Study guide

15.1 Batteries & Energy Storage

FCC General Radiotelephone Operator License GROL

Track your progress as you read

Finished sections get a check mark.

1 Introduction & GROL Exam Overview

1.1 About the General Radiotelephone Operator License 1.2 Exam Format, COLEMs, FRN & Application Process

2 Element 1: Rules & Regulations

2.1 Equipment Requirements (Part 80) 2.2 License Requirements & Operator Authority 2.3 Watchkeeping & Logkeeping Duties 2.4 Log Entries & Required Records 2.5 Ship Station Control, Inspections & International Rules

3 Element 1: Communications Procedures

3.1 Bridge-to-Bridge Operations & VTS 3.2 Distress Communications & Alerting 3.3 Operating Procedures, Calling & Testing 3.4 Urgency (PAN PAN) & Safety (SECURITE) Traffic 3.5 The GMDSS Concept & Ship Responsibilities

4 Element 1: Equipment Operations

4.1 VHF Equipment Controls 4.2 MF/HF SSB Equipment Controls 4.3 DSC Operations & Equipment Faults 4.4 VHF Channel Selection & Channel Assignments 4.5 MF/HF Frequency & Emission Selection 4.6 Required Equipment Tests & On-Air Test Procedure

5 Element 1: Other Equipment & Antennas

5.1 Marine Antennas & Polarization 5.2 EPIRBs & Emergency Beacons 5.3 Power Sources, Reserve Power & Required Tests 5.4 Search and Rescue Transponders (SARTs) 5.5 Survival Craft Portable VHF (SCT) Requirements 5.6 NAVTEX & Maritime Safety Information

6 Element 3: Electrical Principles

6.1 Electrical Elements, Units & Power Types 6.2 Magnetism & Magnetic Circuits 6.3 Resistance, Capacitance & Inductance 6.4 Waveforms & Semiconductor Introduction 6.5 Materials, Corrosion & Skin Effect 6.6 AC Measurement & Conversion Factors 6.7 Conduction, Reactive Power & Maximum Power Transfer

7 Element 3: Electrical Math

7.1 Ohm's Law — Series & Parallel Circuits 7.2 Frequency, Period, Wavelength & Waveform Math 7.3 Power Relationships & Decibels 7.4 RC/RL Time Constants 7.5 Frequency Counter Accuracy, PPM & Harmonics 7.6 Impedance in Rectangular & Polar Coordinates 7.7 Regulation, Turns Ratio, Zener Bias & Conductance

8 Element 3: Circuit Components — Passives & Power Devices

8.1 Capacitors & Photoconductive Devices 8.2 Transformers, Voltage Regulators & Zener Diodes 8.3 Diodes, SCRs & Triacs

9 Element 3: Active Components — Transistors & Devices

9.1 Bipolar Junction Transistors 9.2 FETs, LEDs & Specialty Devices 9.3 Device Selection, Ratings & Thermal Design

10 Element 3: Practical Circuits — RLC, Op Amps & Schematics

10.1 R-L-C Resonant Circuits 10.2 Op Amps, PLLs, VCOs & Mixers 10.3 Reading Schematics & Signal Flow

11 Element 3: Digital Logic

11.1 Logic Gates & Boolean Functions 11.2 Flip-Flops & Sequential Elements 11.3 Multivibrators & Timing Circuits 11.4 Microprocessors & Bus Architecture 11.5 TTL Logic Families & Input Voltage Levels 11.6 Positive & Negative Logic and Truth Tables 11.7 Memory Types & Microprocessor Concepts 11.8 Counters, Prescalers, BCD & Data Converters

12 Element 3: Receivers

12.1 Receiver Theory & Superheterodyne Architecture 12.2 RF Amplifiers & Front-End Design 12.3 Filters & Detectors 12.4 Audio, Squelch & Receiver Performance Specs 12.5 Receiver Oscillators: Colpitts, Hartley & Pierce 12.6 Mixing, Image Frequencies & Spurious Products 12.7 IF Selectivity & Filter Bandwidth

13 Element 3: Transmitters

13.1 RF Amplifier Classes & Efficiency 13.2 Oscillators, Modulators & Tuning Networks 13.3 SSB Transmitters & Modern Transmitter Technology

14 Element 3: Signals, Emissions & Modulation

14.1 Amplitude & Frequency Modulation 14.2 Single-Sideband Modulation 14.3 Pulse Modulation & Emission Types

15 Element 3: Power Sources

15.1 Batteries & Energy Storage 15.2 Motors, Generators & Power Supplies

16 Element 3: Antennas & Feed Lines

16.1 Antenna Theory, Types & Patterns 16.2 Voltage, Current & Impedance on Antennas 16.3 Transmission Lines, Velocity Factor & SWR 16.4 Effective Radiated Power & Antenna Bandwidth

17 Element 3 Background: Propagation & Radio Practice

17.1 Radio Wave Propagation Modes 17.2 Multipath, Fading & Doppler Effects 17.3 Radio Practice, Interference & Good Engineering

18 Element 3: Aircraft Radio Navigation Systems

18.1 DME & VOR 18.2 ILS, ADF & ATC Transponders 18.3 Aircraft Antennas, Frequencies & Equipment Functions

19 Element 3: Installation, Maintenance & Repair

19.1 Indicating Meters & Meter Movements 19.2 Oscilloscopes & Waveform Measurement 19.3 Measurement Procedures 19.4 Installation Codes & Bonding Procedures 19.5 Frequency Standards, SINAD Meters & EMI Hunting 19.6 Spectrum Analyzers, TDRs & Service Monitors 19.7 Bench Repair Practices, ESD & Rework Tools 19.8 Systematic Troubleshooting & Field Fault Diagnosis

20 Element 3: Communications Technology & Marine Systems

20.1 Transmission Types, Coding & Multiplexing 20.2 Signal Processing, Software & Codes 20.3 Marine VHF, MF/HF & SSB-SITOR 20.4 Survival Craft Electronics, FAX & NAVTEX 20.5 NMEA 0183 & NMEA 2000 Data Networks

21 Element 3: RADAR & Satellite Systems

21.1 RADAR Theory & Pulse Fundamentals 21.2 Range, Pulse Width & PRF 21.3 Radar Antennas & Waveguides 21.4 INMARSAT Satellite Communications 21.5 RADAR Components: Magnetron, Duplexer, ATR & Synchro 21.6 RADAR Equipment, ARPA & Radiation Safety 21.7 Low Earth Orbit Systems: Iridium & COSPAS-SARSAT 21.8 GPS Satellite Navigation & DGPS

22 Element 3: RF & Electrical Safety

22.1 RF Radiation Exposure Limits 22.2 Electrical Safety Practices for Radio Technicians

23 Study Strategy & Exam Day

23.1 Study Strategy, Practice Plan & Exam Day

15.1 Batteries & Energy Storage

Key Takeaways Explain This Topic AI

Primary cells are single-use chemical sources; secondary (storage) cells are rechargeable—lead-acid, NiCd, NiMH, and Li-ion dominate marine and aviation radio service

A fully charged lead-acid cell averages about 2.06 V; a NiCd cell operates near 1.25 V (twelve in series ≈ 15 V); capacity is rated in ampere-hours (Ah)

Battery runtime ≈ (Ah × V) / load watts; size reserve banks for continuous transmitter load (often 70% of key-locked demand) plus lighting or other DC loads

Charging flooded lead-acid cells emits hydrogen gas—ventilate; chronic undercharge causes sulfation; NiCd can show voltage depression (“memory”) after repeated shallow cycles

Series connection adds voltage at the same Ah; parallel connection adds Ah at the same voltage—match chemistry, capacity, and state of charge before paralleling

Last updated: August 2026

15.1 Batteries & Energy Storage

Quick Answer: Primary cells are disposable; secondary cells recharge. Lead-acid cell ≈ 2.06 V full; NiCd ≈ 1.25 V (12 series ≈ 15 V ). Capacity is ampere-hours (Ah) ; runtime ≈ (Ah × V) / watts . Charge flooded lead-acid → hydrogen gas. Undercharge → sulfation . Series adds volts ; parallel adds Ah . Size marine emergency banks for TX + RX continuous load over the required hours.

Topic 3-I (Power Sources) opens with batteries —the reserve energy that keeps radiotelephone, DSC, and radar alive when the ship’s generators or aircraft alternator are offline. Key topics 060 (Batteries-1) and 061 (Batteries-2) mix chemistry voltages with the arithmetic GROL techs use every time they size or prove a battery bank.

Primary vs secondary cells

Type Rechargeable? Typical radio use

Primary (e.g., zinc–carbon, alkaline, lithium primary) No (or not designed for routine recharge) Flashlights, some EPIRB/SART cells, handheld spares

Secondary / storage (lead-acid, NiCd, NiMH, Li-ion) Yes Ship reserve radio banks, aircraft main/standby, portable survival gear

Primary cells convert chemical energy once; you replace them. Secondary cells reverse the chemical reaction under controlled charge current. Element 3 emphasizes storage batteries because compulsory marine radio and most aviation installations depend on rechargeable banks tied to chargers and the ship/aircraft electrical system.

  • Cell voltages the pool expects
  • Lead-acid

Average fully-charged voltage of a lead-acid storage cell: about 2.06 V. A classic 12 V flooded or AGM battery is six cells in series (~12.3–12.7 V open-circuit when healthy and full). Nominal “12 V” labels hide that resting voltage and charge voltage are higher than the rough 2.0 V/cell under moderate load.

Nickel–cadmium

A nickel-cadmium cell has an operating voltage of about 1.25 V (pool also uses ~1.2 V for pack math). Twelve NiCd cells in series total about 15 V (12 × 1.25 ≈ 15 V). That is why older avionics and portable packs often appear as “15 V NiCd” strings rather than “12 V lead-acid” geometry.

Other common secondary chemistries (service literacy)

Chemistry Nominal cell V (approx.) Strengths Care notes

Lead-acid (flooded, gel, AGM) ~2.0–2.1 V Cheap Ah, high surge for TX peaks Vent hydrogen; avoid deep discharge / sulfation

NiCd ~1.25 V Robust cold performance, long cycle life Cadmium toxicity; voltage depression if always shallow-cycled

NiMH ~1.2 V Higher capacity than older NiCd, less toxic Self-discharge; heat on charge

Li-ion / LiFePO₄ ~3.6–3.7 / ~3.2 V High energy density, efficient Strict BMS charge limits; no free-venting gassing like flooded Pb

Element 3 exam items lock onto lead-acid 2.06 V and NiCd ~1.25 V / 15 V for 12 series . Treat NiMH and Li-ion as modern service knowledge that still obeys the same series/parallel and Ah rules.

Capacity, ampere-hours, and runtime

Ampere-hour (Ah) capacity is the product of discharge current and time the battery can sustain that current under a stated test (e.g., 20-hour rate). Idealized energy: Wh ≈ Ah × V nominal \text{Wh} \approx \text{Ah} \times V_{\text{nominal}} Wh ≈ Ah × V nominal ​ Runtime (hours) ≈ Ah × V P load (W) \text{Runtime (hours)} \approx \frac{\text{Ah} \times V}{P_{\text{load (W)}}} Runtime (hours) ≈ P load (W) ​ Ah × V ​

or equivalently (t = C / I) when you first convert load watts to amperes: (I = P / V).

Pool-style emergency radio examples

TX 325 W + RX 50 W = 375 W on a 12.6 V, 55 Ah battery: t = 55 × 12.6 375 ≈ 1.85 ≈ 1.8 h t = \frac{55 \times 12.6}{375} \approx 1.85 \approx \mathbf{1.8\ h} t = 375 55 × 12.6 ​ ≈ 1.85 ≈ 1.8 h

RADAR 315 W + radio 50 W = 365 W on 50 Ah @ 12.6 V : I = 365 / 12.6 ≈ 29.0 A , t = 50 / 29 ≈ 1.72 h ≈ 1 h 43 m i n I = 365 / 12.6 \approx 29.0\,\mathrm{A},\quad t = 50 / 29 \approx 1.72\,\mathrm{h} \approx \mathbf{1\ h\ 43\ min} I = 365/12.6 ≈ 29.0 A , t = 50/29 ≈ 1.72 h ≈ 1 h 43 min

RX 75 W + TX 325 W = 400 W on 50 Ah @ 12 V : I = 400 / 12 ≈ 33.3 A , t = 50 / 33.3 = 1.5 h I = 400 / 12 \approx 33.3\,\mathrm{A},\quad t = 50 / 33.3 = \mathbf{1.5\ h} I = 400/12 ≈ 33.3 A , t = 50/33.3 = 1.5 h

RX 50 W + RADAR 300 W = 350 W on 8 Ah @ 12.6 V : I = 350 / 12.6 ≈ 27.8 A , t ≈ 0.29 h ≈ 17 m i n ( 0.3 h ) I = 350 / 12.6 \approx 27.8\,\mathrm{A},\quad t \approx 0.29\,\mathrm{h} \approx \mathbf{17\ min\ (0.3\ h)} I = 350/12.6 ≈ 27.8 A , t ≈ 0.29 h ≈ 17 min ( 0.3 h )

These problems are pure (Ah × V) / W —memorize the pattern, not the story settings.

Sizing a bank for continuous TX load

Pool capacity problem: operate a transmitter for 6 hours with continuous load 70% of 40 A key-locked demand plus 1.5 A emergency lights: I = 0.7 × 40 + 1.5 = 29.5 A I = 0.7 \times 40 + 1.5 = 29.5\,\mathrm{A} I = 0.7 × 40 + 1.5 = 29.5 A C = 29.5 × 6 = 177 A h C = 29.5 \times 6 = \mathbf{177\ Ah} C = 29.5 × 6 = 177 Ah

Always include duty-factor (key-locked vs continuous) and parasitic DC loads when specifying marine reserve capacity.

Series and parallel connections

  • Connection Voltage Capacity (Ah) Current capability
  • Series Sum of cell voltages Same as one cell (weakest) Same as one string
  • Parallel Same as one cell Sum of Ah ratings Higher total current
  • Series–parallel packs Sum in strings Sum across parallel strings Design for equal string currents

Series is how six lead-acid cells make 12 V and how twelve NiCd cells make ~15 V. Parallel multiplies Ah for longer runtime at the same system voltage. Never parallel dissimilar chemistries, mixed ages, or cells at different state of charge without isolation/BMS—circulating currents and thermal abuse follow.

  • Charge rates, trickle charge, and internal resistance
  • Resistor trickle charge from a DC bus

To trickle-charge a 12.5 V battery at 0.5 A from a 110 V DC line, put a series resistor that drops the excess voltage: R = 110 − 12.5 0.5 = 195 Ω R = \frac{110 - 12.5}{0.5} = \mathbf{195\ \Omega} R = 0.5 110 − 12.5 ​ = 195 Ω

Modern marine systems use regulated chargers; the exam still tests this (V_source − V_batt) / I_charge relationship.

Charge / discharge rates (C-rate language)

A 1C rate discharges the full Ah rating in one hour (a 50 Ah battery at 50 A). C/10 is a gentle 10-hour rate often used for bulk charge of flooded lead-acid. High discharge rates reduce effective Ah (Peukert effect on lead-acid). Radio TX peaks are short but high-amp—banks and cable gauge must support peak current without huge voltage sag.

Internal resistance load math

Batteries are ideal voltage sources in series with internal resistance r i n t r_{int} r in t ​ . Example: 6 V battery, r i n t = 0.01 Ω r_{int} = 0.01\ \Omega r in t ​ = 0.01 Ω , 3 W / 6 V lamp: R l a m p = V 2 / P = 36 / 3 = 12 Ω R_{lamp} = V^2 / P = 36 / 3 = 12\ \Omega R l am p ​ = V 2 / P = 36/3 = 12 Ω I = 6 / ( 12 + 0.01 ) = 0.4995 A I = 6 / (12 + 0.01) = \mathbf{0.4995\ A} I = 6/ ( 12 + 0.01 ) = 0.4995 A

Two 12 Ω lamps in parallel (6 Ω) on a 6 V battery with 1.2 Ω internal: I = 6 / ( 6 + 1.2 ) = 6 / 7.2 = 0.83 A I = 6 / (6 + 1.2) = 6 / 7.2 = \mathbf{0.83\ A} I = 6/ ( 6 + 1.2 ) = 6/7.2 = 0.83 A

Voltage sag under load is I × r i n t I \times r_{int} I × r in t ​ —old, cold, or sulfated banks show larger sag and shorter real runtime than the nameplate Ah suggests.

  • Lead-acid care, hydrogen, and sulfation
  • Hydrogen on charge

When a lead-acid storage battery is being charged, a harmful effect to humans is emission of hydrogen gas. Overcharge electrolyzes water; hydrogen + oxygen is an explosion hazard. Charge in ventilated spaces, keep sparks/flames away from cell tops, and follow vessel/aircraft ventilation rules. Do not confuse this with “sulfation under constant charging” as the human hazard answer—the pool’s human hazard is hydrogen .

Sulfation

Sulfation is hard lead-sulfate crystal growth on plates after prolonged partial state of charge or deep discharge without full recharge. Capacity falls, internal resistance rises, and chargers may never finish absorption. Prevention: keep float/charge systems healthy, avoid long idle discharge, and equalize flooded cells only per manufacturer procedure.

Marine / aviation care checklist

Secure batteries against vibration; inspect hold-downs and terminal corrosion.

Maintain electrolyte (flooded) and use correct temperature-compensated charge voltages.

Prove capacity periodically (load test / Ah discharge)—Element 1 reserve-power rules expect scheduled condition checks.

Size cables for TX peak current; fuse at the battery.

Isolate chemistry: never charge Li-ion on a flooded lead-acid profile or vice versa.

Memory effect and NiCd notes

Classic NiCd “memory effect” (voltage depression) appears when cells are repeatedly recharged after only shallow discharge at the same depth—the cell appears to “remember” a lower capacity. Full discharge/recondition cycles (where the equipment manufacturer allows) and modern smart chargers mitigate it. NiMH is less memory-prone but still hates chronic overheat. Li-ion does not use NiCd-style memory; its failure modes are over-voltage, over-current, and thermal runaway without a proper BMS .

Exam-day battery checklist (3-I 060–061)

Lead-acid full cell ≈ 2.06 V ; NiCd ≈ 1.25 V ; 12 NiCd series ≈ 15 V .

Runtime ≈ (Ah × V) / W ; convert minutes carefully (0.3 h ≈ 18 min → pool “17 min”).

Capacity size: (0.7 × key-locked A + accessory A) × hours → e.g. 177 Ah .

Trickle resistor: (V_line − V_batt) / I → 195 Ω example.

Charge hazard: hydrogen gas; chronic abuse: sulfation ; NiCd shallow cycles: memory/voltage depression .

Series → volts add; parallel → Ah add; include r_int in load current math.

Master Ah math and the two classic cell voltages and the 060–061 items become mechanical. Next section covers motors, generators, and regulated power supplies that charge and support these banks.