Study guide

3.1 Title X, TSCA 402–406, and 40 CFR 745 Architecture

EPA Lead Abatement Supervisor 40 CFR 745 Subpart L

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Facts, Supervisor Role, and Certification Path

1.1 Current Exam Facts 1.2 Supervisor Role, Responsibilities, and On-Site Presence 1.3 Prerequisites, Interim Certification, and the Third-Party Exam

2 Chapter 2: Firm Certification, Recertification, and Enforcement

2.1 Firm Certification vs Individual Certification 2.2 Recertification, 8-Hour Refresher, and 3-Year vs 5-Year Cycles 2.3 Suspension, Revocation, TSCA Violations, and Inspections

3 Chapter 3: Title X, 40 CFR 745, State Programs, and HUD Guidelines

3.1 Title X, TSCA 402–406, and 40 CFR 745 Architecture 3.2 Target Housing, Child-Occupied Facilities, and the 1978 Ban 3.3 EPA-Administered vs Authorized State Programs (Subpart Q) and Reciprocity 3.4 HUD Guidelines and Other Documented Methodologies

4 Chapter 4: Lead Health Effects, Blood-Lead Benchmarks, and Liability

4.1 Lead Toxicology, Child and Adult Health Effects, and Blood-Lead Benchmarks 4.2 Liability, Insurance, and Contract Risk for Abatement Supervisors

5 Chapter 5: What Counts as Abatement

5.1 Abatement vs Interim Controls vs RRP 5.2 Lead-Based Paint Definition and Component Language 5.3 Paint-Lead, Dust-Lead, and Soil-Lead Hazard Definitions

6 Chapter 6: Lead Hazard Recognition in the Field

6.1 Deteriorated Paint and Paint in Poor Condition 6.2 Friction, Impact, and Chewable Surface Hazards 6.3 High-Risk Components, Common Areas, and Dust Pathways

7 Chapter 7: Interpreting Inspection and Risk Assessment Reports

7.1 Reading Inspection Reports, XRF Results, and Paint-Chip Data 7.2 Reading Risk Assessment Reports and Selecting Control Options 7.3 Lead Hazard Screens vs Full Risk Assessments

8 Chapter 8: Occupant Protection Plans

8.1 Occupant Protection Plan Requirements 8.2 Relocation, Isolation of Work Areas, and Sensitive Occupants 8.3 Re-Occupancy Criteria, Occupant Notice, and Access Control

9 Chapter 9: Project Notification and Work Plans

9.1 Five-Business-Day Notification Contents and Electronic Filing 9.2 Updated, Canceled, EBL, and Emergency Notifications 9.3 Work Plans, Method Selection Documentation, and Pre-Abatement Walkthrough

10 Chapter 10: Interior Containment Design

10.1 Critical Barriers, Warning Signs, and Regulated Areas 10.2 Negative Air Pressure and HEPA Air-Filtration Units 10.3 Three-Stage Decontamination Units and Worker Flow

11 Chapter 11: Exterior Containment and Site Control

11.1 Exterior Ground Sheeting, Vertical Containment, and Weather Limits 11.2 Daily Exterior Cleanup, Paint-Chip Control, and Occupied/Multi-Family Logistics

12 Chapter 12: Component Replacement, Enclosure, and Encapsulation

12.1 Component Replacement 12.2 Enclosure Systems and Mechanical Fastening 12.3 Encapsulation Products, Unsuitable Surfaces, and Maintenance Schedules

13 Chapter 13: Paint Removal and Restricted Practices

13.1 Wet Scraping, Chemical Removal, and Heat Guns Below 1100°F 13.2 Restricted and Prohibited Practices 13.3 Selecting Methods, Combining Methods, and Documenting Why

14 Chapter 14: Interior Dust Abatement and Cleaning

14.1 Interior Dust Cleanup Sequence 14.2 Pre-Clearance Visual Inspection and When Cleanup Is Not Done

15 Chapter 15: Soil and Exterior Dust Abatement

15.1 Soil-Lead Hazards and Sampling Interpretation for Supervisors 15.2 Soil Removal and Replacement 15.3 Permanent Covering vs Landscaping

16 Chapter 16: OSHA 1926.62 Worker Protection

16.1 PEL, Action Level, and Exposure Assessment 16.2 Respiratory Protection, PPE, and Hygiene Facilities 16.3 Biological Monitoring and Medical Removal Protection 16.4 OSHA Competent Person Duties vs EPA Certified Supervisor Duties

17 Chapter 17: RCRA Waste Management

17.1 Abatement Waste Streams 17.2 TCLP Characterization and D008 17.3 Manifests, TSDF, Accumulation, and the Household Exclusion

18 Chapter 18: Action Levels, Post-Abatement Testing, and Records

18.1 Dust-Lead Action Levels vs Reportable-Level Hazards 18.2 Post-Abatement Visual, Dust Sampling, Independence, and the 1-Hour Wait 18.3 Failed Samples, Reclean/Retest, Exterior Visual, and Multi-Family Random Sampling 18.4 Abatement Report, 2026 Hazard Statement, Owner Copies, and 3-Year Retention

3.1 Title X, TSCA 402–406, and 40 CFR 745 Architecture

Key Takeaways Explain This Topic AI

The Residential Lead-Based Paint Hazard Reduction Act of 1992 (Title X of the Housing and Community Development Act of 1992) directed EPA and HUD to build the federal lead program; Title X added TSCA Title IV (Lead Exposure Reduction).

TSCA section 402 drives training, certification, and work practices (Subpart L abatement and Subpart E RRP); 403 drives hazard standards (Subpart D); 404 drives state/tribal authorization (Subpart Q); 406 drives pre-renovation information; Title X section 1018 drives sale/lease disclosure (Subpart F).

An EPA certified abatement supervisor lives in 40 CFR 745 Subpart L (745.220–745.239), not in Subpart E RRP. A renovator certificate does not authorize abatement.

Subpart L applies only in States or Indian Country without an authorized program under 745.324, plus a narrow owner-occupant exception; federal facilities must still comply with all Federal, State, interstate, and local lead requirements including this subpart (745.220(c)).

On or after January 12, 2026, dust-lead action levels are 5 / 40 / 100 µg/ft² (floors / interior window sills / window troughs); a dust-lead hazard is any reportable level on floors or sills. Full clearance protocol is Chapter 18.

Last updated: August 2026

Title X, TSCA 402–406, and 40 CFR 745 Architecture

Quick answer: Congress passed the Residential Lead-Based Paint Hazard Reduction Act of 1992 as Title X of the Housing and Community Development Act of 1992. Title X told EPA and HUD to stand up lead programs and added TSCA Title IV — Lead Exposure Reduction . EPA’s implementing rules live in 40 CFR Part 745 . Your supervisor card, firm certification, and abatement work practices are Subpart L , not the Subpart E Renovation, Repair, and Painting ( RRP ) rule.

The exam will not ask you to recite the Public Law number. It will ask which statute created training and work practices, which subpart covers abatement, and whether a renovator certificate lets you run an abatement. Hold the map, then apply it to the jobsite.

From Title X to TSCA Title IV

Title X is the housing statute. It directed HUD (especially federally assisted housing and disclosure at sale or lease) and EPA (training, certification, work practices, hazard standards, and state authorization) to reduce childhood lead exposure in housing. Title X also amended the Toxic Substances Control Act (TSCA) by adding Title IV . The TSCA section numbers you will see on the exam are Title IV sections:

Statute What it ordered Where EPA put it in 40 CFR 745

TSCA 402 Training, accreditation, certification, and work practices for lead-based paint activities; later 402(c) added renovation Subpart L (inspection, risk assessment, abatement); Subpart E (RRP)

TSCA 403 Identification of dangerous levels of lead (hazard standards) Subpart D (745.61–745.65), with matching determinations in 745.227(h)

TSCA 404 State and tribal program authorization Subpart Q (745.320–745.339, especially 745.324 and 745.325 )

TSCA 406 Pre-renovation information (the pamphlet obligation) Subpart E (pre-renovation education, alongside RRP)

Title X § 1018 Disclosure of known lead-based paint and hazards before sale or lease of target housing Subpart F (EPA) and 24 CFR Part 35 Subpart A (HUD)

Section 1018 is a Title X housing provision, not a TSCA 402–406 section. Supervisors still need it: owners and agents must disclose known LBP and hazards in target housing before a buyer or tenant is obligated. That disclosure file is often sitting in the unit you are about to abate. It is not a substitute for a current inspection or risk assessment, and it does not authorize you to skip Subpart L work practices. Title X (1992 housing statute)

  • |
  • +-- HUD: disclosure (1018), Lead Safe Housing Rule (24 CFR 35)
  • |
  • +-- EPA: TSCA Title IV
  • |
  • +-- 402 training / cert / work practices --> Part 745 Subparts L and E
  • +-- 403 hazard standards --> Part 745 Subpart D
  • +-- 404 state/tribal authorization --> Part 745 Subpart Q
  • +-- 406 pre-renovation information --> Part 745 Subpart E
  • Part 745 subparts you must not mix

40 CFR Part 745 is titled Lead-Based Paint Poisoning Prevention in Certain Residential Structures . For this exam, five subparts matter:

Subpart D — Lead-Based Paint Hazards. TSCA 403 numbers: what is a paint-lead, dust-lead, or soil-lead hazard. On or after January 12, 2026 , a dust-lead hazard exists on floors and interior window sills at any reportable level . Action levels used to complete abatement when dust sampling is required are 5 µg/ft² floors, 40 µg/ft² interior window sills, and 100 µg/ft² window troughs . Those two ideas are not the same. Abatement is complete only when dust is below action levels ; a reportable result that is still below the action level is still a dust-lead hazard and triggers the dust-lead hazard statement in the abatement report. Chapter 18 owns the sampling protocol; memorize the 2026 numbers here so later chapters have somewhere to hang them.

Subpart E — Residential Property Renovation (RRP). Certified renovators and RRP firms . Lead-safe work practices for renovation, repair, and painting that is not designed as abatement . Pre-renovation pamphlet rules live here too.

Subpart F — Disclosure. Sale and lease of target housing. Owners, lessors, and agents — not your abatement certificate — are the primary duty-holders.

Subpart L — Lead-Based Paint Activities (745.220–745.239). Inspection, risk assessment, and abatement. This is the supervisor’s home: 745.223 definitions, 745.225 training, 745.226 certification of individuals and firms, 745.227 work practices, 745.238 fees.

Subpart Q — State and Indian Tribal Programs. How a State or Tribe takes over administration in lieu of EPA. Covered in Section 3.3.

Do not mix RRP renovator with abatement supervisor. A certified renovator under Subpart E may disturb lead-based paint during a kitchen remodel. That person is not certified to supervise abatement — permanent elimination of LBP hazards (for dust-lead, to below action levels). A certified supervisor under Subpart L is trained and certified to supervise and conduct abatements and to prepare occupant protection plans and abatement reports . Using an RRP card on an abatement, or calling a gut-rehab “RRP” because the crew prefers the lighter rule, is a TSCA violation and a classic exam trap.

745.220: who Subpart L actually covers

745.220(a) says Subpart L contains accreditation of training programs, certification of individuals and firms, and work practice standards, and that all lead-based paint activities (as defined in the subpart) must be performed by certified individuals and firms , except as discussed below.

745.220(b) is the applicability paragraph. Three ideas sit in one sentence:

Covered persons. Subpart L applies to all individuals and firms engaged in lead-based paint activities as defined in 745.223 .

Owner-occupant exception. It does not apply to persons who perform those activities within residential dwellings that they own , unless (i) the dwelling is occupied by a person or persons other than the owner or the owner’s immediate family while the activities are being performed, or (ii) a child residing in the building has been identified as having an elevated blood lead level (EBL) . A landlord abating a tenant-occupied unit is in. An owner-occupant abating the house the family lives in, with no EBL child in the building, is out of Subpart L. Bring in a paid crew that is not the owner, and the crew is in.

Geographic trigger. Subpart L applies only in those States or Indian Country that do not have an authorized State or Tribal program pursuant to 745.324 . In an authorized State, you follow that State’s certified-supervisor program, not EPA’s card, unless you are on a job that EPA still runs. Section 3.3 is the field rule: check the jobsite’s jurisdiction before you mobilize.

745.220(c) — federal facilities. Each department, agency, and instrumentality of the executive, legislative, and judicial branches of the Federal Government having jurisdiction over any property or facility, or engaged in any activity that results or may result in a lead-based paint hazard, and each officer, agent, or employee thereof, shall be subject to, and comply with, all Federal, State, interstate, and local requirements , both substantive and procedural, including the requirements of this subpart . A federal courthouse daycare, a VA housing unit, or a military family-housing abatement is not “off the EPA books” because it is federal property. Federal actors must meet Subpart L and whatever State or local lead rules apply to that site.

745.220(d) is the other trap: nothing in Subpart L requires an owner or occupant to undertake any particular lead-based paint activity. The rule tells you how to inspect, assess, or abate if those activities are undertaken. It does not, by itself, order every pre-1978 owner to abate. HUD’s Lead Safe Housing Rule, a State EBL order, or a contract can create the duty; Subpart L then supplies the work practices.

OSHA sits beside EPA, not inside Part 745

29 CFR 1926.62 (Lead in Construction) is worker-protection law. It applies on abatement sites in addition to EPA. EPA tells you who may perform the activity and how to protect occupants and the housing; OSHA tells you how to protect employees (PEL, action level, respirators, hygiene, medical removal). Full OSHA is Chapter 16. Do not look for the 50 µg/m³ PEL inside 745.227.

Supervisor field rule from this architecture

When a bid lands:

Is the work abatement (permanent elimination of LBP hazards) or RRP / interim controls? If abatement, Subpart L (or the authorized-state equivalent) controls the crew credentials and 745.227 practices.

Is the building target housing or a child-occupied facility ? Definitions are Section 3.2.

Who issues the card on this jobsite — EPA or an authorized State/Tribe? Section 3.3.

Which documented methodologies will you use to implement sampling, containment, and cleaning? Section 3.4. HUD Guidelines help you do 745.227; they do not replace it.