Study guide
13.2 Restricted and Prohibited Practices
EPA Lead Abatement Supervisor 40 CFR 745 Subpart L
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Facts, Supervisor Role, and Certification Path
1.1 Current Exam Facts 1.2 Supervisor Role, Responsibilities, and On-Site Presence 1.3 Prerequisites, Interim Certification, and the Third-Party Exam
2 Chapter 2: Firm Certification, Recertification, and Enforcement
2.1 Firm Certification vs Individual Certification 2.2 Recertification, 8-Hour Refresher, and 3-Year vs 5-Year Cycles 2.3 Suspension, Revocation, TSCA Violations, and Inspections
3 Chapter 3: Title X, 40 CFR 745, State Programs, and HUD Guidelines
3.1 Title X, TSCA 402–406, and 40 CFR 745 Architecture 3.2 Target Housing, Child-Occupied Facilities, and the 1978 Ban 3.3 EPA-Administered vs Authorized State Programs (Subpart Q) and Reciprocity 3.4 HUD Guidelines and Other Documented Methodologies
4 Chapter 4: Lead Health Effects, Blood-Lead Benchmarks, and Liability
4.1 Lead Toxicology, Child and Adult Health Effects, and Blood-Lead Benchmarks 4.2 Liability, Insurance, and Contract Risk for Abatement Supervisors
5 Chapter 5: What Counts as Abatement
5.1 Abatement vs Interim Controls vs RRP 5.2 Lead-Based Paint Definition and Component Language 5.3 Paint-Lead, Dust-Lead, and Soil-Lead Hazard Definitions
6 Chapter 6: Lead Hazard Recognition in the Field
6.1 Deteriorated Paint and Paint in Poor Condition 6.2 Friction, Impact, and Chewable Surface Hazards 6.3 High-Risk Components, Common Areas, and Dust Pathways
7 Chapter 7: Interpreting Inspection and Risk Assessment Reports
7.1 Reading Inspection Reports, XRF Results, and Paint-Chip Data 7.2 Reading Risk Assessment Reports and Selecting Control Options 7.3 Lead Hazard Screens vs Full Risk Assessments
8 Chapter 8: Occupant Protection Plans
8.1 Occupant Protection Plan Requirements 8.2 Relocation, Isolation of Work Areas, and Sensitive Occupants 8.3 Re-Occupancy Criteria, Occupant Notice, and Access Control
9 Chapter 9: Project Notification and Work Plans
9.1 Five-Business-Day Notification Contents and Electronic Filing 9.2 Updated, Canceled, EBL, and Emergency Notifications 9.3 Work Plans, Method Selection Documentation, and Pre-Abatement Walkthrough
10 Chapter 10: Interior Containment Design
10.1 Critical Barriers, Warning Signs, and Regulated Areas 10.2 Negative Air Pressure and HEPA Air-Filtration Units 10.3 Three-Stage Decontamination Units and Worker Flow
11 Chapter 11: Exterior Containment and Site Control
11.1 Exterior Ground Sheeting, Vertical Containment, and Weather Limits 11.2 Daily Exterior Cleanup, Paint-Chip Control, and Occupied/Multi-Family Logistics
12 Chapter 12: Component Replacement, Enclosure, and Encapsulation
12.1 Component Replacement 12.2 Enclosure Systems and Mechanical Fastening 12.3 Encapsulation Products, Unsuitable Surfaces, and Maintenance Schedules
13 Chapter 13: Paint Removal and Restricted Practices
13.1 Wet Scraping, Chemical Removal, and Heat Guns Below 1100°F 13.2 Restricted and Prohibited Practices 13.3 Selecting Methods, Combining Methods, and Documenting Why
14 Chapter 14: Interior Dust Abatement and Cleaning
14.1 Interior Dust Cleanup Sequence 14.2 Pre-Clearance Visual Inspection and When Cleanup Is Not Done
15 Chapter 15: Soil and Exterior Dust Abatement
15.1 Soil-Lead Hazards and Sampling Interpretation for Supervisors 15.2 Soil Removal and Replacement 15.3 Permanent Covering vs Landscaping
16 Chapter 16: OSHA 1926.62 Worker Protection
16.1 PEL, Action Level, and Exposure Assessment 16.2 Respiratory Protection, PPE, and Hygiene Facilities 16.3 Biological Monitoring and Medical Removal Protection 16.4 OSHA Competent Person Duties vs EPA Certified Supervisor Duties
17 Chapter 17: RCRA Waste Management
17.1 Abatement Waste Streams 17.2 TCLP Characterization and D008 17.3 Manifests, TSDF, Accumulation, and the Household Exclusion
18 Chapter 18: Action Levels, Post-Abatement Testing, and Records
18.1 Dust-Lead Action Levels vs Reportable-Level Hazards 18.2 Post-Abatement Visual, Dust Sampling, Independence, and the 1-Hour Wait 18.3 Failed Samples, Reclean/Retest, Exterior Visual, and Multi-Family Random Sampling 18.4 Abatement Report, 2026 Hazard Statement, Owner Copies, and 3-Year Retention
13.2 Restricted and Prohibited Practices
Key Takeaways Explain This Topic AI
Open-flame burning or torching of lead-based paint is prohibited during abatement (40 CFR 745.227(e)(6)(i)). A propane torch, a flaming heat plate, or burning the film is included; a heat gun or infrared unit below 1100°F is not torching.
Machine sanding, grinding, abrasive blasting, or sandblasting of LBP is prohibited unless used with HEPA exhaust control that removes particles of 0.3 microns or larger at 99.97 percent or greater efficiency ((e)(6)(ii)). A needle gun without that exhaust fails.
Dry scraping is permitted only with heat guns, around electrical outlets, or for defective paint totaling no more than 2 square feet in any one room, hallway or stairwell or no more than 20 square feet on exterior surfaces ((e)(6)(iii)). Dry-scraping a whole room fails.
A heat gun on LBP is permitted only below 1100°F ((e)(6)(iv)). Memorize 2 ft², 20 ft², 1100°F, and 0.3 µm at 99.97%.
24 CFR 35.140 prohibits the same family of techniques on HUD-assisted housing and additionally flags charring, dry sanding, and poorly ventilated volatile chemical stripping. Attribute those extras to HUD, not as extra EPA 745.227(e)(6) items. Job pressure does not create an exception.
Last updated: August 2026
Four restricted-practice rules — memorize the numbers
Quick Answer: During abatement, 40 CFR 745.227(e)(6) restricts work practices as follows: (i) open-flame burning or torching of LBP is prohibited ; (ii) machine sanding or grinding or abrasive blasting or sandblasting of LBP is prohibited unless used with HEPA exhaust control which removes particles of 0.3 microns or larger from the air at 99.97 percent or greater efficiency; (iii) dry scraping of LBP is permitted only in conjunction with heat guns or around electrical outlets or when treating defective paint spots totaling no more than 2 square feet in any one room, hallway or stairwell or totaling no more than 20 square feet on exterior surfaces; (iv) operating a heat gun on LBP is permitted only at temperatures below 1100 degrees Fahrenheit . HUD's Lead Safe Housing Rule, 24 CFR 35.140 , prohibits the same family of techniques on HUD-assisted housing and additionally flags charring , dry sanding , and poorly ventilated volatile chemical stripping . Those extras are HUD , not extra EPA (e)(6) items.
These are work practices , not method labels. They apply whether the scope says paint removal, component replacement, enclosure prep, or encapsulant prep. Chapter 12 already used this table when a crew wanted to torch a painted parting bead to free a window. 745.227(e)(3) then stacks every other Federal, State, and local requirement on top — OSHA 1926.62 and, on assisted housing, 24 CFR 35.140 included. Job pressure does not create a fifth exception.
Memorize this table
Cite Rule Numbers to lock Absolute or conditional
(e)(6)(i) Open-flame burning or torching of LBP None — prohibited Absolute. No HEPA exception, no square-footage exception, no just-to-soften exception
(e)(6)(ii) Machine sanding, grinding, abrasive blasting, or sandblasting HEPA must remove 0.3 µm or larger at 99.97% or greater Prohibited unless that HEPA exhaust control is used on the tool
(e)(6)(iii) Dry scraping 2 ft² in any one room, hallway, or stairwell; 20 ft² on exterior surfaces Permitted only with heat guns, around outlets, or within those area caps
(e)(6)(iv) Heat gun Below 1100°F Permitted only under that temperature
Open-flame includes a propane torch, a heat plate that flames, and burning or torching the film. It does not include an infrared unit or a heat gun held below 1100°F . Do not merge (i) and (iv). The 1100°F cap is not a torch exception. If the tool makes a flame, stop. If the tool is a heat gun, read the dial.
HEPA in (ii) is local exhaust on the machine , the same 0.3 µm / 99.97% definition Chapter 10 used for tool exhaust. A respirator on the worker, an air-filtration unit in the corner, or a shop-vac hose taped to a sander is not that control. Room negative air does not legalize an unshrouded grinder.
The interior dry-scrape cap is per room, hallway, or stairwell: no more than 2 square feet of defective paint spots in any one of those spaces. You do not get a fresh 2 ft² every time you turn a corner inside the same room. The exterior cap is no more than 20 square feet on exterior surfaces — a limited-spot allowance, not a whole-elevation strip and not a per-wall reset the rule never wrote.
HUD extras — same job, extra sentences, different cite
On HUD-assisted housing, 24 CFR 35.140 independently says the following methods shall not be used to remove paint that is, or may be, lead-based paint:
- 35.140 HUD text (condensed) Do not file this as EPA (e)(6)
- (a) Open flame burning or torching Already an EPA prohibition
(b)–(c) Machine sanding or grinding, or abrasive blasting or sandblasting, without HEPA local exhaust control Same idea as EPA (ii)
(d) Heat guns above 1100°F or charring the paint Charring is the HUD add-on
(e) Dry sanding or dry scraping, except dry scraping in conjunction with heat guns, within 1.0 ft (0.30 m) of electrical outlets, or 2 sq. ft. in any one interior room or space, or 20 sq. ft. on exterior surfaces Dry sanding and the 1.0 ft outlet radius are HUD specifics
(f) Paint stripping in a poorly ventilated space using a volatile stripper that is a CPSC hazardous substance and/or an OSHA hazardous chemical HUD-only extra prohibition
HUD Guidelines Chapter 12 is a documented methodology under 745.227(a)(3) for how to remove paint. It does not rewrite (e)(6), and (e)(6) does not swallow 35.140. If the unit is HUD-assisted, you obey both . If the unit is not HUD-assisted, you still obey EPA (e)(6) and OSHA; you just do not pretend EPA printed 35.140(f) inside 745.227.
Three exam pictures that fail
1. Torch to soften paint. The sash is stuck. A worker lights a propane torch just to soften the LBP so the crew can scrape. (e)(6)(i) — prohibited. Softening is still torching of LBP. Use a heat gun below 1100°F, chemicals with ventilation, wet methods, or take the component off. Historic wood is not a torch permit.
2. Needle-gun without HEPA. The crew needle-scales an LBP porch column because it feels like a chisel, not a sander. A needle gun is machine grinding / abrasive work. Without HEPA exhaust control that meets 0.3 µm and 99.97 percent or greater, it is prohibited under (e)(6)(ii). The same answer applies to a belt sander, an unshrouded angle grinder, or open sandblasting of a painted cornice. Putting a paper dust mask on the operator does not change the tool rule.
3. Dry-scrape a whole room. Interior living room, 120 ft² of deteriorated LBP. The crew dry-scrapes every wall because the mist bottle is empty and someone said 2 square feet is only a HUD number. Fail. EPA (e)(6)(iii) allows dry scraping of defective spots totaling no more than 2 square feet in any one room, hallway or stairwell . A whole room is not 2 ft². Wet-scrape, chemically strip with ventilation, use a heat gun below 1100°F and scrape in conjunction with it, or use HEPA-shrouded tools.
Worked example — 18 ft² exterior dry scrape. The rear elevation has scattered failed LBP totaling 18 ft² of spots, not a full-wall strip. Dry scraping those spots sits under the 20 ft² exterior allowance. Dry-scraping the remaining 400 ft² of intact film while the ladders are up does not. Do not treat each wall as a fresh 20 ft² budget the regulation did not write; the text is no more than 20 square feet on exterior surfaces .
Worked example — blasting a cornice with a room AFU. The specification wants the exterior cornice stripped to bare metal. The crew open-blasts without tool HEPA and points to a HEPA air-filtration unit in a nearby window. (e)(6)(ii) requires HEPA exhaust control on the blasting/sanding/grinding operation at 0.3 µm / 99.97% . An AFU is not local exhaust on the blaster. HUD Chapter 12, if blasting must be done, also expects a sealed area under negative pressure with HEPA exhaust — and that still does not replace the tool-exhaust sentence in (e)(6)(ii).
What the exceptions are not
HEPA on a blasting tool does not legalize a torch.
A heat gun below 1100°F does not legalize dry-scraping a 200 ft² wall away from the gun.
The 2 ft² interior exception is defective paint spots , not any 2 ft² of intact film you felt like removing dry.
Around electrical outlets is around the outlet , not the room that contains an outlet.
Worker respirators, occupant relocation, weekend overtime, and a GC back-charge threat do not convert a restricted practice into an allowed one.
Calling the work replacement or encapsulant prep does not park (e)(6). Restricted practices apply during an abatement .
Worked example — the owner is in a hurry. The GC says torching will save a day and the occupant returns Friday. Restricted practices cannot be excepted by job pressure (Section 13.3). A faster illegal method is still illegal. Change to a legal method and write that reason in the report.
Official sources: 40 CFR 745.227(e)(3) and (e)(6) ; 24 CFR 35.140 ; HUD Guidelines Chapter 12 as a documented methodology under 745.227(a)(3).