Study guide

4.4 Cleaning, Corrosion Control, and Finishing

FAA A&P Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Orientation: Eligibility, FTN, Authorization, Three-Test Path, and Retakes

1.1 Certificate Ratings and the Three-Test Roadmap 1.2 Baseline Eligibility and the Experience Path 1.3 AMTS and Military Eligibility Pathways 1.4 FTN, IACRA, and the Authorization File 1.5 Knowledge-Test Logistics and Scoring 1.6 AKTRs, Retakes, and the DME Transition

2 ACS Map, Testing Matrix, Embedded Images, Supplements, and Study Workflow

2.1 Testing Matrix Facts for AMG, AMA, and AMP 2.2 ACS Map and Subject-Area Boundaries 2.3 AKTR ACS-Code Diagnostics 2.4 Testing Supplement and Embedded Images 2.5 Three-Test Study Workflow 2.6 Final Review and Test-Day Source Control

3 General I: Electricity, Drawings, Weight and Balance, Math, and Physics

3.1 Electricity and Electronics Foundations 3.2 AC/DC Measurement and Schematic Troubleshooting 3.3 Aircraft Drawings, Blueprints, and Schematics 3.4 Weight and Balance Equations and Records 3.5 Maintenance Math and Unit Discipline 3.6 Physics for Aviation: Forces, Fluids, and Flight

4 General II: Lines, Materials, Servicing, Corrosion, Records, Inspection, and Human Factors

4.1 Fluid Lines, Fittings, and Installation Risk 4.2 Materials, Hardware, and Process Control 4.3 Ground Operations, Servicing, and Ramp Safety 4.4 Cleaning, Corrosion Control, and Finishing 4.5 Regulations, Forms, Records, and Publications 4.6 Inspection Concepts, Human Factors, and Maintenance Judgment

5 Airframe I: Structures, Flight Controls, and Airframe Inspection

5.1 Metallic Structure Inspection and Damage Patterns 5.2 Sheet-Metal Repairs, Fasteners, and Riveting Judgment 5.3 Non-Metallic Structures: Composites, Wood, Fabric, and Plastics 5.4 Flight Control Systems, Rigging, and Travel 5.5 Control Surface Balance, Flutter, and Freeplay 5.6 Airframe Inspection, Records, ADs, and Corrosion Decisions

6 Airframe II: Landing Gear, Hydraulics, Pneumatics, Environmental, Instruments, and Comms

6.1 Landing Gear, Wheels, Tires, and Brakes 6.2 Retraction, Steering, Anti-Skid, and Warning Systems 6.3 Hydraulic Systems: Components, Fluids, and Troubleshooting 6.4 Pneumatic, Vacuum, and Bleed-Air Systems 6.5 Environmental Systems: Pressurization, Heating, Cooling, and Oxygen 6.6 Instrument Systems: Pitot-Static, Gyros, and Displays 6.7 Communication, Navigation, Antennas, and Avionics Inspection

7 Airframe III: Fuel, Electrical, Ice/Rain, Fire, Rotorcraft, and Water/Waste Systems

7.1 Airframe Fuel System Boundaries and Safe Servicing 7.2 Airframe Electrical Power, Wiring, and Protection 7.3 Ice and Rain Control System Inspection and Limits 7.4 Airframe Fire Protection Detection, Extinguishing, and Squib Safety 7.5 Rotorcraft Fundamentals, Controls, Drives, and Vibration 7.6 Water and Waste Systems Service Boundaries and Contamination Control

8 Powerplant I: Reciprocating, Turbine Engine Theory, and Engine Inspection

8.1 Reciprocating Engine Cycles, Components, and Operating Boundaries 8.2 Horizontally Opposed and Radial Engine Components 8.3 Reciprocating Engine Performance, Ground Operation, and Preservation 8.4 Turbine Engine Airflow, Sections, and Performance 8.5 Turbine Engine Maintenance, FOD, Bleed Air, and Post-Installation Checks 8.6 Engine Inspection, Records, Compression, Borescope, and Airworthiness

9 Powerplant II: Instruments, Fire, Electrical, Lubrication, Ignition, and Starting

9.1 Engine Instrument Scan and Trend Logic 9.2 Pressure, Temperature, and Flow Indications 9.3 Engine Fire Protection, Detection, and Extinguishing 9.4 Engine Electrical Generation and Protection 9.5 Lubrication System Flow, Pressure, and Contamination 9.6 Ignition and Starting Troubleshooting

10 Powerplant III: Fuel Metering, Induction, Cooling, Turbine Air, Exhaust, Reversers, and Propellers

10.1 Engine Fuel System Flow, Contamination, and Vapor 10.2 Carburetors, Fuel Injection, and Metering Logic 10.3 Reciprocating Induction, Turbocharging, and Cooling 10.4 Turbine Air Systems, Bleed Air, and Anti-Ice 10.5 Exhaust Systems, Thrust Reversers, and Temperature Patterns 10.6 Propeller Systems, Governors, and Inspection

11 Oral/Practical Bridge: AKTR ACS Codes, DME Expectations, and Maintenance Judgment

11.1 Turn AKTR ACS Codes Into an Oral and Practical Remediation Plan 11.2 What the DME Oral Exam Is Really Testing 11.3 Practical Projects, Tools, Equipment, and Safety Discipline 11.4 Risk Management and Human Factors in the DME Environment 11.5 Documentation, Maintenance Records, and Data Discipline 11.6 Return-to-Service Judgment and Final DME Readiness

12 Final Review: Test Day Strategy, Three-Test Schedule, and Next Steps

12.1 Build the Final Study Calendar Around AMG, AMA, and AMP 12.2 PSI Test-Day Checklist Without Guesswork 12.3 Pacing for the 60-Question and 100-Question Knowledge Tests 12.4 Formula, Supplement, and Embedded-Image Final Review 12.5 Retake Decision Tree After a Failed or Weak Knowledge Test 12.6 DME Scheduling and Post-Pass Next Steps

4.4 Cleaning, Corrosion Control, and Finishing

Key Takeaways Explain This Topic AI

Galvanic corrosion needs two dissimilar metals plus an electrolyte; the more anodic (active) metal corrodes, e.g., aluminum sacrificing to a steel or carbon-composite fastener.

Intergranular corrosion attacks grain boundaries (worst in 7xxx zinc alloys); when it lifts surface grains it becomes exfoliation, a serious structural concern.

Filiform corrosion forms threadlike tracks under organic coatings at 78-90% relative humidity and a slightly acidic surface; store below 70% RH to prevent it.

Stress corrosion develops in sustained-tension parts (landing gear, crankshafts) often starting at a scratch or surface pit; pits themselves become crack-initiation sites.

Wash, treat, and conversion-coat/prime/topcoat per approved data; recheck control-surface balance after refinishing because added paint weight affects flutter resistance.

Last updated: June 2026

Corrosion Theory

Cleaning and corrosion control are not cosmetic subjects. Corrosion is the deterioration of a metal by chemical or electrochemical action, and it requires an anode, a cathode, an electrolyte, and a metal path — remove any one and the cell stops. Moisture, oxygen, salt, industrial pollutants, spilled battery electrolyte, exhaust residue, and trapped dirt all accelerate attack. A protective barrier slows corrosion, but a scratch, failed sealant, missing primer, or contaminated lap joint creates a local corrosion cell. The authoritative reference is AC 43-4B (Corrosion Control) and AC 43.13-1B Chapter 6.

The Forms of Corrosion

  • Form Clue / location Concern
  • Uniform (surface) General dulling, white powdery residue on aluminum Even loss of metal and protection
  • Pitting Small cavities/dark spots Deep, hidden; becomes a crack-initiation site
  • Intergranular Attack along grain boundaries (worst in 7xxx zinc alloys) Serious internal alloy damage
  • Exfoliation Surface grains lifted/flaked by expanding products Advanced intergranular; structural
  • Galvanic (dissimilar-metal) Two unlike metals + electrolyte Anodic metal corrodes rapidly
  • Filiform Threadlike tracks under paint/organic film Coating failure, moisture path
  • Stress Cracks in sustained-tension parts (gear, crankshaft) Often starts at a scratch/pit; can fracture

Galvanic corrosion needs dissimilar metals plus an electrolyte ; the more anodic (active) metal is sacrificed — for example, aluminum corrodes when bolted to steel or in contact with carbon-fiber composite . Intergranular attack runs along grain boundaries and is worst in 7000-series (zinc) high-strength alloys such as spars and stringers; when corrosion products lift the surface grains it becomes exfoliation , a serious structural condition.

Filiform corrosion forms wormlike threads beneath an organic coating when relative humidity is roughly 78-90% and the surface is slightly acidic; the prevention is to store the aircraft below 70% RH , use low-permeability coatings, and wash off acidic contaminants. Stress corrosion develops in highly stressed parts under sustained tension, frequently starting from a scratch or surface pit, and pitting is dangerous less for lost cross-section than because each pit becomes a fatigue-crack nucleus.

Corrosion-Prone Areas and Inspection

Corrosion inspection concentrates on prone areas where moisture and contaminants collect: battery compartments (spilled electrolyte), bilges and lower fuselage skins , wheel wells and landing gear , lavatory and galley surroundings, exhaust trail areas , lap joints and around fasteners , control-surface hinges , engine mounts , and any place where dissimilar metals meet or where water is trapped behind insulation or under floorboards.

Detection ranges from visual inspection of telltale powder, blistered paint, or stains, through magnifiers and borescopes, to NDT such as eddy current for cracks growing from corrosion pits. A surface usually must be clean before an accurate corrosion inspection is possible.

Cleaning Compatibility

Cleaning starts with material compatibility . Strong alkaline or acidic cleaners attack aluminum and magnesium and strip protective finishes; solvents can craze transparencies and acrylics or soften composite resin; abrasive blasting or wire brushing with the wrong media can gouge soft metal or embed particles that start new galvanic cells; and high-pressure water can drive contamination into bearings, seams, bushings, and electrical connectors.

Match both the product and the method to the surface — aluminum, magnesium, steel, titanium, composite, transparency, rubber, or painted finish — and protect adjacent sensitive areas, bearings, and openings before cleaning begins.

Removal, Treatment, and Coatings

Removal and treatment must follow approved data — removing too much base metal creates a structural defect , so corrosion damage is classified against the manufacturer's limits as negligible, repairable, or non-repairable , and any rework is held within the allowable depth and area.

Removal methods are matched to the metal and the corrosion severity: light surface corrosion on aluminum is removed by hand with abrasive mats, fine abrasive paper, or nylon pads and a chemical inhibitor; heavier corrosion may need controlled abrasive blasting, rotary files, or grinding within limits; magnesium requires its own gentle methods and a dichromate treatment; and steel corrosion (rust) is removed mechanically and the bare steel re-protected promptly.

After removal, the affected area must be neutralized, cleaned, and dried before any coating is applied. Excess removal that exceeds the negligible-damage limit converts a cleaning task into a repair requiring approved data.

After mechanical or chemical removal, restore the protective barrier in layers: a conversion coating (such as chromate or Alodine on aluminum, or anodize on new parts) provides corrosion resistance and a paint-bonding base; then primer (often epoxy or wash primer); then topcoat (polyurethane or enamel).

Corrosion-preventive compounds (CPC) — soft-film water-displacing types or harder waxy films — are applied into joints, recesses, faying surfaces, and box structure that paint cannot fully protect, and are reapplied on an interval set by exposure and the manufacturer's program. Finishing depends on surface prep and ambient conditions (cleaning, etching, conversion coating, correct mixing/thinning, temperature, humidity, flash time); poor control yields runs, orange peel, lifting, and poor adhesion.

Fire prevention and ventilation are critical because finishing materials are flammable and toxic — the SDS drives PPE.

Finally, refinishing affects more than appearance. Identification plates, registration marks, placards, and required markings must be protected or replaced, and control surfaces must be re-balanced after refinishing because added or uneven paint weight changes the static/dynamic balance and can reduce flutter resistance. A flawless finish is unacceptable if it leaves a control surface out of balance.