Study guide
6.3 Flow Measurement and Fluid Machinery
NCEES Fundamentals of Engineering FE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Mathematics
1.1 Analytic Geometry, Algebra, and Trigonometry 1.2 Calculus and Differential Equations 1.3 Numerical Methods and Measurement Error
2 Chapter 2: Probability and Statistics
2.1 Probability Distributions, Central Tendency, and Regression 2.2 Hypothesis Testing, ANOVA, and Statistical Quality Control
3 Chapter 3: Engineering Sciences
3.1 Mechanics and Dynamics 3.2 Electrical Circuits and Laws
4 Chapter 4: Materials Science
4.1 Material Properties and Compatibilities 4.2 Corrosion, Polymers, Ceramics, and Composites
5 Chapter 5: Chemistry and Biology
5.1 Stoichiometry, Analytical Chemistry, and Chemical Equilibrium 5.2 Organic Chemistry and Nomenclature 5.3 Biological Systems and Kinetics
6 Chapter 6: Fluid Mechanics and Dynamics
6.1 Fluid Properties, Dimensionless Numbers, and Flow Regimes 6.2 Bernoulli Equation and Mechanical Energy Balances 6.3 Flow Measurement and Fluid Machinery 6.4 Compressible and Non-Newtonian Flows
7 Chapter 7: Thermodynamics
7.1 Thermodynamic Properties, Ideal Gas, and State Equations 7.2 Laws of Thermodynamics and Cyclic Processes 7.3 Vapor-Liquid Equilibrium (VLE) and Phase Equilibrium 7.4 Chemical Equilibrium, Heats of Reaction, and Mixing
8 Chapter 8: Material and Energy Balances
8.1 Steady-State Material Balances 8.2 Unsteady-State Mass Balances 8.3 Steady-State Energy Balances 8.4 Unsteady-State Energy Balances
9 Chapter 9: Heat Transfer
9.1 Conduction, Convection, and Radiation Fundamentals 9.2 Heat Transfer Coefficients, Fouling, and Overall U 9.3 Heat Exchanger Design
10 Chapter 10: Mass Transfer and Separation
10.1 Diffusion Fundamentals 10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction 10.3 Distillation and McCabe-Thiele Method 10.4 Continuous Contact Methods, Membrane Separations, and Evaporative Operations
11 Chapter 11: Solids Handling
11.1 Particle Properties and Solid Processing 11.2 Solids Transportation and Storage
12 Chapter 12: Chemical Reaction Engineering
12.1 Reaction Kinetics and Performance Metrics 12.2 Ideal Reactor Design 12.3 Multiple Reactions, Catalysis, and Heterogeneous Kinetics
13 Chapter 13: Economics
13.1 Time Value of Money and Project Selection 13.2 Profitability Analysis, Depreciation, and Break-Even
14 Chapter 14: Process Design
14.1 Process Flowsheets and Instrumentation 14.2 Equipment Selection, Sizing, and Cost Estimation 14.3 Process Optimization, Sustainability, and Inherently Safer Design
15 Chapter 15: Process Control
15.1 Process Dynamics and Transfer Functions 15.2 Feedback Control Loops, PID Tuning, and Control Hardware
16 Chapter 16: Safety, Health, and Environment
16.1 Flammability, Toxicity, and Industrial Hygiene 16.2 Hazard Identification and Risk Analysis 16.3 Overpressure Relief, Reactivity Hazards, and Waste Regulations
17 Chapter 17: Ethics and Professional Practice
17.1 Professional Codes of Ethics and Public Welfare 17.2 Intellectual Property, Contracts, and Professional Liability
6.3 Flow Measurement and Fluid Machinery
Key Takeaways Explain This Topic AI
Orifice and Venturi meters are obstruction-type meters that relate flow rate to differential pressure.
Venturi meters feature low unrecoverable pressure loss and high discharge coefficients (Cd ≈ 0.98), whereas orifice meters have high loss and low coefficients (Cd ≈ 0.61).
A rotameter is a variable-area flow meter where the float height equilibrium represents drag, buoyancy, and gravity balance.
Centrifugal pump operating points are found at the intersection of the pump performance curve and the system curve.
Cavitation occurs when local pressure falls below vapor pressure; it is prevented by ensuring NPSHA exceeds NPSHR.
Last updated: July 2026
Flow Measurement Devices: Orifice, Venturi, and Rotameters
Accurate flow rate measurement is essential for process control and mass balance verification. The three most common flow meters in chemical processes are orifice meters, Venturi meters, and rotameters.
Orifice and Venturi Meters: Both are obstruction-type meters that create a local constriction in the flow channel. According to the Bernoulli and continuity equations, restricting the flow increases fluid velocity, which results in a localized pressure drop. The volumetric flow rate ( q q q ) is calculated using the standard flow meter formula: q = C d A 2 2 ( P 1 − P 2 ) ρ ( 1 − β 4 ) q = C_d A_2 \sqrt{\frac{2(P_1 - P_2)}{\rho (1 - \beta^4)}} q = C d A 2 ρ ( 1 − β 4 ) 2 ( P 1 − P 2 )
where:
C d C_d C d is the dimensionless discharge coefficient.
A 2 A_2 A 2 is the cross-sectional area of the throat or orifice opening.
P 1 − P 2 P_1 - P_2 P 1 − P 2 is the differential pressure measured across the meter.
ρ \rho ρ is the fluid density.
β = D 2 / D 1 \beta = D_2 / D_1 β = D 2 / D 1 is the ratio of throat/orifice diameter to the pipe diameter. The term 1 1 − β 4 \frac{1}{\sqrt{1 - \beta^4}} 1 − β 4 1 is known as the velocity of approach factor.
The primary difference between the two meters lies in their geometry, which dictates their performance:
Orifice Meter: Consists of a thin plate with a sharp-edged hole. It is inexpensive, simple to install, and occupies little space, but it creates high unrecoverable pressure loss due to intense eddy formation downstream. Its discharge coefficient C d C_d C d typically ranges from 0.60 0.60 0.60 to 0.62 0.62 0.62 because the fluid jet contracts to a minimum area (the vena contracta) that is smaller than the physical orifice opening.
Venturi Meter: Consists of a converging section, a throat, and a diverging recovery cone. It is streamlined to minimize flow separation, resulting in excellent pressure recovery (low unrecoverable loss). However, it is expensive, bulky, and difficult to manufacture. Its discharge coefficient C d C_d C d is much higher, typically between 0.97 0.97 0.97 and 0.99 0.99 0.99 .
Rotameter: A rotameter is a variable-area meter. It consists of a vertical, tapered glass tube containing a float. As fluid flows upward, the float rises until the upward drag force and buoyancy force equal the downward gravitational force: F drag + F buoyancy = F gravity F_{\text{drag}} + F_{\text{buoyancy}} = F_{\text{gravity}} F drag + F buoyancy = F gravity
The equilibrium height of the float is directly proportional to the volumetric flow rate, read from a calibrated scale on the tube.
Pump Performance, Operating Point, and Affinity Laws
Pumps transfer mechanical energy to liquids to increase pressure or elevation. Centrifugal pumps are the workhorses of chemical plants.
The Operating Point: A centrifugal pump operates at the intersection of the pump performance curve (head vs. flow rate, provided by the manufacturer) and the system curve (required head vs. flow rate, determined by elevation change and pipe friction): h pump ( Q ) = h system ( Q ) = Δ z + Δ P ρ g + ( ∑ f D L D H + ∑ K L ) Q 2 2 g A c 2 h_{\text{pump}}(Q) = h_{\text{system}}(Q) = \Delta z + \frac{\Delta P}{\rho g} + \left( \sum f_D \frac{L}{D_H} + \sum K_L \right) \frac{Q^2}{2g A_c^2} h pump ( Q ) = h system ( Q ) = Δ z + ρ g Δ P + ( ∑ f D D H L + ∑ K L ) 2 g A c 2 Q 2
Changing a valve setting alters the system curve, moving the operating point.
Pump Affinity Laws: For geometrically similar (homologous) pumps, performance changes with shaft speed ( N N N , rpm) and impeller diameter ( D D D ) according to the affinity laws. When impeller diameter is held constant ( D 1 = D 2 D_1 = D_2 D 1 = D 2 ):
- Flow Rate: Q 2 / Q 1 = N 2 / N 1 Q_2 / Q_1 = N_2 / N_1 Q 2 / Q 1 = N 2 / N 1
- Head: H 2 / H 1 = ( N 2 / N 1 ) 2 H_2 / H_1 = (N_2 / N_1)^2 H 2 / H 1 = ( N 2 / N 1 ) 2
- Power: P 2 / P 1 = ( N 2 / N 1 ) 3 P_2 / P_1 = (N_2 / N_1)^3 P 2 / P 1 = ( N 2 / N 1 ) 3
- Cavitation and Net Positive Suction Head (NPSH)
Cavitation is a destructive phenomenon that occurs when the local static pressure inside a pump drops below the liquid's vapor pressure ( P v p P_{vp} P v p ). This causes the liquid to flash into vapor bubbles. As these bubbles move into higher-pressure regions near the impeller, they collapse violently, generating high-velocity micro-jets and shockwaves that pit metal surfaces, cause severe vibration, and reduce pump efficiency.
To prevent cavitation, the Net Positive Suction Head Available ( N P S H A NPSH_A NPS H A ) at the pump suction nozzle must exceed the Net Positive Suction Head Required ( N P S H R NPSH_R NPS H R ) specified by the pump manufacturer: N P S H A > N P S H R NPSH_A > NPSH_R NPS H A > NPS H R
N P S H A NPSH_A NPS H A represents the total head at the pump suction nozzle above the vapor pressure head: N P S H A = P s ρ g + v s 2 2 g − P v p ρ g NPSH_A = \frac{P_s}{\rho g} + \frac{v_s^2}{2g} - \frac{P_{vp}}{\rho g} NPS H A = ρ g P s + 2 g v s 2 − ρ g P v p
In terms of a source reservoir open to the atmosphere: N P S H A = H atm ± z s − h f , suction − H vp NPSH_A = H_{\text{atm}} \pm z_s - h_{f,\text{suction}} - H_{\text{vp}} NPS H A = H atm ± z s − h f , suction − H vp
where H atm = P atm / ρ g H_{\text{atm}} = P_{\text{atm}} / \rho g H atm = P atm / ρ g , z s z_s z s is the elevation of the suction liquid level relative to the pump inlet (positive if liquid level is above the pump, negative if below), h f , suction h_{f,\text{suction}} h f , suction is the frictional head loss in the suction piping, and H vp = P v p / ρ g H_{\text{vp}} = P_{vp} / \rho g H vp = P v p / ρ g .
Compressors, Turbines, and Vacuum Systems
Compressors and Turbines: Compressors add energy to gases (increasing pressure), while turbines extract energy from expanding fluids to perform shaft work. For gas compressors and turbines, thermodynamic paths (isentropic vs. polytropic) are analyzed. The isentropic efficiency ( η \eta η ) relates actual work to ideal work: η compressor = w isentropic w actual and η turbine = w actual w isentropic \eta_{\text{compressor}} = \frac{w_{\text{isentropic}}}{w_{\text{actual}}} \quad \text{and} \quad \eta_{\text{turbine}} = \frac{w_{\text{actual}}}{w_{\text{isentropic}}} η compressor = w actual w isentropic and η turbine = w isentropic w actual
Vacuum Systems: Steam-jet ejectors and liquid-ring vacuum pumps are used to maintain sub-atmospheric pressures in process vessels (e.g., vacuum distillation columns). Ejectors utilize high-velocity steam jets through a Venturi nozzle to entrain process gases, converting kinetic energy into pressure rise.
Worked Example 1: Venturi Meter Flow Rate
Problem: A Venturi meter with a throat diameter of 5.0 cm 5.0\text{ cm} 5.0 cm is installed in a 10.0 cm 10.0\text{ cm} 10.0 cm diameter pipe carrying water ( ρ = 1000 kg/m 3 \rho = 1000\text{ kg/m}^3 ρ = 1000 kg/m 3 ). A differential pressure transducer reads 40 kPa 40\text{ kPa} 40 kPa across the meter. Assuming a discharge coefficient C d = 0.98 C_d = 0.98 C d = 0.98 , calculate the volumetric flow rate.
Solution:
Calculate the diameter ratio ( β \beta β ) and throat area ( A 2 A_2 A 2 ): β = D 2 D 1 = 5.0 cm 10.0 cm = 0.50 \beta = \frac{D_2}{D_1} = \frac{5.0\text{ cm}}{10.0\text{ cm}} = 0.50 β = D 1 D 2 = 10.0 cm 5.0 cm = 0.50 A 2 = π 4 D 2 2 = π 4 ( 0.05 m ) 2 ≈ 1.963 × 10 − 3 m 2 A_2 = \frac{\pi}{4} D_2^2 = \frac{\pi}{4} (0.05\text{ m})^2 \approx 1.963 \times 10^{-3}\text{ m}^2 A 2 = 4 π D 2 2 = 4 π ( 0.05 m ) 2 ≈ 1.963 × 1 0 − 3 m 2
Substitute the values into the flow meter formula: q = C d A 2 2 Δ P ρ ( 1 − β 4 ) = 0.98 ⋅ ( 1.963 × 10 − 3 ) ⋅ 2 ⋅ 40 , 000 Pa 1000 kg/m 3 ⋅ ( 1 − 0.5 4 ) q = C_d A_2 \sqrt{\frac{2 \Delta P}{\rho (1 - \beta^4)}} = 0.98 \cdot (1.963 \times 10^{-3}) \cdot \sqrt{\frac{2 \cdot 40,000\text{ Pa}}{1000\text{ kg/m}^3 \cdot (1 - 0.5^4)}} q = C d A 2 ρ ( 1 − β 4 ) 2Δ P = 0.98 ⋅ ( 1.963 × 1 0 − 3 ) ⋅ 1000 kg/m 3 ⋅ ( 1 − 0. 5 4 ) 2 ⋅ 40 , 000 Pa q = 1.924 × 10 − 3 ⋅ 80 , 000 1000 ⋅ ( 1 − 0.0625 ) = 1.924 × 10 − 3 ⋅ 80 , 000 937.5 q = 1.924 \times 10^{-3} \cdot \sqrt{\frac{80,000}{1000 \cdot (1 - 0.0625)}} = 1.924 \times 10^{-3} \cdot \sqrt{\frac{80,000}{937.5}} q = 1.924 × 1 0 − 3 ⋅ 1000 ⋅ ( 1 − 0.0625 ) 80 , 000 = 1.924 × 1 0 − 3 ⋅ 937.5 80 , 000 q = 1.924 × 10 − 3 ⋅ 85.33 ≈ 1.924 × 10 − 3 ⋅ 9.238 ≈ 0.0178 m 3 /s = 17.8 L/s q = 1.924 \times 10^{-3} \cdot \sqrt{85.33} \approx 1.924 \times 10^{-3} \cdot 9.238 \approx 0.0178\text{ m}^3\text{/s} = 17.8\text{ L/s} q = 1.924 × 1 0 − 3 ⋅ 85.33 ≈ 1.924 × 1 0 − 3 ⋅ 9.238 ≈ 0.0178 m 3 /s = 17.8 L/s
Worked Example 2: NPSHA and Cavitation Verification
Problem: A centrifugal pump draws water at 50 ∘ C 50^\circ\text{C} 5 0 ∘ C ( ρ = 988 kg/m 3 \rho = 988\text{ kg/m}^3 ρ = 988 kg/m 3 , vapor pressure P v p = 12.35 kPa P_{vp} = 12.35\text{ kPa} P v p = 12.35 kPa ) from an open tank. The water level in the tank is 3.0 m 3.0\text{ m} 3.0 m below the centerline of the pump inlet. The suction line has a total frictional head loss of 1.2 m 1.2\text{ m} 1.2 m . If the atmospheric pressure is 101.3 kPa 101.3\text{ kPa} 101.3 kPa , calculate N P S H A NPSH_A NPS H A . If the pump requires N P S H R = 4.5 m NPSH_R = 4.5\text{ m} NPS H R = 4.5 m , will the pump cavitate?
Solution:
Convert pressures to head: H atm = P atm ρ g = 101 , 300 Pa 988 kg/m 3 ⋅ 9.807 m/s 2 = 101 , 300 9689.3 ≈ 10.45 m H_{\text{atm}} = \frac{P_{\text{atm}}}{\rho g} = \frac{101,300\text{ Pa}}{988\text{ kg/m}^3 \cdot 9.807\text{ m/s}^2} = \frac{101,300}{9689.3} \approx 10.45\text{ m} H atm = ρ g P atm = 988 kg/m 3 ⋅ 9.807 m/s 2 101 , 300 Pa = 9689.3 101 , 300 ≈ 10.45 m H vp = P vp ρ g = 12 , 350 Pa 988 kg/m 3 ⋅ 9.807 m/s 2 = 12 , 350 9689.3 ≈ 1.27 m H_{\text{vp}} = \frac{P_{\text{vp}}}{\rho g} = \frac{12,350\text{ Pa}}{988\text{ kg/m}^3 \cdot 9.807\text{ m/s}^2} = \frac{12,350}{9689.3} \approx 1.27\text{ m} H vp = ρ g P vp = 988 kg/m 3 ⋅ 9.807 m/s 2 12 , 350 Pa = 9689.3 12 , 350 ≈ 1.27 m
Since the water level is below the pump, z s = − 3.0 m z_s = -3.0\text{ m} z s = − 3.0 m (suction lift).
Calculate N P S H A NPSH_A NPS H A : N P S H A = H atm + z s − h f , suction − H vp = 10.45 m − 3.0 m − 1.2 m − 1.27 m = 4.98 m NPSH_A = H_{\text{atm}} + z_s - h_{f,\text{suction}} - H_{\text{vp}} = 10.45\text{ m} - 3.0\text{ m} - 1.2\text{ m} - 1.27\text{ m} = 4.98\text{ m} NPS H A = H atm + z s − h f , suction − H vp = 10.45 m − 3.0 m − 1.2 m − 1.27 m = 4.98 m
Compare N P S H A NPSH_A NPS H A with N P S H R NPSH_R NPS H R : N P S H A = 4.98 m > N P S H R = 4.5 m NPSH_A = 4.98\text{ m} > NPSH_R = 4.5\text{ m} NPS H A = 4.98 m > NPS H R = 4.5 m
The available head exceeds the required head, so the pump will not cavitate.