Study guide
10.3 Thrombosis, Air Embolism & Device-Related Systemic Events
CRNI® Exam Study Guide Certified Registered Nurse Infusion
Track your progress as you read
Finished sections get a check mark.
1 Introduction & Exam Overview
1.1 Current Exam Facts 1.2 Eligibility, Application & Testing Windows 1.3 Scoring, Results & Recertification
2 Anatomy & Physiology for Infusion Practice
2.1 Vascular Anatomy & Physiology for Infusion 2.2 Body Positioning for Catheter Insertion & Removal 2.3 Vein Selection & Patient Assessment
3 Infection Prevention & Control
3.1 Infection Prevention Strategies & Standard Precautions 3.2 Chain of Infection in Infusion Practice 3.3 Bloodstream Infections & CLABSI Prevention 3.4 Phlebitis: Prevention, Grading & Management
4 Phlebotomy in Infusion Practice
4.1 Blood Sampling & Blood Culture Collection 4.2 Therapeutic Phlebotomy
5 Infusion Equipment & Technology
5.1 Solution Containers, Administration Sets & Filters 5.2 Add-on Devices, Administration Devices & Closed Systems 5.3 Vein Location Devices, Navigation Tools & Securement
6 Peripheral Venous Access Devices
6.1 Short & Long Peripheral Intravenous Catheters 6.2 Midline Catheters 6.3 Peripheral Device Selection Criteria
7 Central Venous Access Devices
7.1 Peripherally Inserted Central Catheters (PICC) 7.2 Non-tunneled Central Venous Catheters 7.3 Tunneled Central Venous Catheters 7.4 Implanted Ports
8 Alternate Access Routes & Device Maintenance
8.1 Subcutaneous Infusion Access 8.2 Intraosseous Access 8.3 Device Maintenance & Care Protocols
9 Special Populations in Infusion Therapy
9.1 Older Adults & Chronic Renal Conditions 9.2 Pediatrics, Immunocompromised, Oncology & Bariatrics
10 Device-Related Complications
10.1 Infiltration & Extravasation 10.2 Catheter Occlusion 10.3 Thrombosis, Air Embolism & Device-Related Systemic Events
11 Fluid & Electrolyte Balance
11.1 Body Composition & Fluid Balance 11.2 Fluid Volume Excess & Deficit 11.3 Electrolyte Disorders 11.4 Maintenance & Replacement Fluids
12 Parenteral Nutrition
12.1 Parenteral Nutrition: Solution Composition 12.2 PN Infectious, Metabolic & Mechanical Complications
13 Anti-infectives, Blood Products & Biologics
13.1 Anti-infective Infusion Therapy 13.2 Blood Products & Transfusion Therapy 13.3 Biologics & Immunologic Therapies
14 Antineoplastic, Cardiovascular & Pain Infusions
14.1 Antineoplastic Infusion Therapy 14.2 Cardiovascular Infusions 14.3 Pain Management Infusions
15 Therapy-Related Complications & Hazardous Drugs
15.1 Rate-Related Complications 15.2 Adverse Drug Reactions 15.3 Hazardous Drug Exposure & Waste Disposal
16 Professional Practice, Documentation & Quality
16.1 Assessment, Consent & Collaborative Care Planning 16.2 Documentation, Laws & Regulatory Agencies 16.3 Evidence-Based Practice & Performance Improvement
10.3 Thrombosis, Air Embolism & Device-Related Systemic Events
Key Takeaways Explain This Topic AI
Catheter-related venous thrombosis presents with limb swelling, pain, and sometimes collateral veins; duplex ultrasound is the usual first-line diagnostic approach, with anticoagulation and selective catheter removal decisions guided by the care team.
Air embolism risk rises with open hubs, disconnected tubing, and insertion/removal of central lines—especially when the insertion site is above heart level during inspiration.
Classic emergency positioning for suspected venous air embolism is left lateral Trendelenburg (Durant maneuver) plus clamp the source, high-flow oxygen, and emergency response—not delayed observation.
Pinch-off syndrome (subclavian compression) can cause intermittent occlusion and catheter fracture with risk of catheter embolism; migration and fracture are additional mechanical systemic threats.
Exam traps include treating air embolism with casual upright positioning only, ignoring arm swelling as “infiltration,” and failing to clamp an open central line hub.
Last updated: August 2026
Systemic and vessel-level complications: why they matter
Quick Answer: Catheter-related thrombosis causes limb swelling and may require ultrasound and anticoagulation , with removal decided case-by-case. Air embolism is an emergency: clamp , prevent further air entry, place the patient in left lateral Trendelenburg (Durant) when venous air embolism is suspected, give oxygen , and activate emergency response. Know pinch-off , migration , fracture , and catheter embolism as mechanical threats that become systemic events.
Domain 2C extends past the insertion site skin. A device that is “working” for infusions can still occlude a vein, seed emboli, or entrain air into the central circulation. Exam items often present mixed signs—swelling that is not a simple infiltrate, sudden respiratory distress after a hub disconnect, or intermittent occlusion that predicts fracture.
- Catheter-related thrombosis (CRT)
- Pathophysiology in brief
Vascular catheters injure endothelium, alter flow (stasis), and may sit in a hypercoagulable host—Virchow’s triad applied to device care. Fibrin and thrombus can form along the catheter, at the tip, or in the vein wall lumen (e.g., upper extremity DVT associated with PICC or other CVAD).
Recognition
Suspect CRT when you find:
- Unilateral arm (or neck/face) swelling on the side of the device
- Pain, tightness, or heaviness of the limb
- Visible collateral veins over the chest or shoulder (chronic or subacute compensation)
- Erythema that is venous rather than simple phlebitis pattern
- Functional problems: occlusion, inability to aspirate, or infusion resistance plus limb findings
Rarely, signs of superior vena cava syndrome with central stenoses/thromboses (facial plethora, bilateral arm swelling—urgent escalation)
Do not dismiss unilateral arm swelling as “just infiltration” when the catheter is central or the swelling is diffuse along the limb rather than localized to a peripheral insertion site.
- Diagnosis and management principles
- Duplex ultrasound is the usual first-line imaging for upper extremity DVT suspicion
Other imaging may be used when ultrasound is inconclusive or central thoracic veins need evaluation (provider-directed)
Anticoagulation is commonly indicated for CRT when not contraindicated—follow hematology/vascular and institutional protocols; dosing specifics are provider-ordered
Catheter removal is not automatic for every CRT: if the line is still necessary, well positioned, and functioning, many protocols continue the catheter with anticoagulation; remove when the line is infected, nonfunctional, no longer needed, or otherwise indicated
Escalate for suspected pulmonary embolism (dyspnea, chest pain, hypoxia, tachycardia) related to venous thromboembolism
Prevention links
Right-sized device selection, ultrasound-guided placement, tip position verification, minimizing unnecessary central access, early removal, and attention to flush/occlusion prevention all reduce thrombotic burden. PICCs carry meaningful upper-extremity DVT risk—justify the device against alternatives.
- Air embolism
- How air enters
Venous air embolism associated with vascular access occurs when a pressure gradient draws air into the venous system. High-risk moments:
- Disconnected tubing or open needleless connectors on central lines
- Unclamped hubs during tubing changes
- Catheter insertion or removal without proper positioning and site occlusion technique
- Deep inspiration when the insertion site or open hub is above the level of the heart
Cracked catheters, loose connections, or empty infusion containers with unclamped open systems in vulnerable configurations
Peripheral IVs can theoretically entrain air but central venous access presents the classic high-risk pathway to the right heart and pulmonary circulation.
Clinical presentation
Sudden dyspnea, chest pain, cough, hypoxia, tachycardia or hypotension, altered mentation, mill-wheel murmur (classic but not required), anxiety, or cardiovascular collapse. Any sudden respiratory/hemodynamic change during line manipulation is air embolism until proven otherwise in the differential.
Immediate actions (memorize the sequence)
Prevent further air entry: clamp the catheter, cover open hubs with a finger/occlusive measure, reconnect closed systems
Call for emergency help / rapid response / code as indicated
Position the patient in left lateral Trendelenburg ( Durant maneuver ) for suspected venous air embolism—left side down and head down aims to trap air in the right ventricular apex away from the pulmonary outflow tract (classic teaching still tested)
Administer high-flow oxygen (and advanced airway support per ACLS as needed)
Support circulation; prepare for provider interventions (including possible aspiration of air from a correctly positioned central catheter in specialized settings)
- Do not leave the patient upright “to help breathing” as the sole response while a central hub remains open
- Prevention of air embolism
- Clamp before opening the system; use Luer-lock connections
- Prime sets fully; avoid large air in lines
During CVAD removal: supine or Trendelenburg as appropriate, patient performs Valsalva or hum during removal if able, apply occlusive dressing immediately, and keep the site sealed per protocol for the ordered duration
- Never leave central hubs unattended and open
- Educate patients not to disconnect ambulatory tubing casually
- Pinch-off syndrome, fracture, migration, and catheter embolism
- Pinch-off syndrome
Pinch-off syndrome occurs when a subclavian catheter is compressed between the clavicle and first rib . Clues:
- Intermittent occlusion related to arm/shoulder position
- Difficulty infusing that resolves with position change
- Risk of catheter weakening and fracture with distal fragment embolization
Management is not endless alteplase trials—recognize the mechanical syndrome, stop risky use, notify the provider, and plan imaging/removal/reposition strategies. Prevention includes careful insertion site technique and awareness that subclavian routes carry this unique risk profile compared with some internal jugular approaches.
Catheter migration
Tips can migrate from cavoatrial junction regions into the right atrium, jugular veins, or contralateral vessels. Consequences include arrhythmias, reduced function, thrombosis risk, and perforation risk in extreme cases. External length changes, new ear/neck sensations with infusions, or unexplained arrhythmias after previous stable function should trigger assessment and imaging confirmation of tip position.
Catheter fracture and catheter embolism
Fracture may follow pinch-off, trauma, scissors accidents during dressing changes, or manufacturing/material failure. A free fragment can embolize centrally. Signs: sudden loss of function, visible crack, patient report of a “snap,” swelling along the tunnel, or acute cardiopulmonary symptoms. Emergency response , imaging localization, and interventional retrieval pathways are provider-led—nursing priorities are stop use, prevent air/blood loss from the fracture site, stabilize, and escalate immediately.
Related device-systemic events also include guidewire embolism during insertion (never lose control of the wire) and port reservoir separation in implanted systems—rare but serious.
Differential thinking across Chapter 10
- Presentation Think first
- Localized cool swelling at PIV during non-vesicant Infiltration
- Burning, blanching on vesicant Extravasation emergency pathway
- Cannot aspirate/infuse, no limb swelling Occlusion differential (mechanical → thrombotic → chemical)
- Unilateral arm swelling + CVAD Catheter-related thrombosis
- Sudden distress + open central hub/disconnect Air embolism
- Positional subclavian occlusion Pinch-off until proven otherwise
- Documentation, disclosure, and system learning
Systemic device events require precise timelines: when tubing disconnected, position of patient, estimated air exposure, neurologic/respiratory status, and interventions. Many institutions treat air embolism and catheter fragment embolism as serious safety events with disclosure and root-cause analysis. Your chart should show the clamp, position, oxygen, and notification sequence clearly.
- Exam traps for systemic device complications
- Continuing to troubleshoot a “positional occlusion” indefinitely without considering pinch-off fracture risk
- Removing a still-needed, functional CVAD automatically for every CRT without team decision-making
Sitting the patient fully upright as the only response to suspected venous air embolism while leaving the system open
- Confusing local infiltration with extensive limb DVT swelling
- Failing to apply occlusive technique at central line removal
- Using scissors carelessly at dressing change → catheter cut and embolism risk
- Putting Domain 2C together
Safe infusion practice is layered: choose and secure the right device, prevent infection (Chapter 3), maintain patency (flush/lock), assess continuously, and respond with mechanism-specific algorithms when complications appear. For thrombosis and embolism, speed and correct first moves matter as much as later specialty care. If you can stop air entry, position for Durant, support oxygenation, recognize CRT versus infiltrate, and escalate fracture/embolism immediately, you will handle the highest-acuity device items on the CRNI exam with confidence.
Review this section with 10.1 and 10.2 as a single complications map: local leak, lumen block, vessel clot, air, and device mechanical failure—each with a distinct first action.