1 Introduction to the AWS CWI Certification

What Is the AWS CWI Certification? CWI Exam Structure: Parts A, B, and C Eligibility Requirements and Application

2 1. Welding Processes and Fundamentals

1.1 SMAW — Shielded Metal Arc Welding (Stick) 1.2 GMAW — Gas Metal Arc Welding (MIG/MAG) 1.3 FCAW — Flux-Cored Arc Welding 1.4 GTAW — Gas Tungsten Arc Welding (TIG) 1.5 SAW — Submerged Arc Welding 1.6 Other Welding, Cutting Processes, and Process Variables

3 2. Welding Metallurgy and Heat Control

2.1 The Iron-Carbon Phase Diagram 2.2 The Heat-Affected Zone (HAZ) 2.3 Preheat and Interpass Temperature 2.4 Hydrogen-Induced Cracking (HIC) 2.5 Distortion and Residual Stress

4 3. Weld Discontinuities and Defects

3.1 Discontinuity vs. Defect — Definitions and Concepts 3.2 Cracks — Types, Causes, and Significance 3.3 Porosity and Inclusions 3.4 Incomplete Fusion and Incomplete Joint Penetration 3.5 Geometric Discontinuities: Undercut, Overlap, and Profile

5 4. Nondestructive Examination (NDE) Methods

4.1 Visual Testing (VT) 4.2 Liquid Penetrant Testing (PT) 4.3 Magnetic Particle Testing (MT) 4.4 Radiographic Testing (RT) and Ultrasonic Testing (UT)

6 5. Welding Symbols and Terminology

5.1 Anatomy of a Welding Symbol (AWS A2.4) 5.2 Joint Types, Weld Types, and Welding Positions 5.3 Essential Welding Definitions and Terminology

7 6. WPS, PQR, and Welder Qualification

6.1 Welding Procedure Specification (WPS) 6.2 Procedure Qualification Record (PQR) 6.3 Welder Performance Qualification (WPQ)

8 7. Destructive Testing Methods

7.1 Tensile Testing 7.2 Guided Bend, Nick Break, and Fillet Weld Break Tests 7.3 Impact Testing and Hardness Testing

9 8. Welding Safety and Inspector Duties

8.1 Welding Safety Hazards and Prevention 8.2 CWI Duties and Responsibilities 8.3 Welding-Related Calculations

10 9. AWS D1.1 Code Application (Part C)

9.1 AWS D1.1:2025 Code Structure and Navigation 9.2 Clause 5 — Prequalification Requirements 9.3 Clause 8 — Inspection and Acceptance Criteria 9.4 Part B Practical Exam Preparation

11 10. Exam Strategies and Comprehensive Review

10.1 Part A (Fundamentals) Exam Strategies 10.2 Part C (Code Application) Exam Strategies 10.3 Comprehensive Review — 25 Practice Questions

8.1 Welding Safety Hazards and Prevention

Key Takeaways Explain This Topic AI

ANSI Z49.1, 'Safety in Welding, Cutting, and Allied Processes,' plus OSHA 29 CFR 1910/1926 govern welding safety on Part A

Apply the hierarchy of controls (elimination, substitution, engineering, administrative, PPE) — PPE is the last resort

Primary voltage (~230–575 V) is the lethal input; secondary/open-circuit voltage (20–100 V) is lower but still dangerous in wet/confined work

Arc radiation causes arc eye (UV) and retinal damage (IR); filter shade number increases with arc current and varies by process

Stainless steel → hexavalent chromium (lung cancer); galvanized → zinc/metal fume fever; control with local exhaust ventilation

Fire: clear combustibles 35 ft, hot-work permit, fire watch (OSHA 30 min / NFPA 51B 60 min); cylinders upright, O₂ ≥20 ft from fuel gas, flashback arrestors

Confined space (OSHA 1910.146): test O₂ first (safe 19.5%–23.5%), then combustibles, then toxics; permit, ventilation, outside attendant, rescue plan

Last updated: September 2026

Welding Safety and the CWI

ANSI Z49.1, Safety in Welding, Cutting, and Allied Processes, published by the American Welding Society (AWS), is a principal welding-safety reference. Applicable OSHA requirements also appear in 29 CFR 1910 (general industry) and 1926 (construction). A Certified Welding Inspector (CWI) is not a substitute for a safety officer, but the inspector is often the most knowledgeable person on the floor and is expected to recognize unsafe conditions and stop work that endangers personnel. Z49.1 addresses hazards into the same categories the exam tests: electric shock, arc radiation, fumes and gases, fire and explosion, compressed-gas hazards, and confined-space hazards.

The Hierarchy of Controls

ANSI Z49.1 and OSHA apply the standard hierarchy of controls to every hazard — pick the highest control that is feasible before relying on the lowest:

  • Rank Control Welding example
  • 1 Elimination/substitution Use a low-fume electrode; weld off-site away from the public
  • 2 Engineering controls Local exhaust ventilation (LEV); welding screens; insulated holders
  • 3 Administrative controls Hot-work permits; rotating workers to limit exposure; training
  • 4 PPE (last resort) Helmet with proper shade, FR clothing, respirator, gloves

Personal protective equipment (PPE) is the LAST line of defense, not the first — a common exam trap is to choose "give the welder a respirator" when ventilation (an engineering control) is the better answer.

The Major Hazard Categories

Memorize the categories the way ANSI Z49.1 frames them. Electric shock is the most serious immediate hazard because it can kill instantly. Burns are the most common injury, caused by arc rays, spatter, hot metal, and slag. Arc radiation produces ultraviolet (UV) and infrared (IR) energy that injures the eyes and skin. Fumes and gases create the most significant long-term (chronic) health risk. Fire and explosion are the leading cause of property loss, and confined-space work multiplies every other hazard. The remainder of this section drills into each category with the exact numbers the exam expects.

Electric Shock — Primary vs. Secondary Voltage

Arc-welding power sources draw high-voltage utility power and step it down to a usable welding circuit, so a CWI must distinguish the two voltages.

Voltage Where it appears Typical value Risk

Primary (input) voltage The line feeding the power source (utility/branch circuit) 230–575 V AC Can be instantly fatal ; only qualified electricians work inside the case

Secondary (open-circuit) voltage, OCV The welding circuit between electrode and work before the arc strikes Typically 20–100 V , commonly up to ~80 V OCV Lower, but still dangerous — most welder shocks come from here

A dangerous misconception is that the secondary circuit is "safe." Secondary voltage can be lethal under the right conditions — wet skin, perspiration, damp clothing, or a confined metal space all drop body resistance and let current flow. Prevention measures (ANSI Z49.1 / OSHA 1910.252):

  • Never touch the electrode, wire, or live metal parts with bare skin or wet gloves
  • Keep the work and yourself dry; never stand or kneel in water while welding
  • Ground the workpiece and the equipment frame properly; inspect cables for bare spots or cracked insulation
  • Use fully insulated electrode holders and ensure the work clamp makes solid contact
  • In damp or confined locations, use equipment with reduced OCV or a voltage-reducing device (VRD)

Turn the machine off before changing electrodes or leaving the station; never coil the electrode cable around the body

Arc Radiation and Eye Protection

The welding arc emits ultraviolet (UV) , visible , and infrared (IR) radiation. UV causes arc eye (also called welder's flash or photokeratitis) — a painful, gritty, delayed inflammation of the cornea — plus skin burns like a severe sunburn. IR can cause retinal burns and cataracts over time. The defense is a welding helmet with a filter plate of the correct shade number , plus safety glasses with side shields worn underneath, and full skin coverage.

Selecting the Filter Lens Shade Number

The shade number scales with the brightness of the arc, which rises with arc current (amperage) and varies by process. Higher current = higher (darker) shade. The table below gives OSHA minimum protective shades and the darker ANSI/AWS suggested shades (Z49.1 Table 1). Always start with the suggested shade and lighten only enough to see the weld pool clearly.

  • Process Arc current (A) OSHA min. shade ANSI/AWS suggested
  • SMAW < 60 7 —
  • SMAW 60–160 8 10
  • SMAW 160–250 10 12
  • SMAW 250–550 11 14
  • GMAW/FCAW < 60 7 —
  • GMAW/FCAW 60–160 10 11
  • GMAW/FCAW 160–250 10 12
  • GMAW/FCAW 250–500 10 14
  • GTAW < 50 8 10
  • GTAW 50–150 8 12
  • GTAW 150–500 10 14
  • Plasma arc cutting (PAC) < 300 8 9
  • Plasma arc cutting (PAC) 300–400 9 12
  • Air carbon arc (CAC-A), light < 500 10 12
  • Air carbon arc (CAC-A), heavy 500–1000 11 14
  • Oxyfuel gas welding/cutting (torch, by thickness) 3–6 4–8

Exam trap: GTAW (TIG) produces more UV per ampere than SMAW, so it often needs a darker shade than its low current would suggest. And oxyfuel work needs only a shade 3–6 (a flame, not an arc), but it still needs eye protection.

Fumes and Gases

Welding fumes are fine metallic-oxide particulate formed when vaporized metal condenses; gases (carbon monoxide, ozone, nitrogen oxides, shielding-gas displacement) form separately. ANSI Z49.1 requires that breathing-zone concentrations stay below the applicable OSHA Permissible Exposure Limit (PEL) or ACGIH Threshold Limit Value (TLV). The first control is ventilation , not respirators: provide local exhaust ventilation (LEV) at the arc, or adequate general/mechanical ventilation, and use respiratory protection only when ventilation cannot reach the limits.

  • Fume/gas Source Health effect
  • Hexavalent chromium (Cr⁶⁺) Stainless steel, chromium alloys Lung cancer; very low PEL (5 µg/m³)
  • Manganese Most steel electrodes/wires Neurological damage (manganism)
  • Zinc oxide Galvanized (zinc-coated) steel Metal fume fever (flu-like)
  • Cadmium Plated/coated metals, some brazing alloys Acute lung injury, can be fatal
  • Lead Painted/coated steel Lead poisoning (CNS, kidney)
  • Ozone (O₃) UV acting on air, esp. GMAW/GTAW on aluminum Respiratory irritation, pulmonary edema
  • Carbon monoxide (CO) CO₂ shielding gas breakdown Asphyxiant; binds hemoglobin

Welders should keep their head out of the fume plume , position work so natural draft carries fumes away, and never weld on galvanized, cadmium-plated, or painted metal without dedicated ventilation. The exam loves the stainless-steel → hexavalent chromium and galvanized → zinc/metal-fume-fever pairings.

Fire and Explosion Prevention

Sparks and molten spatter can travel and ignite combustibles up to 35 ft (10 m) away — air carbon arc cutting throws sparks even farther. OSHA 1910.252 and NFPA 51B set the rules:

  • Clear combustibles within 35 ft ; if they cannot be moved, cover with fire-resistant blankets/guards
  • Keep a charged Class ABC fire extinguisher within reach
  • Issue a hot-work permit for any cutting/welding outside a designated, fire-safe welding area

Post a fire watch during the work and afterward — OSHA requires a minimum of 30 minutes after work stops; NFPA 51B (2019 and later) extends this to 60 minutes , with the area monitored for up to 3 additional hours where required

Never weld or cut on containers that held flammables until they are purged, cleaned, or inerted — explosion risk

Compressed-Gas Cylinder Safety

Oxyfuel and shielding-gas cylinders are high-pressure vessels (oxygen ~2,200 psi). ANSI Z49.1 and OSHA 1910.253 require:

  • Store and use cylinders upright and secured (chain/strap) to a fixed support; never let them tip or roll
  • Keep the valve protection cap on whenever the regulator is removed or the cylinder is moved/stored

Separate oxygen from fuel-gas cylinders and combustibles by at least 20 ft, or by a noncombustible barrier ≥5 ft high with a ≥½-hour fire rating when in storage

  • Never use oxygen as a substitute for compressed air (clothing/oil + oxygen = fire)
  • Keep cylinders, regulators, and fittings free of oil and grease , especially on oxygen service

Fit flashback arrestors and reverse-flow (backflow) check valves on both the oxygen and fuel-gas lines to stop a flame or gas from traveling back into the hose/cylinder

"Crack" a cylinder valve before attaching a regulator to blow out dirt, and open fuel-gas valves no more than ¾–1 turn so they can be shut quickly

PPE and Confined-Space Entry

PPE for welding includes the helmet with correct filter shade, safety glasses with side shields beneath it, flame-resistant (FR) clothing buttoned to the neck with no cuffs or open pockets, leather gloves and aprons/leathers as needed, and respiratory protection when ventilation is insufficient. 146: test the atmosphere in order oxygen first, then combustibles, then toxics . 5% is oxygen-enriched (a fire accelerant). Provide forced ventilation, an entry permit, a trained attendant stationed outside , and a rescue plan.

Cylinders are never taken into a confined space , and shielding gases must not be left running inside (they displace oxygen).

  • Hazard Key threshold/rule Primary control
  • Electric shock Primary 230–575 V; OCV up to ~80 V Insulate, ground, keep dry, VRD
  • Arc radiation Shade scales with amperage Correct-shade helmet, FR coverage
  • Fumes/gases Stay below PEL/TLV (Cr⁶⁺ 5 µg/m³) Local exhaust ventilation
  • Fire/explosion 35 ft clearance; 30/60-min fire watch Hot-work permit, extinguisher
  • Compressed gas O₂/fuel ≥20 ft apart in storage Secure upright, caps, flashback arrestors
  • Confined space O₂ 19.5%–23.5% Test, ventilate, permit, attendant