Study guide
3.5 Aircraft Wiring, Bonding & Circuit Protection Devices
FAA Aviation Mechanic — General AMG
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & AMG Exam Overview
1.1 About the FAA Aviation Mechanic General Knowledge Test 1.2 How to Study for the AMG Exam
2 Chapter 2: Maintenance Forms, Records, Publications & Regulations
2.1 14 CFR Parts 43, 65, and 91 Regulatory Framework 2.2 Aviation Mechanic Privileges, Limitations & Recent Experience 2.3 Maintenance Recordkeeping & Return-to-Service Entries (14 CFR 43.9 & 43.11) 2.4 FAA Form 337 Major Repairs and Major Alterations 2.5 Airworthiness Directives (ADs) & Mandatory Compliance 2.6 Type Certificate Data Sheets (TCDS), STCs, ACs & Maintenance Manuals 2.7 FAA Forms, MMEL/MEL, Inoperative Equipment & Parts Effectivity
3 Chapter 3: Basic Electricity
3.1 DC Electrical Circuits, Ohm's Law & Power 3.2 AC Electrical Fundamentals, Reactance & Impedance 3.3 Aircraft Lead-Acid & Nickel-Cadmium Storage Batteries 3.4 DC Generators, Alternators & Electric Motors 3.5 Aircraft Wiring, Bonding & Circuit Protection Devices 3.6 Resistor Color Codes, Semiconductors, Digital Logic & Electrostatic Discharge
4 Chapter 4: Materials & Processes
4.1 Aircraft Ferrous and Nonferrous Metals & Heat Treatment 4.2 Metal Hardness Testing (Rockwell, Brinell, Vickers) 4.3 Nondestructive Testing (NDT/NDI) Inspection Methods 4.4 Aircraft Hardware, Fasteners & Safetying Methods 4.5 Composite Materials, Plastics & Control Cables 4.6 Soldering, Welding & Weld Quality Inspection
5 Chapter 5: Cleaning & Corrosion Control
5.1 Corrosion Types, Chemistry & Identification 5.2 Corrosion Removal, Chemical Conversion Coatings & Surface Treatments 5.3 Aircraft Cleaning Agents, Precautions & Preventative Maintenance 5.4 Aircraft Finishing Systems, Registration Markings & Placards
6 Chapter 6: Weight & Balance
6.1 Weight and Balance Terminology, Datum, Arm & Moment Principles 6.2 Aircraft Weighing Procedures, Scale Reactions & Tare Weight 6.3 Center of Gravity Computations, Extreme Loading & Ballast
7 Chapter 7: Ground Operation, Servicing & Safety
7.1 Engine Starting Procedures, Danger Areas & Ground Taxi Safety 7.2 Aircraft Servicing (Oxygen, Hydraulic, Pneumatic & De-Icing Fluids) 7.3 Aircraft Fueling Safety, Static Grounding & Hangar Fire Protection 7.4 Airport Movement Areas, Hazardous Materials, Tool Control & FOD Prevention
8 Chapter 8: Aircraft Drawings
8.1 Aircraft Drawing Types, Title Blocks & Orthographic Projections 8.2 Line Conventions, Dimensions, Tolerances & Material Symbols 8.3 Electrical Wiring Diagrams, Logic Flowcharts & Fluid Schematics
9 Chapter 9: Fluid Lines & Fittings
9.1 Rigid Metal Tubing Fabrication, Bending & 37° AN Flaring 9.2 Flexible Hose Construction, Pressure Ratings & Lay Lines 9.3 AN/MS/Quick-Disconnect Fittings, Identification & Installation
10 Chapter 10: Mathematics for Aviation Maintenance
10.1 Fractions, Decimals, Percentages & Ratio/Proportion 10.2 Geometric Computations (Area, Volume & Cylinder Displacement) 10.3 Algebraic Equations, Powers, Roots & Maintenance Conversions
11 Chapter 11: Physics for Aviation Maintenance
11.1 Matter, Mass, Weight, Density & Specific Gravity 11.2 Work, Energy, Power & Simple Machines (Mechanical Advantage) 11.3 Fluid Mechanics, Pascal's Law & Bernoulli's Principle 11.4 Thermodynamics, Heat Transfer, Gas Laws, Sound & Aerodynamics 11.5 Standard Atmosphere, Density & Pressure Altitude, Flight Controls & Aerodynamic Devices
12 Chapter 12: Inspection Concepts, Techniques & Precision Measurement
12.1 Aircraft Inspection Programs & Inspection Concepts 12.2 Precision Measuring Tools & Tool Calibration
13 Chapter 13: Human Factors in Aviation Maintenance
13.1 Human Error, the Dirty Dozen & Maintenance Safety Culture 13.2 Human Performance, Limitations, Fatigue & the Work Environment 13.3 Communication, Shift Turnover, Event Investigation & Professionalism
3.5 Aircraft Wiring, Bonding & Circuit Protection Devices
Key Takeaways Explain This Topic AI
Aircraft airframe wiring standards require stranded copper (MIL-W-22759 / AS22759) with tin, silver, or nickel plating; aluminum is restricted to large gauge power feeders (AWG 8 and larger) with special anti-oxidant terminations.
American Wire Gauge (AWG) uses an inverse scale where smaller numbers denote larger conductors; minimum permitted gauge for general airframe runs is AWG 20 (AWG 22 permitted in supported bundles; AWG 24 in shielded electronics).
Wire bundles must be supported with MS21919 cushion clamps spaced 12–15 inches apart, have a maximum sag of 3/8 inch (0.375 in), incorporate drip loops before connectors, and maintain at least 6 inches clearance above fluid lines (2 inches minimum if clamped).
Circuit protection devices (fuses and circuit breakers) are sized exclusively to protect the aircraft WIRING from thermal overload, not the load device; 14 CFR Part 23/25 mandates 'Trip-Free' circuit breakers that cannot be held manually closed during a fault.
Electrical switches must be derated for non-resistive loads (derated to 20% for incandescent lamps, 33% for motors, and 50% for inductive solenoids); bonding jumpers must have a resistance of 0.003 ohms (3 milliohms) or less.
Last updated: August 2026
3.5 Aircraft Wiring, Bonding & Circuit Protection Devices
Aircraft electrical wiring constitutes a critical physical subsystem subject to intense environmental, mechanical, and electrical stresses. Aviation Maintenance Technicians must adhere strictly to FAA Advisory Circular AC 43.13-1B Chapter 11 (Aircraft Electrical Systems) and 14 CFR Parts 23, 25, 43, and 91 when sizing conductors, routing wire bundles, selecting circuit protection, and inspecting grounding systems.
- 1. Aircraft Conductor Metallurgy & AWG Sizing Standards
- Conductor Materials
Stranded Copper: The universal standard for aircraft airframe wiring (MIL-W-22759 / SAE AS22759). Conductors use fine multi-strand twisting (typically 19 to 133 individual strands) to resist vibration fatigue and flexing fracture. To prevent copper oxidation, individual strands are plated with:
Tin: Rated up to 150 ∘ C 150^\circ\text{C} 15 0 ∘ C ( 302 ∘ F 302^\circ\text{F} 30 2 ∘ F ).
Silver: Rated up to 200 ∘ C 200^\circ\text{C} 20 0 ∘ C ( 392 ∘ F 392^\circ\text{F} 39 2 ∘ F ).
Nickel: Rated up to 260 ∘ C 260^\circ\text{C} 26 0 ∘ C ( 500 ∘ F 500^\circ\text{F} 50 0 ∘ F ).
Aluminum Conductors: Used primarily for large power feeder runs ( AWG 8 and larger ) where substantial weight savings justify increased maintenance vigilance. Aluminum wire requires special installation precautions:
Prone to cold creep/flow under screw terminal pressure, leading to loose connections.
Forms an insulating aluminum oxide surface film upon exposure to air, requiring zinc-chromate or anti-oxidant joint compound (e.g., Alnox) during termination.
Highly susceptible to galvanic corrosion when coupled to dissimilar metals.
Wire Insulation Materials & Polyimide Cautions
ETFE (Tefzel) & PTFE (Teflon): Modern industry standard insulations offering excellent dielectric strength, abrasion resistance, chemical resistance to aviation fuels and Skydrol hydraulic fluid, and wide temperature ratings ( − 65 ∘ C -65^\circ\text{C} − 6 5 ∘ C to + 200 ∘ C +200^\circ\text{C} + 20 0 ∘ C ). Composite insulation constructions (such as PTFE/polyimide/PTFE) combine toughness with high dielectric performance.
Polyimide (Kapton) Cautions: First-generation aromatic polyimide tape insulation was widely installed on transport aircraft in the 1970s and 1980s. Under exposure to moisture, mechanical chafing, and alkaline fluids, old Kapton insulation is prone to hydrolysis and dry/wet arc tracking —a catastrophic failure mode where an electrical arc carbonizes the insulation into a conductive graphite path, causing explosive electrical flashovers along the entire wire bundle. FAA Aging Airplane rules and Airworthiness Directives prohibit installing unjacketed aromatic polyimide wire in severe wind and moisture environments (SWAMP areas) or high-vibration engine zones.
American Wire Gauge (AWG) Numbering System
The AWG system uses an inverse numerical scale : smaller numerical gauge numbers correspond to larger wire diameters, larger cross-sectional areas, and higher current-carrying capacities (e.g., AWG 4 is much larger than AWG 20). AWG Size vs Conductor Diameter Comparison:
- AWG 22 (Small): (•) d = 0.0253 in, Area = 640 CM
- AWG 16 (Medium): ( • ) d = 0.0508 in, Area = 2,580 CM
- AWG 8 (Large): ( • ) d = 0.1285 in, Area = 16,510 CM
Unit of Area (Circular Mil): Area of a circle having a diameter of 1 mil 1\text{ mil} 1 mil ( 0.001 inch 0.001\text{ inch} 0.001 inch ): Area in Circular Mils (CM) = [ Diameter in Mils ( d ) ] 2 \text{Area in Circular Mils (CM)} = [\text{Diameter in Mils } (d)]^2 Area in Circular Mils (CM) = [ Diameter in Mils ( d ) ] 2
Minimum Airframe Gauge Rules (AC 43.13-1B):
AWG 20 is the minimum wire size permitted for general airframe wiring runs to ensure sufficient mechanical strength.
AWG 22 is permitted only within securely tied and clamped bundles.
AWG 24 is restricted to shielded instrument harnesses and electronic equipment enclosures.
Allowable Voltage Drop Limits per AC 43.13-1B
Electrical System Nominal Voltage Continuous Operation Max Allowable Drop Intermittent Operation Max Allowable Drop
- 14V DC 0.5 Volts 1.0 Volt
- 28V DC 1.0 Volt 2.0 Volts
- 115V AC (Line-to-Neutral) 2.0 Volts 4.0 Volts
- 200V AC (Line-to-Line) 3.5 Volts 7.0 Volts
Conductor Sizing Equation (by Voltage Drop): Circular Mil Area (CM) = ρ × I × L V d r o p \text{Circular Mil Area (CM)} = \frac{\rho \times I \times L}{V_{drop}} Circular Mil Area (CM) = V d ro p ρ × I × L
ρ = 10.79 Ω ⋅ CM/ft \rho = 10.79\,\Omega\cdot\text{CM/ft} ρ = 10.79 Ω ⋅ CM/ft for copper at operating temperature ( 17.0 17.0 17.0 for aluminum).
I = Load Current in Amperes I = \text{Load Current in Amperes} I = Load Current in Amperes .
L = One-way Conductor Run Length in Feet L = \text{One-way Conductor Run Length in Feet} L = One-way Conductor Run Length in Feet .
V d r o p = Maximum Allowable Voltage Drop in Volts V_{drop} = \text{Maximum Allowable Voltage Drop in Volts} V d ro p = Maximum Allowable Voltage Drop in Volts .
Loading diagram... Aircraft Wire Bundle Routing and Fluid Separation Standards
- 2. Wire Bundling, Routing, Clamping & Inspection Practices
- Clamping and Support Standards (AC 43.13-1B Chapter 11)
Cushion Clamps: Wire bundles must be secured using MS21919 rubber- or fluorosilicone-cushioned metal clamps . Bare metal clamps or unlined plastic ties that can chafe insulation are prohibited. Clamps must hold the bundle firmly without pinching or deforming wire insulation.
Clamp Spacing: Clamps must be spaced not more than 12 to 15 inches 12\text{ to }15\text{ inches} 12 to 15 inches apart along the run.
Bundle Sag / Deflection Limit: Wire bundles must have sufficient slack for component servicing and terminal strain relief, but maximum bundle deflection (sag) between support clamps must not exceed 3 / 8 inch 3/8\text{ inch} 3/8 inch ( 0.375 in / 9.5 mm 0.375\text{ in} / 9.5\text{ mm} 0.375 in /9.5 mm ) under moderate hand pressure.
Minimum Bend Radius: The internal bend radius of a wire bundle must be at least 10 times 10\text{ times} 10 times the outside diameter ( 10 × OD 10\times\text{OD} 10 × OD ) of the bundle. For single wires or rigidly clamped breakouts, minimum bend radius is 3 × OD 3\times\text{OD} 3 × OD .
Service Loops: A service loop (extra wire length of 2 to 3 inches) must be provided at terminal junction strips and electrical connectors to allow for at least two to three future terminal re-terminations or pin replacements during maintenance. Wire Bundle Clamp & Sag Geometry:
- [MS21919 Clamp]================ Wire Bundle ================[MS21919 Clamp]
- \ /
- \ /
- v v
- 3/8" (0.375 in) Max Sag
- Drip Loops and Liquid Ingress Protection
A Drip Loop is a downward loop formed in a wire bundle immediately before entering an electrical connector, terminal junction box, or bulkhead penetration.
Moisture and condensed liquids running along the bundle collect at the lowest point of the loop and drip harmlessly away from the connector pins, preventing pin short circuits and galvanic terminal corrosion.
Separation from Flammable Fluid, Oxygen, and Hydraulic Lines
Vertical Hierarchy: Electrical wiring must ALWAYS be routed ABOVE flammable fluid, fuel, hydraulic, or oxygen plumbing to ensure leaking fluids cannot drip onto electrical conductors.
Clearance Distances:
Standard Minimum Separation: At least 6 inches 6\text{ inches} 6 inches ( 150 mm 150\text{ mm} 150 mm ) of physical clearance must be maintained between wire bundles and combustible fluid plumbing.
Constrained Airframe Exception: In cramped structural locations where 6 inches 6\text{ inches} 6 inches is physically impossible, a minimum clearance of 2 inches 2\text{ inches} 2 inches ( 50 mm 50\text{ mm} 50 mm ) is permitted, provided the wire bundle is rigidly clamped to primary structure so it cannot deflect, has no splices, and contains no electrical connectors in that zone.
Conduit Sizing & Fill Factor
When pulling wire bundles through rigid aluminum or flexible conduit, the inside cross-sectional area of the conduit must be at least 25 % 25\% 25% larger than the combined cross-sectional area of the wire bundle ( 75 % 75\% 75% maximum conduit fill factor ).
Drain holes ( 1 / 8 inch 1/8\text{ inch} 1/8 inch ) must be drilled at the lowest points of conduit runs to prevent water accumulation.
- 3. Circuit Protection Devices: Fuses & Trip-Free Circuit Breakers
- FUNDAMENTAL AIRWORTHINESS PRINCIPLE: Purpose of Circuit Protection
Circuit protection devices (fuses, thermal breakers, magnetic breakers) are selected and sized EXCLUSIVELY TO PROTECT THE AIRCRAFT WIRING FROM OVERHEATING, INSULATION MELTDOWN, AND FIRE —they are NOT designed to protect the connected end-load appliance!
The current rating of a fuse or circuit breaker must never exceed the maximum allowable current capacity of the smallest gauge wire in the protected circuit. Trip-Free Breaker Normal State: Trip-Free Overload (Plunger Held Down):
- [ Plunger ] [ Plunger HELD Down ]
- || ||
- --o---/\---o--- (Contacts Closed) ---o--- / ---o--- (Contacts OPEN)
- Trip-Free Circuit Breaker Mandate (14 CFR 23.1357 & 25.1357)
FAA Regulatory Mandate: All circuit breakers installed in essential aircraft electrical systems must be of the "Trip-Free" design.
Definition of Trip-Free: A trip-free circuit breaker will open the circuit and separate its internal electrical contacts during an overcurrent fault EVEN IF THE OPERATING PLUNGER / RESET BUTTON IS MANUALLY HELD IN THE "ON" / DEPRESSED POSITION by the flight crew or maintenance technician.
Non-trip-free circuit breakers (which can be held closed manually or reset automatically) are strictly prohibited in aircraft flight circuits because holding a tripped breaker closed during a continuous short circuit will instantly ignite wire insulation and structural airframe fires.
In-Flight Circuit Breaker Resetting Protocol
If a circuit breaker trips in flight, FAA standard airmanship and operating handbooks dictate: Allow a minimum cooling period of 2 to 3 minutes, then attempt ONE SINGLE RESET ONLY if the system is essential to flight safety .
If the breaker trips a second time, NEVER attempt another reset . Leave the breaker tripped, record the discrepancy in the aircraft maintenance log, and troubleshoot on the ground.
Aircraft Spare Fuse Inventory Rules (14 CFR 91.205(c)(6))
For aircraft operated at night (VFR Night) or under Instrument Flight Rules (IFR) equipped with replaceable cartridge fuses:
The aircraft must carry a spare fuse kit containing at least one spare fuse of each rating, or 50 % 50\% 50% of the total number of fuses of each rating installed, whichever is greater .
Example: If an aircraft panel contains eight 5 A 5\text{A} 5 A fuses and two 15 A 15\text{A} 15 A fuses, it must carry four 5 A 5\text{A} 5 A spares ( 50 % 50\% 50% of 8) and one 15 A 15\text{A} 15 A spare ( 50 % 50\% 50% of 2 = 1, minimum 1).
4. Switch Derating Factors and Load Calculations
Electrical switches are rated by manufacturers for continuous, non-inductive direct current resistive loads. When switches control non-resistive loads, high transient inrush currents or inductive kickback arcs require Switch Derating :
Standard Switch Derating Factors per AC 43.13-1B
Load Type Derating Factor Minimum Continuous Switch Rating Multiplier Engineering Rationale
Incandescent Lamp Loads 0.20 (20%) 5 × Continuous Lamp Current Cold tungsten lamp filaments have 1/10th the resistance of hot filaments, causing an initial inrush current spike 10 to 12 times normal running current.
DC Motor Loads 0.33 (33%) 3 × Continuous Running Current Starting inrush current (locked-rotor at 0 RPM) reaches 5 to 8 times running current before back-EMF develops.
Inductive Loads (Solenoids/Relays) 0.50 (50%) 2 × Continuous Coil Current Opening inductive circuits generates high-voltage inductive kickback arcs ( e L = − L d i d t e_L = -L \frac{di}{dt} e L = − L d t d i ) that pit switch contacts.
Resistive Heating Loads 0.80 (80%) 1.25 × Continuous Load Current Accounts for ambient thermal heating and internal contact resistance.
Switch Orientation Standard: Two-position toggle switches must be mounted in aircraft panels so that the toggle handle moves UP or FORWARD for the "ON" position , and DOWN or AFT for the "OFF" position .
- 5. Electrical Bonding, Grounding & Static Discharge
- Grounding vs. Bonding
Grounding: Connecting an electrical return conductor directly to the metallic airframe structure, establishing a single-wire ground return path to save conductor weight.
Bonding: Mechanically connecting all isolated structural metal components (control surfaces, engine cowlings, access doors) with low-resistance flexible metallic braided straps (bonding jumpers).
Bonding Jumper Requirements and Resistance Limits
Materials: Tinned copper braid or aluminum alloy jumpers. Copper jumpers must not be attached directly to aluminum structure without cadmium-plated washers to prevent galvanic corrosion.
Airworthiness Resistance Limit: The total electrical resistance across any structural bonding jumper, control surface hinge bond, or static ground joint must NOT EXCEED 0.003 Ohms 0.003\text{ Ohms} 0.003 Ohms ( 3 milliohms / 3 m Ω 3\text{ milliohms} / 3\text{ m}\Omega 3 milliohms /3 m Ω ) .
Purposes of Bonding:
Lightning Strike Protection: Conducts lightning strike currents (up to 200 , 000 Amperes 200,000\text{ Amperes} 200 , 000 Amperes ) safely through the outer skin to exit points without arcing across hinges or penetrating fuel vapor spaces.
Radio Shielding / EMI Suppression: Prevents high-frequency radio frequency interference (RFI).
Electrostatic Grounding: Dissipates friction-induced static charges.
Static Discharge Wicks
Precipitation Static (P-Static): When an aircraft flies through precipitation (rain, snow, ice crystals, or dust), frictional contact strips electrons from the airframe, accumulating high static voltage ( > 100 , 000 V >100,000\text{V} > 100 , 000 V ). This charge discharges into the atmosphere from sharp structural points in noisy, uncontrolled radio-frequency corona bursts, causing complete loss of VHF communication and ADF navigation.
Static Dischargers (Wicks): Resistive graphite-impregnated fibrous wicks installed on trailing edges of ailerons, elevators, rudder, and wingtips. They bleed accumulated static charge smoothly and continuously into the trailing airflow at low energy levels, eliminating radio interference.
- 6. Worked Numerical Examples
- Example 1: Conductor Sizing by Voltage Drop Formula
Problem: A 28.0 V 28.0\text{V} 28.0 V DC continuous landing light circuit draws 15.0 Amperes 15.0\text{ Amperes} 15.0 Amperes over a one-way wire run length of 40.0 feet 40.0\text{ feet} 40.0 feet . Per AC 43.13-1B, maximum allowable voltage drop under continuous load is 1.0 Volt 1.0\text{ Volt} 1.0 Volt . Annealed copper has ρ = 10.79 Ω ⋅ CM/ft \rho = 10.79\,\Omega\cdot\text{CM/ft} ρ = 10.79 Ω ⋅ CM/ft .
Calculate the minimum required Circular Mil (CM) area and select the appropriate standard AWG wire size.
Standard AWG Wire Table:
- AWG 16: 2 , 580 CM 2,580\text{ CM} 2 , 580 CM
- AWG 14: 4 , 110 CM 4,110\text{ CM} 4 , 110 CM
- AWG 12: 6 , 530 CM 6,530\text{ CM} 6 , 530 CM
- AWG 10: 10 , 380 CM 10,380\text{ CM} 10 , 380 CM
Solution:
Calculate required Circular Mil area: Area (CM) = ρ × I × L V d r o p = 10.79 × 15.0 A × 40.0 ft 1.0 V = 6 , 474.0 1.0 = 6 , 474 Circular Mils \text{Area (CM)} = \frac{\rho \times I \times L}{V_{drop}} = \frac{10.79 \times 15.0\text{ A} \times 40.0\text{ ft}}{1.0\text{ V}} = \frac{6,474.0}{1.0} = 6,474\text{ Circular Mils} Area (CM) = V d ro p ρ × I × L = 1.0 V 10.79 × 15.0 A × 40.0 ft = 1.0 6 , 474.0 = 6 , 474 Circular Mils
Compare with standard AWG table:
AWG 14 ( 4 , 110 CM 4,110\text{ CM} 4 , 110 CM ) is too small ( 4 , 110 < 6 , 474 4,110 < 6,474 4 , 110 < 6 , 474 ).
AWG 12 ( 6 , 530 CM 6,530\text{ CM} 6 , 530 CM ) meets and exceeds the minimum requirement ( 6 , 530 > 6 , 474 6,530 > 6,474 6 , 530 > 6 , 474 ).
Conclusion: Install AWG 12 MIL-W-22759 copper wire.
Example 2: Switch Derating for an Inductive Solenoid Load
Problem: A hydraulic shutoff solenoid valve on a 28.0 V 28.0\text{V} 28.0 V DC system draws a continuous coil current of 4.0 Amperes 4.0\text{ Amperes} 4.0 Amperes .
Calculate the minimum nominal switch current rating required per AC 43.13-1B inductive derating standards.
Solution:
Identify the derating factor for inductive loads: 0.50 0.50 0.50 (or multiplier 2.0 × 2.0\times 2.0 × ): Minimum Switch Rating = Continuous Load Current Derating Factor = 4.0 A 0.50 = 8.0 Amperes \text{Minimum Switch Rating} = \frac{\text{Continuous Load Current}}{\text{Derating Factor}} = \frac{4.0\text{ A}}{0.50} = 8.0\text{ Amperes} Minimum Switch Rating = Derating Factor Continuous Load Current = 0.50 4.0 A = 8.0 Amperes Or: Rating = 4.0 A × 2.0 = 8.0 Amperes \text{Or: } \text{Rating} = 4.0\text{ A} \times 2.0 = 8.0\text{ Amperes} Or: Rating = 4.0 A × 2.0 = 8.0 Amperes
Conclusion: Select a switch with a nominal rating of at least 8.0 Amperes 8.0\text{ Amperes} 8.0 Amperes (or the next higher standard rating, such as a 10 A 10\text{A} 10 A switch).
Example 3: Aircraft Spare Fuse Inventory (14 CFR 91.205)
Problem: An aircraft electrical fuse panel contains:
- Twelve 5 A 5\text{A} 5 A fuses
- Six 10 A 10\text{A} 10 A fuses
- Two 20 A 20\text{A} 20 A fuses
- One 30 A 30\text{A} 30 A fuse
Calculate the required spare fuse kit inventory for VFR Night / IFR operations.
Solution:
Calculate 50 % 50\% 50% count for each rating (minimum 1 of each rating):
5 A 5\text{A} 5 A fuses: 12 × 0.50 = 6 spare fuses 12 \times 0.50 = 6\text{ spare fuses} 12 × 0.50 = 6 spare fuses
10 A 10\text{A} 10 A fuses: 6 × 0.50 = 3 spare fuses 6 \times 0.50 = 3\text{ spare fuses} 6 × 0.50 = 3 spare fuses
20 A 20\text{A} 20 A fuses: 2 × 0.50 = 1 spare fuse 2 \times 0.50 = 1\text{ spare fuse} 2 × 0.50 = 1 spare fuse
30 A 30\text{A} 30 A fuses: 1 × 0.50 = 0.5 ⟹ 1 spare fuse 1 \times 0.50 = 0.5 \implies 1\text{ spare fuse} 1 × 0.50 = 0.5 ⟹ 1 spare fuse (minimum 1 required)
Total spare fuses required onboard: 6 + 3 + 1 + 1 = 11 spare fuses 6 + 3 + 1 + 1 = 11\text{ spare fuses} 6 + 3 + 1 + 1 = 11 spare fuses .