Study guide
5.3 Turnbuckles, Cable Safetying, Pulleys & Fairleads
FAA Aviation Mechanic — Airframe AMA
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & Exam Strategy
1.1 Exam Structure, Eligibility & 14 CFR Part 65 Requirements 1.2 Study Strategy, Blueprint Weighting & Core Formulas
2 Chapter 2: Metallic Structures & Sheet Metal Repair
2.1 Aluminum Alloys, Heat Treatment & Rivet Identification 2.2 Rivet Layout, Edge Distance, Spacing & Driving Standards 2.3 Sheet Metal Layout: Bend Allowance, Setback & Forming 2.4 Sheet Metal Inspection, Damage Evaluation & Flush/Lap Repairs
3 Chapter 3: Non-Metallic Structures: Composites, Wood, Fabric & Transparent Plastics
3.1 Advanced Composites: Fiber Types, Resin Matrices & Core Materials 3.2 Composite Damage Assessment, Repair Methods & Shop Safety 3.3 Aircraft Wood Structures: Defects, Allowable Repairs & Gluing 3.4 Aircraft Fabric Covering, Inspection & Doping/Finishing Processes 3.5 Transparent Plastics, Windows, Windshields & Cabin Interiors
4 Chapter 4: Welding & Structural Fasteners
4.1 Oxyacetylene & Electric Arc Welding Principles for Aviation 4.2 Tubular Steel Fuselage Inspection, Defect Types & Approved Repairs 4.3 Special Structural Fasteners, Blind Rivets & Precision Hardware
5 Chapter 5: Flight Controls, Assembly & Rigging
5.1 Primary and Secondary Flight Control Surfaces & Aerodynamics 5.2 Control Cables, Tensiometers & Temperature-Compensated Rigging 5.3 Turnbuckles, Cable Safetying, Pulleys & Fairleads 5.4 Control Surface Travel, Mass Balancing & Flutter Prevention
6 Chapter 6: Hydraulic & Pneumatic Power Systems
6.1 Hydraulic Fluids, Seal Materials & Contamination Control 6.2 Hydraulic Reservoirs, Power Pumps & Accumulators 6.3 Hydraulic Valves: Pressure, Flow & Directional Control 6.4 High-Pressure Pneumatic Systems, Air Compressors & Moisture Control
7 Chapter 7: Aircraft Landing Gear Systems
7.1 Oleo Shock Struts: Servicing, Air/Oil Charging & Metering Pins 7.2 Retraction Mechanisms, Down-Locks, Alignment & Torque Links 7.3 Aircraft Brakes, Multi-Disc Systems & Anti-Skid Operations 7.4 Aircraft Tires, Wheels, Bearings & Emergency Extension Systems
8 Chapter 8: Aircraft Fuel Systems
8.1 Fuel Tank Types: Rigid, Bladder & Integral (Wet Wing) Tanks 8.2 Fuel System Plumbing: Boost Pumps, Selector Valves & Filtration 8.3 Crossfeed, Fuel Jettison, Fuel Quantity Indication & Probes 8.4 Fuel System Maintenance, Defueling & Tank Confined-Space Safety
9 Chapter 9: Airframe Electrical Systems
9.1 AC & DC Power Generation: Alternators, Inverters & TRUs 9.2 Aircraft Electrical Distribution, Bus Architecture & Circuit Protection 9.3 Aircraft Wire Selection (MIL-W-5086 / MIL-W-22759), Sizing & Bundling 9.4 Bonding, Grounding, Static Dischargers & Electrical Troubleshooting
10 Chapter 10: Cabin Atmosphere & Environmental Control
10.1 Vapor-Cycle & Air-Cycle Machine (ACM) Refrigeration Systems 10.2 Cabin Pressurization: Outflow Valves, Safety Valves & Regulators 10.3 Heating Systems: Combustion Heaters, Exhaust Muffs & Bleed Air 10.4 Aircraft Oxygen Systems: Continuous-Flow, Diluter-Demand & Generators
11 Chapter 11: Aircraft Instrument Systems
11.1 Pitot-Static Systems: Altimeter, VSI, Airspeed & Error Diagnosis 11.2 Gyroscopic Flight Instruments: Rigidity, Precession & Power Sources 11.3 Engine & System Instruments: Bourdon Tubes, Synchros & EICAS 11.4 Instrument Installation, Magnetic Compass Swing & Regulatory Inspections
12 Chapter 12: Communication, Navigation & Warning Systems
12.1 VHF/HF Communications, Antennas & Coaxial Cable Installation 12.2 Navigation Systems: VOR, ILS, DME, ADF, GPS & Weather Radar 12.3 Transponders, Altitude Encoders & Emergency Locator Transmitters 12.4 Position & Warning Systems: Landing Gear Horns, Stall & Warning
13 Chapter 13: Ice, Rain & Fire Protection Systems
13.1 Ice Detection, Pneumatic Deice Boots & Electrothermal Systems 13.2 Wing & Cowl Thermal Bleed-Air Anti-Ice Systems & Rain Removal 13.3 Fire & Smoke Detection: Spot Detectors, Continuous Loops & Optical Sensors 13.4 Fire Extinguishing Systems: HRD Containers, Squibs & Two-Shot Architecture
14 Chapter 14: Airframe Inspection & Maintenance Regulations
14.1 14 CFR Part 43 Appendix D: Scope of 100-Hour & Annual Inspections 14.2 Airworthiness Directives (ADs), Service Bulletins & Major Alterations 14.3 FAA Form 337 Execution, Maintenance Record Entries & Logbook Rules 14.4 Airframe Corrosion Identification, Treatment, Chemical Conversion & NDT
15 Chapter 15: Rotorcraft Fundamentals
15.1 Rotorcraft Aerodynamics, Rotor System Classifications & Flight Controls 15.2 Rotor Blades, Transmissions, Drive Systems & Skid Landing Gear Inspection 15.3 Rotor Track & Balance, Vibration Diagnosis & Helicopter Ground Safety
16 Chapter 16: Water & Waste Systems
16.1 Potable Water Systems: Components, Operation, Servicing & Sanitizing 16.2 Lavatory Waste Systems: Vacuum & Recirculating Types, Servicing & Safety
5.3 Turnbuckles, Cable Safetying, Pulleys & Fairleads
Key Takeaways Explain This Topic AI
Turnbuckles adjust cable length and rigging tension; they must be inspected to ensure no more than three (3) threads are exposed outside either end of the brass barrel after final rigging.
Turnbuckle safetying requires either the double-wrap spiral method (minimum 4 wraps around terminal shanks using MS20995 wire), single-wrap method for small cables, or NAS1756 clip-locking devices.
Control pulleys must be inspected for groove wear, flat spots, and free rotation; cable guards must be installed, and cable-to-pulley misalignment must not exceed 2 degrees.
Fairleads guide cables through bulkheads without touching structure; maximum allowable cable deflection angle by a fairlead is 3 degrees.
Cable swaged terminal integrity is inspected using a micrometer for MS cold-flow terminals (checking outer diameter) or a Go/No-Go slot gauge for copper Nicopress oval sleeves.
Last updated: August 2026
Turnbuckles, Cable Safetying, Pulleys & Fairleads
FAA Airframe Exam Focus: Safe flight control operation depends upon the mechanical integrity of turnbuckles, safety wire methods, pulleys, fairleads, and swaged cable terminations. Technicians must know the exact thread exposure limits for turnbuckles, the wrap count rules for MS20995 safety wire, pulley misalignment limits ( 2 ∘ 2^\circ 2 ∘ ), fairlead deflection limits ( 3 ∘ 3^\circ 3 ∘ ), and the dimensional verification of swaged fittings.
1. Turnbuckle Anatomy, Inspection & Thread Exposure Limits
A turnbuckle is a mechanical cable coupling assembly used to adjust cable tension and flight control surface neutral alignment. TURNBUCKLE ASSEMBLY & THREAD EXPOSURE LIMIT:
- Left-Hand Terminal Shank Brass Barrel (MS21251) Right-Hand Terminal Shank
- (Groove / Knurl Marker)
- ┌───┐ ┌──────────────┐ ┌───┐
- ══════╡ ╞═══╤═══════════════════╡ ╞═══════════════════╤═══╡ ╞══════
- └───┘ │ │ │ │ └───┘
- ▲ └──────────────┘ ▲
- Max 3 Exposed Threads Max 3 Exposed Threads
- Turnbuckle Anatomy & Thread Identification
Barrel: A central threaded sleeve (typically manufactured from brass alloy per MS21251 or aluminum bronze) featuring internal right-hand threads at one end and left-hand threads at the opposite end .
End Fitting Identification: The left-hand threaded end of the barrel is marked with an annular groove or raised knurled ring machined around its exterior circumference. Threaded terminal ends include swaged cable studs, fork ends (MS21252), eye ends (MS21253), or pin eye ends.
Operation: Rotating the barrel in one direction pulls both terminal ends inward simultaneously, increasing cable tension; rotating the opposite direction backs them out, decreasing tension.
The 3-Thread Exposure Inspection Rule (AC 43.13-1B)
Following final cable tension and travel rigging, turnbuckles must be visually and physically inspected to ensure that:
Maximum Exposed Threads: No more than three (3) full threads are exposed outside the barrel on either side of the turnbuckle.
Minimum Engagement: If more than 3 threads are visible, the terminal shank is insufficiently engaged inside the barrel, risking catastrophic thread shear failure under structural flight loads.
Full Internal Engagement: No threads inside the barrel may remain unengaged beyond the internal relief cavity.
2. Turnbuckle Safetying Methods: Wire Wrapping & Locking Clips
Once rigged, turnbuckles must be positively secured against vibration-induced rotation using safety wire (MS20995) or approved locking clips (NAS1756). DOUBLE-WRAP SPIRAL SAFETYING METHOD (AC 43.13-1B):
- Barrel Center Hole
- │
- 4 Wraps ▼ Spiral in Opposite Directions 4 Wraps
- ┌───────┐ ┌─────────┐ ┌─────────────────────────────┐ ┌───────┐
- ══════╡ ▓▓▓▓ ╞═══╡ ○ ╞═══╡ ╞═══╡ ▓▓▓▓ ╞══════
- └───────┘ └─────────┘ └─────────────────────────────┘ └───────┘
- Terminal Shank Terminal Shank
- Safety Wiring Methods Comparison (AC 43.13-1B, Chapter 7)
Method Cable Size Applicability Safety Wire Spec & Size Wrapping Architecture Terminal Shank Wraps
Double-Wrap Spiral (Standard / Preferred) All cable sizes ( 1 / 16 " 1/16" 1/16" to 1 / 4 " 1/4" 1/4" ) MS20995-C32 ( 0.032 " 0.032" 0.032" ) for cables ≤ 1 / 8 " \le 1/8" ≤ 1/8" ; MS20995-C40 ( 0.040 " 0.040" 0.040" ) for cables > 1 / 8 " > 1/8" > 1/8" Two separate safety wires passed through center hole, spiraled in opposite directions around barrel halves, through terminal eyes. Minimum 4 full turns tightly wrapped around shank; pigtail trimmed to 1 / 4 " – 1 / 2 " 1/4"\text{--}1/2" 1/4" – 1/2" ( 3 – 6 3\text{--}6 3 – 6 twists).
Single-Wrap Spiral Permitted ONLY on cables < 1 / 8 " <1/8" < 1/8" diameter MS20995-C40 ( 0.040 " 0.040" 0.040" wire) Single wire passed through center barrel hole, spiraled along barrel toward each terminal eye in opposite directions. Minimum 4 full turns around shank.
Double-Wrap Parallel All cable sizes MS20995-C32 or C40 Two wires passed through barrel hole, run straight along barrel flats without spiraling, then wrapped. Minimum 4 full turns around shank.
Clip-Locking Turnbuckles (NAS1756 / MS21251 / MS21255)
Modern aircraft frequently utilize clip-locking turnbuckles that eliminate safety wire:
The turnbuckle barrel features longitudinal slots machined into its outer surface, and the threaded terminal shanks have mating longitudinal keyway slots.
Installation: Curved stainless steel locking clips ( NAS1756 / MS21256 ) are inserted through holes in the center of the barrel. The straight locking prongs press firmly into the longitudinal slots of the barrel and terminal shanks, preventing relative rotation.
Inspection Rule: Technicians must visually verify positive clip seating in the keyways. Locking clips must NEVER be reused once removed; bent or fatigue-cycled clips lose spring retention and must be discarded.
3. Pulleys, Cable Guards & Alignment Tolerances
Control pulleys redirect cable runs around structural obstacles and bulkheads. PULLEY GROOVE WEAR & ALIGNMENT:
- [ Normal Seating ] [ Cable Misalignment (Max 2°) ] [ Cable Guard Pin ]
- ┌─────────┐ ┌─────────┐ ┌─────────┐
- │ Cable │ │ ◄── Cable Rides Flange │ Cable │ ◄─ Max 1/16" Gap
- ┌┴─────────┴┐ ┌┴─────────┴┐ ──┼─────────┼── Guard Pin
- │ Groove │ │ Groove │ │ Groove │
- └───────────┘ └───────────┘ └─────────┘
- Cable seated in bottom Misalignment > 2° Causes Chafing Prevents Cable Jumping
- Pulley Inspection & Defect Criteria
Material Types: Pulleys are manufactured from phenolic laminate (Micarta), molded plastic/composite resin, or anodized aluminum alloy with sealed ball bearings or bronze bushings.
Groove Wear Assessment:
The cable must seat fully in the bottom of the groove , contacting approximately 1 / 3 1/3 1/3 of the groove circumference.
If the cable rides up the sidewalls or if the pulley exhibits flat spots (caused by seized bearings), the pulley and cable must be replaced.
Cable Guards: Every pulley must be equipped with close-tolerance cable guards (pins or cotter pins). The clearance between the guard pin and the pulley flange must not exceed 1 / 16 " 1/16" 1/16" ( 0.062 " 0.062" 0.062" ) to prevent the cable from jumping out of the groove if it slackens during negative-G maneuvers or turbulence.
Maximum Pulley Misalignment: The maximum allowable angular misalignment between the control cable and the centerline plane of the pulley is 2 ∘ 2^\circ 2 ∘ . Misalignment exceeding 2 ∘ 2^\circ 2 ∘ causes severe cable chafing against the pulley flange and rapid groove destruction.
4. Fairleads, Guides & Pressurized Bulkhead Seals FAIRLEAD CABLE DEFLECTION LIMIT (Max 3°):
- Bulkhead Structure
- │ ┌───────────┐
- └──┤ Fairlead │ ◄── Phenolic / Teflon Guide Block
- ═══════╡ (Block) ╞═════════════════════════════════════ ◄── Control Cable
- ┌──┤ │ ╲
│ └───────────┘ ╲ Deflection Angle (θ) MUST NOT EXCEED 3°!
- │ ╲
- Fairlead Rules & Wear Limits (AC 43.13-1B)
Purpose: Fairleads (fabricated from phenolic laminate or Teflon) support straight runs of cable, dampen cable vibration, and prevent the steel cable from chafing against metal bulkheads, ribs, and fuselage frames.
Maximum Deflection Limit: Fairleads are not load-bearing pulleys . The maximum allowable angle of cable deflection produced by a fairlead is 3 ∘ 3^\circ 3 ∘ .
Wear Limits: Fairleads must be inspected for grooving and wear. If the cable has worn deeper than 1 / 3 1/3 1/3 of the fairlead block thickness , or if the fairlead is loose in its structural mounting, it must be replaced. A cable must NEVER contact the surrounding metal structure.
Bulkhead Pressure Seals: Where cables penetrate pressurized cabin bulkheads, flexible elastomeric boots or low-friction mechanical seals are installed. These seals must be inspected for tears, stiffness, and excessive air leakage while ensuring zero control friction drag.
5. Cable Swaging & Terminal Inspection Standards
Aircraft control cable ends are terminated using permanently swaged fittings to provide maximum mechanical joint strength. SWAGED TERMINAL INSPECTION:
[ MS Swaged Ball / Stud ] [ Nicopress Oval Sleeve ]
- Terminal Shank Cable Copper Sleeve Thimble Eye
- ┌──────────────┐ ┌─────────────┐ ┌───┐
- ═══╡ Diameter (D) ╞═══════════════════ ═══╡ Squeeze ╞═══════╡ O │
- └──────────────┘ └─────────────┘ └───┘
- Measure OD with Micrometer Verify with Go / No-Go Gauge
- Comparison of Swaging Methods & Inspection Criteria
Terminal Type Hardware Standard Tooling Required Inspection & Quality Verification Method
MS Swaged Terminals (Ball, Fork, Eye, Stud) MS20664 (Ball), MS20667 (Fork), MS20668 (Eye), MS21259 (Stud) Hydraulic or rotary rotary cold-swaging machine. Measure the outside diameter ( O D OD O D ) of the swaged shank using a precision micrometer against standard dimensional tables. Inspect for longitudinal cracks, straightness ( < 0.005 " / in <0.005"/\text{in} < 0.005"/ in runout), and paint slippage marks.
Nicopress Oval Sleeves Copper or aluminum oval sleeves (MS51844) with galvanized or CRES steel thimbles. Calibrated Nicopress toggle-action hand or hydraulic swager. Squeeze sequence (center to outer). Measure compressed sleeve thickness using a Go / No-Go slot gauge . The sleeve must enter the "Go" slot and NOT enter the "No-Go" slot.
Swaging Defects & Rejection Rules
Over-Swaging: Causes excessive work-hardening and micro-cracking of the terminal metal, reducing joint tensile strength.
Under-Swaging: Fails to achieve full metal-to-metal cold-flow into cable valleys, resulting in catastrophic cable slippage under tension.
Cable Slippage Check: Technicians must apply a strip of red or white lacquer/paint at the junction of the cable and terminal sleeve prior to proof loading. Any cracked or displaced paint indicates terminal slippage, requiring immediate rejection and replacement.