Study guide
5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio
IJCAHPO Certified Ophthalmic Medical Technologist COMT
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements
1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification
2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology
2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway
3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety
3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety
4 Chapter 4: Ophthalmic History Taking & Clinical Documentation
4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record
5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision
5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction
6 Chapter 6: Tonometry, Keratometry & Pupil Measurement
6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria
7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis
7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment
8 Chapter 8: Refraction, Retinoscopy & Refinement
8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations
9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics
9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations
10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy
10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training
11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation
11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing
12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique
12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics
13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols
13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials
14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)
14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics
15 Chapter 15: Fluorescein Angiography Principles & Technique
15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management
16 Chapter 16: Angiographic Interpretation & Pathology
16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology
17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography
17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers
18 Chapter 18: Ophthalmic Photography & Videography
18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management
19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)
19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging
20 Chapter 20: Biometry, Topography & Corneal Analysis
20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth
21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting
21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems
22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications
22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis
23 Chapter 23: Ocular Pharmacology
23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF
24 Chapter 24: Microbiology & Ocular Specimen Collection
24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection
25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery
25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs
26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery
26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol
27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures
27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)
28 Chapter 28: Ophthalmic Patient Services & Education
28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support
29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance
29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements
5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio
Key Takeaways Explain This Topic AI
Stereoacuity is measured in seconds of arc; 40 seconds of arc at 40 cm is the usual normal on the Titmus test.
Near point of accommodation in dioptres equals 100 divided by the near point in centimetres.
Donders' table gives roughly 14 D of accommodative amplitude at age 10, falling to about 1 D by age 60.
Near point of convergence is normally within about 10 cm; a receded near point suggests convergence insufficiency.
The gradient AC/A ratio is the change in deviation in prism dioptres divided by the dioptric power of the lens used.
Last updated: September 2026
Stereoacuity
Stereopsis is binocular depth perception derived from horizontal retinal disparity. It is measured in seconds of arc — and smaller numbers mean better stereopsis.
Test Type Range Notes
Titmus (Wirt) fly and circles Contour, polarised 3000 to 40 arcsec The fly is gross stereopsis (~3000 arcsec); the nine circles run 800 to 40 arcsec. Monocular cues exist, so a patient may "pass" the fly monocularly
- Randot Contour + random dot 500 to 20 arcsec Random-dot portion removes monocular cues
- TNO Random dot, red-green 480 to 15 arcsec No monocular cues at all
- Lang Random dot, no glasses 1200 to 550 arcsec Useful in infants who will not wear glasses
- Frisby Real depth plates 600 to 15 arcsec No glasses needed
Technique: test at 40 cm with the patient's habitual near correction plus the polarised or red-green glasses, hold the plate parallel to the face (tilting introduces monocular cues), and turn the booklet 180 degrees intermittently to confirm the patient is genuinely seeing depth rather than guessing.
Interpretation. Normal is about 40 seconds of arc or better . Reduced stereoacuity suggests amblyopia, a constant strabismus or unequal image quality. A manifest constant strabismus abolishes fine stereopsis , so a patient claiming a large monocular acuity loss but demonstrating 40 arcsec stereopsis is internally inconsistent.
Near point of accommodation and amplitude
Amplitude of accommodation is the total dioptric change the eye can make from far point to near point.
Push-up method. With the distance correction in place, occlude one eye, bring a near target (a single line of small print or an accommodative target) slowly toward the eye and record the distance at which it first blurs sustainably . Convert:
Amplitude (dioptres) = 100 ÷ near point (centimetres)
A near point of 10 cm gives 10.00 D; 25 cm gives 4.00 D; 50 cm gives 2.00 D.
Minus lens method. With the target fixed at 40 cm, add minus power in −0.25 D steps until sustained blur, then add +2.50 D to account for the 40 cm working distance. Minus-lens amplitudes usually run about 2 D lower than push-up values because push-up gains apparent amplitude from the target's increasing angular size.
Expected values (Donders/Duane).
- Age Approximate amplitude
- 10 14.0 D
- 20 11.0 D
- 30 9.0 D
- 40 6.0 D
- 45 4.0 D
- 50 2.5 D
- 60 1.0 D
Hofstetter's formulas approximate the same: minimum amplitude = 15 − 0.25 × age; average = 18.5 − 0.30 × age; maximum = 25 − 0.40 × age. Accommodative amplitude below the age-expected minimum, with normal refraction, suggests accommodative insufficiency.
Near point of convergence
Near point of convergence (NPC) is the closest point at which the eyes can maintain binocular single vision on a target moved slowly toward the nose.
Technique: binocular, with habitual correction, bring an accommodative target toward the bridge of the nose along the midline. Record two values:
Break — the distance at which the patient reports diplopia or you observe one eye drift out.
Recovery — the distance at which fusion is regained as the target is moved back out.
Normal: break within about 10 cm (many references use 6 to 10 cm) with recovery within about 15 cm . Record as "NPC 8/12 cm." Repeat the measurement several times — convergence insufficiency characteristically fatigues , so the fifth repetition is often markedly worse than the first, and that deterioration is itself the diagnostic finding.
A receded NPC with exophoria greater at near than distance, reduced positive fusional vergence and asthenopia on reading is the classic convergence insufficiency pattern.
The AC/A ratio
The accommodative convergence to accommodation (AC/A) ratio expresses how many prism dioptres of convergence accompany each dioptre of accommodation. Normal is roughly 3:1 to 5:1 . It is the measurement that explains why some esotropias are larger at near and some exotropias larger at distance, and it drives bifocal prescribing in accommodative esotropia.
Gradient method (the more commonly examined). Measure the deviation at a fixed distance, normally 33 cm, then repeat with the same lens power over both eyes and divide the change in deviation by the magnitude of the lens power:
AC/A = |deviation with lens − deviation without lens| ÷ |lens power in dioptres|
Use either a minus lens, which stimulates accommodation and therefore drives an esodeviation larger, or a plus lens, which relaxes accommodation and drives an esodeviation smaller. Either direction yields the same ratio.
Worked example with a minus lens. A child measures 8 prism dioptres of esophoria at 33 cm. With −3.00 D over both eyes the esophoria rises to 26 prism dioptres. AC/A = (26 − 8) ÷ 3 = 6:1 — a high AC/A, the finding that supports a bifocal add in high-AC/A accommodative esotropia.
Worked example with a plus lens. A child measures 10 prism dioptres of esotropia at 33 cm. With +3.00 D over both eyes the deviation falls to 1 prism dioptre. AC/A = (10 − 1) ÷ 3 = 3:1 — a normal ratio, so the near deviation is not accommodatively driven and a bifocal add is unlikely to help.
Heterophoria method:
AC/A = interpupillary distance in centimetres + [(near deviation − distance deviation) ÷ dioptric demand at near]
The gradient method is generally preferred because it holds proximal convergence constant.
Clinical patterns.
- Pattern Finding Typical management
- High AC/A Esodeviation much larger at near than distance Bifocal add, sometimes miotics
- Low AC/A Exodeviation larger at near; convergence insufficiency Convergence exercises, base-in prism
- Normal AC/A Deviation similar at distance and near Treat the underlying deviation