Study guide
17.2 TCLP Characterization and D008
EPA Lead Abatement Supervisor 40 CFR 745 Subpart L
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Facts, Supervisor Role, and Certification Path
1.1 Current Exam Facts 1.2 Supervisor Role, Responsibilities, and On-Site Presence 1.3 Prerequisites, Interim Certification, and the Third-Party Exam
2 Chapter 2: Firm Certification, Recertification, and Enforcement
2.1 Firm Certification vs Individual Certification 2.2 Recertification, 8-Hour Refresher, and 3-Year vs 5-Year Cycles 2.3 Suspension, Revocation, TSCA Violations, and Inspections
3 Chapter 3: Title X, 40 CFR 745, State Programs, and HUD Guidelines
3.1 Title X, TSCA 402–406, and 40 CFR 745 Architecture 3.2 Target Housing, Child-Occupied Facilities, and the 1978 Ban 3.3 EPA-Administered vs Authorized State Programs (Subpart Q) and Reciprocity 3.4 HUD Guidelines and Other Documented Methodologies
4 Chapter 4: Lead Health Effects, Blood-Lead Benchmarks, and Liability
4.1 Lead Toxicology, Child and Adult Health Effects, and Blood-Lead Benchmarks 4.2 Liability, Insurance, and Contract Risk for Abatement Supervisors
5 Chapter 5: What Counts as Abatement
5.1 Abatement vs Interim Controls vs RRP 5.2 Lead-Based Paint Definition and Component Language 5.3 Paint-Lead, Dust-Lead, and Soil-Lead Hazard Definitions
6 Chapter 6: Lead Hazard Recognition in the Field
6.1 Deteriorated Paint and Paint in Poor Condition 6.2 Friction, Impact, and Chewable Surface Hazards 6.3 High-Risk Components, Common Areas, and Dust Pathways
7 Chapter 7: Interpreting Inspection and Risk Assessment Reports
7.1 Reading Inspection Reports, XRF Results, and Paint-Chip Data 7.2 Reading Risk Assessment Reports and Selecting Control Options 7.3 Lead Hazard Screens vs Full Risk Assessments
8 Chapter 8: Occupant Protection Plans
8.1 Occupant Protection Plan Requirements 8.2 Relocation, Isolation of Work Areas, and Sensitive Occupants 8.3 Re-Occupancy Criteria, Occupant Notice, and Access Control
9 Chapter 9: Project Notification and Work Plans
9.1 Five-Business-Day Notification Contents and Electronic Filing 9.2 Updated, Canceled, EBL, and Emergency Notifications 9.3 Work Plans, Method Selection Documentation, and Pre-Abatement Walkthrough
10 Chapter 10: Interior Containment Design
10.1 Critical Barriers, Warning Signs, and Regulated Areas 10.2 Negative Air Pressure and HEPA Air-Filtration Units 10.3 Three-Stage Decontamination Units and Worker Flow
11 Chapter 11: Exterior Containment and Site Control
11.1 Exterior Ground Sheeting, Vertical Containment, and Weather Limits 11.2 Daily Exterior Cleanup, Paint-Chip Control, and Occupied/Multi-Family Logistics
12 Chapter 12: Component Replacement, Enclosure, and Encapsulation
12.1 Component Replacement 12.2 Enclosure Systems and Mechanical Fastening 12.3 Encapsulation Products, Unsuitable Surfaces, and Maintenance Schedules
13 Chapter 13: Paint Removal and Restricted Practices
13.1 Wet Scraping, Chemical Removal, and Heat Guns Below 1100°F 13.2 Restricted and Prohibited Practices 13.3 Selecting Methods, Combining Methods, and Documenting Why
14 Chapter 14: Interior Dust Abatement and Cleaning
14.1 Interior Dust Cleanup Sequence 14.2 Pre-Clearance Visual Inspection and When Cleanup Is Not Done
15 Chapter 15: Soil and Exterior Dust Abatement
15.1 Soil-Lead Hazards and Sampling Interpretation for Supervisors 15.2 Soil Removal and Replacement 15.3 Permanent Covering vs Landscaping
16 Chapter 16: OSHA 1926.62 Worker Protection
16.1 PEL, Action Level, and Exposure Assessment 16.2 Respiratory Protection, PPE, and Hygiene Facilities 16.3 Biological Monitoring and Medical Removal Protection 16.4 OSHA Competent Person Duties vs EPA Certified Supervisor Duties
17 Chapter 17: RCRA Waste Management
17.1 Abatement Waste Streams 17.2 TCLP Characterization and D008 17.3 Manifests, TSDF, Accumulation, and the Household Exclusion
18 Chapter 18: Action Levels, Post-Abatement Testing, and Records
18.1 Dust-Lead Action Levels vs Reportable-Level Hazards 18.2 Post-Abatement Visual, Dust Sampling, Independence, and the 1-Hour Wait 18.3 Failed Samples, Reclean/Retest, Exterior Visual, and Multi-Family Random Sampling 18.4 Abatement Report, 2026 Hazard Statement, Owner Copies, and 3-Year Retention
17.2 TCLP Characterization and D008
Key Takeaways Explain This Topic AI
A solid waste exhibits the toxicity characteristic if a TCLP (SW-846 Method 1311) extract from a representative sample contains lead at or above 5.0 mg/L (40 CFR 261.24 Table 1). The EPA hazardous waste number is D008.
TCLP is a leach test, not a total-lead test and not an XRF reading. Compare the lab's mg/L extract to 5.0 mg/L. Do not treat 5 µg/ft² dust action levels or 1.0 mg/cm² LBP as the D008 number.
Paint chips, dust, sludge, and HEPA filters often fail; whole architectural components sometimes do not. Never assume — characterize the stream or apply a lawful exclusion. Do not average a failing hotspot with a passing sample to invent a pass.
The generator determines whether each solid waste is hazardous (40 CFR 262.11) using testing and/or knowledge of the waste. Representative sampling means sampling the stream you actually generated, not the cleanest board in the pile.
Last updated: August 2026
5.0 mg/L in the leachate is D008 — not 5 µg/ft² on a wipe
Quick Answer: A solid waste (except manufactured-gas-plant waste) exhibits the toxicity characteristic if, using the Toxicity Characteristic Leaching Procedure ( TCLP , SW-846 Method 1311 ), the extract from a representative sample contains any Table 1 contaminant at a concentration equal to or greater than the regulatory level ( 40 CFR 261.24 ). For lead , that level is 5.0 mg/L . The EPA hazardous waste number is D008 (CAS 7439-92-1). 5.0 mg/L counts. 4.9 mg/L does not. TCLP is a leach test. It is not total lead in mg/kg, not an XRF mg/cm² reading, and not a dust wipe in µg/ft². Paint chips, dust, sludge, and filters often fail; whole components sometimes do not. Never assume.
Section 17.1 named the piles. This section is how RCRA decides whether a pile that is not lawfully excluded is characteristic hazardous waste . The household exclusion (Section 17.3) can take residential LBP waste out of Subtitle C even when the chips would have failed TCLP. That exclusion is not a characterization, and it does not apply to a non-residential job. When you must decide D008, you use 261.24 .
How TCLP works in plain language
Landfills are acidic. Rainwater and decaying garbage make a weak acid that can pull metals out of solid waste and into leachate that might reach groundwater. Method 1311 is a laboratory imitation of that process:
The lab takes a representative sample of the waste you actually generated.
If the waste has enough solids, the lab extracts it with a specified acetic-acid leaching fluid at a 20:1 liquid-to-solid ratio, with agitation, for a set time.
The lab filters the mixture and analyzes the liquid extract (the leachate) for Table 1 contaminants, including lead .
If the waste contains less than 0.5 percent filterable solids , 261.24(a) says the waste itself, after filtering, is the extract.
Compare the extract, in mg/L , to Table 1. Lead ≥ 5.0 mg/L → toxicity characteristic → waste code D008 .
Equal to or greater than. A result of 5.0 mg/L is D008. Do not round 5.0 down because it feels like a tie. Do not round 4.96 up because it feels close.
Units traps that fail this exam:
Number you already know Unit What it measures Is it the D008 trigger?
- 5.0 mg/L in the TCLP extract How much lead leached in Method 1311 Yes. Table 1 regulatory level
- 5 µg/ft² on a floor wipe Dust-lead action level on or after January 12, 2026 No. Clearance, not RCRA
- 1.0 mg/cm² XRF or 0.5% by weight Lead-based paint definition No. Presence of LBP, not leachate
- 400 / 1,200 ppm in bare soil Soil-lead hazard (play area / rest of yard) No. Hazard definition, not TCLP
Total lead mg/kg or ppm in the solid How much lead is in the waste Not the Table 1 number. High total lead often predicts a fail; only the extract decides D008
A useful screening idea from Method 1311's 20:1 extraction is the so-called 20-times check: if every milligram of lead in the solid dissolved, the extract still could not reach 5.0 mg/L unless total lead were at least about 100 mg/kg (20 × 5). Concentrated chips and dust are typically thousands of mg/kg and often fail . A bulky wood door may sit near or below that range or still fail once the paint film is crushed. The 20-times check is screening logic , not a license to skip TCLP or generator knowledge when you need a determination. If total lead is high enough that a fail is possible, you test or you have documented knowledge — you do not guess.
Representative sampling is the whole determination
261.24 says representative sample . 40 CFR 262.11 says a person who generates a solid waste must determine whether it is hazardous, using testing, knowledge, or both. Supervisors do not become chemists, but they do decide what goes in the sample jar.
Sample the stream you generated.
Chips sampled as chips. Do not dilute a jar of scrape-chips with clean framing lumber and call the mix representative of the chip pile.
A whole door sampled as the door. Do not peel only the paint film, TCLP that film, and assign D008 to every stick of wood on the truck unless that is actually how you will dispose of it (for example, you stripped the paint into its own drum).
Filters sampled as loaded filters, not as the cardboard box they shipped in.
Soil sampled as the excavated soil, not as the 400 ppm play-area composite the risk assessor already reported. Hazard ppm is not TCLP mg/L.
Do not average away a hotspot. If one sample of a chip drum is 8 mg/L and another is 0 mg/L , you do not report 4 mg/L and call the drum non-hazardous. Known hot material is its own stream, or the whole mixed load is managed as hazardous. EPA's TCLP technical assistance has made the same point: the regulatory average is not a license to bury a fail inside a pass.
Generator knowledge can include process knowledge (this drum is nothing but scrape-chips from 4.0 mg/cm² paint; similar chip streams from this firm have failed TCLP) plus prior lab data. Knowledge is not I have been doing this twenty years and doors never fail. If you do not know, test .
Worked example — two piles, one XRF. Interior doors XRF at 3.8 mg/cm². Pile A is the doors, intact. Pile B is the wet-scrape chips from the jambs plus the HEPA filter. A representative TCLP of Pile A returns 1.2 mg/L — not D008. A representative TCLP of Pile B returns 22 mg/L — D008 . Mixing B into A to get a single truck that 'probably passes' is not representative sampling. It is concealment of a characteristic waste.
Worked example — 4.9 versus 5.0. The lab reports TCLP lead 5.0 mg/L on the sludge. That is D008. The helper wants to resample until a 4.9 appears. Resampling a different representative aliquot because the first one was mishandled is laboratory quality control. Resampling until you like the number is not.
Why the concentrated streams fail more often
TCLP rewards surface area and concentration . Paint chips are almost pure film. Dust and HEPA cake are fines. Chemical-stripper sludge is lead paste. Those materials present a lot of lead to the acetic acid. A whole window, door, or piece of siding presents a thin film on a large mass of wood or metal . After the lab crushes a representative piece, the extract is often below 5.0 mg/L — often , not always . Weathered, thick, or alligatored films, metal components with little substrate mass, and debris that is really chips in a bag labeled 'trim' can still fail.
Never assume is the exam sentence. Characterized waste or a lawful exclusion (Section 17.3). There is no third path called it looks like a door so it is C&D.
Other Table 1 metals (arsenic, cadmium, chromium, and the rest) have their own codes. Lead abatement sludge from solvent strippers may also be ignitable ( D001 ) if the flash point is low. Those are extra determinations, not substitutes for the lead TCLP.
What the supervisor does with a D008 result
If the exclusion in Section 17.3 does not apply and TCLP lead is ≥ 5.0 mg/L , the waste is hazardous waste D008 . That triggers generator duties: EPA identification number (for SQG and LQG), Uniform Hazardous Waste Manifest , licensed transporter, licensed TSDF , land-disposal restrictions, and accumulation-time limits under Part 262 . Those mechanics are Section 17.3. This section's job is to get the number and the code right.
If TCLP lead is below 5.0 mg/L and no listing applies, the waste is not D008. It is still lead-containing solid waste . You still contain it, you still keep children off it, and the authorized state may still regulate it more tightly than EPA. A pass on TCLP is not permission to dump it in a play area.
Supervisor decision test before the lab pickup. (1) Did I sample each stream, not a composite of doors-plus-chips? (2) Is the lab running Method 1311 and reporting mg/L in the extract ? (3) Am I comparing to 5.0 mg/L , counting equality as a fail? (4) Did I refuse to average a hotspot into a pass? (5) Am I about to confuse this number with 5 µg/ft², 1.0 mg/cm², or 400 ppm?
Official sources: 40 CFR 261.24 (TCLP Method 1311; Table 1 lead 5.0 mg/L ; D008 ); 40 CFR 261.3 ; 40 CFR 262.11 (hazardous-waste determination); 40 CFR 745.223 (hazardous waste means 261.3).