1 Chapter 1: Safety Precautions — Electricity, Gases & Chemical Hazards
1.1 Electrical-System Hazards, Isolation & Protective Equipment 1.2 Compressed Gases, Pressure Vessels & Oxygen System Safety 1.3 Hazardous Chemicals, Solvents, Oils & Personal Protective Equipment
2 Chapter 2: Safety Precautions — Fire Protection, Confined Spaces & Emergency Response
2.1 Fire Classifications, Extinguishing Agents & Asphyxiation Risks 2.2 Confined-Space Entry, Fuel-Tank Safety & CDCCL Control 2.3 Emergency Response, Accident Remediation & Ballistic Recovery Systems
3 Chapter 3: Workshop Practices, Hand Tools & Precision Measurement
3.1 Workshop Housekeeping, Tool Control & Foreign Object Debris (FOD) 3.2 Engineering Dimensions, Allowances & Tolerances 3.3 Hand Tools, Powered Equipment & Operating Safety 3.4 Precision Measuring Instruments & Standards Traceability
4 Chapter 4: Fastener Torquing & Avionic Test Equipment
4.1 Torque Wrenches, Extension Calculations & Calibration Care 4.2 Multimeters, Megohmmeters & Insulation Testing 4.3 Bonding Testers, Milliohmmeters & Oscilloscopes
5 Chapter 5: Engineering Drawings, Standards & Fits
5.1 Orthographic Projections, Title Blocks & Revision Control 5.2 Drawing Line Conventions, Symbols & ATA Specification 100/iSpec 2200 5.3 Electrical Schematics, Wiring Interconnects & Component Location 5.4 Systems of Limits, Fits, Clearances & Shaft Alignment
6 Chapter 6: Electrical Wiring Interconnection System (EWIS)
6.1 EWIS Principles, Wire Types & Loom Routing Practices 6.2 Crimp Terminations, Connector Pin Insertion & Extraction Tooling 6.3 Electrical Bonding, Grounding Resistance & Electromagnetic Shielding
7 Chapter 7: Aircraft Riveting Practice
7.1 Solid and Blind Rivet Classifications, Materials & Head Markings 7.2 Rivet Spacing, Pitch, Edge Distance & Structural Layout 7.3 Countersinking, Dimpling Techniques & Rivet Installation 7.4 Rivet Joint Inspection, Failure Modes & Drill-Out Procedures
8 Chapter 8: Sheet Metal Working & Composite Materials
8.1 Sheet Metal Forming, Neutral Axis & Bend Allowance Calculations 8.2 Welding, Brazing, Soldering & Structural Adhesive Bonding 8.3 Composite Reinforcements, Pre-Preg Cold Storage & Clean Room Practice 8.4 Additive Manufacturing in Aircraft Maintenance
9 Chapter 9: Pipes, Flexible Hoses & Springs
9.1 Aircraft Rigid Tubing, Bending & 37-Degree Flaring Standards 9.2 Flexible Hoses, Installation Geometry & Serviceability 9.3 Aircraft Springs: Classifications, Rate Testing & Inspection
10 Chapter 10: Bearings & Mechanical Transmissions
10.1 Bearing Classifications, Load Types & Lubrication Practice 10.2 Bearing Defect Analysis: Spalling, Brinelling & Overheating 10.3 Gears, Gearboxes, Backlash Measurement & Belt/Chain Drives
11 Chapter 11: Flight Control Cables & Rigging
11.1 Aircraft Cable Construction, Sizing & Swaged Terminal Fittings 11.2 Cable Rigging, Turnbuckles & Temperature-Compensated Tensioning 11.3 Pulleys, Fairleads, Cable Inspection & Broken Strand Limits
12 Chapter 12: Aircraft Weight and Balance
12.1 Datum, Arm, Moment & Center of Gravity Principles 12.2 Aircraft Weighing Preparation, Equipment & Tare Deduction 12.3 Center of Gravity Calculations, Flight Limits & Ballast Adjustments
13 Chapter 13: Aircraft Handling, Storage & Winter Operations
13.1 Towing, Taxiing Protocols, Shear Pins & Wing Walkers 13.2 Jacking with Locking Collars, Chocking & Severe Weather Mooring 13.3 Ground De-icing and Anti-icing: Fluids, Clean Aircraft Concept & Holdover Times 13.4 Aircraft Parking, Protective Covers & Engine/Airframe Long-Term Preservation
14 Chapter 14: Inspection, Defect Assessment, Maintenance Procedures & Documentation
14.1 NDT Methods: Liquid Penetrant, Magnetic Particle, Eddy Current, Ultrasonic & Radiography 14.2 Corrosion Classifications, Mechanical Removal & Chemical Surface Treatments 14.3 Inspections After Lightning, Heavy Landing & Other Abnormal Events 14.4 Controlled Disassembly, Inspection & Reassembly 14.5 Troubleshooting, Defect Assessment & Repair Control 14.6 Maintenance Documentation, Work Reports & Shift Handover 14.7 Maintenance Planning, Stores Control, CRS & Occurrence Reporting
1.1 Electrical-System Hazards, Isolation & Protective Equipment
Key Takeaways Explain This Topic AI
The current Part-66 7.4 topic covers electric shock, arc flash and arc blast, stored energy, battery hazards, ESD and electromagnetic hazards, environmental risks, and protective measures.
Isolation is not complete until every energy source is identified, secured against reconnection, and absence of voltage is verified with suitable test equipment in accordance with approved data.
Capacitors, batteries, power electronics, rotating generators, and interconnected buses can retain or recreate hazardous energy after an apparent shutdown.
PPE and insulated tools are selected from the task risk assessment and approved procedure; they do not replace isolation.
ESD controls protect sensitive equipment, while personnel-protection earthing and bonding arrangements must follow the aircraft or component procedure.
Last updated: September 2026
1.1 Electrical-System Hazards, Isolation & Protective Equipment
Commission Implementing Regulation (EU) 2025/111 replaced the reserved Module 7.4 entry with a Level 3 topic on potential safety hazards when working with electrical systems and protective equipment. EASA AMC/GM to Part-66 Issue 2, Amendment 9 expands that scope: electric shock and the effects of current on the body; arc flash and arc blast; stored energy in capacitors, batteries, and power electronics; battery chemical, thermal-runaway, fire, and explosion hazards; electrostatic-discharge and electromagnetic hazards; wet, confined, or inaccessible work environments; and protective measures including PPE, insulated tools, isolation, and verification of absence of voltage.
Why “power off” is not enough
An unlit display or open cockpit switch does not prove that conductors are safe. Aircraft may have hot battery buses, independently supplied emergency buses, external power, ram-air or engine-driven generation, transformer-rectifier or inverter connections, and automatic contactors. Modern high-power systems also contain DC links and capacitors that retain energy after their input is removed. A motor or generator may develop voltage if it is moved. An interconnected system may be back-fed from a source outside the immediate work area.
The maintenance task therefore starts by identifying the complete energy boundary in current approved data. The procedure may require batteries disconnected, external power removed, generators inhibited, circuit breakers opened and secured, connectors disconnected, or mechanical movement prevented. Tags and breaker collars communicate and preserve the condition, but the exact isolation devices and sequence come from the aircraft maintenance manual, component maintenance manual, wiring data, or organisation procedure.
Shock, arc, and stored-energy hazards
Electric shock severity depends on the current path, duration, waveform, frequency, contact area, skin condition, and environment. Wet skin, damaged insulation, conductive structure, cramped access, and simultaneous contact with two points can greatly increase risk. There is no single voltage number that makes every aircraft task safe.
An arc flash is intense thermal and radiant energy from an electrical arc. Arc blast is the accompanying pressure wave, hot gas, molten metal, and flying debris. Low nominal voltage does not eliminate arc risk when batteries or busbars can deliver very high fault current. Rings, watches, necklaces, loose tools, and conductive debris can initiate a short circuit and become incandescent.
Stored energy must be treated as live until the specified discharge time has elapsed and the prescribed test confirms a safe condition. Never short a capacitor with a tool. Use the discharge method, test points, instrument category, probe protection, and waiting time specified in approved data. Where a test-before-touch process is required, prove the tester on a known source, test the circuit, and prove the tester again so a failed instrument cannot create false confidence.
Battery and power-electronics hazards
Lead-acid batteries can produce hydrogen during charging and contain corrosive electrolyte. Nickel-cadmium batteries use caustic electrolyte and can experience damaging thermal behaviour if charging or maintenance is uncontrolled. Lithium battery technologies may develop internal heating, vent flammable or toxic products, and propagate thermal runaway. Chemistry-specific instructions govern isolation, cooling, quarantine, spill response, firefighting support, and transport. A generic action that is suitable for one chemistry can be unsafe for another.
Power-electronic equipment may combine high voltage, stored charge, liquid cooling, and sensitive semiconductor devices. Damage, odour, heat, swelling, smoke, or electrolyte leakage are reasons to stop, isolate the area, and follow the emergency procedure. Do not handle a suspect battery or open power-electronic unit simply because external power has been removed.
ESD and electromagnetic hazards
Electrostatic discharge may damage electronic assemblies at an energy below human perception. An ESD-protected work area controls personnel potential, work-surface charge, packaging, humidity where specified, and handling. A wrist strap protects equipment only when connected through the approved resistance and verified by the required test; it must not be used where it could expose the wearer to live power.
Electromagnetic energy can also be hazardous. Radar, radio, and high-power transmitting systems may require inhibition, warning signs, antenna clearance, and coordination with other teams. Strong fields can affect people, electro-explosive devices, test equipment, or nearby systems. Follow the aircraft and site procedure rather than relying on a generic distance.
Safe task sequence
Read the current task and identify every electrical, mechanical, hydraulic, pneumatic, and stored-energy source that can affect it.
Coordinate the isolation with operations and other maintenance teams. Record or display the work status as the organisation requires.
De-energise using the approved sequence. Secure controls, breakers, connectors, or sources against inadvertent reconnection.
Observe specified discharge or cooling times. Treat batteries, capacitors, and power electronics according to their chemistry and design.
Verify absence of voltage at the prescribed points with suitable, serviceable test equipment. Confirm the tester before and after the check when required.
Establish any protective earth, equipotential bond, ESD control, barriers, or exclusion area specified for the task.
Use task-selected PPE, insulated tools, covers, lighting, ventilation, and rescue arrangements. Stop if access, moisture, contamination, or visibility differs from the assessed condition.
Before re-energising, account for tools and people, restore guards and connectors, remove temporary earths or locks in the controlled sequence, and perform the required functional test.
Protective gloves, face protection, arc-rated clothing, insulating mats, and insulated tools reduce exposure when selected correctly. They are not permission to work live. Energised testing is performed only when the approved procedure requires it, the risk is assessed, boundaries are controlled, and suitable equipment and competence are available.