Study guide
7.2 Airframe Electrical Power, Wiring, and Protection
FAA A&P Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Orientation: Eligibility, FTN, Authorization, Three-Test Path, and Retakes
1.1 Certificate Ratings and the Three-Test Roadmap 1.2 Baseline Eligibility and the Experience Path 1.3 AMTS and Military Eligibility Pathways 1.4 FTN, IACRA, and the Authorization File 1.5 Knowledge-Test Logistics and Scoring 1.6 AKTRs, Retakes, and the DME Transition
2 ACS Map, Testing Matrix, Embedded Images, Supplements, and Study Workflow
2.1 Testing Matrix Facts for AMG, AMA, and AMP 2.2 ACS Map and Subject-Area Boundaries 2.3 AKTR ACS-Code Diagnostics 2.4 Testing Supplement and Embedded Images 2.5 Three-Test Study Workflow 2.6 Final Review and Test-Day Source Control
3 General I: Electricity, Drawings, Weight and Balance, Math, and Physics
3.1 Electricity and Electronics Foundations 3.2 AC/DC Measurement and Schematic Troubleshooting 3.3 Aircraft Drawings, Blueprints, and Schematics 3.4 Weight and Balance Equations and Records 3.5 Maintenance Math and Unit Discipline 3.6 Physics for Aviation: Forces, Fluids, and Flight
4 General II: Lines, Materials, Servicing, Corrosion, Records, Inspection, and Human Factors
4.1 Fluid Lines, Fittings, and Installation Risk 4.2 Materials, Hardware, and Process Control 4.3 Ground Operations, Servicing, and Ramp Safety 4.4 Cleaning, Corrosion Control, and Finishing 4.5 Regulations, Forms, Records, and Publications 4.6 Inspection Concepts, Human Factors, and Maintenance Judgment
5 Airframe I: Structures, Flight Controls, and Airframe Inspection
5.1 Metallic Structure Inspection and Damage Patterns 5.2 Sheet-Metal Repairs, Fasteners, and Riveting Judgment 5.3 Non-Metallic Structures: Composites, Wood, Fabric, and Plastics 5.4 Flight Control Systems, Rigging, and Travel 5.5 Control Surface Balance, Flutter, and Freeplay 5.6 Airframe Inspection, Records, ADs, and Corrosion Decisions
6 Airframe II: Landing Gear, Hydraulics, Pneumatics, Environmental, Instruments, and Comms
6.1 Landing Gear, Wheels, Tires, and Brakes 6.2 Retraction, Steering, Anti-Skid, and Warning Systems 6.3 Hydraulic Systems: Components, Fluids, and Troubleshooting 6.4 Pneumatic, Vacuum, and Bleed-Air Systems 6.5 Environmental Systems: Pressurization, Heating, Cooling, and Oxygen 6.6 Instrument Systems: Pitot-Static, Gyros, and Displays 6.7 Communication, Navigation, Antennas, and Avionics Inspection
7 Airframe III: Fuel, Electrical, Ice/Rain, Fire, Rotorcraft, and Water/Waste Systems
7.1 Airframe Fuel System Boundaries and Safe Servicing 7.2 Airframe Electrical Power, Wiring, and Protection 7.3 Ice and Rain Control System Inspection and Limits 7.4 Airframe Fire Protection Detection, Extinguishing, and Squib Safety 7.5 Rotorcraft Fundamentals, Controls, Drives, and Vibration 7.6 Water and Waste Systems Service Boundaries and Contamination Control
8 Powerplant I: Reciprocating, Turbine Engine Theory, and Engine Inspection
8.1 Reciprocating Engine Cycles, Components, and Operating Boundaries 8.2 Horizontally Opposed and Radial Engine Components 8.3 Reciprocating Engine Performance, Ground Operation, and Preservation 8.4 Turbine Engine Airflow, Sections, and Performance 8.5 Turbine Engine Maintenance, FOD, Bleed Air, and Post-Installation Checks 8.6 Engine Inspection, Records, Compression, Borescope, and Airworthiness
9 Powerplant II: Instruments, Fire, Electrical, Lubrication, Ignition, and Starting
9.1 Engine Instrument Scan and Trend Logic 9.2 Pressure, Temperature, and Flow Indications 9.3 Engine Fire Protection, Detection, and Extinguishing 9.4 Engine Electrical Generation and Protection 9.5 Lubrication System Flow, Pressure, and Contamination 9.6 Ignition and Starting Troubleshooting
10 Powerplant III: Fuel Metering, Induction, Cooling, Turbine Air, Exhaust, Reversers, and Propellers
10.1 Engine Fuel System Flow, Contamination, and Vapor 10.2 Carburetors, Fuel Injection, and Metering Logic 10.3 Reciprocating Induction, Turbocharging, and Cooling 10.4 Turbine Air Systems, Bleed Air, and Anti-Ice 10.5 Exhaust Systems, Thrust Reversers, and Temperature Patterns 10.6 Propeller Systems, Governors, and Inspection
11 Oral/Practical Bridge: AKTR ACS Codes, DME Expectations, and Maintenance Judgment
11.1 Turn AKTR ACS Codes Into an Oral and Practical Remediation Plan 11.2 What the DME Oral Exam Is Really Testing 11.3 Practical Projects, Tools, Equipment, and Safety Discipline 11.4 Risk Management and Human Factors in the DME Environment 11.5 Documentation, Maintenance Records, and Data Discipline 11.6 Return-to-Service Judgment and Final DME Readiness
12 Final Review: Test Day Strategy, Three-Test Schedule, and Next Steps
12.1 Build the Final Study Calendar Around AMG, AMA, and AMP 12.2 PSI Test-Day Checklist Without Guesswork 12.3 Pacing for the 60-Question and 100-Question Knowledge Tests 12.4 Formula, Supplement, and Embedded-Image Final Review 12.5 Retake Decision Tree After a Failed or Weak Knowledge Test 12.6 DME Scheduling and Post-Pass Next Steps
7.2 Airframe Electrical Power, Wiring, and Protection
Key Takeaways Explain This Topic AI
Light aircraft typically use a 14-volt (12-V battery) or 28-volt (24-V battery) DC system with an engine-driven alternator or generator and a bus bar distribution point.
Circuit protection (breakers/fuses) is sized to protect the WIRE, not the load; never upsize a breaker to stop nuisance trips without approved data.
Wire is sized by American Wire Gauge — the SMALLER the AWG number, the LARGER the conductor; selection accounts for current, allowable voltage drop, length, and bundle/ambient temperature.
Bonding and shielding must be restored after maintenance so static, lightning, and EMI protection remain effective.
Last updated: October 2026
Generation, the Bus, and the Battery
Airframe electrical systems include DC and AC generation, voltage regulation, batteries, distribution buses, lighting, wiring, connectors, switches, circuit protection, bonding, shielding, and measurement. The exam may show a simple fault, but the safe mechanic sees the whole path: current leaves a source, passes through protection and control, reaches a load, and returns through ground or a return conductor.
Most light aircraft use a 14-volt system (12-volt battery) or a 28-volt system (24-volt battery); the charging source runs about 1–2 volts above battery voltage so the battery charges. An alternator produces AC internally and rectifies it to DC; it is lighter, produces useful output at low engine RPM, and is the modern standard. A DC generator produces DC directly through a commutator but needs higher RPM for output. A voltage regulator holds output voltage steady across engine speed and load.
Large turbine aircraft commonly use 115-volt, 400-Hz AC generators, with a transformer-rectifier (TR) unit producing 28-volt DC for DC loads and an inverter producing AC from DC for emergency/instrument loads.
The bus bar is the common metal strip from which power is distributed; loads tap off the bus through individual circuit protectors. Buses are often split (main, essential/battery, avionics) so critical loads can be isolated. The battery supplies starting current, provides backup if the generator fails, and dampens voltage transients. When a symptom appears, identify the source and the affected bus first — do not chase a single landing light if the entire bus is dead.
- Element Typical fault Safe check
- Alternator/generator Low or no output, poor regulation Measure output vs. limits with approved meter
- Bus bar Whole-bus loss of power Check feed, tie relays, protection upstream
- Battery Won't start, won't hold charge Capacity/load test, electrolyte/cell check
- Protection device Open breaker, nuisance trip Find the CAUSE before resetting
- Inverter / TR unit No AC / no converted DC Verify input power and output by procedure
Wire Sizing, Protection, and Bonding
Wire is sized by American Wire Gauge (AWG) — and the counter-intuitive rule the test loves is that the smaller the AWG number, the larger the conductor . Heavy primary cables (battery, starter, alternator, bus feeders) run 8 AWG down to 00 AWG; small instrument and lighting circuits use 18–22 AWG.
Selection depends on the current carried, the allowable voltage drop (continuous-load circuits permit a smaller drop than intermittent ones), conductor length, insulation temperature rating, and whether the wire is bundled or in free air (bundled wire derates because heat cannot escape). Routing and securing protect wire from chafing, fluid, heat, and vibration; clamps and grommets are inspection items.
Circuit protection protects the wire, not the load. A breaker or fuse opens before the conductor overheats and ignites. This is why installing a higher-rated breaker to stop a nuisance trip is unsafe — it lets the wire carry more current than its insulation can survive. Circuit breakers can be reset (and are "trip-free," meaning they trip even if the button is held), while fuses must be replaced; spare fuses (commonly 50% of each rating, at least one) are carried. Find the cause of a trip before resetting; repeated resetting of a tripped breaker is poor practice and can start a fire.
- Protection topic Rule
- Sizing Protects the wire/insulation, not the load
- Upsizing Not allowed without approved data
- Breaker vs. fuse Breaker resets; fuse replaces; breakers are trip-free
- Reset discipline Find cause first; do not cycle a tripped breaker
Connectors, splices, terminals, and soldering matter because small workmanship errors cause large faults. A poor crimp creates resistance and heat; a loose terminal gives intermittent failures under vibration; excess solder wicks up stranded wire and creates a stiff stress point that fatigue-cracks; wrong flux promotes corrosion. Bonding jumpers provide a low-resistance path so all metal parts share one potential — this carries static off the airframe, gives lightning a controlled path, and provides an EMI-quiet ground for radios.
Shielding drains electromagnetic interference. Both must be reconnected after any repair. Finally, respect energized-circuit hazards: de-energize and tag when practical, and be cautious with external power, where wrong polarity or voltage can damage equipment and arcing can injure personnel.
Ohm's Law and the Electrical Load
The Airframe test assumes the General-level math. Ohm's law is E = I × R (voltage = current × resistance), and power is P = E × I . Worked example: a 28-volt landing light draws 7 amps. Its resistance is R = E ÷ I = 28 ÷ 7 = 4 ohms , and it consumes P = E × I = 28 × 7 = 196 watts . To protect that circuit you would choose the next standard breaker above the 7-amp continuous load (and size the wire for 7 A at the run length and allowable voltage drop).
In a series circuit current is the same everywhere and resistances add; in a parallel circuit voltage is the same across each branch and the total resistance is less than the smallest branch. Most aircraft loads hang in parallel off the bus, which is why one failed lamp does not kill the others.
The electrical load must be managed against the generator/alternator rating. The mechanic (and an electrical load analysis) totals continuous loads, intermittent loads, and the battery charge demand and confirms the charging source can carry them with margin. An ammeter shows charge/discharge (or total load), and a loadmeter shows the fraction of rated output in use. If the load exceeds generation, the battery discharges and bus voltage falls.
When troubleshooting, read whether one load or many loads are affected to locate the fault: many loads on one bus point to a source, bus-feed, or protection fault, while a single load points to its own branch — control, wiring, ground, or load. Never repair an aircraft wire with an automotive connector or unapproved splice; restore the approved design.