Study guide

Optical and ultrasound biometry

European Board of Ophthalmology Diploma EBOD

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: EBOD Examination, Applications and Regulations

EBOD Format, Scoring and Revision Planning Eligibility, Applications and the Diploma Online Rules, Technical Preparation and Appeals

2 Chapter 2: Physical Optics, Photometry and Lenses

Light, refraction and total internal reflection Photometry, contrast, colour and adaptation Prisms, decentration and vector combination Vergence, astigmatic lenses and Sturm’s conoid

3 Chapter 3: Instrument Optics, Aberrations and Laser Physics

Cross-cylinder and diagnostic instrument optics Aberrations, duochrome and wavefront analysis Diffraction, polarization, lasers and OCT

4 Chapter 4: Refraction, Accommodation and Spectacle Prescribing

Objective and cycloplegic refraction Subjective refraction and binocular balance Accommodation, presbyopia and vertex distance Spectacle Materials, Measurement and Progressive Lenses

5 Chapter 5: Contact Lenses and Low-Vision Rehabilitation

Contact-lens optics, materials and tear lenses Contact-lens fit and complications Low-vision assessment and magnification Low-vision aids, calculations and ergonomics

6 Chapter 6: Extraocular Anatomy and Motor Physiology

Extraocular muscle anatomy and innervation Eye axes, kinematics and muscle actions Motor laws and orbital pulleys

7 Chapter 7: Binocular Vision and Amblyopia

Binocular vision, stereopsis and the horopter Suppression, correspondence and microtropia Sensory tests and amblyopia treatment

8 Chapter 8: Childhood Assessment and Strabismus Testing

Visual Development, Childhood Testing and Developmental Delay History, corneal reflexes and cover tests Motility patterns, three-step testing and Hess charts

9 Chapter 9: Esotropia, Exotropia and Vertical Deviations

Infantile and accommodative esotropia Exotropia classification and management Vertical Deviations, A–V Patterns and Skew

10 Chapter 10: Dysinnervation, Nystagmus and Muscle Surgery

Duane syndrome, Brown syndrome and restriction Nystagmus patterns and investigation Nystagmus and muscle surgery principles

11 Chapter 11: ROP and Paediatric Ocular Disease

Retinopathy of Prematurity: Screening, Classification and Follow-up Childhood Cataract, Leukocoria and Congenital Glaucoma Childhood Systemic Disease, Infection and Safeguarding

12 Chapter 12: Ocular Surface Anatomy and Infection

Corneal, Conjunctival and Scleral Structure: Examination and Sampling Bacterial keratitis, sampling and treatment Fungal, amoebic and herpetic keratitis Infectious, chlamydial and neonatal conjunctivitis

13 Chapter 13: Allergy, Cicatrisation and Surface Inflammation

Allergic eye disease, trachoma and phlyctenules Cicatrising Conjunctivitis: Mucous Membrane Pemphigoid and SJS/TEN Dry eye, blepharitis and meibomian dysfunction PUK, interstitial keratitis and scleritis

14 Chapter 14: Anterior Segment Dysgenesis and Corneal Dystrophies

Anterior Segment Dysgenesis, Aniridia and Congenital Corneal Opacity IC3D and epithelial or Bowman-layer dystrophies Stromal corneal dystrophies Endothelial corneal dystrophies

15 Chapter 15: Corneal Degeneration, Ectasia and Epithelial Failure

Corneal Degenerations, Pterygium, Band Keratopathy and Dellen Keratoconus and clinical ectasia signs Ectasia imaging, cross-linking and rehabilitation Recurrent Erosion, Neurotrophic Keratopathy and Vitamin A Deficiency

16 Chapter 16: Surface Reconstruction and Keratoplasty

Limbal Stem-Cell Failure, Tarsorrhaphy and Phototherapeutic Keratectomy PK, DALK and endothelial keratoplasty Corneal graft immunity and rejection recognition Graft rejection treatment and postoperative problems

17 Chapter 17: Lens Development, Cataract Assessment and Biometry

Lens Development, Congenital Shape and Ectopia Lentis Lens anatomy and age-related cataract phenotypes Cataract grading, secondary causes and childhood disease Optical and ultrasound biometry

18 Chapter 18: IOL Planning and Phacoemulsification

Keratometry and IOL power formulae Post-refractive biometry, toric alignment and IOL design Phaco fluidics and ultrasound delivery Wounds, OVDs and nucleus techniques

19 Chapter 19: Cataract Anaesthesia and Surgical Complications

Cataract Anaesthesia, Alternative Extraction and Combined Procedures IFIS, capsule rupture and compromised support Postoperative inflammation, haemorrhage and PCO

20 Chapter 20: Corneal and Intraocular Refractive Surgery

Excimer ablation, PRK and LASIK SMILE, surgical selection and complications Phakic IOLs and refractive lens exchange

21 Chapter 21: Presbyopia Procedures and Surface Therapeutics

Presbyopia Surgery, Monovision and Historical Refractive Procedures Surface antimicrobial and anti-inflammatory pharmacology Surface healing, amnion and cenegermin

22 Chapter 22: Aqueous Dynamics, Tonometry and Gonioscopy

Ciliary body and aqueous secretion Outflow and the Goldmann pressure model Tonometry, corneal thickness and biomechanics Gonioscopy optics, landmarks and indentation

23 Chapter 23: Angle, Disc and Visual-Field Assessment

Angle grading and anterior-segment imaging Optic-disc examination and documentation OCT and automated perimetry

24 Chapter 24: Glaucoma Progression, Suspects and Secondary Mechanisms

Field reliability and progression Ocular hypertension, suspects and juvenile glaucoma Lens-related glaucoma, aqueous misdirection and venous pressure

25 Chapter 25: POAG, Angle Closure and Pigmentary Disease

POAG, target pressure and normal-tension disease Angle-closure classification and mechanisms Acute angle closure, iridotomy and lens extraction Pseudoexfoliation and pigmentary glaucoma

26 Chapter 26: Glaucoma Medical, Laser and Surgical Treatment

Neovascular, uveitic and steroid-response glaucoma Glaucoma medicines, SLT and MIGS Trabeculectomy and drainage implants Nonpenetrating surgery, cyclodestruction and postoperative lasers

27 Chapter 27: Retinal Imaging, Diabetes and Vascular Occlusion

Retinal anatomy, examination and multimodal imaging Diabetic microangiopathy and NPDR classification PDR, macular oedema and diabetic trials Retinal vein and artery occlusions

28 Chapter 28: Uncommon Vascular Disease and Myopic Maculopathy

Macroaneurysm, sickle retinopathy and retinal periphlebitis Coats disease and leukocoria assessment MacTel and radiation retinopathy Myopic maculopathy and presumed ocular histoplasmosis

29 Chapter 29: Inherited Retina and Electrophysiology

Retinitis pigmentosa and inherited degeneration Stargardt, Best disease and retinal electrophysiology Cone disorders, stationary night blindness and syndromic retina

30 Chapter 30: AMD, Geographic Atrophy and Pachychoroid

AMD biology and clinical staging Drusen, geographic atrophy and neovascular phenotypes Neovascular AMD trials and treatment CSCR and the pachychoroid spectrum

31 Chapter 31: Retinal Breaks and Detachment Repair

PVD, peripheral degenerations and retinal breaks RRD localization and retinoschisis Detachment mechanisms, pneumatic retinopexy and scleral buckling

32 Chapter 32: Vitrectomy, Macular Surgery and Retinal Trauma

Vitrectomy and intraocular tamponades ERM, macular holes and PVR Retinal trauma, optic-disc pits and choroidal detachment

33 Chapter 33: Uveitis Classification and Non-Infectious Inflammation

SUN classification, grading and uveitis work-up Anterior and intermediate uveitis patterns HLA-B27, sarcoidosis, Behçet disease and VKH Posterior inflammatory patterns and immunomodulation

34 Chapter 34: Infectious Uveitis and Endophthalmitis

Toxoplasmosis and herpetic necrotizing retinitis Ocular syphilis and tuberculosis Immunosuppressed retinitis, toxocariasis and neuroretinitis Endophthalmitis diagnosis and treatment

35 Chapter 35: Optic Neuritis and Ischaemic Optic Neuropathy

Typical optic neuritis and ONTT NMOSD and MOGAD Arteritic optic neuropathy and GCA NAION and ischaemic neuropathy comparison

36 Chapter 36: Papilloedema, IIH and Afferent Localisation

Papilloedema recognition and Frisén grading IIH diagnosis and vision protection Disc drusen and pseudopapilloedema Afferent pathways and chiasmal localization

37 Chapter 37: Congenital, Inherited and Cortical Neuro-Ophthalmology

Cortical vision and higher visual syndromes Neuro-ophthalmic testing and congenital optic discs Inherited, compressive, infiltrative and nutritional optic neuropathies Transient visual loss, headache and neurological emergencies

38 Chapter 38: Central Motor Control and Cranial Nerve Palsies

Central ocular motor control and supranuclear disorders Third- and fourth-nerve palsies Sixth nerve, pontine gaze and cavernous sinus

39 Chapter 39: Myasthenia and Ocular Myopathy

Myasthenic ocular weakness Myasthenia testing and treatment Myopathy, CPEO and Kearns–Sayre syndrome

40 Chapter 40: Pupillary Pathways and Anisocoria

Pupillary pathways and afferent defects Horner syndrome and tonic pupil Light–near dissociation and pupil differentials

41 Chapter 41: Orbit, Thyroid Eye Disease and Ptosis Assessment

Orbital anatomy and thyroid eye disease Orbital infection and idiopathic inflammation Orbital masses, approaches and eye-removal procedures Lid anatomy and ptosis evaluation

42 Chapter 42: Lid Repair and Lacrimal Drainage

Ptosis repair, malposition and eyelid tumours Lash disorders, facial palsy and lid reconstruction Lacrimal drainage and epiphora testing Nasolacrimal obstruction, infection and DCR

43 Chapter 43: Lacrimal Gland Disease, Pathology and Intraocular Tumours

Lacrimal gland inflammation and tumours Ocular histology, specimen handling and special stains Immunophenotyping, molecular pathology and tumour genetics Uveal melanoma and retinoblastoma

44 Chapter 44: Lymphoma, Surface Tumours and Paraneoplastic Disease

Vitreoretinal lymphoma Surface tumours, uveal metastases and benign mimics Paraneoplastic retinopathy, treatment effects and counselling

45 Chapter 45: Ocular Trauma and Vascular Systemic Disease

Trauma terminology and prognostic scoring Chemical injury and surface preservation Open-globe emergency management Vascular, endocrine, pregnancy and renal eye disease

46 Chapter 46: Multisystem Disease and Ophthalmic Pharmacology

Immune, metabolic and multisystem ocular clues Phakomatoses and syndrome-specific surveillance Connective-tissue and metabolic ocular disease Drug delivery and systemic glaucoma effects

47 Chapter 47: Medication Toxicity, Professional Practice and Clinical Stations

Retinal and optic medication toxicity Prevention, consent and professional practice Directed clinical answers and station rehearsal

Optical and ultrasound biometry

Key Takeaways Explain This Topic AI

Biometry depends on accurate endpoints, fixation and device-specific calibration.

Dense media, posterior staphyloma and intraocular oil can produce measurement problems requiring cross-checks.

A branded instrument’s acquisition or total-keratometry features should not be attributed to every biometer.

Last updated: October 2026

Principles of Optical vs Ultrasound Biometry

Accurate determination of ocular dimensions—particularly axial length (AL), anterior chamber depth (ACD), and corneal curvature (K)—is the paramount determinant of refractive success following cataract surgery. A biometrical error of just 0.1 mm 0.1\text{ mm} 0.1 mm in axial length produces approximately 0.25 to 0.30 D 0.25\text{ to }0.30\text{ D} 0.25 to 0.30 D of refractive error at the spectacle plane in an average eye.

Optical Biometry Technologies

Optical biometry utilizes non-invasive, high-resolution interferometric principles to measure distance along the visual axis:

Partial Coherence Interferometry (PCI, e.g., Zeiss IOLMaster 500): Employs a dual-beam infrared semiconductor laser diode ( λ = 780 nm \lambda = 780\text{ nm} λ = 780 nm ) with a coherence length of approximately 160 μ m 160\,\mu\text{m} 160 μ m . It measures the optical path length from the anterior corneal vertex to the retinal pigment epithelium (RPE) . An internal regression algorithm calibrated against immersion ultrasound converts optical path length into geometric axial length.

Optical Low-Coherence Reflectometry (OLCR, e.g., Haag-Streit Lenstar LS900): Uses an 820 nm 820\text{ nm} 820 nm superluminescent diode to generate a complete axial profile in a single measurement sweep, capturing central corneal thickness (CCT), ACD, lens thickness (LT), and axial length.

Swept-source optical coherence tomography biometry: Long-wavelength swept-source systems improve acquisition through some dense cataracts, but failure can still occur. Features such as fixation checks, macular scans and measured total corneal power depend on the instrument and software. Do not attribute every feature of one branded device to all swept-source biometers; repeat inconsistent results and use an alternative method when necessary.

Ultrasound Biometry: Acoustic Physics & Media Velocities

Ultrasound biometry relies on piezoelectric transducers emitting high-frequency acoustic pulses ( 10 − 15 MHz 10-15\text{ MHz} 10 − 15 MHz ). Sound propagates through ocular media at velocities determined by physical tissue density and bulk compressibility according to the acoustic impedance formula: Z = ρ × v Z = \rho \times v Z = ρ × v

where Z Z Z is acoustic impedance, ρ \rho ρ is tissue density, and v v v is sound velocity. When acoustic waves strike an interface between two tissues of differing acoustic impedance (e.g., aqueous to anterior lens capsule, or vitreous to neurosensory retina), an echo is reflected back to the probe.

Ocular Medium / Material Acoustic Sound Velocity ( v v v ) Refractive Index ( n n n ) Clinical & Biometrical Significance

Cornea 1641 m/s 1641\text{ m/s} 1641 m/s 1.376 1.376 1.376 Dense collagen matrix; high acoustic speed.

Aqueous Humor 1532 m/s 1532\text{ m/s} 1532 m/s 1.336 1.336 1.336 Water-like fluid in anterior chamber.

Crystalline Lens (Normal phakic) 1641 m/s 1641\text{ m/s} 1641 m/s 1.406 1.406 1.406 (core) Densely packed crystallin proteins elevate velocity.

Vitreous Body 1532 m/s 1532\text{ m/s} 1532 m/s 1.336 1.336 1.336 Identical acoustic velocity to aqueous humor.

Average Phakic Eye Standard 1550 m/s 1550\text{ m/s} 1550 m/s N/A Weighted average calibration used by global ultrasound units.

Aphakic Eye Standard 1534 m/s 1534\text{ m/s} 1534 m/s N/A Adjusted downward due to absence of high-velocity lens.

PMMA Intraocular Lens 2718 m/s 2718\text{ m/s} 2718 m/s 1.492 1.492 1.492 Extremely high sound velocity; short transit time.

Hydrophobic Acrylic IOL 2120 m/s 2120\text{ m/s} 2120 m/s 1.47 − 1.55 1.47-1.55 1.47 − 1.55 Moderate-high velocity.

Silicone Oil (1000 cSt) 1049 m/s 1049\text{ m/s} 1049 m/s 1.403 1.403 1.403 Drastically slower acoustic velocity than vitreous.

Silicone Oil (5000 cSt) 980 m/s 980\text{ m/s} 980 m/s 1.405 1.405 1.405 Slowest ocular medium; profound transit time prolongation.

Optical versus Acoustic Measurement Landmarks

Optical Biometry: Measures from the anterior corneal vertex to the retinal pigment epithelium (RPE) because infrared light traverses the transparent sensory retina and reflects off the pigmented melanin layer.

Ultrasound Biometry: Measures from the anterior corneal vertex to the internal limiting membrane (ILM) of the retina, because the acoustic impedance change occurs between the liquid vitreous and the neurosensory retinal surface.

Device calibration : Optical and ultrasound devices detect different retinal interfaces, but reported lengths incorporate device-specific conversion/calibration. Do not add a universal retinal-thickness offset manually. Use the appropriate device settings and optimised lens constants.

Contact Applanation versus Immersion A-Scan

Contact Applanation A-Scan: The ultrasound probe is placed directly against the anesthetized cornea. Manual pressure mechanically indents the cornea, causing variable compression of the anterior chamber depth by 0.14 to 0.33 mm 0.14\text{ to }0.33\text{ mm} 0.14 to 0.33 mm . This artifactual shortening of the measured axial length causes the biometry formula to calculate an inappropriately higher IOL power, resulting in a disastrous postoperative myopic surprise .

Immersion A-Scan (Prager Shell): A small cylindrical plastic scleral shell filled with balanced salt solution is positioned over the eye. The probe is submerged in the fluid without touching the cornea. Corneal compression is completely eliminated, producing crisp, separate echoes for the corneal front and back surfaces, accurate ACD, and reproducible axial length.

Biometrical Pitfalls: Staphyloma & Silicone Oil

Posterior staphyloma: Ultrasound may measure an off-axis deepest point rather than the fovea. Check fixation and scan alignment, repeat inconsistent readings and use appropriate optical or image-guided ultrasound methods. No instrument guarantees the correct endpoint in every eye.

The Silicone Oil-Filled Eye:

Sound travels dramatically slower through silicone oil ( 980 − 1049 m/s 980-1049\text{ m/s} 980 − 1049 m/s ) than through normal vitreous ( 1532 m/s 1532\text{ m/s} 1532 m/s ). If an ultrasound biometer operates on the standard 1550 m/s 1550\text{ m/s} 1550 m/s phakic calibration, the prolonged transit time through silicone oil is falsely interpreted as a massive, artifactual elongation of the eye (frequently adding 3 to 6 mm to the measured AL).

If this artifactual measurement is used, an underpowered IOL is selected, producing a severe hyperopic surprise ( + 5.0 to + 10.0 D +5.0\text{ to }+10.0\text{ D} + 5.0 to + 10.0 D ). Clinicians must switch ultrasound machines to dedicated "silicone oil mode" or apply mathematical velocity correction: AL true = ACD + LT + ( VCD measured × v oil 1532 ) \text{AL}_{\text{true}} = \text{ACD} + \text{LT} + \left( \text{VCD}_{\text{measured}} \times \frac{v_{\text{oil}}}{1532} \right) AL true ​ = ACD + LT + ( VCD measured ​ × 1532 v oil ​ ​ )

Optical effect: Silicone oil changes the refractive-index difference at the posterior IOL surface. The shift depends on IOL shape, power, position and oil contact; use an oil-specific calculation rather than a fixed 2–3.5 D addition or a compulsory lens design.