Study guide

7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off

IJCAHPO Certified Ophthalmic Medical Technologist COMT

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements

1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification

2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology

2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway

3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety

3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety

4 Chapter 4: Ophthalmic History Taking & Clinical Documentation

4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record

5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction

6 Chapter 6: Tonometry, Keratometry & Pupil Measurement

6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria

7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis

7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment

8 Chapter 8: Refraction, Retinoscopy & Refinement

8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations

9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics

9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations

10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy

10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training

11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation

11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing

12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique

12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics

13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols

13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials

14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)

14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics

15 Chapter 15: Fluorescein Angiography Principles & Technique

15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management

16 Chapter 16: Angiographic Interpretation & Pathology

16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology

17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography

17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers

18 Chapter 18: Ophthalmic Photography & Videography

18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management

19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)

19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging

20 Chapter 20: Biometry, Topography & Corneal Analysis

20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth

21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting

21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems

22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications

22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis

23 Chapter 23: Ocular Pharmacology

23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF

24 Chapter 24: Microbiology & Ocular Specimen Collection

24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection

25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery

25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs

26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery

26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol

27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures

27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)

28 Chapter 28: Ophthalmic Patient Services & Education

28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support

29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance

29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements

7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off

Key Takeaways Explain This Topic AI

Prism is present when the lensometer mire target does not centre on the reticle crosshair.

Base direction is named by where the mire target displaces: the base is opposite the direction of target displacement on a standard reticle.

One prism dioptre displaces light 1 cm at 1 metre; the reticle rings are usually spaced at 1 prism dioptre intervals.

Fresnel press-on prisms are temporary, come in powers up to about 40 prism dioptres, and reduce acuity and contrast.

Slab-off is identified as a faint horizontal line across the lower lens and is placed on the more minus lens, adding base-up across the reading portion.

Last updated: September 2026

Detecting prism on the lensometer

When a lens contains prism, the mire target will not centre on the reticle crosshair no matter how the lens is moved, because the prism deviates the beam. The reticle carries concentric rings, conventionally spaced at 1 prism dioptre per ring, so the amount of displacement can be counted directly.

Procedure for measuring prism at a specified point:

Focus the eyepiece and neutralise the lens as usual.

Mark the patient's pupil position on the lens — or, when verifying against a prescription, position the lens so the reference point specified (usually the patient's pupil centre, or the lens's stated major reference point) sits over the aperture.

Read how many rings the mire target has moved from the reticle centre. That number is the prism power in prism dioptres.

Read the direction of displacement.

Base direction convention. On a standard lensometer reticle the mire target displaces toward the apex , so the base is in the opposite direction from the target displacement . A target displaced upward means base down ; displaced toward the nose means base out for that eye. Because the nasal side differs between right and left lenses, always state base direction as up, down, in or out relative to that eye , and record which eye.

A reliable sanity check: light is bent toward the base and the image shifts toward the apex . If your recorded base direction would move the image the wrong way for the patient's deviation, you have the sign reversed.

Prism dioptre definition

One prism dioptre (Δ) displaces a ray 1 centimetre at a distance of 1 metre , approximately 0.57 degrees. Prism is prescribed to shift the retinal image so a deviated eye can fuse without moving, and it is written with both the power and the base direction , for example "3Δ base out OD."

Intentional ground-in prism versus unwanted decentration prism

Not all prism in a pair of spectacles was prescribed.

Ground-in prism is prescribed prism manufactured into the lens. It is present at the major reference point by design.

Decentration prism is prism the patient experiences because the optical centre of the lens does not sit in front of the pupil. Its magnitude follows Prentice's rule (covered in detail in the clinical optics section): prism in prism dioptres equals the lens power in dioptres multiplied by the decentration in centimetres.

The practical question when a patient complains about new spectacles is which one you are looking at . Mark the optical centre with the lensometer's marking pins, then compare the marks with the patient's actual pupil positions while they wear the frame. If the marks sit in front of the pupils and prism is still present, it is ground-in. If the marks sit off-pupil and the prism disappears when the mires are recentred at the optical centre, the prism is decentration.

Splitting prism. Prescribed prism is commonly divided between the two eyes — 4Δ base out is often dispensed as 2Δ base out in each eye. When verifying, measure each lens and add the two:

  • Combination Result
  • 2Δ base out OD + 2Δ base out OS 4Δ base out total
  • 3Δ base up OD + 3Δ base down OS 6Δ vertical total
  • 2Δ base in OD + 3Δ base out OS 1Δ base out net (opposing horizontal directions subtract)

Horizontal prism of the same name (both base in, or both base out) adds . Vertical prism is opposite by nature — base up in one eye and base down in the other are additive for the same reason.

Fresnel press-on prisms

A Fresnel prism is a thin flexible polyvinyl chloride membrane of small parallel prismatic grooves that reproduce the deviation of a thick prism at a fraction of the weight and thickness.

  • Feature Detail
  • Powers Commonly 1Δ to 40Δ
  • Attachment Cut to the lens shape and applied to the back surface with water; adheres by surface tension
  • Orientation Grooves run perpendicular to the base-apex line ; the smooth side goes against the lens

Advantages Light, thin, inexpensive, removable, allows high powers that would be impossible ground in, ideal for a changing deviation

Disadvantages Reduces acuity and contrast (roughly one to two Snellen lines, worse at higher powers), visible to observers, collects debris, can peel

Typical indications: an acute cranial nerve palsy where the deviation is expected to change, a trial of prism before committing to ground-in prism, deviations too large to grind, and field expansion prisms in hemianopia.

Because a Fresnel degrades image quality, it is a temporary or trial solution in most cases. Ground-in prism is preferred once a deviation is stable, generally after several months without change.

Recognising slab-off

Slab-off (bicentric grinding) corrects the vertical prismatic imbalance that an anisometropic presbyope experiences in downgaze. Identifying it is a verification task.

Look for a faint horizontal line running across the lower portion of one lens, at about the level of the segment top, visible in oblique light.

Slab-off adds base-up prism across the reading portion.

Conventional (bicentric ground) slab-off is placed on the more minus (or least plus) lens.

Reverse slab-off is moulded into the blank and places base-down prism on the more plus lens, achieving the same balance from the opposite direction. Modern plastic and polycarbonate progressives commonly use reverse slab-off.

When verifying, measure the prism at the distance optical centre and again at the reading level (conventionally 8 to 10 mm below the optical centre). The difference between the two lenses at reading level is the imbalance being corrected. The detailed Prentice's rule arithmetic for calculating that imbalance is worked through in the clinical optics section of this guide.

Recording prism

A complete record states power, base direction and eye , and the point at which it was measured :

  • "OD 2.0Δ base out at the distance optical centre"
  • "OS 3.0Δ base up in the reading portion; faint slab-off line visible"
  • "OU 1.5Δ base in each, total 3.0Δ base in"

An ambiguous entry such as "2Δ" without base or eye is unusable, because base direction determines whether the prism helps or aggravates the patient's deviation.