Study guide
9.2 Clause 5 — Prequalification Requirements
AWS CWI Certified Welding Inspector Exam
Track your progress as you read
Finished sections get a check mark.
1 Introduction to the AWS CWI Certification
What Is the AWS CWI Certification? CWI Exam Structure: Parts A, B, and C Eligibility Requirements and Application
2 1. Welding Processes and Fundamentals
1.1 SMAW — Shielded Metal Arc Welding (Stick) 1.2 GMAW — Gas Metal Arc Welding (MIG/MAG) 1.3 FCAW — Flux-Cored Arc Welding 1.4 GTAW — Gas Tungsten Arc Welding (TIG) 1.5 SAW — Submerged Arc Welding 1.6 Other Welding, Cutting Processes, and Process Variables
3 2. Welding Metallurgy and Heat Control
2.1 The Iron-Carbon Phase Diagram 2.2 The Heat-Affected Zone (HAZ) 2.3 Preheat and Interpass Temperature 2.4 Hydrogen-Induced Cracking (HIC) 2.5 Distortion and Residual Stress
4 3. Weld Discontinuities and Defects
3.1 Discontinuity vs. Defect — Definitions and Concepts 3.2 Cracks — Types, Causes, and Significance 3.3 Porosity and Inclusions 3.4 Incomplete Fusion and Incomplete Joint Penetration 3.5 Geometric Discontinuities: Undercut, Overlap, and Profile
5 4. Nondestructive Examination (NDE) Methods
4.1 Visual Testing (VT) 4.2 Liquid Penetrant Testing (PT) 4.3 Magnetic Particle Testing (MT) 4.4 Radiographic Testing (RT) and Ultrasonic Testing (UT)
6 5. Welding Symbols and Terminology
5.1 Anatomy of a Welding Symbol (AWS A2.4) 5.2 Joint Types, Weld Types, and Welding Positions 5.3 Essential Welding Definitions and Terminology
7 6. WPS, PQR, and Welder Qualification
6.1 Welding Procedure Specification (WPS) 6.2 Procedure Qualification Record (PQR) 6.3 Welder Performance Qualification (WPQ)
8 7. Destructive Testing Methods
7.1 Tensile Testing 7.2 Guided Bend, Nick Break, and Fillet Weld Break Tests 7.3 Impact Testing and Hardness Testing
9 8. Welding Safety and Inspector Duties
8.1 Welding Safety Hazards and Prevention 8.2 CWI Duties and Responsibilities 8.3 Welding-Related Calculations
10 9. AWS D1.1 Code Application (Part C)
9.1 AWS D1.1:2025 Code Structure and Navigation 9.2 Clause 5 — Prequalification Requirements 9.3 Clause 8 — Inspection and Acceptance Criteria 9.4 Part B Practical Exam Preparation
11 10. Exam Strategies and Comprehensive Review
10.1 Part A (Fundamentals) Exam Strategies 10.2 Part C (Code Application) Exam Strategies 10.3 Comprehensive Review — 25 Practice Questions
9.2 Clause 5 — Prequalification Requirements
Key Takeaways Explain This Topic AI
Prequalification (Clause 5) lets a WPS skip PQR testing only when ALL six conditions are met
Prequalified processes are SMAW, SAW, GMAW (no short-circuit on CJP grooves), and FCAW; GTAW is never prequalified
Base metal (Table 5.3), matching filler (Table 5.4), joint detail (Figs 5.1/5.2), and preheat (Table 5.8) must all be satisfied
Preheat is a three-input lookup: steel category, thickest part at the joint, and process/hydrogen level
Any joint fit-up outside the figure's tolerances voids prequalification — a PQR is then required
- Common steels: A36, A572 Gr 50, A992, A500, A588/A709
- Last updated: June 2026
The Prequalification Concept
Clause 5 lets a fabricator use a Welding Procedure Specification (WPS) without qualifying it by destructive test (no Procedure Qualification Record, PQR ) — provided the procedure stays inside a tightly bounded envelope the code has already proven. This is unique to D1.1 and saves enormous time and cost, which is why Part C tests it heavily. The classic question form is: "Given these conditions, is this WPS prequalified, or does it require a PQR?"
A WPS is prequalified only if EVERY one of the following is satisfied :
Process is one of the four prequalified processes — SMAW, SAW, GMAW, FCAW . (GMAW short-circuiting transfer is not prequalified for CJP groove welds.) GTAW is never prequalified and always needs a PQR.
Base metal is listed in the prequalified base-metal table (historically Table 5.3 , renumbered in current editions — tab it regardless of number).
Filler metal matches the base metal per the matching-filler table (Table 5.4) and meets the correct AWS A5.x classification and strength group.
Joint detail matches a prequalified configuration in Figure 5.1 (CJP) or Figure 5.2 (PJP) within all listed tolerances.
Minimum preheat and interpass temperature meets the prequalified preheat table ( Table 5.8 ).
All other Clause 5 limits are met — welding positions, electrode/flux conditions, technique, and essential-variable ranges.
If any single condition fails, the procedure is not prequalified and must be qualified by test per Clause 6 .
Reading the Prequalified Base-Metal and Filler Tables
The base-metal table organizes steels by ASTM specification, grade, steel group, and a preheat category (A, B, C, D...) that you carry forward into the preheat table. The matching-filler table then pairs that steel group with acceptable filler classifications.
- Common steel Typical use Spec'd min yield
- A36 General structural plate/shapes 36 ksi [250 MPa]
- A572 Gr 50 HSLA plate and shapes 50 ksi [345 MPa]
- A992 Standard W-shape (wide-flange) 50 ksi [345 MPa]
- A500 Gr B/C HSS round/rectangular tubing 42–50 ksi
- A588 / A709 Weathering / bridge steel 50 ksi [345 MPa]
- Cross-Referencing Preheat (Table 5.8)
Minimum preheat and interpass temperature is a three-input lookup — a favorite cross-reference question:
- Steel category (from the base-metal table),
- Thickness of the thickest part at the point of welding, and
Process / hydrogen level (low-hydrogen vs non-low-hydrogen filler).
The table returns a minimum temperature (for example, thicker low-hydrogen welds may require 150°F or 225°F [65°C or 110°C] ). The trap: candidates pick thickness of the thinner part. The code uses the thickest part at the joint .
Reading a Prequalified Joint Detail
Each Figure 5.1/5.2 entry carries a joint designation (for example, B-U2 or TC-U4b) and specifies the groove type (square, V, bevel, U, J), groove angle , root opening , root face , permitted positions , allowed processes , backing (with/without, backgouge), and thickness range . If the actual fit-up falls outside any listed tolerance , prequalification is void.
- Joint element Why it matters
- Groove angle Too small starves access/fusion; outside range voids prequal
- Root opening Controls penetration and backing need
- Root face Affects burn-through and root fusion
- Backing / backgouge Distinguishes CJP from PJP and sets process limits
- Prequalification Is Not Welder or Inspection Relief
A frequent conceptual trap: prequalification only exempts the WPS from procedure qualification (PQR) . It does not waive welder/operator qualification (still required per Clause 6), and it does not reduce inspection or acceptance criteria (Clause 8 applies in full). A prequalified joint welded by an unqualified welder is still non-conforming, and a prequalified weld with a crack is still rejected. Keep the three concepts separate: procedure (Clause 5/6), personnel (Clause 6), and product acceptance (Clause 8).
Filler-Metal and Hydrogen Subtleties
The matching-filler table pairs a steel group with an electrode strength level and AWS A5.x classification (for example, E70xx SMAW electrodes for many 50 ksi steels). Two traps recur:
Trap Correct reading
Picking a non-matching strength Filler must match (or per design, undermatch only where the code/Engineer allows)
Ignoring low-hydrogen requirement Many steels/thicknesses require low-hydrogen electrodes (e.g., E7018, not E6010) for prequalified preheat
Electrode condition Low-hydrogen electrodes have storage/redry limits; a damp electrode invalidates the low-hydrogen basis
Essential Variables Still Bound the WPS
Even a prequalified WPS must stay inside Clause 5's essential-variable ranges — amperage, voltage, travel speed, electrode diameter, and position limits. If production drifts outside the WPS, the weld is non-conforming even though the procedure was prequalified. On Part C, a scenario that changes the welding position to one not permitted by the joint detail, or swaps to short-circuit GMAW on a CJP groove , breaks prequalification just as surely as an unlisted base metal.
Quick Prequalification Checklist
When the stem asks "prequalified — yes or no?", run this in order and stop at the first failure:
Process one of SMAW / SAW / GMAW (not short-circuit on CJP) / FCAW?
Base metal in the prequalified table?
Filler matched and correct A5.x / hydrogen level?
Joint detail matches a Figure 5.1/5.2 entry within all tolerances ?
Preheat/interpass meets Table 5.8 for the thickest part?
Position, technique, and essential variables within Clause 5 limits?
For the Exam: When asked "is it prequalified?", walk the six conditions like a checklist. The most common reason the answer is "no, requires PQR" is a non-prequalified process (GTAW) or a joint detail outside the figure's tolerance .