Study guide
9.6 Ignition and Starting Troubleshooting
FAA A&P Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Orientation: Eligibility, FTN, Authorization, Three-Test Path, and Retakes
1.1 Certificate Ratings and the Three-Test Roadmap 1.2 Baseline Eligibility and the Experience Path 1.3 AMTS and Military Eligibility Pathways 1.4 FTN, IACRA, and the Authorization File 1.5 Knowledge-Test Logistics and Scoring 1.6 AKTRs, Retakes, and the DME Transition
2 ACS Map, Testing Matrix, Embedded Images, Supplements, and Study Workflow
2.1 Testing Matrix Facts for AMG, AMA, and AMP 2.2 ACS Map and Subject-Area Boundaries 2.3 AKTR ACS-Code Diagnostics 2.4 Testing Supplement and Embedded Images 2.5 Three-Test Study Workflow 2.6 Final Review and Test-Day Source Control
3 General I: Electricity, Drawings, Weight and Balance, Math, and Physics
3.1 Electricity and Electronics Foundations 3.2 AC/DC Measurement and Schematic Troubleshooting 3.3 Aircraft Drawings, Blueprints, and Schematics 3.4 Weight and Balance Equations and Records 3.5 Maintenance Math and Unit Discipline 3.6 Physics for Aviation: Forces, Fluids, and Flight
4 General II: Lines, Materials, Servicing, Corrosion, Records, Inspection, and Human Factors
4.1 Fluid Lines, Fittings, and Installation Risk 4.2 Materials, Hardware, and Process Control 4.3 Ground Operations, Servicing, and Ramp Safety 4.4 Cleaning, Corrosion Control, and Finishing 4.5 Regulations, Forms, Records, and Publications 4.6 Inspection Concepts, Human Factors, and Maintenance Judgment
5 Airframe I: Structures, Flight Controls, and Airframe Inspection
5.1 Metallic Structure Inspection and Damage Patterns 5.2 Sheet-Metal Repairs, Fasteners, and Riveting Judgment 5.3 Non-Metallic Structures: Composites, Wood, Fabric, and Plastics 5.4 Flight Control Systems, Rigging, and Travel 5.5 Control Surface Balance, Flutter, and Freeplay 5.6 Airframe Inspection, Records, ADs, and Corrosion Decisions
6 Airframe II: Landing Gear, Hydraulics, Pneumatics, Environmental, Instruments, and Comms
6.1 Landing Gear, Wheels, Tires, and Brakes 6.2 Retraction, Steering, Anti-Skid, and Warning Systems 6.3 Hydraulic Systems: Components, Fluids, and Troubleshooting 6.4 Pneumatic, Vacuum, and Bleed-Air Systems 6.5 Environmental Systems: Pressurization, Heating, Cooling, and Oxygen 6.6 Instrument Systems: Pitot-Static, Gyros, and Displays 6.7 Communication, Navigation, Antennas, and Avionics Inspection
7 Airframe III: Fuel, Electrical, Ice/Rain, Fire, Rotorcraft, and Water/Waste Systems
7.1 Airframe Fuel System Boundaries and Safe Servicing 7.2 Airframe Electrical Power, Wiring, and Protection 7.3 Ice and Rain Control System Inspection and Limits 7.4 Airframe Fire Protection Detection, Extinguishing, and Squib Safety 7.5 Rotorcraft Fundamentals, Controls, Drives, and Vibration 7.6 Water and Waste Systems Service Boundaries and Contamination Control
8 Powerplant I: Reciprocating, Turbine Engine Theory, and Engine Inspection
8.1 Reciprocating Engine Cycles, Components, and Operating Boundaries 8.2 Horizontally Opposed and Radial Engine Components 8.3 Reciprocating Engine Performance, Ground Operation, and Preservation 8.4 Turbine Engine Airflow, Sections, and Performance 8.5 Turbine Engine Maintenance, FOD, Bleed Air, and Post-Installation Checks 8.6 Engine Inspection, Records, Compression, Borescope, and Airworthiness
9 Powerplant II: Instruments, Fire, Electrical, Lubrication, Ignition, and Starting
9.1 Engine Instrument Scan and Trend Logic 9.2 Pressure, Temperature, and Flow Indications 9.3 Engine Fire Protection, Detection, and Extinguishing 9.4 Engine Electrical Generation and Protection 9.5 Lubrication System Flow, Pressure, and Contamination 9.6 Ignition and Starting Troubleshooting
10 Powerplant III: Fuel Metering, Induction, Cooling, Turbine Air, Exhaust, Reversers, and Propellers
10.1 Engine Fuel System Flow, Contamination, and Vapor 10.2 Carburetors, Fuel Injection, and Metering Logic 10.3 Reciprocating Induction, Turbocharging, and Cooling 10.4 Turbine Air Systems, Bleed Air, and Anti-Ice 10.5 Exhaust Systems, Thrust Reversers, and Temperature Patterns 10.6 Propeller Systems, Governors, and Inspection
11 Oral/Practical Bridge: AKTR ACS Codes, DME Expectations, and Maintenance Judgment
11.1 Turn AKTR ACS Codes Into an Oral and Practical Remediation Plan 11.2 What the DME Oral Exam Is Really Testing 11.3 Practical Projects, Tools, Equipment, and Safety Discipline 11.4 Risk Management and Human Factors in the DME Environment 11.5 Documentation, Maintenance Records, and Data Discipline 11.6 Return-to-Service Judgment and Final DME Readiness
12 Final Review: Test Day Strategy, Three-Test Schedule, and Next Steps
12.1 Build the Final Study Calendar Around AMG, AMA, and AMP 12.2 PSI Test-Day Checklist Without Guesswork 12.3 Pacing for the 60-Question and 100-Question Knowledge Tests 12.4 Formula, Supplement, and Embedded-Image Final Review 12.5 Retake Decision Tree After a Failed or Weak Knowledge Test 12.6 DME Scheduling and Post-Pass Next Steps
9.6 Ignition and Starting Troubleshooting
Key Takeaways Explain This Topic AI
A magneto is a self-contained engine-driven generator and ignition source: it needs no battery once turning, which is why a recip engine keeps running after total electrical failure.
Starting aids spin the magneto fast and retard the spark: an impulse coupling winds a spring then snaps the magnet through E-gap for a hot, late spark; a shower-of-sparks (retard-breaker) system fires a rapid series of sparks through a retard breaker.
Internal magneto timing sets the points to open at E-gap; magneto-to-engine timing sets the spark to fire at the specified crankshaft position before top dead center, verified with a timing light.
No RPM drop on a single-magneto check means the opposite magneto, the one that should be switched off, is not grounding (open P-lead or faulty switch) — it stays hot, so the engine must be treated as live.
Turbine ignition uses high-energy capacitor-discharge igniters powered only for start and relight; once self-sustaining, the igniters and starter are cut out, unlike a continuously firing magneto.
Last updated: October 2026
The Magneto and Reciprocating Ignition
A magneto is a self-contained AC generator and ignition unit driven by the engine. A rotating magnet induces a primary current; when the breaker points open, the collapsing primary field induces a high-voltage secondary pulse that the distributor routes to the correct spark plug through the ignition harness . Because the magneto makes its own electricity from engine rotation, it is independent of the aircraft battery once the engine is turning — the reason a certificated piston engine continues running after a complete electrical failure.
Aircraft use dual magnetos (left and right) firing two plugs per cylinder for redundancy and a more complete, faster burn.
Two construction types exist. A high-tension magneto generates the high voltage inside the magneto and distributes it through high-voltage leads — simple but prone to flashover/arcing in the distributor at high altitude where thin air insulates poorly. A low-tension magneto generates and distributes low voltage to individual step-up transformer coils at each cylinder, with only short high-voltage runs, reducing high-altitude flashover. Modern systems often pressurize the magneto to fight altitude arcing instead.
Starting Aids, E-Gap, and Timing
At cranking speed a plain magneto turns too slowly to make a strong spark, and its normal advanced timing would fire too early and cause kickback. Two aids solve this:
Impulse coupling — a spring-loaded coupling winds up against a stop while the engine cranks, then releases to snap the magnet rapidly through its E-gap position. This both spins the magnet fast (hot spark) and retards the spark to fire near top dead center for easy, kickback-free starting. After start, flyweights disengage the stop and the magneto runs at normal advanced timing.
Shower of sparks (retard-breaker) — a second "retard" breaker fires a rapid burst of sparks through a vibrator/booster coil during start, both retarding the spark and giving multiple ignition chances across the plug gap to light a hard-starting mixture.
Timing has two parts the ACS separates. Internal timing sets the breaker points to just open when the rotating magnet is at its E-gap (the few degrees past neutral where the magnetic flux change is greatest, producing the strongest spark). Magneto-to-engine timing then installs and times the magneto so the spark fires at the specified crankshaft angle before top dead center (e.g., 25 degrees BTDC), verified with a timing light and the engine set on the timing marks. Late timing causes high CHT and power loss; over-advanced timing invites detonation and kickback.
Spark Plugs, P-Leads, Turbine Ignition, and Starting Faults
Spark plugs foul (lead/carbon bridging the gap), erode, or short; they are rotated and gapped on a schedule, and a fouled plug shows as a single mag-check RPM drop larger than normal with roughness. The harness can short to ground or open, killing one plug. The P-lead grounds the magneto primary to shut it off; if a P-lead is open or broken , the switch cannot ground the magneto and it stays hot even with the switch OFF — every propeller must be treated as live until proven otherwise.
During a mag check, no RPM drop when one magneto is selected means the opposite magneto, the one that should be switched off, is not grounding (open P-lead or faulty switch): the engine is still firing on both, and that magneto stays hot and may fire if the propeller is turned — not a good engine.
Turbine ignition is fundamentally different: a capacitor-discharge ignition exciter stores energy and dumps high-energy sparks across surface-gap igniter plugs in the combustor — but only during start and relight . Once the engine is self-sustaining, the igniters are de-energized; there is no continuous firing like a magneto.
The start sequence is, in order: (1) starter (electric, starter-generator, or air-turbine using APU/cart/cross-bleed air) spins the compressor up to establish airflow; (2) ignition is energized; (3) fuel is introduced and lights off; (4) at self-sustaining speed the starter and ignition cut out .
Faults map to the sequence: a hung start is light-off but failure to accelerate to idle (insufficient starter air/power or low fuel); a hot start is excessive EGT/ITT during start (too much fuel, too little airflow, or a slow starter) and demands an immediate abort to protect the turbine. On recips, a kickback during start indicates the spark fired too early — a failed/incorrectly installed impulse coupling or mistimed magneto.
No-Start Logic and the Mag-Check Procedure
A reciprocating engine starts only with compression, the right fuel-air mixture, a strong spark at the right time, and adequate cranking speed . A structured no-start diagnosis tests these in turn:
- Symptom Most likely area
- Starter cranks slowly Battery, cables, ground, starter motor (electrical)
- Cranks well but no fire Ignition (P-lead grounded, dead magneto, fouled plugs, bad harness) or no fuel
- Fires then quits Mixture/fuel metering, primer, induction leak
- Backfire (intake) Lean mixture, intake valve issue, late timing
- Afterfire/exhaust backfire Rich mixture, late timing
- Kickback Spark too early — impulse coupling or magneto timing
Backfire is combustion in the induction system (lean mixture or a sticking intake valve); afterfire is burning in the exhaust (an over-rich mixture). The mag check during run-up grounds one magneto at a time: a normal small RPM drop on each, within limits and roughly equal, confirms both ignition systems. An excessive drop on one mag points to fouled plugs, a bad lead, or a weak magneto on that side; no drop means the magneto that should be switched off is not grounding (open P-lead or faulty switch), so it stays hot.
A recoverable drop that clears after a brief lean-and-burn indicates lead fouling rather than a failed part. Spark-plug servicing — rotating plugs to even out wear, gapping to spec, and torquing with a new gasket — is routine work tied to these symptoms.