1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements

1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification

2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology

2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway

3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety

3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety

4 Chapter 4: Ophthalmic History Taking & Clinical Documentation

4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record

5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction

6 Chapter 6: Tonometry, Keratometry & Pupil Measurement

6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria

7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis

7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment

8 Chapter 8: Refraction, Retinoscopy & Refinement

8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations

9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics

9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations

10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy

10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training

11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation

11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing

12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique

12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics

13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols

13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials

14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)

14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics

15 Chapter 15: Fluorescein Angiography Principles & Technique

15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management

16 Chapter 16: Angiographic Interpretation & Pathology

16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology

17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography

17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers

18 Chapter 18: Ophthalmic Photography & Videography

18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management

19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)

19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging

20 Chapter 20: Biometry, Topography & Corneal Analysis

20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth

21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting

21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems

22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications

22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis

23 Chapter 23: Ocular Pharmacology

23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF

24 Chapter 24: Microbiology & Ocular Specimen Collection

24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection

25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery

25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs

26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery

26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol

27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures

27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)

28 Chapter 28: Ophthalmic Patient Services & Education

28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support

29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance

29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements

12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test

Key Takeaways Explain This Topic AI

Congenital colour deficiency is usually red-green, X-linked recessive, affecting about 8% of males and 0.5% of females.

Acquired blue-yellow defects suggest retinal disease and acquired red-green defects suggest optic nerve disease — Köllner's rule.

Ishihara plates screen for congenital red-green deficiency and do not detect blue-yellow loss.

The Farnsworth D-15 separates mild from clinically significant defects and classifies the axis of confusion.

The Farnsworth-Munsell 100-Hue test is the most sensitive clinical test and produces a quantitative error score.

Last updated: September 2026

Physiology and classification

Normal human colour vision is trichromatic , based on three cone photopigments: S (short, blue-sensitive, peak about 420 nm) , M (medium, green, about 530 nm) and L (long, red, about 560 nm) .

Category Description Terminology

Anomalous trichromacy All three pigments present but one is shifted Protanomaly (L shifted), deuteranomaly (M shifted), tritanomaly (S shifted)

Dichromacy One pigment entirely absent Protanopia (no L), deuteranopia (no M), tritanopia (no S)

Monochromacy No colour discrimination Rod monochromacy (achromatopsia) — also nystagmus, photophobia and poor acuity

Congenital colour deficiency is overwhelmingly red-green (protan and deutan), X-linked recessive , present in about 8% of males and 0.5% of females . It is stable, bilateral, symmetrical and present from birth, and the patient is often unaware. Deuteranomaly is the most common single type.

Acquired colour deficiency is a different animal: it is often unilateral or asymmetrical , progressive or fluctuating , accompanied by other visual symptoms, and the patient notices it.

Köllner's rule is the interpretive key:

Outer retinal disease (macular degeneration, central serous chorioretinopathy, diabetic maculopathy) → blue-yellow (tritan) defects.

Optic nerve disease (optic neuritis, compressive optic neuropathy, toxic optic neuropathy) → red-green defects.

The rule has exceptions — glaucoma produces blue-yellow loss despite being an optic neuropathy, and some hereditary maculopathies produce red-green loss — but it is the framework the examination expects.

Drug and toxin causes worth knowing: ethambutol (red-green, dose-related, reversible if caught early), digoxin (yellow-green vision, xanthopsia), hydroxychloroquine, sildenafil-class drugs (transient blue tinge), and methanol.

Pseudoisochromatic plates

Ishihara plates are the standard screening test. Each plate presents a figure of coloured dots against a background of dots that differ in hue but match in brightness and saturation , so the figure can only be seen by hue discrimination.

Plate types: demonstration (seen by everyone, including malingerers), transformation (normal and deficient see different numbers), vanishing (normal sees a number, deficient sees none), hidden digit (deficient sees a number, normal sees none) and classification plates (separate protan from deutan).

Technique, and the errors that invalidate it:

Use natural daylight or a calibrated daylight illuminant — approximately 6500 K. Incandescent light shifts the spectrum and produces false results. This is the most common technique error.

Test one eye at a time — essential for detecting acquired unilateral defects, and routinely skipped.

Hold the book at about 75 cm , plates perpendicular to the line of sight .

Allow about 3 seconds per plate ; delayed or hesitant responses are recorded.

Patient wears their near correction .

Record as plates read correctly over plates presented , for example "12/14 OD, 6/14 OS."

Limitations: Ishihara detects red-green deficiency only. It will not detect a tritan defect and therefore cannot be used to screen for acquired retinal disease. Other plate sets include Hardy-Rand-Rittler (HRR) , which does test blue-yellow and grades severity, and the Standard Pseudoisochromatic Plates (SPP-2) , designed for acquired defects.

Farnsworth D-15

The Farnsworth Panel D-15 is an arrangement test: 15 coloured caps plus a fixed reference cap, which the patient arranges in order of nearest colour resemblance in a tray.

Purpose. It separates mild (pass) from moderate to severe (fail) defects and classifies the axis of the defect. It is not a screening test for mild anomalous trichromacy — many anomalous trichromats pass — which is exactly its value: a failed D-15 means a defect large enough to affect colour-dependent occupations.

Technique: daylight illumination, caps handled by their rims to avoid soiling, one eye at a time, no time pressure but typically a 2-minute guide, and the cap order recorded from the numbers on the underside.

Scoring. The cap order is plotted on a circular diagram and the sequence is joined with lines.

  • Plot appearance Interpretation
  • Caps in order, a smooth circle Pass
  • Crossings running parallel to the protan axis Protan defect
  • Crossings parallel to the deutan axis Deutan defect
  • Crossings parallel to the tritan axis Tritan defect — suspect acquired retinal disease
  • Scattered, non-axial crossings Severe or irregular defect, poor cooperation, or significant acuity loss

A desaturated D-15 (Lanthony) uses paler caps and is more sensitive, catching milder acquired defects that the standard panel misses.

Farnsworth-Munsell 100-Hue

The FM 100-Hue is the most sensitive clinical colour test. Despite the name it uses 85 caps in four trays, each tray covering a portion of the hue circle, which the patient arranges in order between fixed end caps.

Scoring. Each cap receives an error score based on how far its neighbours differ from the correct sequence; the scores are plotted on a polar diagram and summed as a total error score (TES) .

  • Total error score Interpretation
  • 0–20 Superior discrimination
  • 20–100 Average
  • Over 100 Low discrimination

The shape of the polar plot identifies the axis: a bipolar cluster of errors along the protan, deutan or tritan meridian. Scores worsen naturally with age and with reduced acuity, so results must be interpreted against age-matched norms.

Practical drawbacks: it takes 15 to 30 minutes per eye, demands sustained concentration, and is fatiguing. It is reserved for quantifying and monitoring a known defect — serial testing in a patient on ethambutol or hydroxychloroquine , or tracking recovery in optic neuritis — rather than for screening.

Choosing the right test

  • Question Test
  • Does this child have a congenital red-green deficiency? Ishihara

Is this patient safe for a colour-critical occupation? D-15, plus occupational-specific standards such as lantern tests

Does this patient have an acquired blue-yellow defect suggesting retinal disease? HRR, desaturated D-15, or FM 100-Hue — not Ishihara

How severe is a known defect, and is it progressing? FM 100-Hue with serial total error scores

Is there red desaturation in one eye suggesting optic neuropathy? Bedside red cap comparison between the two eyes, then formal testing

The bedside red cap test deserves its own mention: hold a red object, ask the patient to compare its redness between the two eyes, and ask what percentage of the good eye's red the affected eye sees. A report of "70% as red" is a sensitive early sign of optic nerve dysfunction and takes ten seconds.