Study guide

8.3 Synchro Troubleshooting, Wiring Faults & Maintenance

EASA Part-66 Module 04 — Electronic Fundamentals Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Semiconductor Physics & Diode Fundamentals

1.1 Semiconductor Theory, PN Junction & Conduction 1.2 Power Rectification & Filtering Circuits 1.3 Diode Wave-Shaping & Voltage Multipliers

2 Chapter 2: Special-Purpose Diodes & Semiconductor Testing

2.1 Voltage Regulation & Zener Diodes 2.2 Optoelectronic, Fast-Switching & Power Diodes 2.3 Diode Testing, Failure Modes & Aircraft Applications

3 Chapter 3: Transistor Principles, Configurations & Biasing

3.1 BJT Structure, Operation & Current Relationships 3.2 Transistor Circuit Configurations 3.3 Transistor Biasing, Thermal Stability & Testing

4 Chapter 4: Transistor Amplifiers, FETs & Oscillators

4.1 Amplifier Operating Classes & Push-Pull Systems 4.2 Multistage Coupling & Negative Feedback 4.3 Field Effect Transistors & Darlington Pairs 4.4 Oscillators & Multivibrators

5 Chapter 5: Operational Amplifiers & Linear Integrated Circuits

5.1 Op-Amp Fundamentals, Characteristics & Virtual Ground 5.2 Op-Amp Linear Circuits & Calculations 5.3 Active Wave-Shaping, Comparators & Digital Logic Basics

6 Chapter 6: Printed Circuit Boards & Electrostatic Discharge Protection

6.1 PCB Design, Layered Construction & Manufacturing 6.2 PCB Inspection, Soldering Defects & Electrostatic Discharge (ESD) Control

7 Chapter 7: Servomechanism Principles, Transducers & Control

7.1 Open-Loop and Closed-Loop Control Architecture 7.2 Servomechanism Transducers (Potentiometers, LVDTs & RVDTs) 7.3 Servo Dynamics, Damping, Motors & Hunting Prevention

8 Chapter 8: Synchro Systems, Resolvers & Fault Diagnosis

8.1 Torque Synchro Systems (TX, TR & Differentials) 8.2 Control Synchros, Resolvers & Inductive Sensors 8.3 Synchro Troubleshooting, Wiring Faults & Maintenance

8.3 Synchro Troubleshooting, Wiring Faults & Maintenance

Key Takeaways Explain This Topic AI

Reversing two stator leads (e.g. S1 and S3) reverses receiver rotational direction, whereas reversing rotor excitation leads (R1 and R2) introduces a constant 180° angular offset error across the entire dial.

An open rotor circuit on a transmitter drops all stator line-to-line voltages to zero, leaving the receiver with zero torque; an open stator line causes the receiver to align to two false nulls 180° apart with sluggish torque and audible 400 Hz acoustic hum.

Standardized electrical zeroing is mandatory across all aircraft Line Replaceable Units (LRUs) and indicators to guarantee interchangeability without re-rigging airframe mechanical linkages.

The Voltmeter Null Method resolves the 180° ambiguity first by jumpering S1-S3 and R1-S2 and reading R2 to the S1-S3 junction (about 37 V at true zero versus 193 V at 180° on a 115 V synchro), then rotates the casing for a true S1-S3 null of ≤ 30 mV.

Routine maintenance requires verifying 400 Hz bus power quality (voltage, frequency, harmonic distortion) and performing high-voltage DC insulation tests (> 20 MΩ at 500 V DC) with electronic servo amplifiers safely disconnected.

Last updated: September 2026

8.3 Synchro Troubleshooting, Wiring Faults & Maintenance

Aircraft maintenance engineers (AMEs) holding an EASA Part-66 Category B2 avionic license must be proficient in isolating faults within aircraft synchro and resolver loops. Because synchros are electromechanical devices distributed across extensive wiring harnesses—connecting flight control surfaces, engine nacelles, and landing gear bays to flight deck indicators and flight management computers—wiring errors, harness chafing, and connector pin corrosion are common. Understanding the electromagnetic consequences of open circuits, short circuits, and reversed connections allows rapid fault isolation to the Line Replaceable Unit (LRU) or wiring harness.

Systematic Troubleshooting: Wiring Fault Symptoms

When a synchro system malfunctions following maintenance, harness modification, or component replacement, the physical behavior of the receiver indicator immediately pinpoints the nature of the fault:

Loading diagram...

1. Stator Lead Reversal (e.g., Swapping S1 and S3)

Electromagnetic Mechanism: Swapping two stator leads inverts the physical phase sequence of the stator magnetic field vector in space. For example, if stator lines S1 and S3 are transposed, a clockwise rotation of the transmitter shaft causes the resultant magnetic field vector in the receiver to rotate counter-clockwise.

Observable Symptoms:

The receiver indicator rotates in the reverse direction relative to the transmitter (clockwise TX rotation produces counter-clockwise TR movement).

At electrical zero ( 0 ∘ 0^\circ 0 ∘ ), the indicator reads correctly ( 0 ∘ 0^\circ 0 ∘ ). However, at an input of 030 ∘ 030^\circ 03 0 ∘ , the indicator reads 330 ∘ 330^\circ 33 0 ∘ ( 360 ∘ − 30 ∘ 360^\circ - 30^\circ 36 0 ∘ − 3 0 ∘ ); at an input of 090 ∘ 090^\circ 09 0 ∘ , it reads 270 ∘ 270^\circ 27 0 ∘ .

Positioning torque remains strong and normal.

2. Rotor Lead Reversal (Swapping R1 and R2)

Electromagnetic Mechanism: Swapping rotor excitation leads R1 and R2 on either the transmitter or receiver reverses the phase of the rotor magnetic flux by exactly 180 ∘ 180^\circ 18 0 ∘ ( sin ⁡ ( ω t + 180 ∘ ) = − sin ⁡ ( ω t ) \sin(\omega t + 180^\circ) = -\sin(\omega t) sin ( ω t + 18 0 ∘ ) = − sin ( ω t ) ). The north and south magnetic poles of the rotor are inverted.

Observable Symptoms:

The receiver rotates in the correct direction (clockwise TX rotation produces clockwise TR rotation).

The indicator exhibits a constant 180 ∘ 180^\circ 18 0 ∘ angular offset error across all angles: when TX is at 000 ∘ 000^\circ 00 0 ∘ , TR indicates 180 ∘ 180^\circ 18 0 ∘ ; when TX is at 090 ∘ 090^\circ 09 0 ∘ , TR indicates 270 ∘ 270^\circ 27 0 ∘ .

Positioning torque remains strong and normal.

3. Swapping Stator and Rotor Connections

Electromagnetic Hazard: An inadvertent wiring error where 115 V AC 115\text{ V AC} 115 V AC reference power is wired directly to stator leads (e.g., excitation connected across S1-S2) while R1-R2 are wired into the stator lines.

Observable Symptoms: Catastrophic failure. Stator windings have lower design voltage and lower impedance than primary rotor windings. Heavy current draws occur, accompanied by severe magnetic saturation, intense acoustic hum, rapid overheating, melted varnish insulation, and blown bus circuit breakers.

4. Open-Circuit Faults

Open Rotor Circuit on Transmitter (TX):

Mechanism: Loss of excitation power to TX rotor winding (broken lead, blown fuse, or worn slip-ring brush).

Symptom: The TX generates zero magnetic flux. All stator voltages ( V S 1 − S 2 V_{S1-S2} V S 1 − S 2 ​ , V S 2 − S 3 V_{S2-S3} V S 2 − S 3 ​ , V S 3 − S 1 V_{S3-S1} V S 3 − S 1 ​ ) drop to 0.00 V 0.00\text{ V} 0.00 V . The TR rotor remains energized from the AC reference bus, but with zero stator field, no aligning torque is developed. The TR pointer floats freely and wanders when subjected to airframe vibration.

Open Rotor Circuit on Receiver (TR):

Mechanism: Broken R1 or R2 lead to the TR rotor.

Symptom: The TX operates normally and generates healthy stator voltages. However, because the TR rotor winding carries zero current, no Lorentz aligning torque ( F = I L × B F = I L \times B F = I L × B ) develops. The TR shaft produces no torque. It may drift aimlessly or, under certain stator flux conditions, begin spinning slowly as an induction motor due to eddy currents induced in its damper flywheel.

Open Stator Lead (e.g., S2 Open):

Mechanism: One of the three interconnecting stator wires breaks or develops high connector pin resistance.

Symptom: The stator field collapses from a two-dimensional rotating vector into a single-phase stationary pulsating magnetic axis between the remaining two operational lines (S1 and S3). The receiver exhibits:

Two false null positions 180 ∘ 180^\circ 18 0 ∘ apart (bimodal lock-in).

Severely degraded torque —the pointer moves sluggishly and exhibits weak positioning power.

Loud, audible 400 Hz 400\text{ Hz} 400 Hz acoustic buzz/hum and stator coil heating caused by heavy unbalanced circulating currents.

Tendency of the pointer to stick or stall when moving through angles perpendicular to the active axis.

5. Short-Circuit Stator Faults

Mechanism: Insulation breakdown or harness pinch short-circuiting two stator leads together (e.g., S1 shorted to S2).

Symptom: The shorted stator pair acts as a heavily loaded transformer secondary. Massive circulating currents flow from the TX. The receiver indicator locks rigidly at a fixed false angle and resists manual turning. Both units emit a loud 400 Hz 400\text{ Hz} 400 Hz vibration hum, overheat rapidly, and risk thermal coil destruction if not quickly isolated.

  • Fault Condition Indicator Direction Indicator Position Error Operating Torque Acoustic / Thermal Symptoms
  • Normal Operation Correct 0 ∘ 0^\circ 0 ∘ (Synchronized) Full Rated Torque Quiet; Normal ambient temperature

Stator Leads Swapped (S1-S3) Reversed Mirrored ( 360 ∘ − θ 360^\circ - \theta 36 0 ∘ − θ ) Full Rated Torque Quiet; Normal temperature

Rotor Leads Swapped (R1-R2) Correct Constant 180 ∘ 180^\circ 18 0 ∘ Error Full Rated Torque Quiet; Normal temperature

  • Open TX Rotor (R1 or R2) None Wanders / Floats Freely Zero Torque Completely silent; Cold
  • Open TR Rotor (R1 or R2) None Wanders / May Drift Zero Torque TR stator may warm slightly

Open One Stator Lead (S2) Sluggish / Sticks Two False Nulls ( 180 ∘ 180^\circ 18 0 ∘ ) Weak / Spongy Torque Loud 400 Hz buzz ; Units run hot

Shorted Stator Lines (S1-S2) Locked Locked at Fixed False Angle Resists Movement Severe 400 Hz hum ; Rapid overheating

Electrical Zeroing Procedures

When installing a replacement synchro transmitter (TX/CX) or receiver (TR/CT) on an aircraft, the unit must be precisely aligned to Standard Electrical Zero . Standard electrical zero defines an unambiguous electromechanical baseline where the rotor shaft angle is mechanically at 0 ∘ 0^\circ 0 ∘ and its electromagnetic field satisfies exact phase and voltage criteria.

Operational Importance

If replacement synchros were installed without electrical zero alignment, every LRU replacement would require tedious mechanical re-rigging of flight control cables, pushrods, and cockpit dial faces. Standard electrical zero ensures true Line Replaceable Unit (LRU) interchangeability : any zeroed transmitter will interface accurately with any zeroed receiver or flight control computer.

The Voltmeter Null Method (Step-by-Step for TX / CX)

The Voltmeter Null Method is the universal standard for precision zero alignment on the aircraft maintenance bench and flight line:

Loading diagram...

Mechanical Pre-alignment:

Mechanically secure the primary aircraft mechanism (e.g., rudder, aileron, or flap drive) in its rigged neutral baseline position.

Loosen the synchro casing mounting clamps and rotate the rotor shaft until the pointer or dial index aligns approximately with the 0 ∘ 0^\circ 0 ∘ mark.

Coarse Zero Setup (Eliminating the 180 ∘ 180^\circ 18 0 ∘ Ambiguity):

The S3-S1 terminal pair nulls at two rotor positions: 0 ∘ 0^\circ 0 ∘ (true electrical zero) and 180 ∘ 180^\circ 18 0 ∘ (false zero). A plain AC voltmeter across S1-S3 cannot tell them apart, so a coarse check that puts the rotor voltage into the measurement loop is performed first.

Connect a temporary jumper between stator terminals S1 and S3 , and a second jumper from rotor terminal R1 to stator terminal S2 . This places the rotor excitation voltage in series with the stator voltage.

Connect an AC electronic voltmeter (True RMS, 400 Hz 400\text{ Hz} 400 Hz ) between rotor terminal R2 and the common S1-S3 junction , starting on a 0 − 250 V 0-250\text{ V} 0 − 250 V range.

Apply rated excitation ( 115 V 115\text{ V} 115 V or 26 V AC 26\text{ V AC} 26 V AC ) to rotor terminals R1 and R2.

Rotate the synchro casing slowly for the lowest reading. At true electrical zero the rotor and stator voltages oppose , so the meter reads their difference: approximately 37 V 37\text{ V} 37 V on a 115 V 115\text{ V} 115 V synchro (about 15 V 15\text{ V} 15 V on a 26 V 26\text{ V} 26 V instrument synchro). At the 180 ∘ 180^\circ 18 0 ∘ false zero the two voltages add , and the meter reads approximately 193 V 193\text{ V} 193 V . If you obtain the high reading, rotate the shaft half a revolution and repeat.

Fine Zero Adjustment (Precision Null):

Remove both coarse-check jumpers (S1-S3 and R1-S2), leaving only the rated excitation on R1 and R2.

Connect the sensitive AC voltmeter directly between stator terminals S1 and S3 .

Carefully rotate the synchro casing in minute increments until the voltmeter indicates the absolute minimum voltage .

In an airworthy synchro, this minimum residual null voltage must not exceed 30 mV 30\text{ mV} 30 mV ( 0.030 V AC RMS 0.030\text{ V AC RMS} 0.030 V AC RMS ). Residual voltage consists of harmonic distortion and quadrature noise.

Directional Verification:

With the jumpers still removed, rotate the synchro rotor shaft slightly in the clockwise (increasing-angle) direction ( + 5 ∘ +5^\circ + 5 ∘ ).

Because V S 3 − S 1 = V m a x sin ⁡ θ V_{S3-S1} = V_{max} \sin \theta V S 3 − S 1 ​ = V ma x ​ sin θ , the S3-S1 voltage must rise smoothly away from null in phase with the R1-R2 reference (roughly 0.087 × V m a x ≈ 7.8 V 0.087 \times V_{max} \approx 7.8\text{ V} 0.087 × V ma x ​ ≈ 7.8 V at 5 ∘ 5^\circ 5 ∘ on a 90 V 90\text{ V} 90 V synchro).

A reading that rises 180 ∘ 180^\circ 18 0 ∘ out of phase with the reference means the unit was set on the false 180 ∘ 180^\circ 18 0 ∘ null; rotate the casing half a revolution and repeat the fine null.

Mounting Clamp Torquing:

Secure the synchro casing by tightening the mounting clamp screws in an alternating, cross-diagonal sequence to specified torque limits.

Re-check the voltmeter reading between S1 and S3 during and after torquing to ensure mechanical clamping forces did not twist the casing out of null alignment.

Note

Why Residual Null Voltage is Never Zero: An apprentice technician might expect a perfect null voltage of 0.000 V 0.000\text{ V} 0.000 V . In physical synchros, the residual null voltage at electrical zero is typically between 10 mV 10\text{ mV} 10 mV and 30 mV 30\text{ mV} 30 mV . This residual consists of quadrature voltage (a small component shifted 90 ∘ 90^\circ 9 0 ∘ in time-phase from the fundamental reference caused by winding resistance and inter-winding capacitance) and third-harmonic distortion ( 1200 Hz 1200\text{ Hz} 1200 Hz components generated by non-linear core magnetic permeability). Precision servo amplifiers incorporate phase-sensitive demodulators that reject this quadrature and harmonic residual.

400 Hz Aircraft AC Power Quality & Maintenance Testing

Reliable synchro operation depends directly on the electrical integrity of the aircraft 400 Hz 400\text{ Hz} 400 Hz alternating current power bus and wiring harness insulation:

1. AC Power Quality Checks (MIL-STD-704 & RTCA DO-160)

Voltage Amplitude: Measure nominal bus voltage under load: 115 V ± 5 V AC RMS 115\text{ V} \pm 5\text{ V AC RMS} 115 V ± 5 V AC RMS (or 26 V ± 1.0 V AC RMS 26\text{ V} \pm 1.0\text{ V AC RMS} 26 V ± 1.0 V AC RMS ). Under-voltage reduces aligning torque ( T ∝ V r e f 2 T \propto V_{ref}^2 T ∝ V re f 2 ​ ); over-voltage accelerates core heating and insulation degradation.

Frequency Stability: Verify bus frequency with a digital frequency counter: 400 Hz ± 5 Hz 400\text{ Hz} \pm 5\text{ Hz} 400 Hz ± 5 Hz ( 395 Hz to 405 Hz 395\text{ Hz to } 405\text{ Hz} 395 Hz to 405 Hz ). Frequency drift directly shifts winding inductive reactance ( X L = 2 π f L X_L = 2\pi f L X L ​ = 2 π f L ). If frequency falls significantly, stator reactance decreases, causing excessive excitation current and thermal tripping.

Total Harmonic Distortion (THD): Maximum permissible harmonic distortion must remain < 5 % < 5\% < 5% . Excessive harmonics distort the stator field shape, shifting the apparent electrical null and causing angular tracking errors.

2. Insulation Resistance (Megohmmeter / Megger) Testing

Moisture ingress, hydraulic fluid contamination, and aging wire harness insulation can create high-resistance leakage paths to airframe ground. When troubleshooting intermittent synchro errors, perform insulation resistance testing using a calibrated 500 V DC 500\text{ V DC} 500 V DC Megohmmeter :

Stator-to-Chassis Insulation: Connect all three stator terminals (S1, S2, S3) together; apply 500 V DC 500\text{ V DC} 500 V DC between the shorted stator leads and airframe chassis ground. Measured resistance must exceed 20 M Ω 20\text{ M}\Omega 20 M Ω .

Rotor-to-Chassis Insulation: Connect rotor terminals (R1, R2) together; apply 500 V DC 500\text{ V DC} 500 V DC to chassis ground. Measured resistance must exceed 20 M Ω 20\text{ M}\Omega 20 M Ω .

Stator-to-Rotor Insulation: Apply 500 V DC 500\text{ V DC} 500 V DC between the shorted stator group and the shorted rotor group. Measured resistance must exceed 20 M Ω 20\text{ M}\Omega 20 M Ω .

Warning

Mandatory Megger Disconnection Precaution: Before applying 500 V DC 500\text{ V DC} 500 V DC Megohmmeter test voltages to any synchro harness, technicians must physically disconnect all electronic LRUs, solid-state servo amplifiers, and digital flight computer cards connected to the circuit. Applying high-voltage DC into solid-state electronic modules will instantly puncture semiconductor gate oxides and destroy input driver stages.

  • Worked Engineering Calculations
  • Calculation 1: Total RMS Residual Null Voltage at Electrical Zero

During bench overhaul of a Size 15 synchro transmitter, an avionics technician measures the residual voltage components between stator terminals S1 and S3 at the precision mechanical zero position using a selective spectrum analyzer:

Fundamental in-phase null voltage: V i n − p h a s e = 0.0 mV V_{in-phase} = 0.0\text{ mV} V in − p ha se ​ = 0.0 mV (perfect alignment)

Fundamental quadrature ( 90 ∘ 90^\circ 9 0 ∘ phase-shifted) component: V q u a d = 19.2 mV RMS V_{quad} = 19.2\text{ mV RMS} V q u a d ​ = 19.2 mV RMS

Third-harmonic ( 1200 Hz 1200\text{ Hz} 1200 Hz ) distortion component: V 3 r d = 14.4 mV RMS V_{3rd} = 14.4\text{ mV RMS} V 3 r d ​ = 14.4 mV RMS

  • Stray high-frequency noise: V n o i s e = 4.0 mV RMS V_{noise} = 4.0\text{ mV RMS} V n o i se ​ = 4.0 mV RMS
  • Step 1: Compute Total RMS Residual Null Voltage ( V n u l l V_{null} V n u ll ​ )

Because these voltage components are orthogonal in phase or frequency, their root-mean-square combination is given by: V n u l l = V q u a d 2 + V 3 r d 2 + V n o i s e 2 V_{null} = \sqrt{V_{quad}^2 + V_{3rd}^2 + V_{noise}^2} V n u ll ​ = V q u a d 2 ​ + V 3 r d 2 ​ + V n o i se 2 ​ ​ V n u l l = ( 19.2 ) 2 + ( 14.4 ) 2 + ( 4.0 ) 2 = 368.64 + 207.36 + 16.00 = 592.00 = 24.33 mV RMS V_{null} = \sqrt{(19.2)^2 + (14.4)^2 + (4.0)^2} = \sqrt{368.64 + 207.36 + 16.00} = \sqrt{592.00} = 24.33\text{ mV RMS} V n u ll ​ = ( 19.2 ) 2 + ( 14.4 ) 2 + ( 4.0 ) 2 ​ = 368.64 + 207.36 + 16.00 ​ = 592.00 ​ = 24.33 mV RMS

Step 2: Compare against airworthiness limits

The maximum allowable residual null voltage for this unit per the Component Maintenance Manual (CMM) is 30.0 mV RMS 30.0\text{ mV RMS} 30.0 mV RMS . Conclusion: Because 24.33 mV ≤ 30.0 mV 24.33\text{ mV} \le 30.0\text{ mV} 24.33 mV ≤ 30.0 mV , the synchro satisfies airworthiness criteria for electrical zero residual noise.

Calculation 2: Inductive Reactance & Current Shift with Frequency

A 115 V AC 115\text{ V AC} 115 V AC torque transmitter rotor winding has an internal resistance of R = 45.0 Ω R = 45.0\ \Omega R = 45.0 Ω and an inductance of L = 0.120 H L = 0.120\text{ H} L = 0.120 H . Compare the rotor impedance and excitation current under:

Rated aircraft power ( f 1 = 400 Hz f_1 = 400\text{ Hz} f 1 ​ = 400 Hz )

A severely degraded ground power cart operating at an off-frequency of f 2 = 320 Hz f_2 = 320\text{ Hz} f 2 ​ = 320 Hz

Case A: Rated Frequency ( 400 Hz 400\text{ Hz} 400 Hz ) X L 1 = 2 π f 1 L = 2 × 3.1416 × 400 Hz × 0.120 H = 301.59 Ω X_{L1} = 2\pi f_1 L = 2 \times 3.1416 \times 400\text{ Hz} \times 0.120\text{ H} = 301.59\ \Omega X L 1 ​ = 2 π f 1 ​ L = 2 × 3.1416 × 400 Hz × 0.120 H = 301.59 Ω Z 1 = R 2 + X L 1 2 = ( 45.0 ) 2 + ( 301.59 ) 2 = 2025 + 90956.5 = 92981.5 = 304.93 Ω Z_1 = \sqrt{R^2 + X_{L1}^2} = \sqrt{(45.0)^2 + (301.59)^2} = \sqrt{2025 + 90956.5} = \sqrt{92981.5} = 304.93\ \Omega Z 1 ​ = R 2 + X L 1 2 ​ ​ = ( 45.0 ) 2 + ( 301.59 ) 2 ​ = 2025 + 90956.5 ​ = 92981.5 ​ = 304.93 Ω I 1 = V r e f Z 1 = 115 V 304.93 Ω = 0.3771 A = 377.1 mA I_1 = \frac{V_{ref}}{Z_1} = \frac{115\text{ V}}{304.93\ \Omega} = 0.3771\text{ A} = 377.1\text{ mA} I 1 ​ = Z 1 ​ V re f ​ ​ = 304.93 Ω 115 V ​ = 0.3771 A = 377.1 mA

Case B: Degraded Frequency ( 320 Hz 320\text{ Hz} 320 Hz ) X L 2 = 2 π f 2 L = 2 × 3.1416 × 320 Hz × 0.120 H = 241.27 Ω X_{L2} = 2\pi f_2 L = 2 \times 3.1416 \times 320\text{ Hz} \times 0.120\text{ H} = 241.27\ \Omega X L 2 ​ = 2 π f 2 ​ L = 2 × 3.1416 × 320 Hz × 0.120 H = 241.27 Ω Z 2 = ( 45.0 ) 2 + ( 241.27 ) 2 = 2025 + 58211.2 = 60236.2 = 245.43 Ω Z_2 = \sqrt{(45.0)^2 + (241.27)^2} = \sqrt{2025 + 58211.2} = \sqrt{60236.2} = 245.43\ \Omega Z 2 ​ = ( 45.0 ) 2 + ( 241.27 ) 2 ​ = 2025 + 58211.2 ​ = 60236.2 ​ = 245.43 Ω I 2 = V r e f Z 2 = 115 V 245.43 Ω = 0.4686 A = 468.6 mA I_2 = \frac{V_{ref}}{Z_2} = \frac{115\text{ V}}{245.43\ \Omega} = 0.4686\text{ A} = 468.6\text{ mA} I 2 ​ = Z 2 ​ V re f ​ ​ = 245.43 Ω 115 V ​ = 0.4686 A = 468.6 mA

Step 3: Compute current increase Δ I = 468.6 − 377.1 377.1 × 100 % = 91.5 377.1 × 100 % = + 24.27 % \Delta I = \frac{468.6 - 377.1}{377.1} \times 100\% = \frac{91.5}{377.1} \times 100\% = +24.27\% Δ I = 377.1 468.6 − 377.1 ​ × 100% = 377.1 91.5 ​ × 100% = + 24.27%

Maintenance Significance: Operating the aircraft synchro bus at 320 Hz 320\text{ Hz} 320 Hz increases rotor excitation current by more than 24 % 24\% 24% , causing excessive I 2 R I^2 R I 2 R copper heating and risking insulation breakdown during extended ground checks.

Loading diagram... Voltmeter Null Method for Transmitter Electrical Zero Alignment