medical Terminology, Anatomy, and Physiology 20.3 Systemic Disease with Ocular Manifestations 20.4 Pharmacology and Medical Emergencies 20.5 Microbiology, Infection Control, and Readiness Drills
21 Chapter 21: Refraction
21.1 Refraction Overview 21.2 Core Workflows and Decision Points 21.3 Scenario Practice for Refraction 21.4 Common Traps in Refraction 21.5 Practice Drills and Readiness Markers
22 Chapter 22: Ophthalmic Imaging
22.1 Ophthalmic Imaging Overview 22.2 Core Workflows and Decision Points 22.3 Scenario Practice for Ophthalmic Imaging 22.4 Common Traps in Ophthalmic Imaging 22.5 Practice Drills and Readiness Markers
23 Chapter 23: Ocular Motility Testing
23.1 Ocular Motility Testing Overview 23.2 Core Workflows and Decision Points 23.3 Scenario Practice for Ocular Motility Testing 23.4 Common Traps in Ocular Motility Testing 23.5 Practice Drills and Readiness Markers
24 Chapter 24: Final Review and Test Day
24.1 Timed Practice Strategy 24.2 Last-Week Review Map 24.3 Exam-Day Checklist 24.4 After the Exam and Next Steps
4.2 Core Workflows and Decision Points
Key Takeaways Explain This Topic AI
Refractive correction matters: add the appropriate near add to the patient's distance Rx for central 24-2/30-2 fields, or test results will show false generalized depression.
Heijl-Krakau fixation losses should stay below 20 percent; false positives and false negatives below 33 percent (SITA flags false positives above about 15 percent).
False positives make the field look better than reality (trigger-happy patient); false negatives and high fixation loss make it look worse.
Set up the patient correctly first: correct eye patched, head positioned, fixation explained, and a practice run before the recorded test.
Last updated: June 2026
4.2 Core Workflows and Decision Points
A reliable automated field begins long before the first stimulus. The COA controls setup, and most unreliable tests trace back to a setup error rather than the patient. Treat every field as a small procedure with a fixed order: correct the refraction, position the head, explain fixation, run a practice, then test - and read the reliability header before you trust the map.
Step-by-step Humphrey setup
Enter demographics and pupil size. Age normalizes the result; a pupil under ~2 mm can cause artifactual depression.
Add the correct trial lens. Use the patient's distance refraction plus the appropriate near add for the bowl distance (about +2.50 to +3.25 for presbyopes on the 24-2/30-2). Without the near add, the whole field reads dim - a classic artifactual generalized depression .
Patch the non-tested eye completely; light leaks cause false positives.
Position the patient. Forehead against the bar, chin in the rest, eye centered on the monitor camera. Keep the lens close to the eye to avoid a lens-rim artifact (a dense ring scotoma in the periphery).
Explain fixation. The patient stares at the central target and presses the button whenever a light is seen, even a faint one - and does not chase the lights.
Run a brief demo/practice , then start the recorded test.
Reading the four reliability indices
The printout header reports reliability before the physician trusts the map. Memorize these cutoffs.
- Index What it means Acceptable limit Effect if high
- Fixation losses (FL) Responses to a stimulus in the blind spot (Heijl-Krakau) < 20% Field shifted/unreliable
False positives (FP) Button pressed with no stimulus (catch trial) < 33% (SITA flags ~15%) Field looks too good; white scotomas
- False negatives (FN) Missed a bright stimulus in an already-seen area < 33% Field looks too bad
- Test duration / GHT Speed of test; Glaucoma Hemifield Test summary n/a Fatigue, cloverleaf pattern
- How fixation losses are measured
The Humphrey uses the Heijl-Krakau method : periodically, instead of testing a normal point, the machine projects a stimulus into the patient's mapped physiologic blind spot. Because there are no photoreceptors there, a properly fixating patient should never see it. If the patient presses the button, the eye must have moved off the central target, and the machine tallies a fixation loss. This is why correctly plotting the blind spot at the start matters - a mis-plotted blind spot inflates the fixation-loss count and can wrongly condemn a good test.
The decision rule
High false positives mean a trigger-happy patient who presses without seeing a light; sensitivity values are inflated and the field looks better than it truly is. White, supranormal-looking points appear. Reinstruct ("press only when you actually see a light") and repeat.
High false negatives or high fixation losses mean the field looks worse than reality, usually from fatigue, inattention, drowsiness, or poor head positioning. Offer a short break, reposition the patient, re-explain fixation, and repeat.
A cloverleaf pattern - seeing only the four central points the machine tests first, with the rest of the field blank - indicates the patient understood the task initially but stopped responding partway through, often from fatigue or confusion.
Confrontation and Amsler workflows
Not every field is automated. For confrontation testing , you sit about one meter in front of the patient, have them cover one eye while you cover your opposite eye, and present fingers or a target in each of the four quadrants, asking the patient to count fingers or say when they see motion. Your own normal field is the reference standard - if you see the target but the patient does not, a defect in that quadrant is likely.
For the Amsler grid , the patient holds the grid at normal reading distance, wears their reading correction, covers one eye, and fixates the central dot while reporting any missing, blurred, or wavy lines; wavy lines (metamorphopsia) or a central gap suggest macular disease and warrant referral for OCT or dilated exam.
Documentation and handoff
Record the eye tested, pupil size, the trial-lens power used, the test pattern and strategy, and any reliability concerns directly with the printout. If you repeated a test, keep both runs so the physician can see the artifact and your correction. Never silently discard a bad field; the fact that the first attempt was unreliable is itself clinically useful information about the patient's ability to perform the test, and the physician may need it to judge whether a future field is comparable.
Worked example
A 68-year-old glaucoma patient finishes a 24-2 SITA test. The header shows fixation losses 5 percent, false positives 28 percent, false negatives 8 percent, and several scattered white supranormal points across the map. Two of the three indices are fine, but false positives are elevated above the SITA flag of roughly 15 percent, so the result overstates the patient's true vision. The correct action is to reinstruct the patient and repeat the test, not to record it as an improving field. Reporting an inflated field as genuine improvement could wrongly suggest the glaucoma is stable and delay needed treatment changes.