Study guide
12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity
IJCAHPO Certified Ophthalmic Medical Technologist COMT
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements
1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification
2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology
2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway
3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety
3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety
4 Chapter 4: Ophthalmic History Taking & Clinical Documentation
4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record
5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision
5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction
6 Chapter 6: Tonometry, Keratometry & Pupil Measurement
6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria
7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis
7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment
8 Chapter 8: Refraction, Retinoscopy & Refinement
8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations
9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics
9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations
10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy
10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training
11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation
11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing
12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique
12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics
13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols
13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials
14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)
14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics
15 Chapter 15: Fluorescein Angiography Principles & Technique
15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management
16 Chapter 16: Angiographic Interpretation & Pathology
16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology
17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography
17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers
18 Chapter 18: Ophthalmic Photography & Videography
18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management
19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)
19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging
20 Chapter 20: Biometry, Topography & Corneal Analysis
20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth
21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting
21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems
22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications
22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis
23 Chapter 23: Ocular Pharmacology
23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF
24 Chapter 24: Microbiology & Ocular Specimen Collection
24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection
25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery
25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs
26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery
26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol
27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures
27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)
28 Chapter 28: Ophthalmic Patient Services & Education
28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support
29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance
29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements
12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity
Key Takeaways Explain This Topic AI
Schirmer I without anaesthetic measures reflex plus basal tearing; with anaesthetic it approximates basal secretion.
Less than 10 mm of wetting in 5 minutes is generally abnormal and less than 5 mm indicates severe aqueous deficiency.
Tear break-up time under 10 seconds indicates an unstable tear film and under 5 seconds is clearly abnormal.
Lissamine green and rose bengal stain devitalised cells and mucin-deficient areas; fluorescein stains epithelial defects.
The Cochet-Bonnet aesthesiometer quantifies corneal sensation by the length of an extended nylon filament.
Last updated: September 2026
Order of testing matters
Tear tests interfere with one another. Perform them least invasive first :
- History and symptom questionnaire
- Osmolarity (if available) — must precede any drop
- Tear meniscus height at the slit lamp
- Tear break-up time (requires fluorescein)
- Corneal and conjunctival staining (fluorescein, then lissamine green)
- Schirmer test
- Corneal sensitivity
Performing a Schirmer first stimulates reflex tearing and corrupts everything after it. Instilling anaesthetic first invalidates the Schirmer I and corneal sensitivity.
Schirmer tests
A standardised 5 mm × 35 mm strip of Whatman No. 41 filter paper is folded at the notch and hooked over the lower lid at the junction of the lateral and middle thirds , away from the cornea. The patient closes the eyes gently (or looks up, per protocol) for 5 minutes , and the wetted length is read from the fold.
- Test Anaesthetic What it measures
- Schirmer I No Basal plus reflex secretion
- Basal secretion test (Jones) Yes — topical anaesthetic, then blot the fornix Approximately basal secretion
Schirmer II Yes, plus nasal mucosa stimulation with a cotton swab Reflex secretion from the nasolacrimal reflex arc
Interpretation (Schirmer I, 5 minutes):
- Wetting Interpretation
- Over 15 mm Normal
- 10–15 mm Borderline
- Under 10 mm Abnormal, consistent with aqueous deficiency
- Under 5 mm Severe aqueous deficiency; consider Sjögren syndrome
Sources of error: the strip touching the cornea (reflex tearing, falsely high), a strip placed centrally rather than laterally, a patient who keeps their eyes open under a fan or bright light (evaporation, falsely low), squeezing, and inconsistent timing. Record which variant was performed — a Schirmer result without its anaesthetic status is uninterpretable.
Tear break-up time
Tear break-up time (TBUT) measures tear film stability , which is the dominant problem in evaporative dry eye — the commonest form.
Instil a minimal amount of fluorescein: moisten a strip with non-preserved saline , shake off excess, touch the inferior fornix. Too much fluorescein artificially lengthens the measured time.
Ask the patient to blink several times, then hold the eyes open without blinking .
View with the cobalt blue filter and a broad beam at low magnification.
Start timing at the last complete blink; stop at the first dark spot, streak or dry area in the tear film.
Repeat three times and average.
- TBUT Interpretation
- Over 10 seconds Normal
- 5–10 seconds Borderline / marginal instability
- Under 5 seconds Clearly abnormal
Non-invasive break-up time (NIBUT) , measured by watching a projected grid or placido ring pattern distort, avoids the confounding effect of the dye and is increasingly standard on modern topographers and surface analysers.
A recurring break-up spot in the same location points to a local surface abnormality — a scar, a Salzmann nodule, an epithelial basement membrane irregularity or a raised suture.
Vital dyes
Three dyes, three different meanings. Confusing them is a standard examination trap.
Dye Stains Viewed with Notes
Sodium fluorescein Epithelial defects — areas where cells are missing and the dye pools in the intercellular spaces or on bare stroma Cobalt blue filter, enhanced by a Wratten yellow #12 barrier filter Does not stain intact epithelium; the standard dye for abrasions, ulcers, dendrites and the Seidel test
Rose bengal Devitalised and dead cells , and epithelium unprotected by mucin White or red-free light Stings considerably ; largely displaced by lissamine green
Lissamine green Same targets as rose bengal — devitalised cells and mucin-deficient areas White or red-free light; best viewed 1 to 4 minutes after instillation Well tolerated , the modern standard for conjunctival staining
Staining patterns worth recognising:
- Pattern Suggests
- Inferior interpalpebral punctate staining Aqueous-deficient dry eye, exposure
Interpalpebral band (3 and 9 o'clock) conjunctival staining Evaporative dry eye, exposure, rigid lens 3-and-9 staining
Superior punctate staining Superior limbic keratoconjunctivitis, foreign body under the upper lid — evert the lid
- Linear vertical abrasions Foreign body under the upper lid
- Dendrite with terminal end bulbs Herpes simplex epithelial keratitis
Positive Seidel — a stream of diluted green fluorescein from a wound under cobalt blue Aqueous leak; full-thickness wound — surgical emergency
The Seidel test is a named technique worth spelling out: apply concentrated fluorescein over the suspect site, view under cobalt blue, and watch for a dark rivulet of aqueous diluting the dye as it flows. A positive Seidel means an open wound.
Corneal sensitivity
Corneal sensation is carried by the long ciliary nerves from the ophthalmic division of the trigeminal nerve (V1) . Testing it is a COMT-level Supplemental Testing task.
Qualitative bedside test. Twist a wisp of cotton wool to a fine point and touch the cornea from the side , out of the patient's line of sight so the response is not anticipatory. Compare the two eyes and compare central with peripheral cornea. Record as normal, reduced or absent, and compare sides. Anaesthetic must not have been instilled.
Quantitative test — the Cochet-Bonnet aesthesiometer. A nylon monofilament of fixed diameter is extended from a holder. A longer filament bends more easily and therefore applies less pressure; a shorter filament is stiffer and applies more pressure.
Start at the full 60 mm length.
Touch the cornea perpendicularly until the filament just begins to bend.
If there is no response, shorten in 5 mm steps and repeat.
Record the longest filament length that produces a consistent response.
A normal cornea responds at or near 60 mm . Progressively shorter thresholds indicate progressively reduced sensation.
Causes of reduced corneal sensation:
Herpes simplex and herpes zoster keratitis — a key diagnostic clue, and the reason a herpetic ulcer may be surprisingly painless
- Diabetes mellitus
- Long-term contact lens wear
- After LASIK, PRK or penetrating keratoplasty (corneal nerves are transected)
- Trigeminal nerve lesions, acoustic neuroma, brainstem disease
- Chronic topical anaesthetic abuse
- Chemical injury
Why it matters clinically: a cornea without sensation loses its protective blink and its trophic nerve supply, producing neurotrophic keratopathy — persistent epithelial defects that do not hurt and can progress to melting and perforation before the patient complains. Reduced sensation therefore changes both the diagnosis and the follow-up interval.