Study guide
7.1 Slides
Certified Playground Safety Inspector CPSI
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Pathways, Scheduling & Fees 1.3 Recertification, Registry & What a CPSI Does
2 Standards Landscape & Injury Epidemiology
2.1 Playground Standards & Guidelines (ASTM and CPSC) 2.2 Why the Standards Exist 2.3 Causes of Injury & Injury Patterns
3 Hazard Ranking & Entanglement
3.1 Identifying, Ranking & Prioritizing Hazards 3.2 Causes of Entanglement Hazards 3.3 Tools to Identify Entanglement Hazards
4 Protrusions & Entrapment Causes
4.1 Causes of Protrusion Hazards 4.2 Tools and Gauges to Identify Protrusions 4.3 Causes of Entrapment Hazards
5 Entrapment Tools & Crush/Shear
5.1 Tools and Probes to Identify Entrapment 5.2 Causes of Crush and Shear Hazards 5.3 Tools and Dowels to Identify Crush/Shear
6 Miscellaneous Hazards, Platforms & Access
6.1 Miscellaneous Hazards 6.2 Platforms, Guardrails & Barriers 6.3 Access, Egress & Handrails
7 Slides, Swings & Climbers
7.1 Slides 7.2 Swings 7.3 Climbers & Upper-Body Equipment
8 Rotating, Rocking & Track Equipment
8.1 Rotating Equipment 8.2 Rocking Equipment, Seesaws & Spring Rockers 8.3 Track Rides, Trolleys & Other Equipment
9 Surfacing Standards & Testing
9.1 Surfacing Standards & Guidelines 9.2 Impact Attenuation, Gmax & HIC 9.3 Verifying Surfacing Compliance
10 Critical Height, Fall Height & Materials
10.1 Critical Height 10.2 Fall Height 10.3 Surfacing Material Selection
11 Surfacing Maintenance & Child Development
11.1 Surfacing Maintenance Requirements 11.2 Child Growth & Development 11.3 Age-Appropriateness of Equipment
12 Site, Materials & Layout
12.1 Site Selection, Shade & Drainage 12.2 Equipment Materials & Manufacturing 12.3 Design, Layout & Signage
13 Accessibility, Use Zones & Recalls
13.1 Accessibility Requirements 13.2 Use Zones 13.3 Industry Trends, Recalls & Alerts
14 Audit & Inspection Systems
14.1 Development and Use of Audit Forms 14.2 Development and Use of Inspection Forms 14.3 Factors Affecting Inspection Frequency
15 Nonlisted Equipment, Corrective Action & Removal
15.1 Evaluating Equipment Not Listed in the Standards 15.2 Corrective Action & Maintenance Methods 15.3 Taking Equipment Out of Service
16 Records, Site History & Compliance Documents
16.1 Record-Keeping Requirements 16.2 The Site History File 16.3 Manufacturer & Installer Compliance Documents
17 Investigations, Standard of Care & Ethics
17.1 Injury Reporting & Accident Investigation 17.2 Standard of Care Policies & Implementation 17.3 CPSI Code of Professional Conduct
7.1 Slides
Key Takeaways Explain This Topic AI
CPSC 2025 §5.3.6 names five field types: straight, spiral (toddlers and preschoolers limited to one 360° turn or less), tube (minimum interior diameter 23 inches), embankment (chute bottom no more than 12 inches above surrounding ground), and roller (0.19-inch / 3/16-inch crush-shear gap).
NRPA Table / F1487 non-spiral slides: 60-inch clear height above the bedway, 14-inch minimum transition-platform depth, 4-inch sidewalls, 11-inch minimum exit region, 30-inch minimum radius of curvature, and 21-inch minimum side clearance in the non-entanglement zone.
Chute minimum width is 12 inches for ages 2–5 and 16 inches for ages 5–12. Slides 48 inches or lower have a maximum exit height of 11 inches; slides taller than 48 inches must exit 7 to 15 inches above the surfacing.
Slide exit use zone is 72 to 96 inches and must not overlap another equipment use zone (parallel slide paths may share). Embankment slides have no slide use zone when height above the surfacing is 12 inches or less, but still require a 40-inch minimum fall height.
Entanglement at the hood, platform-to-chute junction, and sidewalls is the life-safety finding. Bare metal in sun is a CPSC burn hazard. Do not slide tandem or with a child in a lap.
Last updated: August 2026
7.1 Slides
Domain 1O for slides is a measurement chapter with a life-safety overlay. The U.S. Consumer Product Safety Commission (CPSC) Public Playground Safety Handbook , Publication 325 (July 2025) §5.3.6 is the narrative: types, platforms, chutes, exits, use zones, heat, and clothing entanglement. ASTM International F1487-21 and the NRPA Table of Dimensions (Rev 1/2024) — the sheet in the exam room — give the ages 2–5 and 5–12 numbers you will be scored on. Do not drop a CPSC toddler (6–23 months, ASTM F2373) row into an F1487 2–12 stem.
Children will descend a chute sitting, kneeling, standing, head-first, or in a pile. CPSC §5.3.6 tells owners to discourage those other positions. Your job on the audit is to make the hardware forgive a bad ride: a sitting transition, a wide enough bedway, a rounded exit, an empty use zone, and no clothing catch at the hood or along the sidewalls.
Types you must name on the field
Straight slide. An open chute that drops in one plane. The Table’s non-spiral numbers apply in full: 60-inch clear height above the bedway, 4-inch sidewalls, 11-inch exit region, 30-inch minimum radius of curvature.
Spiral slide. The chute wraps. Apply the same sidewall, slope, and exit rules where they still make geometric sense, then look for the spiral-only injury: lateral discharge off the open side. CPSC §5.3.6.3.3 limits toddlers and preschoolers to a short spiral — one 360° turn or less — because those children do not yet keep postural control through a long wrap.
Tube slide. An enclosed chute. Minimum interior diameter 23 inches. Provide barriers so children cannot climb or slide on the outside of the tube. Supervision is harder because the child disappears; that is a management note, not a substitute for the 23-inch interior.
Embankment slide. Built on grade. The chute bottom sits no more than 12 inches above the surrounding ground (NRPA Table: maximum chute-to-surfacing 12 inches ). There is no transition platform — CPSC exempts embankments from the 14-inch platform rule. If the height of the chute above the surfacing is 12 inches or less , the Table does not require a slide use zone. Surfacing still has to match a minimum fall height of 40 inches . Provide something at the entrance that stops skateboards, skates, and bikes from using the slope as a ramp.
Roller slide. Same sidewall, slope, and exit rules, plus a crush/shear test: the gap between adjacent rollers, and between the roller ends and the stationary frame, must not admit the 0.19-inch (CPSC: less than 3/16 inch ) probe. Missing rollers and seized bearings are a current finding even if the gap passed last year.
Transition platform (CPSC §5.3.6.2 and the Table)
Every slide that is not an embankment needs a horizontal transition platform so the child can go from standing to sitting before the bedway drops. The NRPA Table / F1487 depth is 14 inches minimum . CPSC adds a toddler-only 19-inch depth. The platform must be at least as wide as the chute , surrounded by the guardrail or barrier that the deck height requires (Chapter 6.2), and free of spaces or gaps between the deck and the chute start — that gap is the classic drawstring catch .
Handholds (except on a tube, where the tube rim is the hold) must reach high enough for the largest standing child and low enough for the smallest sitting child. A hood, guardrail, or other channeling device must put the child into a sitting posture before the slope. A missing hood is not a style choice; it is how a standing launch starts.
Chute, exit, and the Table of Dimensions
Memorize the Table. You will not have time to hunt it under a timed item.
- Criterion (NRPA Table / F1487 unless noted) Number
- Non-spiral clear height above bedway 60 in
- Transition platform minimum depth (ages 2–12) 14 in
- Sidewall minimum height 4 in
- Exit region minimum length (ages 2–12) 11 in
- Minimum radius of curvature (ages 2–12) 30 in
- Chute minimum width, ages 2–5 12 in
- Chute minimum width, ages 5–12 16 in
- Slides 48 in or less high: maximum exit height 11 in
- Slides greater than 48 in high: exit height 7–15 in
- Slide exit use zone 72–96 in
- Non-entanglement / clearance zone, minimum side clearance 21 in
- Tube interior diameter (CPSC §5.3.6.3.5) 23 in min
- Embankment chute-to-surfacing maximum 12 in
- Embankment minimum fall height 40 in
- Roller crush/shear probe 0.19 in
CPSC §5.3.6.3.4 adds slope language the Table does not print. For preschool- and school-age children the average incline is no more than 30° (height-to-length ratio 0.577), and no section may be steeper than 50° . Toddler averages cap at 24° with no section over 30° . Flat open chutes need 4-inch sides that are an integral part of the chute — no gap between sidewall and bedway (roller slides excepted). A curved-cross-section chute still has to produce a 4-inch vertical side when you lay the age-group width bar across the bedway ( 12 inches preschool, 16 inches school-age; CPSC also publishes an 8-inch toddler bar).
The exit region is where speed becomes a standing child. For ages 2–12 the Table wants at least 11 inches of exit, a 30-inch minimum radius into that region, rounded or curved lips, and an exit plane between 0 and –4° . Height of that lip above the surfacing: maximum 11 inches if the slide is 48 inches or lower ; 7 to 15 inches if the slide is taller than 48 inches . A 10-foot wave slide that dumps a child 4 inches onto compacted mulch is an exit-height fail and a surfacing fail. CPSC’s toddler exit is a different row: 7 to 10 inches long if any portion of the chute exceeds 24°, no more than 6 inches above the surfacing, and at least an 18-inch radius — do not substitute those numbers on a 2–12 public slide.
Fall height for a slide, CPSC §5.3.6.6, is the distance from the transition platform to the protective surfacing. Embankments have no platform; carry the Table’s 40-inch minimum fall height instead.
Use zone, entanglement, heat, and tandem riding
CPSC §5.3.6.5 and the Table’s 72–96 inch exit band are the same rule in two units. Sides and access: 6 feet from the perimeter (that side band is not required for embankments or for slides already inside a composite’s 6-foot envelope — see §5.3.9). The exit use zone must not overlap any other equipment’s use zone; two slides may share exit surfacing only if their paths are parallel . Slides 6 feet or shorter : 72 inches of exit. Slides taller than 6 feet : exit length equals the slide height , up to 96 inches .
Entanglement is the life-safety finding on a slide. Hoods, the platform-to-chute junction, and sidewall fasteners have killed children when a hood drawstring or a jacket toggle caught and the child’s body kept going. CPSC §5.3.6.7: projections up to 3 inches in diameter must not stand more than 1/8 inch off the slide; there should be no gaps at the top where the chute meets the platform. Run the slide protrusion gauges from Appendix B.2.3 along the hood, the junction, and both sidewalls. The Table’s 21-inch side clearance is the non-entanglement zone beside the chute — a fence, shade-sail cable, or adjacent deck that crowds the bedway inside 21 inches is a clothing-catch geometry even if the fastener itself is flush. CPSC §5.3.6.8 extends the same entanglement rules to any other component whose primary foreseeable use is sliding .
Metal in sun is a burn hazard. CPSC §5.3.6 opens with it: do not use bare metal on platforms, chutes, or steps. Shade the metal or specify plastic or coated metal. A legal 14-inch platform on a south-facing steel chute can still hospitalize a child in seconds; write the heat finding even when every dimension passes.
Do not allow tandem sliding or a child in a caregiver’s lap. Extra mass raises exit speed into a use zone sized for one rider, and the lap-held child is crushed or ejected. That is a supervision and signage control, not a tape measurement, but the exam will pair it with the hardware rules.
Walk Domain 1O for slides in this order:
Name the type (straight, spiral, tube, embankment, roller).
Measure the 14-inch platform (or confirm the embankment exemption).
Probe the hood, platform-to-chute junction, and sidewalls for entanglement.
Tape chute width, 4-inch sidewalls, 60-inch non-spiral clear height, and 21-inch side clearance.
Measure exit length, radius, and the 11-inch or 7–15-inch exit height.
Walk the 72–96 inch exit use zone, then check heat and tandem-use signage.
That sequence keeps a Priority 1 clothing catch from hiding behind a pretty exit radius.