Study guide
9.1 AWS D1.1:2025 Code Structure and Navigation
AWS CWI Certified Welding Inspector Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction to the AWS CWI Certification
What Is the AWS CWI Certification? CWI Exam Structure: Parts A, B, and C Eligibility Requirements and Application
2 1. Welding Processes and Fundamentals
1.1 SMAW — Shielded Metal Arc Welding (Stick) 1.2 GMAW — Gas Metal Arc Welding (MIG/MAG) 1.3 FCAW — Flux-Cored Arc Welding 1.4 GTAW — Gas Tungsten Arc Welding (TIG) 1.5 SAW — Submerged Arc Welding 1.6 Other Welding, Cutting Processes, and Process Variables
3 2. Welding Metallurgy and Heat Control
2.1 The Iron-Carbon Phase Diagram 2.2 The Heat-Affected Zone (HAZ) 2.3 Preheat and Interpass Temperature 2.4 Hydrogen-Induced Cracking (HIC) 2.5 Distortion and Residual Stress
4 3. Weld Discontinuities and Defects
3.1 Discontinuity vs. Defect — Definitions and Concepts 3.2 Cracks — Types, Causes, and Significance 3.3 Porosity and Inclusions 3.4 Incomplete Fusion and Incomplete Joint Penetration 3.5 Geometric Discontinuities: Undercut, Overlap, and Profile
5 4. Nondestructive Examination (NDE) Methods
4.1 Visual Testing (VT) 4.2 Liquid Penetrant Testing (PT) 4.3 Magnetic Particle Testing (MT) 4.4 Radiographic Testing (RT) and Ultrasonic Testing (UT)
6 5. Welding Symbols and Terminology
5.1 Anatomy of a Welding Symbol (AWS A2.4) 5.2 Joint Types, Weld Types, and Welding Positions 5.3 Essential Welding Definitions and Terminology
7 6. WPS, PQR, and Welder Qualification
6.1 Welding Procedure Specification (WPS) 6.2 Procedure Qualification Record (PQR) 6.3 Welder Performance Qualification (WPQ)
8 7. Destructive Testing Methods
7.1 Tensile Testing 7.2 Guided Bend, Nick Break, and Fillet Weld Break Tests 7.3 Impact Testing and Hardness Testing
9 8. Welding Safety and Inspector Duties
8.1 Welding Safety Hazards and Prevention 8.2 CWI Duties and Responsibilities 8.3 Welding-Related Calculations
10 9. AWS D1.1 Code Application (Part C)
9.1 AWS D1.1:2025 Code Structure and Navigation 9.2 Clause 5 — Prequalification Requirements 9.3 Clause 8 — Inspection and Acceptance Criteria 9.4 Part B Practical Exam Preparation
11 10. Exam Strategies and Comprehensive Review
10.1 Part A (Fundamentals) Exam Strategies 10.2 Part C (Code Application) Exam Strategies 10.3 Comprehensive Review — 25 Practice Questions
9.1 AWS D1.1:2025 Code Structure and Navigation
Key Takeaways Explain This Topic AI
AWS D1.1:2025 has 11 clauses plus normative/informative annexes; learn which question type each clause answers, not page numbers
Scope: steel structures, base metal 1/8 in [3 mm] and thicker, specified yield up to 100 ksi [690 MPa] — not ASME, API, D1.2, D1.3, or D1.4 work
Tab the ten key references: Tables 5.3, 5.4, 5.8, 7.7, 8.1, 8.2 and Figures 5.1, 5.2, plus the welding-symbol and form annexes
Part C is open-book and tests locate/interpret/apply/cross-reference, not memorization
Budget roughly 2 to 3 minutes per question; mark and return rather than stalling
Use the Table of Contents and Index before flipping; decide the target clause from the stem before opening the book
Last updated: June 2026
The Code Behind Part C
AWS D1.1/D1.1M:2025 — Structural Welding Code – Steel is the most commonly selected code book for Part C of the Certified Welding Inspector (CWI) exam. Part C is open-book , so it does not reward memorization — it rewards the ability to locate, interpret, and apply a requirement quickly. The candidate who knows exactly where preheat lives, which figure shows a prequalified joint, and which row of Table 8.1 governs undercut will finish; the candidate who reads cover-to-cover will run out of time.
D1.1 governs the welding of statically and cyclically loaded steel structures built from carbon and low-alloy steels with a specified minimum yield strength up to 100 ksi [690 MPa] and a base-metal thickness of 1/8 in [3 mm] and thicker . It does not cover pressure vessels (ASME), pipelines (API 1104), sheet steel under 1/8 in (that is D1.3), reinforcing bar (D1.4), or aluminum (D1.2). Knowing the scope limit in Clause 1 is itself a common Part C trap.
The Eleven Clauses (2025 Renumbering)
The 2020 edition renumbered the historic nine clauses to a normative structure that the 2025 edition keeps. Learn what type of question each clause answers:
- Clause Title The question it answers
- 1 General Requirements Scope, base-metal/strength limits, definitions of roles, responsibilities
- 2 Normative References Which other standards (ASTM, AWS A5.x, ASNT) are invoked
- 3 Terms and Definitions Exact A3.0-based meaning of a term used in the code
- 4 Design of Welded Connections Allowable/ design strength, effective throat/area, fatigue categories
- 5 Prequalification of WPSs When you may skip PQR testing — joints, metals, fillers, preheat
- 6 Qualification How to qualify a WPS by test (PQR) and qualify welders/operators
- 7 Fabrication Workmanship: cutting, fit-up, tolerances, profiles, repair
- 8 Inspection Inspector duties, NDT methods, visual/UT/RT acceptance criteria
- 9 Stud Welding Arc stud welding application, qualification, and inspection
- 10 Tubular Structures Round/box tubular connection design, qualification, acceptance
- 11 Strengthening and Repair Modifying or repairing existing welded structures in service
- Annexes Matter Too
After the clauses, normative annexes (mandatory when referenced) and informative annexes (guidance) follow. Candidates should tab the annex that lists standard welding symbols , the ASTM/filler-metal grouping annex, and sample WPS/PQR/qualification forms . A question that says "per the code, what symbol element indicates field weld?" sends you to an annex, not a clause.
What Part C Actually Tests
Part C consists of 150 questions in the closed-book half is Part A; Part C is the code-book module of roughly 46 questions answered with your tabbed D1.1 in hand. Questions fall into recognizable patterns:
- Locate a value ("what is the minimum preheat for…?")
- Interpret a table or figure (read a prequalified joint detail's tolerances)
- Apply criteria to a scenario ("a 1/32 in undercut on a 14 in static fillet — accept or reject?")
- Cross-reference clauses (use Table 5.3 steel category to enter Table 5.8 preheat )
- Tabbing and Navigation Strategy
Tab by destination, not by page. Color-code Clause 5 (prequalification), Clause 7 (workmanship), and Clause 8 (acceptance) differently; add bright tabs on Table 5.3, 5.4, 5.8, 7.7 (min fillet size), 8.1 (visual), and 8.2 (UT) .
Use the Table of Contents and Index first. They are faster than flipping; the index points to the exact clause for a term.
No permanent marking inside the book — tabs are allowed, but highlighting/writing in the code is typically prohibited; confirm the AWS rules for your exam date.
Budget your time. With about 130 minutes for the module, you have roughly 2 to 3 minutes per question . If a value will not surface in 3 minutes, mark it, move on, and return.
Read the stem before opening the book — decide which clause/table you need, then open once.
A Map of Where Things Live
Internalizing this mental map turns a 3-minute hunt into a 20-second lookup. Memorize the home clause for each common topic so you open the book exactly once:
- If the question is about... Go to
- Scope, strength limit, definitions of inspector roles Clause 1
- Effective throat, weld strength, fatigue stress category Clause 4
- "Is this WPS prequalified?", joint details, preheat Clause 5
- Qualifying a WPS by test (PQR), welder/operator tests Clause 6
- Minimum fillet size, fit-up tolerance, weld profile, repair Clause 7
- Inspector duties, visual/UT/RT acceptance, re-inspection Clause 8
- Studs / shear connectors Clause 9
- HSS and pipe connections Clause 10
- Worked Navigation Example
Suppose Part C asks: "For SMAW on 1-1/4 in A572 Gr 50 with low-hydrogen electrodes, what is the minimum preheat?" The path is a two-table cross-reference : (1) open the base-metal table to read the steel category for A572 Gr 50; (2) carry that category and the 1-1/4 in thickness into the preheat table (5.8) ; (3) read the minimum temperature at the intersecting cell. A candidate who tabs both tables and knows the lookup order solves it in under a minute. A candidate who starts reading Clause 5 text from the top will burn three minutes and may still miss it.
Editions and Why They Matter
The 2025 edition is current; the 2020 edition introduced the modern 11-clause numbering and the SI-then-USC presentation. Older study material may cite the legacy nine-clause scheme (where Inspection was Clause 6, not 8). On exam day you use whatever edition AWS issues for your seat — read the spine and the table-of-contents numbering before you start tabbing, because clause and table numbers shifted between editions. Never answer a navigation question from an outdated tab set.
For the Exam: Most candidates who fail Part C do so on time , not knowledge. Practice timed code drills until you can land on any of the ten key tables in under fifteen seconds.