Study guide
7.4 RC/RL Time Constants
FCC General Radiotelephone Operator License GROL
Track your progress as you read
Finished sections get a check mark.
1 Introduction & GROL Exam Overview
1.1 About the General Radiotelephone Operator License 1.2 Exam Format, COLEMs, FRN & Application Process
2 Element 1: Rules & Regulations
2.1 Equipment Requirements (Part 80) 2.2 License Requirements & Operator Authority 2.3 Watchkeeping & Logkeeping Duties 2.4 Log Entries & Required Records 2.5 Ship Station Control, Inspections & International Rules
3 Element 1: Communications Procedures
3.1 Bridge-to-Bridge Operations & VTS 3.2 Distress Communications & Alerting 3.3 Operating Procedures, Calling & Testing 3.4 Urgency (PAN PAN) & Safety (SECURITE) Traffic 3.5 The GMDSS Concept & Ship Responsibilities
4 Element 1: Equipment Operations
4.1 VHF Equipment Controls 4.2 MF/HF SSB Equipment Controls 4.3 DSC Operations & Equipment Faults 4.4 VHF Channel Selection & Channel Assignments 4.5 MF/HF Frequency & Emission Selection 4.6 Required Equipment Tests & On-Air Test Procedure
5 Element 1: Other Equipment & Antennas
5.1 Marine Antennas & Polarization 5.2 EPIRBs & Emergency Beacons 5.3 Power Sources, Reserve Power & Required Tests 5.4 Search and Rescue Transponders (SARTs) 5.5 Survival Craft Portable VHF (SCT) Requirements 5.6 NAVTEX & Maritime Safety Information
6 Element 3: Electrical Principles
6.1 Electrical Elements, Units & Power Types 6.2 Magnetism & Magnetic Circuits 6.3 Resistance, Capacitance & Inductance 6.4 Waveforms & Semiconductor Introduction 6.5 Materials, Corrosion & Skin Effect 6.6 AC Measurement & Conversion Factors 6.7 Conduction, Reactive Power & Maximum Power Transfer
7 Element 3: Electrical Math
7.1 Ohm's Law — Series & Parallel Circuits 7.2 Frequency, Period, Wavelength & Waveform Math 7.3 Power Relationships & Decibels 7.4 RC/RL Time Constants 7.5 Frequency Counter Accuracy, PPM & Harmonics 7.6 Impedance in Rectangular & Polar Coordinates 7.7 Regulation, Turns Ratio, Zener Bias & Conductance
8 Element 3: Circuit Components — Passives & Power Devices
8.1 Capacitors & Photoconductive Devices 8.2 Transformers, Voltage Regulators & Zener Diodes 8.3 Diodes, SCRs & Triacs
9 Element 3: Active Components — Transistors & Devices
9.1 Bipolar Junction Transistors 9.2 FETs, LEDs & Specialty Devices 9.3 Device Selection, Ratings & Thermal Design
10 Element 3: Practical Circuits — RLC, Op Amps & Schematics
10.1 R-L-C Resonant Circuits 10.2 Op Amps, PLLs, VCOs & Mixers 10.3 Reading Schematics & Signal Flow
11 Element 3: Digital Logic
11.1 Logic Gates & Boolean Functions 11.2 Flip-Flops & Sequential Elements 11.3 Multivibrators & Timing Circuits 11.4 Microprocessors & Bus Architecture 11.5 TTL Logic Families & Input Voltage Levels 11.6 Positive & Negative Logic and Truth Tables 11.7 Memory Types & Microprocessor Concepts 11.8 Counters, Prescalers, BCD & Data Converters
12 Element 3: Receivers
12.1 Receiver Theory & Superheterodyne Architecture 12.2 RF Amplifiers & Front-End Design 12.3 Filters & Detectors 12.4 Audio, Squelch & Receiver Performance Specs 12.5 Receiver Oscillators: Colpitts, Hartley & Pierce 12.6 Mixing, Image Frequencies & Spurious Products 12.7 IF Selectivity & Filter Bandwidth
13 Element 3: Transmitters
13.1 RF Amplifier Classes & Efficiency 13.2 Oscillators, Modulators & Tuning Networks 13.3 SSB Transmitters & Modern Transmitter Technology
14 Element 3: Signals, Emissions & Modulation
14.1 Amplitude & Frequency Modulation 14.2 Single-Sideband Modulation 14.3 Pulse Modulation & Emission Types
15 Element 3: Power Sources
15.1 Batteries & Energy Storage 15.2 Motors, Generators & Power Supplies
16 Element 3: Antennas & Feed Lines
16.1 Antenna Theory, Types & Patterns 16.2 Voltage, Current & Impedance on Antennas 16.3 Transmission Lines, Velocity Factor & SWR 16.4 Effective Radiated Power & Antenna Bandwidth
17 Element 3 Background: Propagation & Radio Practice
17.1 Radio Wave Propagation Modes 17.2 Multipath, Fading & Doppler Effects 17.3 Radio Practice, Interference & Good Engineering
18 Element 3: Aircraft Radio Navigation Systems
18.1 DME & VOR 18.2 ILS, ADF & ATC Transponders 18.3 Aircraft Antennas, Frequencies & Equipment Functions
19 Element 3: Installation, Maintenance & Repair
19.1 Indicating Meters & Meter Movements 19.2 Oscilloscopes & Waveform Measurement 19.3 Measurement Procedures 19.4 Installation Codes & Bonding Procedures 19.5 Frequency Standards, SINAD Meters & EMI Hunting 19.6 Spectrum Analyzers, TDRs & Service Monitors 19.7 Bench Repair Practices, ESD & Rework Tools 19.8 Systematic Troubleshooting & Field Fault Diagnosis
20 Element 3: Communications Technology & Marine Systems
20.1 Transmission Types, Coding & Multiplexing 20.2 Signal Processing, Software & Codes 20.3 Marine VHF, MF/HF & SSB-SITOR 20.4 Survival Craft Electronics, FAX & NAVTEX 20.5 NMEA 0183 & NMEA 2000 Data Networks
21 Element 3: RADAR & Satellite Systems
21.1 RADAR Theory & Pulse Fundamentals 21.2 Range, Pulse Width & PRF 21.3 Radar Antennas & Waveguides 21.4 INMARSAT Satellite Communications 21.5 RADAR Components: Magnetron, Duplexer, ATR & Synchro 21.6 RADAR Equipment, ARPA & Radiation Safety 21.7 Low Earth Orbit Systems: Iridium & COSPAS-SARSAT 21.8 GPS Satellite Navigation & DGPS
22 Element 3: RF & Electrical Safety
22.1 RF Radiation Exposure Limits 22.2 Electrical Safety Practices for Radio Technicians
23 Study Strategy & Exam Day
23.1 Study Strategy, Practice Plan & Exam Day
7.4 RC/RL Time Constants
Key Takeaways Explain This Topic AI
RC time constant τ = RC; RL time constant τ = L/R; after one τ a charging quantity reaches about 63% of its final value (or falls to about 37% when discharging)
A step response is essentially settled after about five time constants (~99% of the final change)
Impedance Z is the AC generalization of resistance; series RLC magnitude |Z| = √[R² + (XL − XC)²]; at series resonance XL = XC and |Z| is minimum and equal to R
Resonant frequency f0 = 1/(2π√(LC)); series resonance → low Z; parallel resonance → high Z (tank)
Parallel and series combinations of R, XL, and XC follow impedance network rules analogous to resistors but with complex (or j-operator) reactances
Last updated: August 2026
7.4 RC/RL Time Constants & Impedance Networks
Quick Answer: τ = RC or τ = L/R . In 1τ , charge/voltage (RC) or current (RL) moves about 63% of the way to the final value ( 37% remains when decaying). About 5τ to settle. Impedance |Z| = √[R² + (XL − XC)²] in series RLC. Resonance f0 = 1/(2π√(LC)) ; series |Z| → R only when XL = XC.
Topic 3-B finishes by connecting time-domain transients with frequency-domain impedance—exactly how radio circuits behave when you key a transmitter, charge a coupling network, or tune an LC stage.
- RC time constant
- For a resistor R and capacitor C: τ = R C \tau = R C τ = RC
- Quantity Unit
- R ohms (Ω)
- C farads (F)
- τ seconds (s)
Charging (step toward final voltage V f V_f V f on the capacitor, starting from 0): V C ( t ) = V f ( 1 − e − t / τ ) V_C(t) = V_f \left(1 - e^{-t/\tau}\right) V C ( t ) = V f ( 1 − e − t / τ )
Discharging toward zero from initial V 0 V_0 V 0 : V C ( t ) = V 0 e − t / τ V_C(t) = V_0 \, e^{-t/\tau} V C ( t ) = V 0 e − t / τ
- Time Charge (from 0 → final) Discharge (from full → 0)
- 1τ ≈ 63.2% of final ≈ 36.8% remaining
- 2τ ≈ 86.5% ≈ 13.5% remaining
- 3τ ≈ 95% ≈ 5% remaining
- 4τ ≈ 98% ≈ 2% remaining
- 5τ ≈ 99% (settled for most practical work) ≈ 1% remaining
- Worked example — pool RC value
R = 10 kΩ , C = 100 µF . Time constant? τ = ( 10 × 10 3 ) ( 100 × 10 − 6 ) = 1.0 s \tau = (10 \times 10^3)(100 \times 10^{-6}) = 1.0\,\mathrm{s} τ = ( 10 × 1 0 3 ) ( 100 × 1 0 − 6 ) = 1.0 s
After 1 s of charging from 0 toward a 12 V step, V C ≈ 0.632 × 12 ≈ 7.6 V V_C \approx 0.632 \times 12 \approx 7.6\,\mathrm{V} V C ≈ 0.632 × 12 ≈ 7.6 V . After 5 s , the capacitor is essentially at 12 V for exam purposes.
Worked example — shorter τ
R = 1 kΩ , C = 0.01 µF = 10 nF : τ = 10 3 × 10 − 8 = 10 − 5 s = 10 μ s \tau = 10^3 \times 10^{-8} = 10^{-5}\,\mathrm{s} = 10\,\mu\mathrm{s} τ = 1 0 3 × 1 0 − 8 = 1 0 − 5 s = 10 μ s
Five time constants ≈ 50 µs —typical thinking for coupling and decoupling network recovery speeds.
- RL time constant
- For inductance L and resistance R: τ = L R \tau = \frac{L}{R} τ = R L
Inductor current cannot jump; it rises or falls exponentially with the same 63%/37% and ~5τ rules, but the exponential applies to current (and to the inductor’s opposing voltage transient).
- Circuit τ Quantity that lags
- RC RC Capacitor voltage
- RL L/R Inductor current
- Worked example — RL
L = 5 H , R = 100 Ω (relay coil order-of-magnitude teaching example): τ = 5 / 100 = 0.05 s = 50 m s \tau = 5/100 = 0.05\,\mathrm{s} = 50\,\mathrm{ms} τ = 5/100 = 0.05 s = 50 ms
Current is ~63% of final after 50 ms when a DC voltage is applied; ~5τ ≈ 250 ms to settle.
Why time constants matter in radio work
Keying and AGC networks set rise/fall with RC.
Power-supply filters charge and discharge with large RC products.
Relay and inductor kickback timing tracks L/R.
Coupling capacitors pass AC while blocking DC—but after a step, the DC path settles on a τ = RC schedule.
Impedance: R, XL, XC together
Resistance R is frequency-independent (ideal). Inductive reactance: X L = 2 π f L X_L = 2\pi f L X L = 2 π f L (increases with f). Capacitive reactance: X C = 1 / ( 2 π f C ) X_C = 1/(2\pi f C) X C = 1/ ( 2 π f C ) (decreases with f).
Impedance Z is the AC ratio of voltage to current, combining resistance and reactance. In rectangular form: Z = R + j ( X L − X C ) Z = R + j(X_L - X_C) Z = R + j ( X L − X C )
Magnitude for a series combination: ∣ Z ∣ = R 2 + ( X L − X C ) 2 |Z| = \sqrt{R^2 + (X_L - X_C)^2} ∣ Z ∣ = R 2 + ( X L − X C ) 2
Phase angle: θ = tan − 1 ( X L − X C R ) \theta = \tan^{-1}\left(\frac{X_L - X_C}{R}\right) θ = tan − 1 ( R X L − X C )
- Condition Circuit behavior
- X L > X C X_L > X_C X L > X C Net inductive; current lags voltage
- X C > X L X_C > X_L X C > X L Net capacitive; current leads voltage
- X L = X C X_L = X_C X L = X C Resonant; net reactance zero
- Worked example — series impedance magnitude
At a test frequency: R = 30 Ω , XL = 40 Ω , XC = 0 (series RL): ∣ Z ∣ = 30 2 + 40 2 = 900 + 1600 = 2500 = 50 Ω |Z| = \sqrt{30^2 + 40^2} = \sqrt{900 + 1600} = \sqrt{2500} = 50\,\Omega ∣ Z ∣ = 3 0 2 + 4 0 2 = 900 + 1600 = 2500 = 50 Ω
If V_RMS = 100 V , then I = V / ∣ Z ∣ = 2 A I = V/|Z| = 2\,\mathrm{A} I = V /∣ Z ∣ = 2 A . True power = I 2 R = 120 W I^2 R = 120\,\mathrm{W} I 2 R = 120 W ; apparent power = V I = 200 V A VI = 200\,\mathrm{VA} V I = 200 VA .
Worked example — canceling reactances
R = 50 Ω , XL = 80 Ω , XC = 80 Ω : ∣ Z ∣ = 50 2 + ( 80 − 80 ) 2 = 50 Ω |Z| = \sqrt{50^2 + (80-80)^2} = 50\,\Omega ∣ Z ∣ = 5 0 2 + ( 80 − 80 ) 2 = 50 Ω
Net reactance is zero; impedance equals R only —series resonance condition.
Series vs parallel RLC at resonance
Resonant frequency (ideal series or parallel LC): f 0 = 1 2 π L C f_0 = \frac{1}{2\pi \sqrt{LC}} f 0 = 2 π L C 1
- Topology at f0 Impedance Current (given V) Use case sketch
- Series RLC Minimum → equals R Maximum Series traps, some matching
- Parallel RLC (tank) Maximum (high Z) Minimum line current Oscillator tanks, RF amplifiers
Exam hook: impedance of a series RLC circuit at resonance is equal to the resistance only (not zero unless R = 0; not equal to XL or XC alone).
Worked example — resonant frequency
L = 10 µH , C = 100 pF : L C = ( 10 × 10 − 6 ) ( 100 × 10 − 12 ) = 10 − 15 = 3.162 × 10 − 8 \sqrt{LC} = \sqrt{(10 \times 10^{-6})(100 \times 10^{-12})} = \sqrt{10^{-15}} = 3.162 \times 10^{-8} L C = ( 10 × 1 0 − 6 ) ( 100 × 1 0 − 12 ) = 1 0 − 15 = 3.162 × 1 0 − 8 f 0 = 1 2 π × 3.162 × 10 − 8 ≈ 5.03 M H z f_0 = \frac{1}{2\pi \times 3.162 \times 10^{-8}} \approx 5.03\,\mathrm{MHz} f 0 = 2 π × 3.162 × 1 0 − 8 1 ≈ 5.03 MHz
That 5.03 MHz result is a classic Element 3-style numeric. Distractors often misplace powers of ten (1.59 MHz, 15.9 MHz, 50.3 MHz).
Parallel impedance intuition (exam level)
Two pure resistances in parallel still use the resistor formula. Two pure reactances of the same type combine like parallel resistors but with j-sign bookkeeping. A parallel LC near resonance can present a very large impedance—the tank “rings” and draws little net line current at f0 (finite Q limited by losses).
For many Element 3 stems, you only need:
Series resonance → Z = R , current max.
Parallel resonance → Z high , line current min.
f 0 = 1 / ( 2 π L C ) f_0 = 1/(2\pi\sqrt{LC}) f 0 = 1/ ( 2 π L C ) for both ideal cases.
Combining networks step-by-step
Compute XL and XC at the operating frequency.
Series elements: add resistances; add reactances with sign (XL positive, XC negative in the jX sense).
Parallel elements: use reciprocal sums of complex admittances—or, for two pure equal/unlike cases, apply product-over-sum carefully.
Convert final Z to magnitude when the stem asks for ohms of impedance as a single number.
Apply Ohm’s Law for AC: (I = V / |Z|) for magnitude problems.
Bridging to later Element 3 topics
Filters and IF transformers are resonant impedance networks with Q and bandwidth (Chapter on RLC resonant circuits).
Oscillators use parallel tanks and time-constant bias networks.
Power supplies use large RC filters (τ large → more smoothing, slower recovery).
Antenna tuners cancel reactance so the transmitter sees a resistive match near 50 Ω.
Exam-day checklist for §7.4
τ = RC or L/R — units must produce seconds.
1τ → ~63% / ~37% ; ~5τ → settled .
Series |Z| = √[R² + (XL − XC)²].
f0 = 1/(2π√(LC)) ; series resonance Z → R .
XL rises with f; XC falls with f—opposites that can cancel.
Parallel tank at resonance → high impedance, not zero.
With Ohm’s Law networks, frequency/wavelength/waveform math, power and dB, and time-constant/impedance tools in place, you have completed Element 3 Topic 3-B electrical mathematics and are ready for passive and active component topics that apply these formulas on real parts.