Study guide
3.3 Aircraft Lead-Acid & Nickel-Cadmium Storage Batteries
FAA Aviation Mechanic — General AMG
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & AMG Exam Overview
1.1 About the FAA Aviation Mechanic General Knowledge Test 1.2 How to Study for the AMG Exam
2 Chapter 2: Maintenance Forms, Records, Publications & Regulations
2.1 14 CFR Parts 43, 65, and 91 Regulatory Framework 2.2 Aviation Mechanic Privileges, Limitations & Recent Experience 2.3 Maintenance Recordkeeping & Return-to-Service Entries (14 CFR 43.9 & 43.11) 2.4 FAA Form 337 Major Repairs and Major Alterations 2.5 Airworthiness Directives (ADs) & Mandatory Compliance 2.6 Type Certificate Data Sheets (TCDS), STCs, ACs & Maintenance Manuals 2.7 FAA Forms, MMEL/MEL, Inoperative Equipment & Parts Effectivity
3 Chapter 3: Basic Electricity
3.1 DC Electrical Circuits, Ohm's Law & Power 3.2 AC Electrical Fundamentals, Reactance & Impedance 3.3 Aircraft Lead-Acid & Nickel-Cadmium Storage Batteries 3.4 DC Generators, Alternators & Electric Motors 3.5 Aircraft Wiring, Bonding & Circuit Protection Devices 3.6 Resistor Color Codes, Semiconductors, Digital Logic & Electrostatic Discharge
4 Chapter 4: Materials & Processes
4.1 Aircraft Ferrous and Nonferrous Metals & Heat Treatment 4.2 Metal Hardness Testing (Rockwell, Brinell, Vickers) 4.3 Nondestructive Testing (NDT/NDI) Inspection Methods 4.4 Aircraft Hardware, Fasteners & Safetying Methods 4.5 Composite Materials, Plastics & Control Cables 4.6 Soldering, Welding & Weld Quality Inspection
5 Chapter 5: Cleaning & Corrosion Control
5.1 Corrosion Types, Chemistry & Identification 5.2 Corrosion Removal, Chemical Conversion Coatings & Surface Treatments 5.3 Aircraft Cleaning Agents, Precautions & Preventative Maintenance 5.4 Aircraft Finishing Systems, Registration Markings & Placards
6 Chapter 6: Weight & Balance
6.1 Weight and Balance Terminology, Datum, Arm & Moment Principles 6.2 Aircraft Weighing Procedures, Scale Reactions & Tare Weight 6.3 Center of Gravity Computations, Extreme Loading & Ballast
7 Chapter 7: Ground Operation, Servicing & Safety
7.1 Engine Starting Procedures, Danger Areas & Ground Taxi Safety 7.2 Aircraft Servicing (Oxygen, Hydraulic, Pneumatic & De-Icing Fluids) 7.3 Aircraft Fueling Safety, Static Grounding & Hangar Fire Protection 7.4 Airport Movement Areas, Hazardous Materials, Tool Control & FOD Prevention
8 Chapter 8: Aircraft Drawings
8.1 Aircraft Drawing Types, Title Blocks & Orthographic Projections 8.2 Line Conventions, Dimensions, Tolerances & Material Symbols 8.3 Electrical Wiring Diagrams, Logic Flowcharts & Fluid Schematics
9 Chapter 9: Fluid Lines & Fittings
9.1 Rigid Metal Tubing Fabrication, Bending & 37° AN Flaring 9.2 Flexible Hose Construction, Pressure Ratings & Lay Lines 9.3 AN/MS/Quick-Disconnect Fittings, Identification & Installation
10 Chapter 10: Mathematics for Aviation Maintenance
10.1 Fractions, Decimals, Percentages & Ratio/Proportion 10.2 Geometric Computations (Area, Volume & Cylinder Displacement) 10.3 Algebraic Equations, Powers, Roots & Maintenance Conversions
11 Chapter 11: Physics for Aviation Maintenance
11.1 Matter, Mass, Weight, Density & Specific Gravity 11.2 Work, Energy, Power & Simple Machines (Mechanical Advantage) 11.3 Fluid Mechanics, Pascal's Law & Bernoulli's Principle 11.4 Thermodynamics, Heat Transfer, Gas Laws, Sound & Aerodynamics 11.5 Standard Atmosphere, Density & Pressure Altitude, Flight Controls & Aerodynamic Devices
12 Chapter 12: Inspection Concepts, Techniques & Precision Measurement
12.1 Aircraft Inspection Programs & Inspection Concepts 12.2 Precision Measuring Tools & Tool Calibration
13 Chapter 13: Human Factors in Aviation Maintenance
13.1 Human Error, the Dirty Dozen & Maintenance Safety Culture 13.2 Human Performance, Limitations, Fatigue & the Work Environment 13.3 Communication, Shift Turnover, Event Investigation & Professionalism
3.3 Aircraft Lead-Acid & Nickel-Cadmium Storage Batteries
Key Takeaways Explain This Topic AI
Lead-acid aircraft batteries use lead dioxide positive plates, sponge lead negative plates, and dilute sulfuric acid ( H 2 S O 4 H_2SO_4 H 2 S O 4 ) electrolyte; state of charge is directly measured using a temperature-corrected hydrometer (1.275–1.300 fully charged, 1.150 discharged).
Lead-acid hydrometer readings must be corrected for temperature: add 0.004 (4 gravity points) for every 10°F above 80°F, and subtract 0.004 for every 10°F below 80°F.
Nickel-Cadmium (Ni-Cad) batteries use nickel oxyhydroxide positive plates, cadmium negative plates, and potassium hydroxide ( K O H KOH K O H ) electrolyte; KOH acts strictly as an ion conductor and does NOT change specific gravity between charge and discharge.
Ni-Cad state of charge cannot be tested with a hydrometer; it must be verified exclusively through a constant-current capacity discharge test (down to 1.0V/cell cutoff, requiring ≥ 80 % \ge 80\% ≥ 80% rated capacity for airworthiness).
Ni-Cad batteries are subject to destructive thermal runaway on constant-voltage charging due to their negative temperature coefficient of resistance; lead-acid and Ni-Cad maintenance shops, tools, and chemicals must remain strictly segregated.
Last updated: August 2026
3.3 Aircraft Lead-Acid & Nickel-Cadmium Storage Batteries
Aircraft storage batteries serve three critical functions: providing emergency electrical power during in-flight generator failures, supplying high-rate starting current for auxiliary power units (APUs) and main engines, and dampening DC bus voltage transients. Aviation maintenance technicians service two distinct secondary chemical battery systems: Lead-Acid and Nickel-Cadmium (Ni-Cad) .
1. Lead-Acid Battery Chemistry & Construction
An aircraft lead-acid battery comprises multiple galvanic cells connected in series within an impact-resistant polypropylene or hard rubber case. Each cell consists of interleaved positive and negative plate groups separated by porous insulating sheets.
Cell Chemistry & Materials
Positive Plate Group: Active material is Lead Dioxide ( PbO 2 \text{PbO}_2 PbO 2 ) , distinctively dark chocolate brown.
Negative Plate Group: Active material is pure porous Spongy Metallic Lead ( Pb \text{Pb} Pb ) , slate gray.
Electrolyte Solution: A dilute aqueous solution of Sulfuric Acid ( H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 ) and distilled water ( H 2 O \text{H}_2\text{O} H 2 O ), approximately 35 % 35\% 35% acid and 65 % 65\% 65% water by weight in a fully charged cell. Lead-Acid Chemical Reaction:
DISCHARGE:
- PbO2 (Pos) + Pb (Neg) + 2H2SO4 (Electrolyte)
- --> 2PbSO4 (Both Plates) + 2H2O (Electrolyte) + Electrical Energy
CHARGE (Reverse):
- 2PbSO4 (Both Plates) + 2H2O (Electrolyte) + Charging Energy
- --> PbO2 (Pos) + Pb (Neg) + 2H2SO4 (Electrolyte)
- Electrochemical Dynamics
During Discharge: Both positive and negative plates react with sulfuric acid to form Lead Sulfate ( PbSO 4 \text{PbSO}_4 PbSO 4 ) . Sulfuric acid is consumed and water is created, diluting the electrolyte and lowering its specific gravity.
During Charge: Applied charging current strips sulfate ions from the plates, reforming PbO 2 \text{PbO}_2 PbO 2 on positive plates, spongy Pb \text{Pb} Pb on negative plates, and returning sulfuric acid to the electrolyte, increasing its specific gravity.
Nominal Cell Voltage: An open-circuit lead-acid cell produces approximately 2.1 V 2.1\text{V} 2.1 V to 2.2 V 2.2\text{V} 2.2 V . A 12-cell battery provides a nominal 24 V 24\text{V} 24 V rating (charged at 28 V 28\text{V} 28 V bus voltage); a 6-cell battery provides a nominal 12 V 12\text{V} 12 V rating (charged at 14 V 14\text{V} 14 V ).
Gassing: As full charge is reached, charging current electrolyzes water, liberating explosive Hydrogen gas ( H 2 \text{H}_2 H 2 ) at negative plates and Oxygen gas ( O 2 \text{O}_2 O 2 ) at positive plates. Battery sumps and overboard vent tubes exhaust these gases safely overboard.
Valve-Regulated Lead-Acid (VRLA) / Absorbed Glass Mat (AGM)
Modern aircraft frequently utilize Sealed VRLA / AGM batteries. The sulfuric acid electrolyte is immobilized within micro-fiberglass mat separators. AGM batteries are spill-proof in any flight attitude, require no fluid replenishment, and feature internal recombinant catalysts that recombine 99 % 99\% 99% of generated hydrogen and oxygen back into water.
Loading diagram... Lead-Acid Hydrometer Temperature Compensation Logic
2. Lead-Acid Specific Gravity Testing & Temperature Correction
Specific gravity (SG) is the ratio of the weight of a given volume of electrolyte to the weight of an equal volume of pure distilled water ( 1.000 1.000 1.000 at 4 ∘ C 4^\circ\text{C} 4 ∘ C ). Because pure sulfuric acid has a specific gravity of 1.835 1.835 1.835 , electrolyte specific gravity serves as a direct, reliable indicator of state of charge in lead-acid batteries.
Temperature Compensation Rule per AC 43.13-1B
Hydrometers are calibrated for an electrolyte reference temperature of 80 ∘ F 80^\circ\text{F} 8 0 ∘ F ( 26.7 ∘ C 26.7^\circ\text{C} 26. 7 ∘ C ) . Liquids expand when heated (becoming less dense) and contract when cooled (becoming denser):
High Temperature ( > 80 ∘ F >80^\circ\text{F} > 8 0 ∘ F ): Hydrometer float sinks deeper, giving a falsely low reading. ADD 0.004 0.004 0.004 ( 4 gravity points 4\text{ gravity points} 4 gravity points ) for every 10 ∘ F 10^\circ\text{F} 1 0 ∘ F ABOVE 80 ∘ F 80^\circ\text{F} 8 0 ∘ F .
Low Temperature ( < 80 ∘ F <80^\circ\text{F} < 8 0 ∘ F ): Hydrometer float floats higher, giving a falsely high reading. SUBTRACT 0.004 0.004 0.004 ( 4 gravity points 4\text{ gravity points} 4 gravity points ) for every 10 ∘ F 10^\circ\text{F} 1 0 ∘ F BELOW 80 ∘ F 80^\circ\text{F} 8 0 ∘ F . Corrected SG = Observed SG + ( Electrolyte Temp ( ∘ F ) − 80 10 × 0.004 ) \text{Corrected SG} = \text{Observed SG} + \left(\frac{\text{Electrolyte Temp }(^\circ\text{F}) - 80}{10} \times 0.004\right) Corrected SG = Observed SG + ( 10 Electrolyte Temp ( ∘ F ) − 80 × 0.004 )
State-of-Charge Interpretation Table
Specific Gravity (Corrected to 80°F) State of Charge Maintenance Disposition
1.275 to 1.300 100% Fully Charged Airworthy; normal operational range.
1.240 to 1.260 75% Charged Satisfactory; normal service state.
1.200 to 1.220 50% Charged Low reserve; bench recharge recommended.
1.160 to 1.180 25% Charged Unsatisfactory for flight dispatch.
1.150 and below Discharged / Dead Full shop bench recharge and capacity test required.
Cell Variation Airworthiness Limit: If the temperature-corrected specific gravity between any two cells in the same lead-acid battery differs by more than 0.050 0.050 0.050 ( 50 gravity points 50\text{ gravity points} 50 gravity points ) , an internal short or sulfated cell exists, and the battery must be removed from service and replaced.
3. Nickel-Cadmium (Ni-Cad) Battery Chemistry & Operation
Nickel-Cadmium (Ni-Cad) batteries deliver superior high-rate discharge current for turbine engine starting, maintain stable terminal voltage under heavy loads, and operate reliably across extreme temperature ranges ( − 40 ∘ C -40^\circ\text{C} − 4 0 ∘ C to + 60 ∘ C +60^\circ\text{C} + 6 0 ∘ C ).
Construction and Electrochemistry
Positive Plate Group: Sintered nickel porous plaque impregnated with Nickel Oxyhydroxide ( NiOOH \text{NiOOH} NiOOH ) in charged state / Nickel Hydroxide ( Ni(OH) 2 \text{Ni(OH)}_2 Ni(OH) 2 ) in discharged state.
Negative Plate Group: Sintered nickel porous plaque impregnated with metallic Cadmium ( Cd \text{Cd} Cd ) in charged state / Cadmium Hydroxide ( Cd(OH) 2 \text{Cd(OH)}_2 Cd(OH) 2 ) in discharged state.
Separators: Multi-layer barrier consisting of woven continuous nylon fabric for mechanical separation and cellophane / microporous polypropylene membrane to block cadmium dendritic migration.
Electrolyte: A 30 % 30\% 30% by weight solution of Potassium Hydroxide ( KOH \text{KOH} KOH ) in distilled water, with a specific gravity of approximately 1.240 1.240 1.240 to 1.300 1.300 1.300 . Ni-Cad Chemical Reaction:
DISCHARGE:
- 2NiOOH (Pos) + Cd (Neg) + 2H2O (Water)
- --> 2Ni(OH)2 (Pos) + Cd(OH)2 (Neg) + Electrical Energy
CHARGE (Reverse):
- 2Ni(OH)2 (Pos) + Cd(OH)2 (Neg) + Charging Energy
- --> 2NiOOH (Pos) + Cd (Neg) + 2H2O (Water)
- CRITICAL DIAGNOSTIC PRINCIPLE: Hydrometer vs. State of Charge
In a Ni-Cad cell, potassium hydroxide ( KOH \text{KOH} KOH ) does not chemically react with or enter into the active plate materials during charge or discharge; it functions strictly as an ionized electron transfer medium (hydroxyl OH − \text{OH}^- OH − ion conductor).
Consequently, the specific gravity of Ni-Cad electrolyte does NOT change significantly between full charge and complete discharge!
A hydrometer CANNOT be used to evaluate the state of charge of a Ni-Cad battery!
State of charge is determined exclusively by performing a controlled constant-current capacity discharge test on a calibrated battery test bench per manufacturer maintenance manuals (C-rate discharge down to an endpoint cutoff of 1.0 V 1.0\text{V} 1.0 V per cell; the battery must deliver ≥ 80 % \ge 80\% ≥ 80% of rated ampere-hour capacity to remain airworthy per 14 CFR Part 43 / AC 43.13-1B).
Water Replenishment Protocol
Water is consumed only through electrolysis during overcharge.
MANDATORY PROCEDURE: Distilled or demineralized water must ONLY be added at the end of a constant-current charge cycle , while the battery is still connected to the charger, fully charged, and actively gassing.
Adding water to a discharged or partially charged Ni-Cad battery will cause violent electrolyte spewing and overflow during subsequent recharging , because electrolyte is drawn deep into the sintered plate pores during discharge and expelled into the cell headspace during charge.
- 4. Ni-Cad Thermal Runaway Hazard & Mitigation
- The Mechanism of Thermal Runaway
Ni-Cad batteries exhibit a negative temperature coefficient of internal electrical resistance : as cell temperature rises, internal electrical resistance decreases.
When charged from an aircraft constant-voltage DC bus (e.g., 28 V 28\text{V} 28 V DC), an overheated cell (caused by heavy engine starting cycles or high ambient temperatures) experiences a reduction in internal resistance ( R i n t R_{int} R in t ).
By Ohm's Law ( I = E b u s − E b a t t R i n t I = \frac{E_{bus} - E_{batt}}{R_{int}} I = R in t E b u s − E ba tt ), lower resistance causes the battery to draw significantly higher charging current from the bus.
Increased current produces higher I 2 R I^2R I 2 R internal heating, which further raises cell temperature.
Higher temperature further reduces resistance, establishing an escalating positive feedback loop: Thermal Runaway .
Thermal runaway results in electrolyte boiling, violent release of toxic caustic KOH vapor, separator meltdown, catastrophic fire, and cell explosion. Thermal Runaway Escalation Loop:
- +--> High Cell Temperature ---> Decreased Internal Resistance (R) --+
- | |
- +--- High I²R Internal Heat <--- Increased Bus Charging Current (I) -+
- Protective Systems & Constant-Current Charging
Temperature Monitoring: Internal thermistors and thermal switches mounted between center cells monitor temperature and illuminate cockpit annunciators ("BATTERY OVERHEAT" or "BATT TEMP > 140°F / 60°C").
Automatic Disconnect: Dedicated battery chargers automatically disconnect the battery from the charging bus when cell temperature exceeds safe limits ( > 140 ∘ F / 60 ∘ C >140^\circ\text{F} / 60^\circ\text{C} > 14 0 ∘ F /6 0 ∘ C ) or if charging current fails to taper.
Constant-Current vs. Constant-Voltage Charging: Ni-Cad shop servicing is conducted exclusively with constant-current chargers , which hold charging current steady regardless of temperature-induced resistance changes, completely preventing thermal runaway.
Ni-Cad Deep-Discharge Cell Reconditioning
Repeated shallow cycling causes cadmium crystalline agglomeration, resulting in apparent capacity loss ("memory effect") and cell voltage imbalance. Technicians perform periodic deep discharge reconditioning:
Discharge battery at rated current down to 1.0 V 1.0\text{V} 1.0 V per cell.
Connect individual shorting clips (resistors or jumper wires) directly across each cell terminal for 12 12 12 to 24 hours 24\text{ hours} 24 hours , pulling cell voltages to exactly 0.0 V 0.0\text{V} 0.0 V .
Equalize all cells to an identical discharged state, followed by a complete constant-current recharge.
5. Battery Shop Safety & Maintenance Segregation
Because lead-acid and Ni-Cad batteries utilize chemically incompatible active electrolytes, strict FAA facility segregation standards apply per AC 43.13-1B Chapter 11.
Chemical Contamination Hazards
Sulfuric Acid (Lead-Acid): Highly acidic ( pH < 1 \text{pH} < 1 pH < 1 ). Acid fumes or residue in contact with a Ni-Cad battery will permanently neutralize the alkaline potassium hydroxide electrolyte and destroy porous nylon/cellophane separators.
Potassium Hydroxide (Ni-Cad): Highly alkaline / caustic base ( pH > 13 \text{pH} > 13 pH > 13 ). Alkaline fumes in contact with lead-acid cells will neutralize sulfuric acid, forming potassium sulfate and destroying lead plates.
FAA Shop Maintenance Isolation Rules
Physical Room Separation: Lead-acid and Ni-Cad servicing must take place in completely separate, dedicated rooms equipped with dedicated, non-interconnected exhaust ventilation systems. If isolated rooms are unavailable, work areas must be physically separated by sealed partitions.
Tool and Equipment Isolation: Dedicated tools, hydrometers, syringes, torque wrenches, distilled water containers, and PPE must be color-coded and strictly segregated. Never use a lead-acid hydrometer on a Ni-Cad battery, or vice versa.
Neutralizing Agents and Cleaning
Battery Chemistry Electrolyte Chemical Spill Neutralizing Agent Cleaning / Terminal Treatment
Lead-Acid Sulfuric Acid ( H 2 SO 4 \text{H}_2\text{SO}_4 H 2 SO 4 ) Sodium Bicarbonate (Baking Soda, NaHCO 3 \text{NaHCO}_3 NaHCO 3 ) or dilute Ammonia solution Wash with water; coat terminals with pure petroleum jelly / anti-corrosion grease.
Nickel-Cadmium Potassium Hydroxide ( KOH \text{KOH} KOH ) Boric Acid ( H 3 BO 3 \text{H}_3\text{BO}_3 H 3 BO 3 , 3% solution) or dilute Vinegar (Acetic Acid) Clean white potassium carbonate ( K 2 CO 3 \text{K}_2\text{CO}_3 K 2 CO 3 ) crust with warm demineralized water and nylon brush; torque terminal hardware to exact manual limits.
- 6. Worked Numerical Examples
- Example 1: Hydrometer Temperature Correction (High Ambient Temperature)
Problem: During an annual inspection on a flightline in summer, a technician measures the electrolyte specific gravity of a lead-acid battery cell as 1.268 1.268 1.268 with an electrolyte temperature of 105 ∘ F 105^\circ\text{F} 10 5 ∘ F ( 40.6 ∘ C 40.6^\circ\text{C} 40. 6 ∘ C ).
Calculate the temperature-corrected specific gravity and evaluate the battery state of charge.
Solution:
Calculate the temperature difference above the 80 ∘ F 80^\circ\text{F} 8 0 ∘ F reference: Δ T = 105 ∘ F − 80 ∘ F = 25 ∘ F \Delta T = 105^\circ\text{F} - 80^\circ\text{F} = 25^\circ\text{F} Δ T = 10 5 ∘ F − 8 0 ∘ F = 2 5 ∘ F
Calculate the correction factor ( 0.004 0.004 0.004 per 10 ∘ F 10^\circ\text{F} 1 0 ∘ F ): Correction = 25 ∘ F 10 ∘ F × 0.004 = 2.5 × 0.004 = + 0.010 \text{Correction} = \frac{25^\circ\text{F}}{10^\circ\text{F}} \times 0.004 = 2.5 \times 0.004 = +0.010 Correction = 1 0 ∘ F 2 5 ∘ F × 0.004 = 2.5 × 0.004 = + 0.010
Add correction to observed reading: Corrected SG = 1.268 + 0.010 = 1.278 \text{Corrected SG} = 1.268 + 0.010 = 1.278 Corrected SG = 1.268 + 0.010 = 1.278
Evaluation: Corrected specific gravity of 1.278 1.278 1.278 falls in the 1.275 – 1.300 1.275\text{--}1.300 1.275 – 1.300 range, confirming the cell is 100 % 100\% 100% fully charged .
Example 2: Hydrometer Temperature Correction (Cold Ambient Temperature)
Problem: In an unheated hangar during winter, a lead-acid battery electrolyte hydrometer reads 1.285 1.285 1.285 at an electrolyte temperature of 30 ∘ F 30^\circ\text{F} 3 0 ∘ F ( − 1.1 ∘ C -1.1^\circ\text{C} − 1. 1 ∘ C ).
Calculate the temperature-corrected specific gravity.
Solution:
Calculate temperature difference below 80 ∘ F 80^\circ\text{F} 8 0 ∘ F : Δ T = 80 ∘ F − 30 ∘ F = 50 ∘ F \Delta T = 80^\circ\text{F} - 30^\circ\text{F} = 50^\circ\text{F} Δ T = 8 0 ∘ F − 3 0 ∘ F = 5 0 ∘ F
Calculate correction factor: Correction = 50 ∘ F 10 ∘ F × 0.004 = 5.0 × 0.004 = 0.020 \text{Correction} = \frac{50^\circ\text{F}}{10^\circ\text{F}} \times 0.004 = 5.0 \times 0.004 = 0.020 Correction = 1 0 ∘ F 5 0 ∘ F × 0.004 = 5.0 × 0.004 = 0.020
Subtract correction from observed reading: Corrected SG = 1.285 − 0.020 = 1.265 \text{Corrected SG} = 1.285 - 0.020 = 1.265 Corrected SG = 1.285 − 0.020 = 1.265
Evaluation: The cell is approximately 80 % 80\% 80% charged (not fully charged as the uncorrected 1.285 1.285 1.285 reading suggested).
Example 3: Ni-Cad Battery Capacity Test Calculation
Problem: A 24 V 24\text{V} 24 V , 40 Ampere-hour (Ah) 40\text{ Ampere-hour (Ah)} 40 Ampere-hour (Ah) rated aircraft Ni-Cad battery undergoes an annual shop capacity test at a constant 1 C 1\text{C} 1 C discharge rate ( 40.0 Amperes 40.0\text{ Amperes} 40.0 Amperes ). The battery sustains current until the first cell drops to the 1.0 V 1.0\text{V} 1.0 V cutoff threshold at 51 minutes 51\text{ minutes} 51 minutes ( 0.85 hours 0.85\text{ hours} 0.85 hours ).
Calculate the delivered capacity and determine if the battery meets the FAA 80 % 80\% 80% airworthiness minimum requirement.
Solution:
Calculate delivered ampere-hour capacity: Delivered Capacity = I × t = 40.0 A × ( 51 60 h ) = 40.0 A × 0.85 h = 34.0 Ah \text{Delivered Capacity} = I \times t = 40.0\text{ A} \times \left(\frac{51}{60}\text{ h}\right) = 40.0\text{ A} \times 0.85\text{ h} = 34.0\text{ Ah} Delivered Capacity = I × t = 40.0 A × ( 60 51 h ) = 40.0 A × 0.85 h = 34.0 Ah
Calculate percentage of rated capacity delivered: % Capacity = ( Delivered Ah Rated Ah ) × 100 = ( 34.0 Ah 40.0 Ah ) × 100 = 85.0 % \% \text{ Capacity} = \left(\frac{\text{Delivered Ah}}{\text{Rated Ah}}\right) \times 100 = \left(\frac{34.0\text{ Ah}}{40.0\text{ Ah}}\right) \times 100 = 85.0\% % Capacity = ( Rated Ah Delivered Ah ) × 100 = ( 40.0 Ah 34.0 Ah ) × 100 = 85.0%
Evaluation: Because 85.0 % ≥ 80.0 % 85.0\% \ge 80.0\% 85.0% ≥ 80.0% , the battery satisfies the FAA airworthiness capacity threshold .