Study guide
2.3 Compounding and Sterile Preparation
ExCPT Exam for the Certification of Pharmacy Technicians
Track your progress as you read
Finished sections get a check mark.
1 Introduction
About the ExCPT How to Use This Guide
2 Chapter 1: Role, Responsibilities, and Laws
1.1 Role and Scope of Practice 1.2 Controlled Substance Schedules 1.3 Federal Regulations 1.4 Pharmacy Settings and Professional Standards 1.5 Technician Support Roles, MTM, and Medical Terminology
3 Chapter 2: Dispensing Process
2.1 Prescription Intake and Interpretation 2.2 Pharmacy Calculations 2.3 Compounding and Sterile Preparation 2.4 Insurance, Billing, and Claims Processing 2.5 Inventory Management and Medication Safety
4 Chapter 3: Drugs and Drug Therapy
3.1 Drug Classifications and Naming Conventions 3.2 Cardiovascular and Anticoagulant Medications 3.3 Anti-infective, Analgesic, and CNS Medications 3.4 Endocrine, Respiratory Medications and Storage Requirements
5 Chapter 4: Medication and Patient Safety and Quality Assurance
4.1 Medication Error Prevention and High-Alert Safety 4.2 Adverse Event Reporting, REMS, and Continuous Quality Improvement
2.3 Compounding and Sterile Preparation
Key Takeaways Explain This Topic AI
USP <795> governs non-sterile compounding; USP <797> governs sterile compounding.
Beyond-use dates (BUDs) differ from expiration dates and are assigned by the compounder.
Aseptic technique requires proper hand hygiene, garbing, and working in a laminar airflow hood.
ISO Class 5 environment is required for sterile compounding in the primary engineering control.
Hazardous drug compounding follows USP <800> with additional safety requirements.
Last updated: October 2026
Quick Answer: Non-sterile compounding follows USP <795> while sterile compounding follows USP <797>. Sterile products require ISO Class 5 environment, proper aseptic technique, and appropriate beyond-use dating. USP <800> covers hazardous drug handling.
USP Compounding Chapters
- Chapter Coverage Examples
- USP <795> Non-sterile compounding Creams, ointments, capsules, oral liquids
- USP <797> Sterile compounding IV solutions, injections, ophthalmic preparations
- USP <800> Hazardous drug handling Chemotherapy, hormone preparations
- Non-Sterile Compounding (USP <795>)
- What Counts as Non-Sterile Compounding
The 2022 revision of USP <795> eliminated the old simple, moderate, and complex compounding categories. Reconstituting a manufactured product according to its labeling is not compounding under the chapter; reconstitution that departs from the labeling is.
- Equipment for Non-Sterile Compounding
- Class A prescription balance (sensitivity 6 mg)
- Graduated cylinders
- Mortar and pestle
- Ointment slab or parchment paper
- Spatulas (metal and plastic)
- Weighing boats or papers
- Compounding log and formula records
- Beyond-Use Dating for Non-Sterile Compounds
USP <795> (2022 revision), when there is no stability data:
- Type Maximum BUD (no stability data)
- Nonpreserved aqueous dosage forms 14 days (refrigerated)
- Preserved aqueous dosage forms 35 days
- Nonaqueous oral liquids 90 days
- Other nonaqueous dosage forms (e.g., capsules, ointments) 180 days
No BUD may exceed the shortest remaining expiration date of any commercially available starting component.
Important : Beyond-use date (BUD) is different from expiration date. BUD is assigned by the compounder; expiration date is from the manufacturer.
- Sterile Compounding (USP <797>)
- ISO Classifications
- ISO Class Max Particles (0.5 mcm) per m3 Use
- ISO Class 5 3,520 Primary engineering control (hood)
- ISO Class 7 352,000 Buffer area/clean room
- ISO Class 8 3,520,000 Ante area
- Primary Engineering Controls (PECs)
- Type Description Use
- Horizontal Laminar Airflow Hood (LAFW) HEPA-filtered air flows toward worker Non-hazardous sterile compounding
- Biological Safety Cabinet (BSC) Air exhausted through HEPA filter Hazardous drugs
Compounding Aseptic Isolator (CAI) Enclosed isolator with HEPA-filtered ISO Class 5 air Non-hazardous sterile compounding (sterile hazardous drugs use a BSC or CACI)
- Compounding Aseptic Containment Isolator (CACI) Enhanced containment Hazardous drugs
- Aseptic Technique Requirements
Proper Hand Hygiene:
- Remove jewelry and artificial nails
- Wash hands and forearms with soap and water for at least 30 seconds
- Apply alcohol-based hand rub before gloving
- Don sterile gloves, then apply sterile 70% IPA to them before compounding and regularly throughout
Example Garbing Order (USP <797> does not set one order; your facility's SOP does, in an order that reduces contamination):
- Shoe covers
- Head cover (hair cover)
- Face mask
- Hand washing
- Non-shedding gown
Sterile gloves (donned in a classified room or SCA; never donned or doffed inside the ISO Class 5 PEC with bare hands exposed)
Beyond-Use Dating for Sterile Compounds (CSPs)
Category 1 CSPs (12 Hours or Less at Room Temp):
- Storage BUD
- Room temperature 12 hours
- Refrigerated 24 hours
Category 2 CSPs (prepared in an ISO Class 5 PEC inside an ISO-classified anteroom and buffer room): the maximum BUD depends on how the CSP was made.
- Category 2 CSP Room temperature Refrigerated Frozen (-25 to -10 C)
- Aseptically processed, all sterile starting components, no sterility test 4 days 10 days 45 days
- Aseptically processed, any nonsterile starting component, no sterility test 1 day 4 days 45 days
- Aseptically processed, passed sterility testing 30 days 45 days 60 days
- Terminally sterilized, no sterility test 14 days 28 days 45 days
- Terminally sterilized, passed sterility testing 45 days 60 days 90 days
A shorter BUD applies when stability data call for it. Category 3 CSPs, made under extra quality requirements, may have longer BUDs.
- Clean Room Behavior Rules
- No food, drink, or gum
- No cosmetics or perfume
- Speak minimally
- Move slowly and deliberately
- Never cough or sneeze toward work area
- Keep hands away from face
- Work at least 6 inches inside the front edge of the hood (ASHP guidance)
- Never block HEPA filter airflow
- IV Preparation Basics
- Common IV Solutions
- Abbreviation Full Name Uses
- NS Normal Saline (0.9% NaCl) Most common, isotonic
- 1/2 NS Half Normal Saline (0.45% NaCl) Maintenance fluids
- D5W 5% Dextrose in Water Caloric supplementation
- D5NS 5% Dextrose in Normal Saline Fluid and calories
- LR Lactated Ringer's Resuscitation, surgery
- D5LR 5% Dextrose in LR Combination therapy
- IV Flow Rate Calculations
- Formula: gtt/min = (Volume x Drop Factor) / Time in minutes
- IV Set Type Drop Factor
- Microdrip 60 gtt/mL
- Macrodrip (standard) 10-20 gtt/mL
- Worked Example: IV Flow Rate
- Order: 1000 mL NS over 8 hours using 15 gtt/mL tubing
- Step 1: Convert hours to minutes
- 8 hours x 60 = 480 minutes
- Step 2: Apply formula
- gtt/min = (1000 mL x 15 gtt/mL) / 480 min
- gtt/min = 15,000 / 480 = 31.25 gtt/min (round to 31)
- Hazardous Drug Handling (USP <800>)
- Requirements for Hazardous Drugs
- Requirement Details
- Negative pressure room Prevents contamination spread
- Double gloving Chemotherapy-rated gloves
- Closed-system transfer devices For administration
- Dedicated equipment Do not share with non-hazardous
- Spill kit Readily available
- Medical surveillance For personnel exposure
- Categories of Hazardous Drugs
- Antineoplastic agents (chemotherapy)
- Hormones and hormone antagonists
- Some antivirals
- Immunosuppressants
- Bioengineered drugs
- USP Chapters That Govern Compounding
Three USP chapters define the standards the ExCPT tests. Know which chapter applies to which activity.
- USP Chapter Scope
- USP <795> Non-sterile compounding (creams, capsules, suspensions)
- USP <797> Sterile compounding (IV admixtures, ophthalmics, injectables)
- USP <800> Handling of hazardous drugs (chemotherapy, some hormones)
Exam Tip : If a question mentions a laminar flow hood, ISO-classified air, or aseptic technique, the governing chapter is USP <797>. If it mentions chemotherapy or a negative-pressure room, think USP <800>.
Primary Engineering Controls and Air Quality
Sterile compounding occurs inside primary engineering controls (PECs) . Air cleanliness is rated by ISO class, where a lower number is cleaner.
- Control Use
- Laminar airflow workbench (horizontal flow) Non-hazardous sterile products
- Biological safety cabinet (vertical flow) Hazardous sterile products
- Compounding aseptic isolator (CAI) Non-hazardous in a closed glovebox
- Compounding aseptic containment isolator (CACI) Hazardous in a closed, negative-pressure glovebox
The direct compounding area inside a PEC must meet ISO Class 5 . The buffer room is typically ISO Class 7 and the ante-room ISO Class 8.
Beyond-Use Dates (BUD)
A beyond-use date is the date after which a compounded preparation must not be used. It differs from the manufacturer expiration date on commercial stock. BUDs depend on the preparation type, storage temperature, and sterility.
- Preparation Typical BUD Driver
- Non-sterile (USP <795>) Water content, storage; assigned per published data
- Sterile (USP <797>) CSP category (1, 2 or 3) and storage temperature
- Repackaged unit dose Earlier of manufacturer expiration or guideline limit
Worked Example : A repackaged tablet has a manufacturer expiration of 18 months away, but the repackaging guideline caps the BUD at 6 months. The label must show the 6-month BUD because you always assign the earlier date.
Needles, Syringes, and Documentation
Sterile compounding also tests equipment knowledge. A higher needle gauge number means a thinner needle . Filter needles trap glass or rubber particles when drawing from an ampule. Every compounded or repackaged product requires documentation: ingredients, lot numbers, BUD, and the preparer's and checker's identities, retained per USP <795>/<797>.