Study guide

8.1 Fuel Tank Types: Rigid, Bladder & Integral (Wet Wing) Tanks

FAA Aviation Mechanic — Airframe AMA

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction & Exam Strategy

1.1 Exam Structure, Eligibility & 14 CFR Part 65 Requirements 1.2 Study Strategy, Blueprint Weighting & Core Formulas

2 Chapter 2: Metallic Structures & Sheet Metal Repair

2.1 Aluminum Alloys, Heat Treatment & Rivet Identification 2.2 Rivet Layout, Edge Distance, Spacing & Driving Standards 2.3 Sheet Metal Layout: Bend Allowance, Setback & Forming 2.4 Sheet Metal Inspection, Damage Evaluation & Flush/Lap Repairs

3 Chapter 3: Non-Metallic Structures: Composites, Wood, Fabric & Transparent Plastics

3.1 Advanced Composites: Fiber Types, Resin Matrices & Core Materials 3.2 Composite Damage Assessment, Repair Methods & Shop Safety 3.3 Aircraft Wood Structures: Defects, Allowable Repairs & Gluing 3.4 Aircraft Fabric Covering, Inspection & Doping/Finishing Processes 3.5 Transparent Plastics, Windows, Windshields & Cabin Interiors

4 Chapter 4: Welding & Structural Fasteners

4.1 Oxyacetylene & Electric Arc Welding Principles for Aviation 4.2 Tubular Steel Fuselage Inspection, Defect Types & Approved Repairs 4.3 Special Structural Fasteners, Blind Rivets & Precision Hardware

5 Chapter 5: Flight Controls, Assembly & Rigging

5.1 Primary and Secondary Flight Control Surfaces & Aerodynamics 5.2 Control Cables, Tensiometers & Temperature-Compensated Rigging 5.3 Turnbuckles, Cable Safetying, Pulleys & Fairleads 5.4 Control Surface Travel, Mass Balancing & Flutter Prevention

6 Chapter 6: Hydraulic & Pneumatic Power Systems

6.1 Hydraulic Fluids, Seal Materials & Contamination Control 6.2 Hydraulic Reservoirs, Power Pumps & Accumulators 6.3 Hydraulic Valves: Pressure, Flow & Directional Control 6.4 High-Pressure Pneumatic Systems, Air Compressors & Moisture Control

7 Chapter 7: Aircraft Landing Gear Systems

7.1 Oleo Shock Struts: Servicing, Air/Oil Charging & Metering Pins 7.2 Retraction Mechanisms, Down-Locks, Alignment & Torque Links 7.3 Aircraft Brakes, Multi-Disc Systems & Anti-Skid Operations 7.4 Aircraft Tires, Wheels, Bearings & Emergency Extension Systems

8 Chapter 8: Aircraft Fuel Systems

8.1 Fuel Tank Types: Rigid, Bladder & Integral (Wet Wing) Tanks 8.2 Fuel System Plumbing: Boost Pumps, Selector Valves & Filtration 8.3 Crossfeed, Fuel Jettison, Fuel Quantity Indication & Probes 8.4 Fuel System Maintenance, Defueling & Tank Confined-Space Safety

9 Chapter 9: Airframe Electrical Systems

9.1 AC & DC Power Generation: Alternators, Inverters & TRUs 9.2 Aircraft Electrical Distribution, Bus Architecture & Circuit Protection 9.3 Aircraft Wire Selection (MIL-W-5086 / MIL-W-22759), Sizing & Bundling 9.4 Bonding, Grounding, Static Dischargers & Electrical Troubleshooting

10 Chapter 10: Cabin Atmosphere & Environmental Control

10.1 Vapor-Cycle & Air-Cycle Machine (ACM) Refrigeration Systems 10.2 Cabin Pressurization: Outflow Valves, Safety Valves & Regulators 10.3 Heating Systems: Combustion Heaters, Exhaust Muffs & Bleed Air 10.4 Aircraft Oxygen Systems: Continuous-Flow, Diluter-Demand & Generators

11 Chapter 11: Aircraft Instrument Systems

11.1 Pitot-Static Systems: Altimeter, VSI, Airspeed & Error Diagnosis 11.2 Gyroscopic Flight Instruments: Rigidity, Precession & Power Sources 11.3 Engine & System Instruments: Bourdon Tubes, Synchros & EICAS 11.4 Instrument Installation, Magnetic Compass Swing & Regulatory Inspections

12 Chapter 12: Communication, Navigation & Warning Systems

12.1 VHF/HF Communications, Antennas & Coaxial Cable Installation 12.2 Navigation Systems: VOR, ILS, DME, ADF, GPS & Weather Radar 12.3 Transponders, Altitude Encoders & Emergency Locator Transmitters 12.4 Position & Warning Systems: Landing Gear Horns, Stall & Warning

13 Chapter 13: Ice, Rain & Fire Protection Systems

13.1 Ice Detection, Pneumatic Deice Boots & Electrothermal Systems 13.2 Wing & Cowl Thermal Bleed-Air Anti-Ice Systems & Rain Removal 13.3 Fire & Smoke Detection: Spot Detectors, Continuous Loops & Optical Sensors 13.4 Fire Extinguishing Systems: HRD Containers, Squibs & Two-Shot Architecture

14 Chapter 14: Airframe Inspection & Maintenance Regulations

14.1 14 CFR Part 43 Appendix D: Scope of 100-Hour & Annual Inspections 14.2 Airworthiness Directives (ADs), Service Bulletins & Major Alterations 14.3 FAA Form 337 Execution, Maintenance Record Entries & Logbook Rules 14.4 Airframe Corrosion Identification, Treatment, Chemical Conversion & NDT

15 Chapter 15: Rotorcraft Fundamentals

15.1 Rotorcraft Aerodynamics, Rotor System Classifications & Flight Controls 15.2 Rotor Blades, Transmissions, Drive Systems & Skid Landing Gear Inspection 15.3 Rotor Track & Balance, Vibration Diagnosis & Helicopter Ground Safety

16 Chapter 16: Water & Waste Systems

16.1 Potable Water Systems: Components, Operation, Servicing & Sanitizing 16.2 Lavatory Waste Systems: Vacuum & Recirculating Types, Servicing & Safety

8.1 Fuel Tank Types: Rigid, Bladder & Integral (Wet Wing) Tanks

Key Takeaways Explain This Topic AI

Aircraft fuel storage systems are classified into three primary construction types: rigid removable tanks (welded aluminum 3003/5052), flexible bladder cells (synthetic rubber/neoprene), and integral structural tanks ('wet wings' sealed with polysulfide elastomers).

14 CFR § 23.969 and § 25.969 mandate an expansion space of not less than 2% of total tank capacity (or minimum 1 gallon) that cannot be inadvertently filled with fuel in normal ground attitudes.

Bladder fuel cells are supported by the surrounding airframe cavity using button snaps and cord lacing; if drained and stored dry, they must be coated with clean engine oil or fuel to prevent drying, hardening, and cracking.

Internal tank baffles with one-way flapper valves prevent rapid fuel sloshing during pitch, roll, and yaw maneuvers, maintaining continuous fuel submersion over pump inlet pick-ups.

Integral tank fuel leaks are classified into four precise categories per FAA/OEM maintenance standards: Slow Seep (<3/4 in), Seep (3/4 in to 1.5 in), Heavy Seep (1.5 in to 3 in), and Running Leak (>3 in or dripping/running stream), with running leaks strictly grounding the aircraft.

Last updated: August 2026

8.1 Fuel Tank Types: Rigid, Bladder & Integral (Wet Wing) Tanks

FAA Airframe Exam Focus: Aircraft fuel storage systems must safely store volatile aviation fuels under extreme flight loads, thermal variations, and vibration regimes without leaking, deforming, or starving engines of fuel. Aviation Maintenance Technicians (AMTs) must master the construction, installation, inspection, and repair of rigid removable tanks, flexible bladder fuel cells, and integral structural ('wet wing') fuel tanks, as well as OEM leak classifications per FAA standards.

1. Aircraft Fuel Tank Classifications & Design Principles

Aircraft fuel storage systems are engineered to carry the maximum usable fuel volume with minimum structural weight while maintaining structural integrity during gust loads, hard landings, and emergency landing decelerations. Modern civil and transport aircraft utilize three distinct categories of fuel tanks: ┌─────────────────────────────────────────────────────────────────────────────┐

  • │ AIRCRAFT FUEL TANK CLASSIFICATIONS │
  • ├──────────────────────┬──────────────────────┬───────────────────────────────┤
  • │ Rigid Removable │ Flexible Bladder │ Integral Tank │
  • │ Metal Tanks │ Fuel Cells │ ('Wet Wing') │
  • ├──────────────────────┼──────────────────────┼───────────────────────────────┤
  • │ • Welded 3003 / 5052 │ • Reinforced Rubber │ • Sealed Wing Structure │
  • │ • Padded strap mount │ • Button snap/lacing │ • Polysulfide Sealants │
  • │ • Expansion space 2% │ • Oil soak when dry │ • Lowest airframe weight │
  • │ • GA & light twins │ • Warbirds, piston twin│ • High-performance transport │
  • └──────────────────────┴──────────────────────┴───────────────────────────────┘
  • Core Regulatory Design Requirements (14 CFR Parts 23 & 25)

Federal Aviation Regulations establish strict design and safety criteria for all aircraft fuel tanks:

Expansion Space Requirement (14 CFR § 23.969 / § 25.969): Each fuel tank must have an expansion space of not less than 2 percent (2%) of the tank capacity, and it must be impossible to inadvertently fill the expansion space when the aircraft is parked in its normal ground attitude.

Fuel Sump & Low-Point Drainage (14 CFR § 23.971 / § 25.971): Each tank must feature a designated low-point sediment sump with an easily accessible, lockable quick-drain valve capable of collecting and discharging water and solid sediment in all normal flight and ground attitudes.

Pressure Proof Testing:

Conventional rigid and integral metal tanks must withstand an internal test pressure of at least 3.5 psi 3.5\text{ psi} 3.5 psi (or maximum pressure developed during operations, whichever is greater) without leaking or permanent deformation.

Non-metallic flexible bladder cells must withstand a minimum internal proof pressure of 2.0 psi 2.0\text{ psi} 2.0 psi .

2. Rigid Removable Fuel Tanks

Rigid tanks are separate, self-contained fuel containers fabricated from welded sheet metal or composite materials. They are installed in dedicated wing cavities, fuselage bays, or nacelle structures and can be unbolted and removed for repair or replacement. RIGID TANK MOUNTING & BAFFLING

  • Padded Hold-Down Strap (Chafing Felt / Rubber)
  • │
  • ▼
  • ┌──────────────────┴──────────────────┐
  • │ ┌───┐ ┌───┐ ┌───┐ │
  • │ │ │ Internal │ │ Flapper│ │ │ ◄── 2% Expansion Space
  • │ │ B │ Slosh │ B │ Check │ B │ │
  • │ │ A │ Baffle │ A │ Valve │ A │ │
  • Fuel ──┼─┤ F ├────────────┤ F ├──► ───┤ F ├─┼──► Engine Feed Outlet
  • Inlet │ │ L │ │ L │ │ L │ │
  • │ │ E │ │ E │ │ E │ │
  • │ └───┘ └───┘ └───┘ │
  • └──────────────────┬──────────────────┘
  • │
  • ▼
  • Low-Point Water Sump & Drain Valve
  • Material Selection & Fabrication

Aluminum Alloys: Most rigid tanks are fabricated from 3003-H14 (aluminum-manganese alloy) or 5052-H32 (aluminum-magnesium alloy). These alloys feature superior ductility, excellent weldability (via TIG/GTAW or gas welding), and high corrosion resistance in the presence of aviation fuels.

Internal Baffling: Rigid tanks contain internal vertical baffle plates riveted or spot-welded to the tank walls. Baffles divide the tank into interconnected compartments with calibrated flow holes and spring-loaded or rubber flapper check valves . The flapper valves allow fuel to migrate inward toward the fuel pump pick-up or sump during uncoordinated turns or climbs, but prevent fuel from surging away from the pick-up during maneuvers, preventing pump cavitation and engine fuel starvation.

Mounting & Chafing Protection

Rigid tanks are supported on structural cradles or suspended by padded steel hold-down straps. To prevent metal-to-metal contact, fretting, and galvanic corrosion:

Padded straps must be lined with chafing strips made of heavy felt, synthetic rubber (neoprene), or specialized leather.

Precaution: If leather is used, it must be treated to remove tanning acids, and felt liners must be coated with non-hygroscopic waterproof compound to prevent water retention against the aluminum tank skin.

3. Flexible Bladder Fuel Cells

Flexible bladder tanks (fuel cells) are reinforced elastomeric bags installed inside a tailored wing or fuselage cavity. Because the bladder cell is not rigid, the surrounding aircraft structure supports the hydrostatic weight of the fuel. BLADDER CELL CAVITY INSTALLATION

  • Airframe Wing Upper Skin / Rib Structure
  • ┌────────────────────────────────────────────────────────┐
  • │ ○ ○ ○ ○ │ ◄── Snap Buttons
  • │ ║ ║ ║ ║ │ & Cord Lacing
  • │ ┌─╨─────────────╨─────────────╨─────────────╨────────┐ │
  • │ │ │ │
  • │ │ Flexible Synthetic Rubber Bladder Cell │ │
  • │ │ │ │
  • │ └─╥─────────────╥─────────────╥─────────────╥────────┘ │
  • │ ║ ║ ║ ║ │
  • │ ○ ○ ○ ○ │
  • └────────────────────────────────────────────────────────┘
  • Wing Lower Skin / Support Bay (Smooth, Cleaned, & Taped)
  • Construction & Attachment

Materials: Fabricated from multiple plies of high-strength nylon or Dacron fabric impregnated and vulcanized with synthetic rubber, such as nitrile (Buna-N) , neoprene , or polyurethane . The interior layer resists fuel degradation, while the exterior layer resists environmental abrasion.

Positive Retention: The bladder is held in place against the cavity walls using positive mechanical fasteners , including brass snap buttons, eyelet lacing cords, and internal molded rubber ribs attached to airframe stringers. This prevents the empty bladder from collapsing or shifting during flight maneuvers.

Cavity Preparation: The structural airframe bay must be thoroughly vacuumed and inspected. All rivet tails, burrs, and sharp sheet metal edges must be covered with cushioning anti-chafing tape (such as high-density polyethylene or vinyl tape) to prevent puncturing the cell fabric.

Maintenance & Preservation of Bladder Cells

Wrinkle Inspection: During installation, the bladder must be pulled completely smooth. Any wrinkles along the bottom floor can trap water and solid contaminants, preventing them from reaching the low-point sump drain and initiating severe local biological corrosion.

Drying Out Prevention (Storage/Maintenance Rule): If an aircraft with bladder tanks is defueled and left empty for more than a few days, the synthetic rubber will dry out, harden, shrink, and develop severe micro-cracks.

Preservation Protocol: Technicians must wipe or spray the interior cell walls with a light film of clean engine lubricating oil (MIL-PRF-6082 / SAE 50) or fuel to keep the elastomeric polymers pliable.

Post-Storage Soaking: After prolonged dry storage, bladder cells must be soaked with fuel for at least 24 to 48 hours prior to flight to allow the elastomers to swell back to their nominal sealing dimensions.

4. Integral Fuel Tanks ('Wet Wing' Construction)

An integral fuel tank is a sealed structural portion of the aircraft wing or fuselage designed to carry fuel directly against the primary aircraft skin. In modern transport category airliners (e.g., Boeing 737/777/787, Airbus A320/A350) and high-performance business jets, the wing structure between the front spar, rear spar, upper skin, and lower skin forms a continuous sealed structural fuel reservoir known as a 'wet wing' . INTEGRAL 'WET WING' STRUCTURE

  • Upper Wing Skin (Compression Panel)
  • ┌─────────────────────────────────────────────────────────────────┐
  • │ ▲ Sealant Fillet Bead ▲ Fastener Cap Sealant Dome │
  • │ │ │ │
  • ┌─┴──┴─────────┐ ┌──┴───────────┐ │
  • │ FRONT SPAR │ SEALED WING │ RIB BAFFLE │ REAR SPAR │
  • │ (Fuel Wall) │ FUEL CAVITY │ (Flow Holes) │ (Fuel Wall) │
  • │ │ │ │ │
  • └─┬──┬─────────┘ └──┬───────────┘ ┌─┴─┐
  • │ │ │ │ │
  • └──┴────────────────────────────────┴───────────────────────────┴───┘
  • Lower Wing Skin (Tension Panel)
  • Advantages of Integral Tanks

Maximum Fuel Volume: Utilizes every cubic inch of internal wing cavity space without the volume penalty of tank walls or bladder liners.

Weight Savings: Eliminates the physical weight of separate tank structures, mounting cradles, and retaining straps, resulting in superior payload-range performance.

Structural Simplicity: Reduces parts count and allows direct structural load sharing between fuel hydrostatic mass and wing bending relief in flight.

Sealing Technology & Materials

Integral tanks rely on advanced elastomeric sealants that maintain elasticity from − 65 ∘ F -65^\circ\text{F} − 6 5 ∘ F ( − 54 ∘ C -54^\circ\text{C} − 5 4 ∘ C ) to + 250 ∘ F +250^\circ\text{F} + 25 0 ∘ F ( + 121 ∘ C +121^\circ\text{C} + 12 1 ∘ C ) while resisting constant exposure to Jet-A, JP-8, and microbial acids.

Sealant Type Chemical Specification Characteristics & Application

Polysulfide (Class A) MIL-S-8802 Class A / AMS-S-8802 Low-viscosity, brushable liquid sealant. Used for brush-coating fastener patterns and surface priming. Application life: 0.5 to 2 hours.

Polysulfide (Class B) MIL-S-8802 Class B / AMS-S-8802 High-viscosity, non-sag thixotropic paste applied with extrusion guns. Used for structural fillet seals along spar-to-skin joints and fastener cap sealing . Application life: 1/2 to 4 hours.

Polythioether AMS 3277 / PR-1828 Rapid-curing, low-density fluorosilicone-modified polythioether. Exceptional resistance to hydrocarbon fuels and high temperatures.

Fluorosilicone MIL-S-87102 High-temperature resistant sealant used in engine nacelle fuel bays and Mach 2+ aerodynamic heating zones.

Surface Preparation & Sealant Application Steps

Degreasing & Cleaning: Structural surfaces must be chemically cleaned using solvent wipes (methyl ethyl ketone [MEK], isopropyl alcohol [IPA], or toluene) using the two-cloth cleaning method (one wet cloth to dissolve contaminants, immediately followed by a clean, dry, lint-free cloth to lift residue before solvent evaporates).

Chemical Conversion (Alodine): Bare aluminum must be chromate conversion coated (MIL-DTL-5541) to inhibit corrosion and provide a chemical anchor for sealants.

Adhesion Promoter: Apply a thin, uniform coat of adhesion promoter (silane-based primer) and allow it to dry for 30 minutes before applying sealant.

Fillet Sealing: Extrude a continuous triangular fillet bead ( 1 / 4 in 1/4\text{ in} 1/4 in to 3 / 8 in 3/8\text{ in} 3/8 in width) over all internal structural joints, smoothing with a spatulating tool to eliminate air voids and fish-eyes.

5. Integral Fuel Tank Leak Classification Standards

Fuel leaks in integral wing tanks are evaluated per strict FAA Advisory Circular (AC 43.13-1B) and OEM Structural Repair Manual (SRM) standards. Leaks are measured by wiping the outer skin completely dry, dusting the area with talcum powder or red dye developer, and observing the rate and diameter of fuel re-wetting after a standard dwell time (typically 30 minutes to 4 hours depending on OEM AMM specifications). FUEL LEAK CLASSIFICATION SPECTRUM

  • Slow Seep Seep Heavy Seep Running Leak
  • (0 to 3/4") (3/4" to 1-1/2") (1-1/2" to 3") (> 3" or Drip)
  • ┌─────────┐ ┌─────────┐ ┌─────────┐ ┌─────────┐
  • │ ┌───┐ │ │ ┌─────┐ │ │┌───────┐│ │┌───────┐│
  • │ │ • │ │ │ │ • │ │ ││ • ││ ││ • • • ││ ──► ACTIVE
  • │ └───┘ │ │ └─────┘ │ │└───────┘│ ││ 💧 💧 ││ DRIPPING
  • └─────────┘ └─────────┘ └─────────┘ └─────────┘
  • AIRWORTHY AIRWORTHY RESTRICTED UN-AIRWORTHY
  • (Monitor) (Record & Log) (SRM Limits) (GROUND AIRCRAFT)
  • Comprehensive FAA / OEM Leak Classification Matrix

Leak Category Wetted Area Diameter Physical Visual Characteristics Airworthiness Action & Dispatch Status

1. Slow Seep (Stain) Up to 3 / 4 inch 3/4\text{ inch} 3/4 inch ( 19 mm 19\text{ mm} 19 mm ) diameter Fuel wets surface around fastener or seam; evaporates rapidly. Does not run or drip. Airworthy. Permitted for flight. Re-inspect at next scheduled maintenance check; record location in aircraft logbook.

2. Seep Greater than 3 / 4 inch 3/4\text{ inch} 3/4 inch up to 1 1 2 inches 1\frac{1}{2}\text{ inches} 1 2 1 ​ inches ( 38 mm 38\text{ mm} 38 mm ) Visible fuel wetness around fastener or structural seam. Does not form active droplets or running streams. Airworthy. Aircraft may remain in revenue service. Must be monitored at regular daily/weekly transit checks.

3. Heavy Seep Greater than 1 1 2 inches 1\frac{1}{2}\text{ inches} 1 2 1 ​ inches up to 3 inches 3\text{ inches} 3 inches ( 76 mm 76\text{ mm} 76 mm ) Surface is wet with fuel; may form an occasional hanging droplet, but fuel does NOT actively run or drip continuously. Flight Restricted / Conditional. Permitted ONLY if located in non-critical exterior wing zones (open airflow) and strictly within SRM structural limits. Prohibited in enclosed fuselage, engine nacelle, or electrical bays.

4. Running Leak Greater than 3 inches 3\text{ inches} 3 inches ( 76 mm 76\text{ mm} 76 mm ) or any active dripping Fuel actively runs across surface in a continuous wet stream or drips at a measurable drop rate. UN-AIRWORTHY. Aircraft is GROUNDED IMMEDIATELY . Must be defueled, purged, opened, and structural sealant repaired before further flight.

6. Fuel Tank Venting & Sump Draining Systems

Aircraft fuel tanks must be vented to atmosphere to prevent severe structural damage and ensure continuous fuel delivery under all operating conditions.

1. Vent System Functions

Atmospheric Pressure Equalization: As fuel is consumed by engines ( 100 to 10 , 000 + lbs/hr 100\text{ to }10,000+\text{ lbs/hr} 100 to 10 , 000 + lbs/hr ), incoming atmospheric air must replace the liquid volume. Without venting, a powerful internal vacuum would develop, starving the engine-driven fuel pumps and causing the thin aluminum wing skin or bladder cell to collapse inward.

Thermal Expansion Relief: Fuel expands significantly when cold fuel ( − 40 ∘ F -40^\circ\text{F} − 4 0 ∘ F ) in wing tanks warms up on a hot tarmac ( + 110 ∘ F +110^\circ\text{F} + 11 0 ∘ F ). Vent tubes route expanding vapors and fuel into an expansion space or surge tank.

Climb & Descent Pressure Compensation: Rapid climbs cause tank air to expand (vented overboard); rapid descents introduce higher ambient pressure into the tank, preventing structural implosion. WING VENT & NACA SCOOP SYSTEM

  • Positive Ram Air Flow ──►
  • ┌────────────────────────┐
  • │ NACA VENT SCOOP │
  • │ (Slight Positive Head)│
  • └───────────┬────────────┘
  • │
  • Vent Line │ Positive Pressure
  • ┌────────────────────────────────────┴───────────────────────────┐
  • │ EXPANSION SPACE (2% Minimum) │
  • │ │
  • │ ~~~~~~~~~~~~~~~~~~~~~~~~~ FUEL LEVEL ~~~~~~~~~~~~~~~~~~~~~~~~~ │
  • │ │
  • │ ┌──────────┐ │
  • │ │ FLAME │ │
  • │ │ ARRESTOR │ │
  • │ └────┬─────┘ │
  • │ WING FUEL TANK │ │
  • └───────────────────────────────────────────────────────┼────────┘
  • │
  • Surge Tank Vent
  • 2. NACA Vents & Positive Pressurization

Transport aircraft utilize NACA submerged vent scoops flush-mounted on the underside of the outer wing panel. The aerodynamic profile of the NACA duct forces ram air into the vent manifold during flight, generating a slight positive head pressure ( 0.5 to 2.0 psi 0.5\text{ to }2.0\text{ psi} 0.5 to 2.0 psi ) inside the fuel tanks. This positive pressure aids fuel flow into the boost pumps and significantly suppresses fuel boiling (vapor lock) at high cruise altitudes.

Flame Arrestors: Vent outlets incorporate metallic mesh flame arrestors to prevent external lightning strikes or ground fires from propagating into the fuel vapor space.