Study guide

11.1 Amsler Grid & Confrontation Visual Field Testing

IJCAHPO Certified Ophthalmic Medical Technologist COMT

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: The COMT Examination, Eligibility & Certification Requirements

1.1 The 190-Question Multiple-Choice Examination & the 22 Official Content Areas 1.2 The COT Skill Evaluation & the COMT Performance Test 1.3 Eligibility Pathways, Fees, Timelines & Recertification

2 Chapter 2: General Medical Knowledge I — Ocular Anatomy & Physiology

2.1 Orbit, Eyelids, Lacrimal System, Conjunctiva & Extraocular Muscles 2.2 Cornea, Sclera, Anterior Chamber, Angle, Aqueous Dynamics & Crystalline Lens 2.3 Uvea, Retina, Vitreous, Optic Nerve, Ocular Circulation & the Visual Pathway

3 Chapter 3: General Medical Knowledge II — Eye Disease, Systemic Manifestations, Terminology & Safety

3.1 Frequently Encountered Eye Conditions by Structure & Inflammation Versus Infection 3.2 Body Systems & the Ocular Manifestations of Systemic Disease 3.3 Medical Terminology, Approved Abbreviations, Hazardous Waste & Clinic Safety

4 Chapter 4: Ophthalmic History Taking & Clinical Documentation

4.1 The Five History Domains: Ocular, Medical, Medication, Social & Family 4.2 Charting Conventions, Scribing & the Electronic Medical Record

5 Chapter 5: Visual Assessment, Accommodative Testing & Low Vision

5.1 Measuring Acuity at Every Level & in Preliterate, Illiterate and Non-Verbal Patients 5.2 Stereoacuity, Near Point of Accommodation, Near Point of Convergence & the AC/A Ratio 5.3 Low Vision Assessment, Magnification Calculation & Device Instruction

6 Chapter 6: Tonometry, Keratometry & Pupil Measurement

6.1 Goldmann Applanation Tonometry: Technique, Sources of Error & the Imbert-Fick Principle 6.2 Hand-Held Applanators, Non-Contact Tonometry, Rebound Tonometry & Disinfection 6.3 Manual & Automated Keratometry: Technique, Readings and Interpretation 6.4 Pupil Measurement, Shape, Reactivity & Evaluating Anisocoria

7 Chapter 7: Lensometry, Spectacle Optics & Prescription Analysis

7.1 Manual Lensometry: Eyepiece Focus, Neutralising Sphere, Cylinder & Axis 7.2 Neutralising Reading Adds: Bifocal, Trifocal, Progressive & Determining the Near Add 7.3 Identifying & Measuring Prism: Ground-In, Decentration, Fresnel Press-On & Slab-Off 7.4 Transposition, Spherical Equivalent, Vertex Distance & Prescription Components 7.5 The Geneva Lens Clock, Lens Materials, Progressive Markings & Spectacle Adjustment

8 Chapter 8: Refraction, Retinoscopy & Refinement

8.1 Autorefraction, Refractive Error Types & Establishing an Objective Starting Point 8.2 Streak Retinoscopy: With Motion, Against Motion, Neutralisation & Working Distance 8.3 Subjective Refinement: Fogging, Jackson Cross Cylinder, Duochrome & Binocular Balance 8.4 Near Add Determination, Vertex Recording & Refraction in Difficult Situations

9 Chapter 9: Ocular Motility, Strabismus & Advanced Optics

9.1 Ocular Kinematics: Ductions, Versions, Vergences, Hering's & Sherrington's Laws 9.2 Quantitative Strabismus Measurements: Alternate Cover Test, Prism Cover Test & Lancaster Red-Green / Hess Screen 9.3 Cranial Nerve Palsies (CN III, IV, VI), Restrictive Myopathies & Forced Duction Testing 9.4 Clinical Optics, Prentice's Rule, Slab-Off Prisms & Wavefront Aberrations

10 Chapter 10: Sensory Fusion Testing, Nystagmus, Amblyopia & Vergence Therapy

10.1 Sensory Fusion Testing: Worth 4-Dot, Maddox Rod & Bagolini Lenses 10.2 Hirschberg, Krimsky, Brückner & Fusional Vergence Amplitudes 10.3 Nystagmus, Amblyopia Therapy & Convergence Training

11 Chapter 11: Advanced Visual Fields & Neuro-Ophthalmic Evaluation

11.1 Amsler Grid & Confrontation Visual Field Testing 11.2 Automated Static Perimetry: HFA Strategies (SITA Standard, SITA Fast), Reliability Indices & Statpac Analysis 11.3 Visual Field Defect Patterns: Glaucomatous Nerve Fiber Bundle Deficits vs. Retinal Pathology 11.4 Kinetic Perimetry (Goldmann Perimetry) & Neurological Visual Pathway Defect Localization 11.5 Pupillary Pathways, RAPD Quantitation with Neutral Density Filters & Pharmacologic Testing

12 Chapter 12: Supplemental Testing — Glare, PAM, Colour Vision, Tear Film & Slit Lamp Technique

12.1 Glare Testing, Potential Acuity Meter & Contrast Sensitivity 12.2 Colour Vision: Pseudoisochromatic Plates, Farnsworth-Munsell D-15 & the 100-Hue Test 12.3 Tear Film Assessment: Schirmer, Tear Break-Up Time, Vital Dyes & Corneal Sensitivity 12.4 Slit Lamp Technique, Slit Lamp Lenses, Direct Ophthalmoscopy & Pen Light Examination 12.5 Exophthalmometry, Head & Posture Assessment and Wavefront Diagnostics

13 Chapter 13: Full-Field Electroretinography & ISCEV Protocols

13.1 Retinal Neurophysiology & Electrophysiologic Origin of Waveforms 13.2 ISCEV Standard Full-Field ERG Protocol & Electrode Systems 13.3 Dark-Adapted (Scotopic) Testing: Rod-Driven Responses & Combined Maximal Response 13.4 Light-Adapted (Photopic) Testing: Cone Response, 30-Hz Flicker & Oscillatory Potentials

14 Chapter 14: Advanced Electrophysiologic Testing (mfERG, PERG, VEP, EOG)

14.1 Multifocal Electroretinogram (mfERG): Topographic Retinal Mapping 14.2 Pattern Electroretinogram (PERG): Ganglion Cell & Macular Function 14.3 Visual Evoked Potentials (VEP): Flash, Pattern & Visual Pathway Integrity 14.4 Electrooculogram (EOG), Arden Ratio & RPE Light Peak Dynamics

15 Chapter 15: Fluorescein Angiography Principles & Technique

15.1 Fluorescein Angiography Principles, Exciter/Barrier Filters & Injection Protocol 15.2 Normal Transit Phases & Retinal/Choroidal Circulation Hemodynamics 15.3 Adverse Reactions, Patient Safety & Emergency Management

16 Chapter 16: Angiographic Interpretation & Pathology

16.1 Hyperfluorescence Mechanisms: Leakage, Staining, Pooling, Window Defects & Autofluorescence 16.2 Hypofluorescence Mechanisms: Vascular Non-Perfusion & Blocking Defects 16.3 Indocyanine Green (ICG) Angiography: Principles, Indications & Choroidal Pathology

17 Chapter 17: Advanced Fundus Imaging & Optical Coherence Tomography

17.1 Fundus Autofluorescence (FAF) & Ultra-Widefield Fundus Imaging 17.2 Spectral-Domain and Swept-Source OCT: Retinal Layer Architecture & Quantitative Analysis 17.3 Enhanced Depth Imaging (EDI-OCT) & Anterior Segment OCT (AS-OCT) 17.4 Optical Coherence Tomography Angiography (OCTA): Chorioretinal Plexuses & Biomarkers

18 Chapter 18: Ophthalmic Photography & Videography

18.1 The Fundus Camera: Optics, Alignment & Correcting Artefacts 18.2 Standard Fundus Photography: ETDRS Fields, Stereo Pairs, Red-Free & Wide-Field Imaging 18.3 Slit Lamp & Anterior Segment Photography 18.4 External Photography, Nine-Gaze Motility Documentation & Image Management

19 Chapter 19: Ophthalmic Echography (A-Scan, B-Scan & UBM)

19.1 Physics of Ophthalmic Ultrasound, Acoustic Impedance & Probe Transducers 19.2 Standardized Diagnostic A-Scan: Acoustic Spikes, Tissue Reflectivity & Attenuation 19.3 Diagnostic B-Scan Echography: Topographic, Kinetic & Quantitative Vitreoretinal Evaluation 19.4 Ultrasound Biomicroscopy (UBM): Anterior Segment Anatomy, Angle Pathology & Ciliary Body Imaging

20 Chapter 20: Biometry, Topography & Corneal Analysis

20.1 Optical Biometry vs. Immersion/Contact Ultrasound Biometry 20.2 Intraocular Lens (IOL) Power Calculation Formulas & Post-Refractive Adjustments 20.3 Corneal Topography, Scheimpflug Tomography & Keratoconus Screening 20.4 Corneal Pachymetry, Endothelial Specular Microscopy & Anterior Chamber Depth

21 Chapter 21: Rigid Gas Permeable & Specialty Lens Fitting

21.1 Rigid Gas Permeable (RGP) Material Properties, Dk/t & Oxygen Permeability 21.2 RGP Base Curve Selection, Diagnostic Fitting & Fluorescein Pattern Evaluation 21.3 Scleral Contact Lens Design, Sagittal Depth Fitting & Clearance Evaluation 21.4 Keratoconus, Irregular Corneas & Hybrid Contact Lens Systems

22 Chapter 22: Toric, Multifocal, Therapeutic Lenses & Complications

22.1 Toric Soft Contact Lens Dynamics, Stabilization Techniques & LARS Rule 22.2 Presbyopic & Multifocal Contact Lens Systems: Simultaneous vs. Translating Designs 22.3 Therapeutic Bandage Contact Lenses, Amniotic Membranes & Orthokeratology 22.4 Contact Lens-Induced Pathology, Giant Papillary Conjunctivitis & Infectious Keratitis

23 Chapter 23: Ocular Pharmacology

23.1 Routes of Drug Delivery, Prescription Components & Instillation Technique 23.2 Mydriatics, Cycloplegics, Anaesthetics & Diagnostic Agents 23.3 Glaucoma Medications: Classes, Mechanisms & Side Effects 23.4 Anti-Infectives, Corticosteroids, NSAIDs, Allergy Agents, Lubricants, Supplements & Anti-VEGF

24 Chapter 24: Microbiology & Ocular Specimen Collection

24.1 Types of Microorganisms & Pathways of Disease Transmission 24.2 Assisting with Conjunctival & Corneal Specimen Collection

25 Chapter 25: Anterior Segment, Glaucoma & Refractive Surgery

25.1 Advanced Phacoemulsification, Surgical Steps, Fluidics & Complication Management 25.2 Premium Intraocular Lenses: Toric, Multifocal, EDOF & Lens Exchange 25.3 Glaucoma Surgical Procedures: Trabeculectomy, Aqueous Shunts & MIGS Devices 25.4 Laser In Situ Keratomileusis (LASIK), PRK, SMILE & Phakic IOLs

26 Chapter 26: Vitreoretinal, Corneal & Trauma Surgery

26.1 Pars Plana Vitrectomy (PPV), Scleral Buckling & Intraocular Tamponades (Gas/Silicone Oil) 26.2 Corneal Transplantation: Penetrating Keratoplasty (PKP) & Lamellar Keratoplasty (DSAEK, DMEK, DALK) 26.3 Ocular Trauma Repair: Open Globe Management, Hyphema, Vitreous Loss & Endophthalmitis Protocol

27 Chapter 27: Surgical Asepsis, Instrumentation & Laser Procedures

27.1 Operating Room Sterilization, Aseptic Field Maintenance & Universal Precautions 27.2 Microsurgical Instrumentation, Maintenance & Sharps Safety 27.3 Ophthalmic Laser Physics, Delivery Systems & Safety (Nd:YAG, Argon/FD-Nd:YAG, SLT)

28 Chapter 28: Ophthalmic Patient Services & Education

28.1 Communicating with Patients, Families and Colleagues, and Handling Dissatisfaction 28.2 Patient Education & Counselling on Conditions, Medications, Tests and Results 28.3 Ophthalmic Emergencies, First Aid, Vital Signs & CPR 28.4 Triage, Urgency-Based Scheduling, Patient Flow & Telephone Management 28.5 Dressings and Shields, Prosthetics, Legal Forms, Referrals & Reimbursement Support

29 Chapter 29: Clinic Operations — Equipment Maintenance, Ethics, Coding & Compliance

29.1 Equipment Maintenance, Calibration, Emergency Equipment & Inventory 29.2 Confidentiality, Informed Consent, Scope of Practice & Ethical Standards 29.3 Coding, Scribing Compliance, Quality Assurance & Regulatory Requirements

11.1 Amsler Grid & Confrontation Visual Field Testing

Key Takeaways Explain This Topic AI

The standard Amsler grid is 10 cm square with 5 mm squares, viewed at 30 cm, and tests the central 10 degrees.

The patient must wear their near correction and cover one eye, keeping fixation on the central dot throughout.

Metamorphopsia indicates retinal distortion, while a scotoma indicates an area of non-functioning retina.

Confrontation fields compare the patient's field against the examiner's and reliably detect only gross defects.

A hemianopic defect that respects the vertical midline localises at or behind the chiasm.

Last updated: September 2026

The Amsler grid

The Amsler grid tests the central 10 degrees of the visual field — the macular field — at a level of detail no automated perimeter matches in a ten-second bedside test.

The standard chart is a 10 cm square divided into 5 mm squares with a central fixation dot. Viewed at 30 cm , each small square subtends 1 degree and the whole grid subtends 20 degrees, that is 10 degrees from fixation in every direction.

The seven standard charts:

  • Chart Description Use
  • 1 White grid on black Standard
  • 2 Adds diagonal lines to the centre Central scotoma preventing fixation
  • 3 Red grid on black Red desaturation in optic neuropathy and toxic maculopathy
  • 4 Dots only, no lines Distinguishes scotoma from metamorphopsia
  • 5 Horizontal lines only Detects metamorphopsia in a specific meridian
  • 6 Black on white with fine central lines Fine metamorphopsia near fixation
  • 7 Fine central grid Detailed central 4 degrees

Technique.

Patient wears their near correction — this is the most commonly skipped step and it invalidates the test.

Test one eye at a time , occluding the other completely.

Hold the grid at 30 cm under good, even illumination.

Instruct: "Look at the dot in the centre and keep looking at it." Fixation must not wander.

Ask four questions while fixation is maintained:

Can you see the central dot?

While looking at the dot, can you see all four corners and all four sides?

Are any of the lines wavy, bent or distorted?

Are any areas blurred, missing, dark or faded?

Have the patient mark the abnormality on a copy of the grid, or describe its location and size.

Interpretation.

Finding Meaning Common causes

Metamorphopsia — wavy or bent lines Photoreceptors displaced by fluid or traction Choroidal neovascularisation, central serous chorioretinopathy, epiretinal membrane, macular oedema

  • Central scotoma Non-functioning central retina Geographic atrophy, macular hole, macular scar
  • Paracentral scotoma Focal lesion off fixation Drusen, small haemorrhage

Micropsia / macropsia — squares smaller or larger in one area Photoreceptor spreading or crowding Retinal oedema, resolving serous detachment

Blurred area without distortion Media opacity or a mild defect Cataract, vitreous opacity

Home monitoring is the grid's highest-value use. Patients with dry macular degeneration are given a grid and told to test one eye at a time, daily , and to report new distortion immediately, because conversion to wet macular degeneration is treatable and time-sensitive.

Confrontation visual fields

Confrontation compares the patient's peripheral field against the examiner's, assumed normal. It is quick and requires no equipment, and it detects only gross defects — but a hemianopia found in thirty seconds changes the whole visit.

Setup. Sit directly facing the patient at about 1 metre , at the same eye level. Test one eye at a time : the patient covers their left eye while you close or cover your right, so your fields overlap. The patient fixates your open eye throughout — and you watch for their fixation to wander, which invalidates the result.

Methods, from coarse to fine:

Method How Detects

Finger counting Present 1, 2 or 5 fingers midway between you and the patient in each of four quadrants; the patient states the number Dense quadrantic and hemianopic defects

Finger wiggle Wiggle a finger in each quadrant, asking the patient to point to the moving one Gross field loss; more sensitive than static presentation in some patients

Simultaneous double presentation Present fingers in two quadrants at once (for example both superior quadrants) and ask "left, right or both?" Subtle hemifield loss and visual neglect , which is missed by single presentation

Red target comparison Move a red pin or bottle top between hemifields and ask whether the red looks the same on both sides Red desaturation across the vertical midline in chiasmal disease, and across the horizontal midline in optic nerve disease

Kinetic confrontation Bring a target in from beyond the field edge in each of eight meridians and ask when it first appears A rough field outline

Documenting the result. Draw the finding rather than writing "full to confrontation" by habit. Record which method was used, note whether fixation was maintained, and state the quadrants tested.

Localising patterns

The single most valuable question is whether the defect respects the vertical midline .

  • Pattern Localisation
  • Monocular field loss Anterior to the chiasm — retina or optic nerve

Altitudinal (respects the horizontal midline) Optic nerve head — ischaemic optic neuropathy, or a retinal branch artery occlusion

Bitemporal hemianopia respecting the vertical midline Chiasm — pituitary adenoma, craniopharyngioma, meningioma

  • Homonymous hemianopia Retrochiasmal, contralateral to the lesion
  • Superior homonymous quadrantanopia Temporal lobe, Meyer's loop — "pie in the sky"
  • Inferior homonymous quadrantanopia Parietal lobe — "pie on the floor"
  • Congruous homonymous hemianopia with macular sparing Occipital cortex
  • Generalised constriction Advanced glaucoma, retinitis pigmentosa, panretinal photocoagulation, or non-organic
  • Limitations and when to escalate

Confrontation testing misses most early glaucomatous and toxic field loss. Its sensitivity for mild defects is low, and a normal confrontation field does not exclude a field defect. Any patient with symptoms suggestive of field loss, any abnormal confrontation finding, and any patient under glaucoma or neurological surveillance needs formal automated or kinetic perimetry , which is covered in the automated perimetry and Goldmann sections of this guide.

The practical role of confrontation and Amsler testing is therefore triage and monitoring: fast, repeatable, performable at the bedside or by the patient at home, and capable of catching the large defects that must not wait.