9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen

IJCAHPO Certified Ophthalmic Medical Technologist COMT

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements

1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification

2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology

2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway

3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety

3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety

4 Chapter 4: Ophthalmic History Taking & Clinical Documentation

4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record

5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction

6 Chapter 6: Tonometry, Keratometry & Pupil Measurement

6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria

7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis

7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment

8 Chapter 8: Refraction, Retinoscopy & Refinement

8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations

9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics

9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations

10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy

10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training

11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation

11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing

12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique

12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics

13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols

13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials

14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)

14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics

15 Chapter 15: Fluorescein Angiography Principles & Technique

15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management

16 Chapter 16: Angiographic Interpretation & Pathology

16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology

17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography

17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers

18 Chapter 18: Ophthalmic Photography & Videography

18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management

19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)

19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging

20 Chapter 20: Biometry, Topography & Corneal Analysis

20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth

21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting

21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems

22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications

22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis

23 Chapter 23: Ocular Pharmacology

23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF

24 Chapter 24: Microbiology & Ocular Specimen Collection

24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection

25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery

25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs

26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery

26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol

27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures

27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)

28 Chapter 28: Ophthalmic Patient Services & Education

28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support

29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance

29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements

9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen

Key Takeaways Explain This Topic AI

The Hirschberg corneal light reflex test provides an objective estimate of ocular misalignment where 1 mm of reflex displacement corresponds to approximately 22 prism diopters (Δ) or 15° of deviation; the Krimsky test refines this by using neutralizing prisms to center the displaced reflex.

The cover-uncover test differentiates manifest strabismus (tropia) from latent misalignment (phoria), while the alternate cover test breaks binocular fusion to measure the total deviation (phoria plus tropia).

The simultaneous prism cover test (SPCT) measures the manifest deviation without dissociating peripheral fusion, making it the gold standard for quantifying microtropia and monofixation syndrome.

Neutralizing prisms must always be positioned with their apex pointing in the direction of ocular deviation and their base oriented opposite to the deviation (Base-Out for esotropia, Base-In for exotropia, Base-Down for hypertropia).

Lancaster Red-Green and Hess Screen tests dissociate the eyes using chromatic red-green filters; on the resulting tangent grid, the paretic eye demonstrates a contracted (smaller) plot, while the contralateral yoke muscle demonstrates an expanded (larger) plot reflecting Hering's innervation.

Last updated: September 2026

Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen

Core Clinical Mandate: Accurate quantification of ocular deviations is the cornerstone of pediatric ophthalmology, neuro-ophthalmic monitoring, and strabismus surgical planning. The Certified Ophthalmic Medical Technologist (COMT) must possess mastery over both objective corneal reflex estimates (Hirschberg and Krimsky) and dissociative subjective/objective cover tests. Understanding how to differentiate a manifest tropia from a latent phoria, how to neutralize complex deviations without prismatic optical artifact, and how to interpret diagnostic tangent screens (Lancaster Red-Green and Hess Screen) is critical for diagnosing cranial neuropathies, orbital restrictions, and monofixation syndrome.

Objective Corneal Light Reflex Testing: Hirschberg & Krimsky

Corneal light reflex tests are indicated when a patient cannot cooperate with subjective cover testing (e.g., infants, toddlers, uncooperative or cognitively impaired adults) or when profound sensory amblyopia/dense suppression prevents foveal fixation.

1. The Hirschberg Test

Principle: A penlight or muscle light is held at 33 cm directly in front of the patient's face along their midline while the patient looks at the light. The examiner observes the position of the First Purkinje-Sanson image (corneal reflection) relative to the center of the pupil in each eye.

Physiological Angle Kappa: In normal eyes, the anatomical pupillary axis does not perfectly coincide with the visual axis. Most individuals exhibit a small positive angle kappa (corneal reflex displaced approximately 0.5 mm nasal to pupil center), which mimics a mild pseudo-exotropia. A negative angle kappa (reflex temporal to center) mimics pseudo-esotropia.

Mathematical Calibration:

1 mm of corneal reflex decentration ≈ \approx ≈ 22 Prism Diopters ( Δ \Delta Δ ) ≈ \approx ≈ 15° of ocular deviation.

0.5 mm decentration: ≈ \approx ≈ 10–11 Δ \Delta Δ ( ≈ \approx ≈ 7°).

2.0 mm decentration (pupillary border in a 4 mm pupil): ≈ \approx ≈ 45 Δ \Delta Δ ( ≈ \approx ≈ 30°).

4.0 mm decentration (mid-iris stroma): ≈ \approx ≈ 90 Δ \Delta Δ .

6.0 mm decentration (corneal limbus): ≈ \approx ≈ 120–135 Δ \Delta Δ ( ≈ \approx ≈ 45°). Hirschberg Corneal Reflex Displacement Matrix:

  • [Temporal Displacement] --> ESOTROPIA (Reflex displaced outward)
  • [Nasal Displacement] --> EXOTROPIA (Reflex displaced inward)
  • [Inferior Displacement] --> HYPERTROPIA (Reflex displaced downward)
  • [Superior Displacement] --> HYPOTROPIA (Reflex displaced upward)
  • 2. The Krimsky Test & Modified Krimsky

Classic Krimsky Method: Prisms are placed in front of the deviating eye until the corneal light reflex is centered identically to that of the fixating eye. Because viewing the corneal reflex through strong prisms introduces distortion and prism reflections, this technique can be technically challenging.

Modified Krimsky Method: Prisms are placed in front of the FIXATING (sound) eye . By forcing the fixating eye to shift toward the prism apex, Hering's Law drives a conjugate version movement in the deviating eye, bringing its corneal reflex into symmetrical central alignment. Prisms are adjusted until the corneal reflections in both eyes are perfectly symmetrical.

3. The Brückner Test

Technique: Performed using a direct ophthalmoscope at 1 meter distance in a darkened room, viewing both pupils simultaneously through the large aperture.

Interpretation: In orthophoric, identical eyes, the retinal red reflexes are symmetrical in color, brightness, and hue. An eye that is strabismic, amblyopic, or has high anisometropia or media opacities displays an asymmetrical, brighter, lighter red-orange reflex due to light reflecting off non-foveal retinal tissue.

Loading diagram... Clinical Diagnostic Pathway for Strabismus Cover Testing

Diagnostic Cover Testing Hierarchy

Cover testing is the definitive standard for evaluating ocular alignment. It requires three clinical prerequisites: binocular vision potential , adequate visual acuity to fixate , and the presentation of an accommodative fixation target (e.g., a single Snellen letter 1–2 lines above threshold acuity) to control accommodation.

1. The Cover-Uncover Test (Detection of Tropias vs. Phorias)

Purpose: Differentiates a tropia (manifest deviation) from a phoria (latent deviation held in check by binocular fusional vergence) .

Protocol:

The patient fixes steadily on the accommodative target.

The examiner covers one eye (e.g., OD) and carefully observes the UNCOVERED eye (OS) .

If OS makes a refixation movement, a tropia is present in OS.

OS moves from temporal to center: Exotropia (XT) .

OS moves from nasal to center: Esotropia (ET) .

OS moves from downward to center: Hypotropia (HypoT) .

OS moves from upward to center: Hypertropia (HyperT) .

If OS remains completely stationary, OS does not have a manifest tropia.

Uncover OD and allow binocular fusion to re-establish for several seconds.

Repeat by covering OS while observing the uncovered OD.

Finally, observe the eye being uncovered : if the covered eye drifted while occluded and rapidly shifts back to straight when uncovered, a phoria is present.

2. The Alternate (Cross) Cover Test

Purpose: Measures the TOTAL deviation (latent phoria plus manifest tropia) by completely disrupting and suspending binocular fusion.

Protocol:

The occluder is shifted rapidly back and forth between the right and left eyes, allowing 2 to 3 seconds of occlusion over each eye without permitting the patient even a fraction of a second of binocular viewing.

The eye being uncovered is observed for its refixation recovery shift.

Because binocular fusion is thoroughly broken, the magnitude of deviation revealed by the alternate cover test represents the total physiological dissociation.

3. The Alternate Prism Cover Test (APCT)

Prism Neutralization: Prisms of progressive dioptric power are placed in front of one eye while the alternate cover test is performed.

Neutralization Endpoint: Prisms are increased until all refixation movement of the eyes ceases completely. Continuing to increase prism power until an initial reversal of movement is observed (overcorrection) confirms the true neutral endpoint.

4. The Simultaneous Prism Cover Test (SPCT)

The Microtropia / Monofixation Dilemma: In patients with monofixation syndrome or microtropia , a tiny manifest tropia (e.g., 4 Δ \Delta Δ to 8 Δ \Delta Δ ) is stabilized by peripheral binocular fusion, alongside a larger underlying latent phoria (e.g., 14 Δ \Delta Δ ). If the technologist performs an alternate cover test, peripheral fusion is broken, revealing the total 14 Δ \Delta Δ deviation, masking the true microtropia!

SPCT Protocol: The neutralizing prism is placed over the deviating eye at the exact same split-second that the fixating eye is covered by the occluder. Because the eyes are never dissociated for prolonged periods, peripheral fusion is preserved, allowing pure measurement of the manifest tropia alone .

Prism Orientation & Neutralization Rules

A prism refracts light toward its base, which causes the perceived optical image to shift toward its apex . Therefore, to neutralize an ocular deviation, the prism must be oriented so that light is redirected precisely onto the displaced fovea: Universal Rule: Apex points in the direction of the deviation; Base points OPPOSITE the deviation. \mathbf{\text{Universal Rule:}} \quad \text{Apex points in the direction of the deviation; Base points OPPOSITE the deviation.} Universal Rule: Apex points in the direction of the deviation; Base points OPPOSITE the deviation.

Prismatic Orientation Matrix

  • Deviation Type Direction Globe Has Turned Required Prism Base Orientation Optical Ray Deflection
  • Esotropia / Esophoria (ET / E) Inward (Nasal) Base-Out (BO) Base temporal; bends light toward nasal fovea
  • Exotropia / Exophoria (XT / X) Outward (Temporal) Base-In (BI) Base nasal; bends light toward temporal fovea

Right Hypertropia (RHT) OD turned Upward Base-Down (BD) over OD (or BU OS) Bends light downward onto superior fovea

Right Hypotropia (R-HypoT) OD turned Downward Base-Up (BU) over OD (or BD OS) Bends light upward onto inferior fovea Prism Base Orientation Rule:

  • [Base-OUT] [Base-IN]
  • <-- B A --> <-- A B -->
  • Apex points IN Apex points OUT
  • (Neutralizes ESOTROPIA) (Neutralizes EXOTROPIA)
  • Prismatic Placement Artifacts: Frontal Plane vs. Prentice Position

Plastic Prism Bars: Calibrated for use in the frontal plane position (anterior surface of the prism parallel to the patient's face). Tilting a plastic prism bar creates severe optical power errors.

Glass Prisms: Calibrated in the Prentice position (posterior surface perpendicular to the visual axis / line of sight).

Prism Splitting: In large deviations (>20 Δ \Delta Δ ), placing total prism power over one eye introduces distortion and asymmetric chromatic dispersion. Prisms should be split equally between both eyes (e.g., a 40 Δ \Delta Δ ET is split into 20 Δ \Delta Δ BO OD and 20 Δ \Delta Δ BO OS ).

Tangent Screen Dissociation: Lancaster Red-Green & Hess Screen

The Lancaster Red-Green Test and the Hess Screen are sophisticated diagnostic tangent screen evaluations designed to plot ocular motility, diagnose paretic vs. restrictive strabismus, and quantify cyclotropia across nine diagnostic fields of gaze.

1. The Lancaster Red-Green Test: Setup and Physics

Optical Dissociation: The patient wears red-green goggles (by standard convention, the Red filter is placed over the Right Eye [OD] , and the Green filter is placed over the Left Eye [OS] ).

Screen: A white or gray tangent screen calibrated in 1° squares (or 2 Δ \Delta Δ per centimeter grid) at a distance of 1.0 meter or 2.0 meters .

Projectors:

The examiner holds a flashlight projecting a red streak .

The patient holds a flashlight projecting a green streak .

Optical Filter Property: An eye covered with a red filter can only see the red light; an eye covered with a green filter can only see the green light. Thus, the two eyes are 100% dissociated.

2. Examination Protocol

The examiner projects the red streak onto the central fixation target on the screen (the right eye, viewing through the red filter, fixates this streak).

The patient is instructed to project the green streak and overlap it perfectly with the red streak.

The patient's left eye (viewing through green) shifts to place the green streak onto its fovea. If the left eye is misaligned, the green streak will be separated from the red streak on the screen.

The examiner repeats this projection in all nine diagnostic positions of gaze .

Reversal of Filters: The red-green goggles are then reversed (Red over OS, Green over OD) and the test is repeated, allowing fixation to be tested with the contralateral eye.

3. Chart Interpretation Rules: Underactions vs. Overactions

When viewing the completed Lancaster or Hess chart, the technologist applies three strict neuro-ophthalmic rules:

The Smaller (Contracted) Field Represents the Paretic Eye: The eye with the underacting muscle cannot move fully into its field of action; therefore, its projected field on the chart is compressed and smaller than normal.

The Larger (Expanded) Field Represents the Contralateral Normal Eye: When the paretic eye fixates, Hering's Law demands excessive innervation to hold fixation, driving the contralateral yoke muscle into massive overaction. This produces an abnormally large, expanded plot for the non-paretic eye.

Torsional Deviations (Cyclotropia): Because the Lancaster test projects linear slits (streaks) of light rather than round dots, the patient can rotate their streak until it appears parallel to the examiner's streak. If the patient must tilt their green streak to make it appear straight, cyclotropia is directly measured in degrees.

  • Comparison: Lancaster Red-Green vs. Hess Screen
  • | Feature | Lancaster Red-Green Test | Hess Screen Test |
  • | :--- | :--- | :--- | |
  • | Target Geometry | Linear streaks (allows torsion measurement) | Circular dots or intersection points |
  • | Working Distance | Typically 1.0 m or 2.0 m | Typically 0.5 m (50 cm) screen |

| Testing Coordinates | Measures deviation in Prism Diopters / degrees | Measures deviation directly in degrees |

| Primary Utility | In-depth cyclodeviation & incomitance | Rapid mapping of neurogenic paresis |