Study guide
9.2 Flexible Hoses, Installation Geometry & Serviceability
EASA Part-66 Module 07 — Maintenance Practices Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Safety Precautions — Electricity, Gases & Chemical Hazards
1.1 Electrical-System Hazards, Isolation & Protective Equipment 1.2 Compressed Gases, Pressure Vessels & Oxygen System Safety 1.3 Hazardous Chemicals, Solvents, Oils & Personal Protective Equipment
2 Chapter 2: Safety Precautions — Fire Protection, Confined Spaces & Emergency Response
2.1 Fire Classifications, Extinguishing Agents & Asphyxiation Risks 2.2 Confined-Space Entry, Fuel-Tank Safety & CDCCL Control 2.3 Emergency Response, Accident Remediation & Ballistic Recovery Systems
3 Chapter 3: Workshop Practices, Hand Tools & Precision Measurement
3.1 Workshop Housekeeping, Tool Control & Foreign Object Debris (FOD) 3.2 Engineering Dimensions, Allowances & Tolerances 3.3 Hand Tools, Powered Equipment & Operating Safety 3.4 Precision Measuring Instruments & Standards Traceability
4 Chapter 4: Fastener Torquing & Avionic Test Equipment
4.1 Torque Wrenches, Extension Calculations & Calibration Care 4.2 Multimeters, Megohmmeters & Insulation Testing 4.3 Bonding Testers, Milliohmmeters & Oscilloscopes
5 Chapter 5: Engineering Drawings, Standards & Fits
5.1 Orthographic Projections, Title Blocks & Revision Control 5.2 Drawing Line Conventions, Symbols & ATA Specification 100/iSpec 2200 5.3 Electrical Schematics, Wiring Interconnects & Component Location 5.4 Systems of Limits, Fits, Clearances & Shaft Alignment
6 Chapter 6: Electrical Wiring Interconnection System (EWIS)
6.1 EWIS Principles, Wire Types & Loom Routing Practices 6.2 Crimp Terminations, Connector Pin Insertion & Extraction Tooling 6.3 Electrical Bonding, Grounding Resistance & Electromagnetic Shielding
7 Chapter 7: Aircraft Riveting Practice
7.1 Solid and Blind Rivet Classifications, Materials & Head Markings 7.2 Rivet Spacing, Pitch, Edge Distance & Structural Layout 7.3 Countersinking, Dimpling Techniques & Rivet Installation 7.4 Rivet Joint Inspection, Failure Modes & Drill-Out Procedures
8 Chapter 8: Sheet Metal Working & Composite Materials
8.1 Sheet Metal Forming, Neutral Axis & Bend Allowance Calculations 8.2 Welding, Brazing, Soldering & Structural Adhesive Bonding 8.3 Composite Reinforcements, Pre-Preg Cold Storage & Clean Room Practice 8.4 Additive Manufacturing in Aircraft Maintenance
9 Chapter 9: Pipes, Flexible Hoses & Springs
9.1 Aircraft Rigid Tubing, Bending & 37-Degree Flaring Standards 9.2 Flexible Hoses, Installation Geometry & Serviceability 9.3 Aircraft Springs: Classifications, Rate Testing & Inspection
10 Chapter 10: Bearings & Mechanical Transmissions
10.1 Bearing Classifications, Load Types & Lubrication Practice 10.2 Bearing Defect Analysis: Spalling, Brinelling & Overheating 10.3 Gears, Gearboxes, Backlash Measurement & Belt/Chain Drives
11 Chapter 11: Flight Control Cables & Rigging
11.1 Aircraft Cable Construction, Sizing & Swaged Terminal Fittings 11.2 Cable Rigging, Turnbuckles & Temperature-Compensated Tensioning 11.3 Pulleys, Fairleads, Cable Inspection & Broken Strand Limits
12 Chapter 12: Aircraft Weight and Balance
12.1 Datum, Arm, Moment & Center of Gravity Principles 12.2 Aircraft Weighing Preparation, Equipment & Tare Deduction 12.3 Center of Gravity Calculations, Flight Limits & Ballast Adjustments
13 Chapter 13: Aircraft Handling, Storage & Winter Operations
13.1 Towing, Taxiing Protocols, Shear Pins & Wing Walkers 13.2 Jacking with Locking Collars, Chocking & Severe Weather Mooring 13.3 Ground De-icing and Anti-icing: Fluids, Clean Aircraft Concept & Holdover Times 13.4 Aircraft Parking, Protective Covers & Engine/Airframe Long-Term Preservation
14 Chapter 14: Inspection, Defect Assessment, Maintenance Procedures & Documentation
14.1 NDT Methods: Liquid Penetrant, Magnetic Particle, Eddy Current, Ultrasonic & Radiography 14.2 Corrosion Classifications, Mechanical Removal & Chemical Surface Treatments 14.3 Inspections After Lightning, Heavy Landing & Other Abnormal Events 14.4 Controlled Disassembly, Inspection & Reassembly 14.5 Troubleshooting, Defect Assessment & Repair Control 14.6 Maintenance Documentation, Work Reports & Shift Handover 14.7 Maintenance Planning, Stores Control, CRS & Occurrence Reporting
9.2 Flexible Hoses, Installation Geometry & Serviceability
Key Takeaways Explain This Topic AI
Hose identity, material, pressure rating, temperature range, fluid compatibility, life control, and fittings must match approved data.
A flexible hose needs enough freedom for specified motion and pressure effects without twist, chafe, kink, collapse, or excessive slack.
The lay line is a useful twist indicator, but the installation is accepted against the maintenance-data geometry and inspection criteria.
PTFE hose is not automatically unlimited-life; calendar, cycle, condition, and storage limits are controlled by the applicable programme and part data.
Proof or pressure testing uses the specified medium, pressure, duration, temperature, and safety enclosure.
Last updated: September 2026
9.2 Flexible Hoses, Installation Geometry & Serviceability
Flexible hoses accommodate relative movement, vibration, installation tolerance, and connections that rigid tubing cannot serve safely. Flexibility does not make routing arbitrary. A hose can fail through pressure, temperature, chemical incompatibility, ageing, twist, minimum-bend-radius violation, abrasion, fire exposure, bad fitting assembly, or movement beyond its designed envelope.
Identification and selection
Use the exact part number or an approved equivalent. Verify the hose construction, size, pressure class, temperature range, fluid compatibility, electrical or fire-protection features, and end fittings against current data. External similarity is not proof of interchangeability. A replacement also needs the correct release documentation, storage history, and life status.
Elastomeric, thermoplastic, metal, and PTFE-lined hoses behave differently. Some assemblies have calendar or installation lives; others are controlled by condition, cycles, or a maintenance programme. PTFE resists many fluids and temperatures, but the complete assembly can still be limited by braid damage, fitting condition, liner degradation, fire sleeve, storage, contamination, or the approved programme. PTFE therefore does not mean unlimited life.
Routing and motion
First place the end fittings in natural alignment. Do not use the hose as a torsion spring to force a fitting into position. A continuous lay line makes twist easier to see, but acceptance is based on the approved installation. Respect the specified minimum bend radius; a tighter bend can flatten the bore, overstress reinforcement, and concentrate strain near a fitting.
Slack is task-specific. Too little can place tension on fittings or prevent full travel. Too much can whip, chafe, trap fluid, foul controls, or contact heat. The required allowance depends on length, pressure change, temperature, component movement, and hose construction. Generic percentage rules are training illustrations, not universal acceptance criteria.
Route away from exhausts, hot air, electrical arcing, sharp edges, moving controls, and areas where leaked fluid would create a hazard. Use the specified clamps, stand-offs, sleeves, grommets, and fire protection. A clamp should support the assembly without crushing it. Check the complete movement envelope, including landing-gear travel, engine movement, steering, flight-control travel, and maintenance access where applicable.
Inspection
Clean sufficiently to inspect without driving contamination into the system. Look for wetness, staining, blisters, soft or hardened areas, cracking, exposed or broken braid, flattening, kinks, pulled fittings, corrosion, damaged fire sleeve, chafe, and heat effects. Check security and evidence of relative movement at clamps and fittings. The maintenance data determine allowable condition and disposition; do not repair a pressure hose with tape, an improvised sleeve, or an unauthorised fitting adjustment.
A leak is not always at the point where fluid appears. Clean, dry, operate or pressurise only as authorised, and trace the source while respecting fluid-injection hazards. Never use a hand to search for a high-pressure pinhole leak.
Assembly and testing
Hose fabrication is performed only with approved materials, tooling, instructions, and authorisation. Cleanliness caps, cut quality, fitting insertion, crimp dimensions, angular alignment, and identification are controlled. Proof testing or leakage testing uses the specified fluid or gas, pressure, ramp rate, hold time, temperature, and acceptance criteria. The assembly is restrained or enclosed because stored pressure can release violently. Oxygen-system hose preparation has additional cleanliness controls.
After installation, remove protective caps at the latest practical point, prevent contamination, torque fittings by the specified method, fit locking devices, restore clamps and guards, and perform required leak and functional checks. Record part identity and life data as required.
The reliable exam answer is the data-led one: avoid twist, respect the stated bend radius, provide only the movement allowance specified, protect against chafe and heat, and apply the component’s actual life and test requirements.
Worked installation check
Suppose a replacement hose connects a pump on a vibration-mounted assembly to a fixed bulkhead union. Before tightening, confirm that both fittings line up naturally and that the hose part number and fire protection match the illustrated parts data. Position the hose so the lay line is not spiralled. Move the supported assembly through the range required by the task and observe the hose near each end fitting, clamp, adjacent structure, and heat source. The hose must not become taut, fold, rub, or drive a side load into the union. Install clamps in the stated positions and confirm they support rather than flatten the hose.
After torquing and locking the fittings by approved data, restore the system and carry out the specified leakage and functional test. A stain that reappears after cleaning is investigated at its true source; tightening a fitting beyond its prescribed value is not a safe response. Reinspect the hose under operating pressure and after movement if required, because pressure can change length or stiffness. Finally record identity and life information and confirm that no cap, plug, tool, or cleaning material remains in the system. This sequence tests configuration, motion, security, and leakage rather than relying on appearance at one static position.
Installation Inspection Matrix
- Check Look for
- Identity Correct part, fittings, fluid compatibility, pressure and temperature capability
- Geometry Natural fitting alignment, specified bend radius and motion allowance, no twist
- Protection Correct clamps, sleeves, fire protection and clearance from heat, edges and moving parts
- Condition No chafe, kinks, blisters, exposed braid, leakage, corrosion or fitting movement
- Proof Required torque, locking, leak or pressure test, full movement check and records complete