Study guide

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients

IJCAHPO Certified Ophthalmic Medical Technologist COMT

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements

1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification

2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology

2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway

3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety

3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety

4 Chapter 4: Ophthalmic History Taking & Clinical Documentation

4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record

5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction

6 Chapter 6: Tonometry, Keratometry & Pupil Measurement

6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria

7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis

7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment

8 Chapter 8: Refraction, Retinoscopy & Refinement

8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations

9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics

9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations

10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy

10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training

11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation

11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing

12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique

12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics

13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols

13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials

14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)

14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics

15 Chapter 15: Fluorescein Angiography Principles & Technique

15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management

16 Chapter 16: Angiographic Interpretation & Pathology

16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology

17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography

17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers

18 Chapter 18: Ophthalmic Photography & Videography

18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management

19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)

19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging

20 Chapter 20: Biometry, Topography & Corneal Analysis

20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth

21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting

21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems

22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications

22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis

23 Chapter 23: Ocular Pharmacology

23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF

24 Chapter 24: Microbiology & Ocular Specimen Collection

24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection

25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery

25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs

26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery

26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol

27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures

27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)

28 Chapter 28: Ophthalmic Patient Services & Education

28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support

29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance

29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients

Key Takeaways Explain This Topic AI

Snellen acuity is a ratio of test distance to the distance at which the letter subtends 5 minutes of arc.

Counting fingers must be recorded with the distance at which fingers were correctly counted.

Light perception is recorded as with or without projection, tested in four quadrants in a darkened room with the fellow eye fully occluded.

Preferential looking (Teller cards) estimates infant acuity in cycles per degree and is converted to a Snellen equivalent.

Pinhole acuity improves with uncorrected refractive error or irregular media and does not improve with macular or optic nerve disease.

Last updated: September 2026

What a Snellen fraction means

Snellen acuity is a ratio : the numerator is the test distance and the denominator is the distance at which the smallest letter read would subtend 5 minutes of arc overall, with each stroke and gap subtending 1 minute of arc . A patient reading 20/40 at 20 feet sees at 20 feet what a standard observer sees at 40 feet.

logMAR notation expresses the same thing as the logarithm of the minimum angle of resolution: 20/20 is logMAR 0.00, 20/40 is 0.30, 20/200 is 1.00. LogMAR charts (ETDRS) have five letters per line with equal log spacing , which makes them the research standard and lets you score letter by letter — each letter is worth 0.02 logMAR.

  • Snellen (ft) Snellen (m) logMAR Decimal
  • 20/20 6/6 0.00 1.00
  • 20/25 6/7.5 0.10 0.80
  • 20/40 6/12 0.30 0.50
  • 20/60 6/18 0.48 0.33
  • 20/100 6/30 0.70 0.20
  • 20/200 6/60 1.00 0.10
  • 20/400 6/120 1.30 0.05
  • Optotypes for different patients

The blueprint names Allen figures, Tumbling E, numbers and Snellen letters . Choose by the patient's ability, not their age.

  • Optotype Best for Notes
  • Snellen letters Literate patients Unequal letter legibility across lines is its main weakness
  • Numbers Patients who read numerals but not the Latin alphabet Useful for many non-English speakers

Tumbling E Illiterate, non-verbal, and many non-English speakers Patient points in the direction of the legs; demonstrate with a handheld E first

  • Landolt C Same indications as Tumbling E International standard; patient indicates the gap
  • HOTV / Lea symbols Children roughly 2.5 to 5 years Matching card avoids the need to name

Allen figures Young children Familiar pictures; tends to overestimate acuity because the figures are recognisable when blurred

Teller / preferential looking cards Infants and non-verbal patients Reported in cycles per degree, convertible to Snellen equivalent

For children, test each eye separately with an adhesive occluder patch , not a hand or a paper occluder they can peep around. Test the worse eye first if known, because attention fades. For preferential looking, a trained observer judges which side of the card the infant fixates while blind to the grating's position.

Low vision acuity sequence

When the largest optotype cannot be read at the standard distance, do not jump straight to counting fingers — first bring the patient closer . A patient who reads the 20/200 line at 5 feet has an acuity of 5/200 , which is far better documentation than "counts fingers."

Then proceed in order:

Counting fingers (CF) — hold up fingers against a plain dark background and record the distance : "CF at 3 ft OD."

Hand motion (HM) — record the distance: "HM at 2 ft OS."

Light perception with projection (LP with projection) — in a darkened room, fellow eye completely occluded, shine a bright light from each of four quadrants and ask the patient to point toward it. Record which quadrants are perceived.

Light perception without projection (LP) — light is seen but cannot be localised.

No light perception (NLP) — confirm meticulously. NLP has major medico-legal and prognostic weight.

Pinhole testing

A pinhole of about 1.2 mm restricts the beam to the central, least-aberrated part of the optical system, increasing depth of focus and neutralising most refractive blur.

Improves with uncorrected refractive error, irregular astigmatism, early cataract or corneal irregularity.

Does not improve, or worsens , with macular disease, optic neuropathy, dense central media opacity or amblyopia.

A multiple pinhole is easier for patients with poor fixation than a single aperture.

Pinhole rarely improves acuity beyond about 20/25 to 20/30 because diffraction begins to limit resolution.

  • Record pinhole whenever unaided or habitual acuity is worse than expected: "20/60 cc, PH 20/25 OD."
  • Special populations in practice

Non-verbal or cognitively impaired adults. Use Tumbling E with pointing, or matching with a handheld card. If no response is obtainable, document fixation behaviour: CSM notation records whether fixation is C entral, S teady and M aintained through a blink with the fellow eye occluded.

Non-English-speaking patients. Numbers or Tumbling E remove the language barrier entirely. Use a professional interpreter for instructions and document that one was used.

Hearing-impaired patients. Face the patient, do not cover your mouth, demonstrate the task rather than explaining it, and use written instructions.

Nystagmus. Test binocularly as well as monocularly and record both, because occlusion often worsens nystagmus and underestimates functional acuity. Use a +5.00 D fogging lens over the fellow eye rather than full occlusion where possible, and allow the patient to adopt their null-point head posture.

Malingering and functional loss. Suspect it when acuity is inconsistent with pupil responses, with the ability to navigate the room, or with the optokinetic response. Testing with progressively less obvious cues, using a fogging lens, or checking stereoacuity (good stereoacuity is incompatible with severe monocular loss) helps sort it out. The technologist documents observations and defers conclusions to the provider.

Near acuity

Near acuity is recorded with the test distance and the notation system used — Jaeger (J1 to J16), point size, reduced Snellen or M units. J notation is not standardised across cards, so the card used should be recorded. Presbyopic patients must wear their near correction, and low vision patients may be tested at a shortened distance with the distance explicitly recorded, for example "1.6 M at 10 cm."