Study guide

2.3 Montreal Protocol and International Agreements

EPA 608 Technician Certification Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction to EPA 608 Certification

1.1 What EPA 608 Is and Who Needs It 1.2 Exam Format, Scoring, and Administration 1.3 How to Study for EPA 608

2 Regulations and the Clean Air Act

2.1 Clean Air Act Overview 2.2 Penalties and Enforcement 2.3 Montreal Protocol and International Agreements 2.4 AIM Act and HFC Phasedown Schedule 2.5 SNAP Program and Refrigerant Transitions

3 Refrigerants and Ozone Science

3.1 The Science of Ozone Depletion (ODP and GWP) 3.2 Refrigerant Classification, ASHRAE Numbering, and Safety Groups 3.3 Common Refrigerants: Properties, Applications, and Phaseout Status 3.4 Refrigerant Blends: Glide, Fractionation, and Liquid Charging

4 The Refrigeration Cycle

4.1 The Basic Refrigeration Cycle 4.2 System Components in Detail 4.3 Heat Transfer and Pressure-Temperature Relationships

5 Refrigerant Safety and Handling

5.1 Refrigerant Hazards and Health Effects 5.2 Safe Handling Practices, PPE, and Cylinders 5.3 A2L (Mildly Flammable) Refrigerant Safety

6 Recovery, Recycling, and Reclaiming

6.1 The Three Rs: Recover, Recycle, Reclaim 6.2 Recovery Equipment Requirements 6.3 Required Levels of Evacuation 6.4 Refrigerant Sales Restrictions and Recordkeeping

7 Leak Detection and Repair

7.1 Leak Detection Methods 7.2 Leak Repair Requirements and Trigger Rates 7.3 Leak-Rate Calculation, Recordkeeping, and Reporting

8 Type I — Small Appliances

8.1 What Counts as a Small Appliance 8.2 Type I Recovery Requirements 8.3 Type I Procedures, Access Valves, and the Open-Book Exam

9 Type II — High-Pressure Appliances

9.1 What Type II Covers: High-Pressure System Overview 9.2 Type II Recovery Methods and Required Evacuation Levels 9.3 Leak Detection, the Repair Triggers, and Recordkeeping 9.4 The R-22 Phaseout, Retrofits, and the Move to Lower-GWP A2Ls

10 Type III — Low-Pressure Appliances

10.1 Low-Pressure System Fundamentals 10.2 Purge Units and Air Management 10.3 Type III Recovery and Procedures 10.4 Type III Leak Testing

11 10. Disposal, Shipping, and Compliance

11.1 Equipment Disposal Requirements 11.2 Refrigerant Shipping and Transport 11.3 Compliance Checklist and Best Practices

12 Final Review and Exam Strategy

12.1 High-Yield Core Section Review 12.2 Type I vs Type II vs Type III: Side-by-Side Review 12.3 How the Exam Works and Exam-Day Strategy

2.3 Montreal Protocol and International Agreements

Key Takeaways Explain This Topic AI

The Montreal Protocol (1987) is the only UN treaty with universal ratification (198 parties) and phased out ozone-depleting CFCs, halons, and carbon tetrachloride

Chlorine is the ozone-destroying element; one chlorine atom can destroy roughly 100,000 ozone molecules in a catalytic cycle

CFCs were phased out of developed-country production by 1996; HCFCs (like R-22) face a complete production/import phaseout by 2030, with R-22 already ended Jan 1, 2020

The Kigali Amendment (2016) extended the Montreal Protocol to phase DOWN high-GWP HFCs — an 80%+ global cut over 30 years; the U.S. ratified it in 2022

Ozone depletion (ODP) and climate warming (GWP) are two distinct harms: CFCs/HCFCs do both, HFCs only the climate harm

Last updated: June 2026

Why International Agreements Are on the Exam

U.S. refrigerant rules did not appear in a vacuum — they implement international treaties. The EPA 608 exam expects you to know the treaty framework because it explains why certain refrigerants are banned, phased out, or phased down, and when . Two harms drive everything: ozone depletion (measured as ODP) and climate warming (measured as GWP). Keeping these two ideas separate is the single most important conceptual skill in this chapter.

The Ozone Layer and the Role of Chlorine

The ozone layer is a band of ozone (O3) molecules in the stratosphere , roughly 10–30 miles up, that absorbs 97–99% of the sun's harmful ultraviolet-B (UV-B) radiation. Depletion lets more UV-B reach the surface, raising rates of skin cancer and cataracts and damaging crops and marine phytoplankton.

Chlorine is the villain. CFC and HCFC molecules are extremely stable, so they drift intact into the stratosphere (a 2–5 year journey). There, intense UV breaks them apart and frees chlorine atoms . Each chlorine atom catalytically destroys ozone — and is regenerated afterward — so a single chlorine atom can destroy on the order of 100,000 ozone molecules before it is finally deactivated. HFCs and HFOs contain no chlorine , which is exactly why their ODP is zero .

The Montreal Protocol (1987)

The Montreal Protocol on Substances that Deplete the Ozone Layer was adopted in 1987 and has been ratified by 198 parties — the first and only UN treaty to achieve universal ratification . It set binding phaseout schedules for ozone-depleting substances. The developed-country deadlines you should recognize:

  • Substance Action Developed-Country Deadline
  • Halons Complete phaseout January 1, 1994
  • CFCs Complete phaseout January 1, 1996
  • Carbon tetrachloride Complete phaseout January 1, 1996
  • Methyl chloroform Complete phaseout January 1, 1996
  • HCFCs Complete phaseout January 1, 2030

The treaty works through a stepwise reduction : production caps tighten over time rather than dropping to zero overnight. This is why R-22 (an HCFC) had its U.S. production and import end on January 1, 2020 , ahead of the broader 2030 HCFC deadline — EPA front-loaded the most common HCFC.

Ozone Depletion vs. Climate Framing

The Montreal Protocol was designed for ozone protection . But the substitutes industry adopted — HFCs — turned out to be potent greenhouse gases . They solved the ozone problem (zero ODP) while worsening the climate problem (high GWP). That mismatch set up the next chapter of the treaty.

For the Exam: Lock in three facts about chlorine and ODP. (1) Chlorine destroys ozone; HFCs/HFOs have none, so ODP = 0. (2) One chlorine atom destroys ~100,000 ozone molecules. (3) CFCs have the highest ODP (R-11 and R-12 = 1.0); HCFCs are lower (R-22 = 0.055). Do not confuse ODP with GWP — a refrigerant can have zero ODP and still have an enormous GWP.

The Kigali Amendment (2016)

The Kigali Amendment , adopted in Kigali, Rwanda in 2016, extended the Montreal Protocol to cover HFCs — not because they deplete ozone (they do not) but because of their climate impact. Key points:

It mandates a global phasedown of HFC production and consumption — more than an 80% reduction over roughly 30 years .

Developed countries began stepping down HFCs in 2019 ; many developing countries freeze and then reduce on later schedules (with a freeze around 2024 for one major group).

The United States ratified the Kigali Amendment in 2022 , committing to the international HFC phasedown.

The Kigali Amendment is the bridge between the old ozone-focused regime and the new climate-focused regime. In the U.S., it is implemented domestically by the AIM Act (covered in Section 1.4), which is where the concrete percentages and dates live.

Putting the Timeline Together

1987 — Montreal Protocol: attacks ozone-depleting substances (CFCs, halons, HCFCs).

1996 — CFC phaseout complete in developed countries.

2016 — Kigali Amendment: extends the treaty to climate-warming HFCs.

2020 — R-22 production/import ends in the U.S.

2022 — U.S. ratifies Kigali.

2030 — HCFC phaseout complete in developed countries.

A Quick Word on the Vienna Convention

One more name occasionally appears on the exam: the Vienna Convention for the Protection of the Ozone Layer (1985) . It was the framework treaty — the diplomatic agreement that nations would cooperate on ozone science and policy — but it set no binding targets . The Montreal Protocol (1987) is the implementing agreement that added the actual, enforceable phaseout schedules.

If a question contrasts the two, remember: Vienna = framework/cooperation, Montreal = binding phaseouts. Together they explain why the international response to ozone depletion succeeded where many environmental efforts stalled — the science framework came first, then the binding cuts, then the Kigali climate extension.

Ozone Depletion Potential (ODP) by Refrigerant Family