1 Chapter 1: Reciprocating Engine Theory & Construction

1.1 Four-Stroke Cycle & Otto Cycle Fundamentals 1.2 Valve Timing, Overlap & Duration 1.3 Compression Ratio, Manifold Pressure & Power Calculations 1.4 Crankshafts, Connecting Rods & Piston Assemblies

2 Chapter 2: Reciprocating Engine Dynamics & Valve Train

2.1 Detonation, Preignition & Combustion Anomalies 2.2 Dynamic Dampers, Counterweights & Vibration Control 2.3 Valve Clearance, Hydraulic Lifters & Radial Master Rods 2.4 Aviation Diesel & Compression-Ignition Engines

3 Chapter 3: Turbine Engine Theory & Compressors

3.1 Brayton Cycle, Thrust Principles & Spool Configurations 3.2 Axial vs. Centrifugal Compressors & Diffusers 3.3 Compressor Stalls, Angle of Attack & Bleed Systems

4 Chapter 4: Turbine Combustion, Turbines & Operational Hazards

4.1 Combustion Section Designs: Can, Annular & Can-Annular 4.2 Turbine Stages, Guide Vanes & Blade Creep 4.3 Turbine Operational Hazards: Hot Starts, Hung Starts & FOD 4.4 Turbofan, Turboprop & Auxiliary Power Units (APUs)

5 Chapter 5: Engine Ignition & Starting Systems

5.1 Magneto Operating Theory, E-Gap & Internal Timing 5.2 Magneto Check, P-Lead Grounding & Impulse Couplings 5.3 Aviation Spark Plugs: Heat Range, Fouling & Servicing 5.4 Turbine Ignition Systems & High-Energy Igniters 5.5 Solid-State & Electronic Ignition Systems

6 Chapter 6: Propeller Fundamentals & Governors

6.1 Propeller Aerodynamics, Blade Angle & Forces 6.2 Constant-Speed Governors & Pitch Change Mechanisms 6.3 Feathering, Unfeathering & Reversing Systems

7 Chapter 7: Propeller Maintenance & Turboprop Controls

7.1 Propeller Damage Limits, Minor Repairs & Servicing 7.2 Blade Tracking, Static & Dynamic Balancing 7.3 Turboprop Reduction Gearing & Beta Range Control

8 Chapter 8: Engine Fuel Metering Systems

8.1 Float-Type Carburetors & Internal Operating Systems 8.2 Carburetor Icing, Induction Heat & Density Changes 8.3 Pressure Injection Carburetors & Anti-Detonation Injection 8.4 Continuous-Flow Fuel Injection Systems (RSA & TCM) 8.5 Mixture Control, Leaning Procedures & Idle Adjustment

9 Chapter 9: Engine Lubrication Systems

9.1 Aviation Lubricant Properties, Functions & Viscosity Ratings 9.2 Wet-Sump vs. Dry-Sump Lubrication Architecture 9.3 Oil Pumps, Pressure Relief Valves & Scavenge Subsystems 9.4 Oil Filters, Coolers, Chip Detectors & Troubleshooting

10 Chapter 10: Induction, Supercharging & Engine Cooling

10.1 Reciprocating Induction Systems, Alternate Air & Air Filters 10.2 Superchargers, Turbochargers & Wastegate Controls 10.3 Air-Cooled Cylinder Cooling, Baffles & Cowl Flaps 10.4 Liquid Cooling Systems & Turbine Engine Cooling Flow 10.5 Augmenter Cooling Systems & Exhaust Noise Suppression

11 Chapter 11: Engine Electrical Systems

11.1 Starters, Alternators & DC Generators 11.2 Voltage Regulators, Current Limiters & Reverse-Current Relays 11.3 Engine Wiring Harnesses, Routing, Splicing & Clamping 11.4 Electrical Bonding, Grounding & Shielding Practices 11.5 AC Generation: Brushless Alternators, CSDs, IDGs & Paralleling

12 Chapter 12: Engine Instrument Systems

12.1 Pressure Instruments: Manifold, Oil & Fuel Pressure 12.2 Temperature Instruments: CHT, EGT & Thermocouple Principles 12.3 Tachometers, Spool Speed Sensors (N1/N2) & Synchroscopes 12.4 Turbine Performance Monitoring: EPR & Fuel Flow Indicating 12.5 Integrated Engine Indicating: EICAS, ECAM, Annunciators & Range Markings

13 Chapter 13: Aircraft Engine Fuel Systems

13.1 Fuel System Plumbing: Tanks, Selector Valves, Boost Pumps & Strainers 13.2 Vapor Lock, Fuel Contamination & Fuel Heaters 13.3 Turbine Engine Fuel Control Units: Hydromechanical & FADEC

14 Chapter 14: Engine Inspection, Records & Maintenance

14.1 100-Hour, Annual & Progressive Engine Inspections 14.2 Cylinder Compression Testing: Direct vs. Differential 14.3 Borescope Inspection Techniques & Defect Assessment 14.4 Airworthiness Directives (ADs), Service Bulletins & Logbook Entries 14.5 Special Inspections & Life-Limited Parts

15 Chapter 15: Engine Removal, Installation & Overhaul

15.1 Engine Removal Safing, Rigging, Hoisting & Disconnects 15.2 Overhaul Stages, Cleaning, NDT & Dimensional Inspection Limits 15.3 Engine Installation, Vibration Isolators, Run-Up & Break-In 15.4 Engine Preservation, Storage & Depreservation 15.5 Turbine Engine Trimming & Post-Installation Procedures

16 Chapter 16: Engine Fire Protection & Exhaust Systems

16.1 Thermal Switches, Thermocouples & Continuous-Loop Fire Detectors 16.2 Engine Fire Extinguishing Agents, Containers & Discharge Indicators 16.3 Reciprocating Exhaust Systems, Cabin Heat Muffs & Carbon Monoxide Risks 16.4 Turbine Exhaust Nozzles, Jet Pipes & Thrust Reversers

13.3 Turbine Engine Fuel Control Units: Hydromechanical & FADEC

Key Takeaways Explain This Topic AI

Turbine Fuel Control Units (FCU) schedule fuel mass flow (Wf) by continuously sensing Power Lever Angle (PLA), compressor rotor speeds (N1/N2), inlet total temperature (Tt2), and compressor discharge static pressure (Ps3 / CDP).

Compressor discharge pressure (Ps3 / CDP) is the primary parameter representing engine airflow mass, establishing the critical baseline for metering fuel to match instantaneous combustion chamber capacity.

The FCU acceleration schedule limits the rate of fuel flow increase during rapid throttle advancement to prevent compressor surge/stall and turbine over-temperature, while the deceleration schedule enforces a fuel floor to prevent lean flameout.

Hydromechanical FCUs compute schedules using 3D contoured cams, flyweight governors, and pressure bellows, whereas modern FADEC systems utilize dual-channel Electronic Engine Controllers (EECs) with hot-standby redundancy.

FADEC systems achieve complete electrical independence from airframe bus failures by drawing power from an engine-driven Permanent Magnet Alternator (PMA) mounted on the accessory gearbox.

Last updated: September 2026

13.3 Turbine Engine Fuel Control Units: Hydromechanical & FADEC

Quick Answer: The Turbine Engine Fuel Control Unit (FCU) meters fuel mass flow ( W f W_f W f ​ ) in pounds per hour to deliver demanded thrust while keeping the powerplant strictly within thermodynamic and mechanical limits. Unlike piston carburetors, an FCU must compute fuel flow based on multiple simultaneous variables: Power Lever Angle (PLA) , compressor speeds ( N 1 / N 2 N_1/N_2 N 1 ​ / N 2 ​ ) , compressor inlet temperature ( T t 2 T_{t2} T t 2 ​ ) , and compressor discharge static pressure ( P s 3 P_s3 P s ​ 3 or CDP) . P s 3 P_s3 P s ​ 3 is the single most critical parameter representing actual combustor mass airflow. To protect the engine, the FCU enforces an acceleration schedule (limits fuel enrichment rate during rapid throttle advance to prevent compressor stall and turbine over-temperature / hot starts ) and a deceleration schedule (maintains a minimum fuel flow floor during rapid throttle chops to prevent lean flameout ). Older powerplants employ hydromechanical FCUs utilizing 3D cams, bellows, and flyweight governors. Modern engines utilize Full Authority Digital Engine Control (FADEC) featuring dual-channel Electronic Engine Controllers (EECs) powered independently by an engine-driven Permanent Magnet Alternator (PMA) with automatic reversionary backup modes and Built-In Test Equipment (BITE) .

The Turbine Fuel Metering Challenge: Mass Flow Scheduling ( W f W_f W f ​ )

In a gas turbine engine, thrust is generated by accelerating a continuous mass flow of air through the core and fan ducts: F = m ˙ ( V j − V a ) F = \dot{m}(V_j - V_a) F = m ˙ ( V j ​ − V a ​ ) . Because air density varies drastically with flight altitude, outside air temperature, and airspeed, the volumetric airflow entering the combustion chambers changes constantly. A simple mechanical valve linked to the cockpit throttle would destroy a turbine engine within minutes: The Multi-Variable Metering Matrix

  • Pilot Command (PLA) -----------------------+
  • Compressor Speed (N1 / N2) ---------------+ |
  • Inlet Air Temperature (Tt2) --------------+ |
  • Compressor Discharge Pressure (Ps3 / CDP) -+ ===> [ TURBINE FUEL CONTROL ]
  • Exhaust Gas Temp / ITT (Turbine Limits) --+ | (FCU / FADEC)
  • Ambient Static Pressure (Pamb) -----------+ | |
  • v v
  • Metered Fuel Mass Flow (Wf in lb/hr)
  • Primary Sensed Parameters

Power Lever Angle (PLA): The pilot's thrust demand commanded through cockpit throttle quadrant levers. In hydromechanical systems, this is a mechanical cable/pushrod linkage; in FADEC, it is sensed by redundant Rotary Variable Differential Transformers (RVDTs) or potentiometers.

Compressor Spool Speeds ( N 1 N_1 N 1 ​ and N 2 N_2 N 2 ​ ): Measured in percent of maximum rated RPM. Tachometer pulse generators or magnetic reluctance pickups sense the rotational speeds of the low-pressure spool ( N 1 N_1 N 1 ​ fan/compressor) and high-pressure spool ( N 2 N_2 N 2 ​ core compressor).

Compressor Inlet Total Temperature ( T t 2 T_{t2} T t 2 ​ ): Sensed by a platinum resistance bulb or liquid-filled thermal probe in the engine inlet. T t 2 T_{t2} T t 2 ​ reflects air density; colder inlet air is denser, requiring more fuel mass to maintain the desired fuel-air ratio.

Compressor Discharge Static Pressure ( P s 3 P_s3 P s ​ 3 or CDP / P t 4 P_t4 P t ​ 4 ): Sensed at the diffuser exit immediately ahead of the combustor liner. P s 3 P_s3 P s ​ 3 is the single most vital operational parameter in turbine fuel scheduling. It directly indicates the actual mass airflow and density of air compressed and ready for combustion.

Turbine Temperature Limits ( E G T EGT EGT / I T T ITT I TT / T I T TIT T I T ): Exhaust Gas Temperature, Interstage Turbine Temperature, or Turbine Inlet Temperature sensed by chromel-alumel thermocouple harnesses. The FCU trims fuel flow back if temperatures approach metallurgical thermal creep limits.

Transient Fuel Scheduling: Acceleration & Deceleration Physics

During steady-state cruise, the FCU simply balances fuel flow against aerodynamic drag and friction to maintain a constant rotor RPM or engine pressure ratio (EPR). The true complexity of an FCU occurs during transient throttle movements : Transient Fuel Metering & Safety Schedules

  • Fuel Flow (Wf)
  • ^
  • | / [ ACCELERATION SCHEDULE ]
  • | / (Surge / Stall & Hot Start Boundary)
  • | /
  • | / <-- Rapid Throttle Advance (Meters along schedule)
  • | +--------------+
  • | | STEADY-STATE |
  • | +--------------+
  • | \ <-- Rapid Throttle Chop (Meters along schedule)
  • | \
  • | \ [ DECELERATION SCHEDULE ]
  • | (Lean Flameout Boundary)
  • +---------------------------------------------------------> Rotor Speed (N2)
  • 1. Acceleration Scheduling: Preventing Compressor Stall & Hot Starts

When a pilot rapidly shoves the throttle forward from flight idle to maximum takeoff thrust, induction air cannot accelerate instantaneously. The heavy titanium and nickel compressor and turbine rotors possess significant physical inertia, requiring several seconds to spool up to full RPM:

The Stall Phenomenon: If the FCU injected the full amount of fuel demanded by the forward throttle lever position immediately, a massive volume of hot combustion gas would be generated while compressor speed was still low. The excessive backpressure inside the combustor would reverse the pressure gradient across the rear compressor stages. Airflow would detach from the compressor blades, plunging the engine into violent compressor stall and compressor surge (loud bangs, violent airframe shaking, and total loss of thrust).

The Over-Temperature (Hot Start / Over-Temp) Hazard: Over-fueling a low-speed compressor produces an excessively rich fuel-air ratio with inadequate cooling bypass air. Combustion temperatures immediately spike well above 1,000°C–1,200°C, causing severe turbine blade untwisting, thermal creep, nozzle guide vane burning, or complete turbine disc failure .

The Acceleration Limiter: The FCU incorporates an internal acceleration schedule that limits the maximum allowable rate of fuel flow increase (dW_f / dt) as a direct mathematical function of P s 3 P_s3 P s ​ 3 (CDP) and rotor speed ( N 2 N_2 N 2 ​ ). As the compressor slowly spools up and P s 3 P_s3 P s ​ 3 rises, the FCU smoothly meters more fuel, accelerating the engine along its optimum aerodynamic acceleration curve without surging or overheating.

2. Deceleration Scheduling: Preventing Lean Flameout

Conversely, when a pilot abruptly yanks the power lever back from full takeoff power to idle during an aborted takeoff or rapid descent:

The Lean Flameout Phenomenon: Air continues rushing through the high-speed rotating compressor at massive flow rates due to rotor momentum. If the FCU cut fuel flow instantly to the low idle setting, the fuel-air mixture inside the combustor would instantly become excessively lean (leaner than ~30:1 by weight), exceeding the lean flammability limit .

Engine Extinction: The combustion flame would literally blow out, causing an uncommanded lean flameout . The engine core ceases firing, requiring an inflight windmill or starter restart.

The Deceleration Limiter: The FCU deceleration schedule enforces a minimum fuel flow floor (often governed by a minimum pressure valve or deceleration metering slot). Fuel flow is reduced only at a rate that allows the compressor to spool down while maintaining continuous combustion flame stability in the burner cans.

Hydromechanical Fuel Control Units (HFCU)

Before digital microprocessors, turbine engines relied on hydromechanical fuel controls —extraordinarily complex analog mechanical computers that used hydraulic servos, spring forces, and pneumatic pressures to compute metering schedules. Hydromechanical FCU Internal Computing Architecture

  • +-------------------------------------------------------------------------+
  • | 1. SPEED-SENSING GOVERNOR SECTION |
  • | - Rotating flyweights driven by N2 accessory gear shaft. |
  • | - Centrifugal force opposes pilot speeder spring force. |
  • | - Displaces pilot servo valve to reposition main fuel metering valve. |
  • +-------------------------------------------------------------------------+
  • |
  • v
  • +-------------------------------------------------------------------------+
  • | 2. 3-DIMENSIONAL (3D) CONTOURED CAM & BELLOWS SECTION |
  • | - 3D Cam rotates based on engine RPM (N2). |
  • | - 3D Cam translates axially based on inlet temperature (Tt2). |
  • | - Stylus follower traces 3D cam surface to mechanically compute fuel! |
  • | - Evacuated aneroid bellows compensates for altitude (Pamb). |
  • | - Pressure bellows senses compressor discharge pressure (Ps3/CDP). |
  • +-------------------------------------------------------------------------+
  • |
  • v
  • +-------------------------------------------------------------------------+
  • | 3. METERING & PRESSURIZING VALVE SECTION |
  • | - Main Metering Valve: Varies orifice area to set fuel flow. |
  • | - Pressure Regulating Valve: Maintains constant differential (delta-P) |
  • | across the metering valve so flow is strictly proportional to area. |
  • | - Pressurizing & Dump (P&D) Valve: Opens primary/secondary manifolds |
  • | and dumps manifold fuel overboard on shutdown to prevent coking. |
  • +-------------------------------------------------------------------------+
  • Core Mechanical Components

Flyweight Governors: A mechanical governor driven by the engine accessory drive. Spinning flyweights generate centrifugal force that balances against the tension of a cockpit-controlled speeder spring . If engine speed exceeds the commanded setpoint, the flyweights fly outward, lifting a pilot servo valve that reduces fuel flow to restore on-speed operation.

The 3-Dimensional (3D) Cam: The computational heart of hydromechanical units (such as the Bendix DP-F2 or Hamilton Standard JFC series). The 3D cam is a precision-machined, three-dimensionally contoured steel cam:

Rotation: Geared to rotate proportionally with engine core speed ( N 2 N_2 N 2 ​ ).

Axial Translation: Mechanically slid back and forth along its longitudinal axis by a hydraulic piston responding to compressor inlet temperature ( T t 2 T_{t2} T t 2 ​ ).

Cam Follower (Stylus): A hardened roller stylus rides on the complex 3D surface. The three-dimensional height of the cam surface at that specific coordinate represents the exact allowable fuel limit. The stylus mechanically repositions the fuel metering valve or limits its maximum travel during acceleration.

Bellows Assemblies: Evacuated aneroid bellows (sealed vacuum capsules) expand as ambient static pressure drops with altitude, automatically leaning the fuel schedule. Differential pressure bellows sense P s 3 P_s3 P s ​ 3 across an internal diaphragm, directly repositioning the acceleration limiter.

Pressurizing and Dump (P&D) Valve: Located downstream of the FCU:

Pressurizing Function: Contains a spring-loaded poppet that remains closed until fuel pressure reaches 40–80 psi. This ensures sufficient servo operating pressure inside the FCU before fuel is discharged into the combustor, and divides flow between primary nozzles (low-speed starting/idle) and secondary nozzles (high-power cruise/takeoff).

Dump Function: When the engine is shut down, the P&D valve snaps shut, simultaneously opening a drain port that vents the fuel manifold lines to an overboard drain or holding ecology tank. This empties residual fuel from the hot engine manifold, preventing fuel from boiling inside the nozzles and forming coke (hard carbon baked on nozzle tips) , which distorts the combustion spray pattern.

Full Authority Digital Engine Control (FADEC)

Modern commercial airliners and high-performance military aircraft replace hydromechanical linkages, cams, and bellows with Full Authority Digital Engine Control (FADEC) . "Full Authority" signifies that the digital computer has complete, uninhibited control over all engine operating parameters—there are no manual mechanical reversion levers or throttle override cables in the cockpit. Dual-Channel FADEC Architecture & Interfaces

  • +-------------------------------------------------------------------------+
  • | COCKPIT THRUST LEVER (Redundant RVDT Sensors) |
  • +-------------------------------------------------------------------------+
  • | |
  • Channel A Data| |Channel B Data
  • v v
  • =========================================================================
  • | ELECTRONIC ENGINE CONTROLLER (EEC / ECU) |
  • | +---------------------------+ +-------------------------------+ |
  • | | CHANNEL A PROCESSOR | <-> | CHANNEL B PROCESSOR | |
  • | | (Active in Control) | | (Hot Standby Backup) | |
  • | +---------------------------+ +-------------------------------+ |
  • | - Cross-Talk Data Bus - Real-Time Fault Diagnostics (BITE)|
  • | - Control Output Logic - Seamless Millisecond Transfer | |
  • =========================================================================
  • ^ ^ ^
  • | | |
  • +----+-----+ +----+----+ +----+----+
  • | DEDICATED| | ENGINE | | TORQUE | ===> Metering Valve
  • | PMA POWER| | SENSORS | | MOTOR / | Position &
  • | (Gearbox)| |(Tt2/Ps3)| | EHSV | Nozzle Flow
  • +----------+ +---------+ +---------+
  • Architecture of the Electronic Engine Controller (EEC)

The computational center of FADEC is the Electronic Engine Controller (EEC) or Engine Control Unit (ECU) :

Dual-Channel Redundancy: Every aviation FADEC system incorporates two completely separate, galvanically isolated digital computing channels—designated Channel A and Channel B . Each channel possesses its own microprocessors, power conditioning supplies, input sensor conditioning circuitry, and output driver transistors.

Active vs. Standby Operating Logic: Under normal flight, one channel is designated as the active channel (in control) , driving the electro-hydraulic servo valves (EHSV) and torque motors, while the other operates in hot standby , continuously running identical calculations and monitoring engine sensors.

Seamless Channel Transfer: The two channels communicate continuously via a high-speed cross-talk data bus. If the internal diagnostics of Channel A detect an internal processor crash, power supply dip, or failed sensor, control transfers to Channel B automatically within milliseconds without the slightest glitch in engine thrust, RPM, or flight deck indication.

Self-Contained Electrical Power: The Permanent Magnet Alternator (PMA)

Because FADEC has full authority over the engine, an airframe electrical failure must never be allowed to shut down an engine:

Gearbox-Driven PMA: Each engine incorporates a dedicated Permanent Magnet Alternator (PMA) mounted directly on the engine accessory gearbox, driven mechanically by the high-pressure spool ( N 2 N_2 N 2 ​ ).

Independent Power Generation: The PMA features dual isolated stator windings supplying independent AC power directly to Channel A and Channel B of the EEC. Once the engine spools above approximately 10% to 15% N2 during start, the PMA generates all electrical power required to operate the microprocessors, sensor excitation circuits, and electro-hydraulic torque motors.

Complete Airframe Isolation: If the aircraft experiences a catastrophic dual-generator failure, loss of all main AC and DC electrical buses, and complete battery depletion, the engine will continue running normally powered entirely by its own internal PMA.

Built-In Test Equipment (BITE) & Reversionary Modes

Continuous BITE Monitoring: The EEC continuously interrogates internal memory, sensor input signals (checking for open circuits, grounds, or out-of-range voltages), and actuator feedback position sensors (LVDTs - Linear Variable Differential Transformers). Any anomaly is flagged and recorded as a maintenance fault code in non-volatile memory for retrieval by AMT technicians upon landing.

Soft Reversionary Mode: If a single secondary sensor fails (such as an inlet temperature T t 2 T_{t2} T t 2 ​ sensor), the active channel does not shut down or disconnect. Instead, it enters a soft reversionary mode , synthesizing the missing data value using pre-programmed aerodynamic tables, airspeed, altitude, and remaining intact sensors.

Hard Reversionary Mode: If primary control sensors fail (such as loss of both P s 3 P_s3 P s ​ 3 sensors), the system drops into a hard reversionary mode (such as Alternate N1 Control). In this mode, the EEC no longer modulates thrust based on calculated engine pressure ratio (EPR), but defaults to a baseline mechanical relationship based on N1 fan speed. The pilot receives an engine control amber caution light on the EICAS/ECAM display and manually manages thrust according to AFM emergency charts.

Comparative Matrix: Hydromechanical FCU vs. Dual-Channel FADEC

Design Parameter Hydromechanical Fuel Control (HFCU) Full Authority Digital Engine Control (FADEC)

Computing Medium Analog mechanical (3D cams, levers, bellows) Digital microprocessors (32-bit/64-bit dual CPUs)

Sensing Mechanisms Rotating flyweights, fluid capillary bulbs, diaphragms Electronic pressure transducers, thermocouples, RTDs

Actuation Method Hydraulic pilot valves, mechanical linkages, servos Torque motors, Electro-Hydraulic Servo Valves (EHSV)

Cockpit Interface Mechanical push-pull cables and bellcranks Redundant electrical wiring (Fly-By-Wire RVDT signals)

Redundancy Level Single mechanical computing channel Dual independent channels (Channel A & Channel B)

Electrical Dependence None (100% mechanical/hydraulic operation) Independent engine-driven Permanent Magnet Alternator

Engine Protection Fixed acceleration boundary machined on 3D cam Dynamic active monitoring; automatic stall/temp limits

Fuel Efficiency Lower (wide safety margins required for cam tolerances) Optimized (continuous real-time thermodynamic trim)

Maintenance Diagnostic Manual bench testing; dial indicator measurements BITE fault code interrogation via flight deck display

Summary of Key Turbine Fuel Control Parameters

Sensor Parameter Symbol / Location Primary Metering & Governance Role

Power Lever Angle PLA / Cockpit Throttle Quadrant Commands steady-state thrust target; sets speeder spring or EEC demand

Compressor Rotor Speed N 1 N_1 N 1 ​ (Low) & N 2 N_2 N 2 ​ (High Spool) Senses centrifugal governor speed; provides baseline spool rate for scheduling

Compressor Inlet Temp T t 2 T_{t2} T t 2 ​ / Engine Inlet Bullet / Cowl Measures ambient air density; translates 3D cam or applies EEC density trim

Compressor Discharge Press P s 3 P_s3 P s ​ 3 / CDP / Combustor Diffuser Primary air mass flow indicator ; establishes critical acceleration schedule

Turbine Gas Temperature ITT / EGT / Turbine Guide Vanes Senses thermal limits; triggers automatic fuel trim to prevent blade creep

Independent Prep Note