Study guide

6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection

IJCAHPO Certified Ophthalmic Medical Technologist COMT

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements

1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification

2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology

2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway

3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety

3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety

4 Chapter 4: Ophthalmic History Taking & Clinical Documentation

4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record

5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction

6 Chapter 6: Tonometry, Keratometry & Pupil Measurement

6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria

7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis

7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment

8 Chapter 8: Refraction, Retinoscopy & Refinement

8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations

9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics

9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations

10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy

10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training

11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation

11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing

12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique

12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics

13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols

13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials

14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)

14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics

15 Chapter 15: Fluorescein Angiography Principles & Technique

15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management

16 Chapter 16: Angiographic Interpretation & Pathology

16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology

17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography

17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers

18 Chapter 18: Ophthalmic Photography & Videography

18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management

19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)

19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging

20 Chapter 20: Biometry, Topography & Corneal Analysis

20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth

21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting

21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems

22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications

22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis

23 Chapter 23: Ocular Pharmacology

23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF

24 Chapter 24: Microbiology & Ocular Specimen Collection

24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection

25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery

25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs

26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery

26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol

27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures

27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)

28 Chapter 28: Ophthalmic Patient Services & Education

28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support

29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance

29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements

6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection

Key Takeaways Explain This Topic AI

The Perkins tonometer is a hand-held Goldmann-type applanator usable supine, in theatre and in children.

The Tono-Pen uses a Mackay-Marg style transducer and gives a mean with a confidence percentage, performing better on irregular corneas.

Non-contact tonometry needs no anaesthetic but is less accurate at higher pressures and produces aerosol.

Rebound tonometry requires no anaesthetic and uses a single-use disposable probe, making it well suited to children.

Intraocular pressure varies diurnally by 3 to 6 mmHg in normal eyes and more in glaucoma, so the time of measurement must be recorded.

Last updated: September 2026

Hand-held applanation: Perkins

The Perkins tonometer is a hand-held, counterbalanced Goldmann-type applanator with its own cobalt blue illumination. It uses the same 3.06 mm prism and the same mire endpoint, so the technique transfers directly.

Indications: supine patients, bedside and theatre measurement, wheelchair users who cannot reach a slit lamp, children, and patients whose head position prevents slit lamp use. It requires anaesthetic and fluorescein exactly as Goldmann does.

Limitations: more operator-dependent because there is no chin rest stabilising the head, and it requires a free hand to hold the lids.

Tono-Pen and Mackay-Marg style devices

The Tono-Pen uses a small central plunger surrounded by an annular footplate. The footplate absorbs the force of corneal rigidity, so the central transducer registers something close to true intraocular pressure. The instrument samples multiple readings and reports a mean with a statistical confidence indicator (for example 5% coefficient of variation).

Advantages: portable, usable in any position, requires only a small area of cornea so it works on irregular, scarred or oedematous corneas where Goldmann mires are unreadable, and it can be used peripherally or even through a bandage contact lens in some circumstances.

Limitations: requires anaesthetic, requires a single-use latex-free cover (Ocu-Film tip cover) that must be changed between patients, tends to over-read at low pressures and under-read at high pressures relative to Goldmann, and readings drift if the tip cover is wrinkled or the instrument is not calibrated per the manufacturer's schedule.

Non-contact (air puff) tonometry

A calibrated pulse of air flattens the cornea while an optical system detects the moment of applanation; the time or force required is converted to pressure.

Advantages: no anaesthetic , no corneal contact so no direct cross-infection risk from an instrument tip, easy to delegate, useful for screening and for patients with anaesthetic allergy.

Limitations: less accurate than Goldmann, especially above about 20 to 25 mmHg ; strongly affected by central corneal thickness; requires patient cooperation with a startling stimulus; readings vary with tear film and with the moment in the ocular pulse cycle, so the instrument's averaged multiple readings should be used; and it generates aerosol and tear film droplets , which is an infection control consideration for adenoviral conjunctivitis and respiratory pathogens.

Rebound tonometry

A small magnetised probe is propelled at the cornea and its deceleration on rebound is analysed. No anaesthetic is required and the probe is single-use disposable , which eliminates reprocessing.

Advantages: excellent for children and for uncooperative or needle-phobic patients, rapid, home-monitoring versions exist.

Limitations: affected by corneal thickness, requires perpendicular alignment at the corneal apex, and probes are consumable.

Choosing a method

  • Situation Preferred method
  • Routine adult clinic, glaucoma follow-up Goldmann applanation — the reference standard
  • Supine patient, theatre, bedside Perkins
  • Scarred, oedematous or irregular cornea Tono-Pen
  • Child who will not sit at a slit lamp Rebound or Tono-Pen
  • Anaesthetic allergy Non-contact or rebound
  • Suspected epithelial defect or active infectious keratitis Non-contact, or defer
  • Screening a large population Non-contact

When the method changes between visits, the change must be recorded, because readings are not interchangeable between instruments and an apparent pressure rise may be nothing more than a different device.

Diurnal variation and recording

Intraocular pressure is not a fixed number. Normal eyes vary by about 3 to 6 mmHg across the day, typically peaking in the early morning, and glaucomatous eyes commonly vary more. A single measurement therefore tells you the pressure at that moment only.

Practical consequences: always record the time , try to measure a glaucoma patient at a consistent time when trending, and where the clinical picture does not match the numbers, a diurnal curve with several measurements across a day may be requested. Note also that pressure falls transiently after exercise and rises with a Valsalva, a tight collar, breath-holding and, in some patients, with lying supine.

Cleaning and disinfecting tonometers

The blueprint names cleaning and disinfecting tonometers as a task at every certification level. The governing principles:

Clean before disinfect. Organic debris shields organisms; wipe the tip free of tears, mucus and fluorescein first.

Follow the manufacturer's validated instructions for that specific device. Disinfectants that are safe for a Goldmann prism may damage a Tono-Pen or a pachymeter probe.

Common validated approaches for Goldmann prisms include soaking in dilute sodium hypochlorite or 3% hydrogen peroxide for the specified contact time, followed by thorough rinsing with water and drying . Residual disinfectant on a prism causes a chemical keratitis.

Alcohol wipes alone are inadequate against adenovirus unless the manufacturer specifies a validated contact time; alcohol also degrades prism adhesive over time.

Inspect for damage. Chipped or cracked prisms harbour organisms and can abrade the cornea. Remove them from service.

Single-use disposables — disposable prisms, Tono-Pen tip covers and rebound probes — remove the reprocessing failure mode entirely and are preferred where transmissible spongiform encephalopathy or epidemic keratoconjunctivitis is a concern.

Hand hygiene before and after every patient contact, and gloves where there is discharge.

A practical clinic rule: if a patient has a red, discharging eye, use a disposable-tip method and clean the slit lamp chin rest and headrest afterwards.