Study guide
9.3 Heat Exchanger Design
NCEES Fundamentals of Engineering FE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Mathematics
1.1 Analytic Geometry, Algebra, and Trigonometry 1.2 Calculus and Differential Equations 1.3 Numerical Methods and Measurement Error
2 Chapter 2: Probability and Statistics
2.1 Probability Distributions, Central Tendency, and Regression 2.2 Hypothesis Testing, ANOVA, and Statistical Quality Control
3 Chapter 3: Engineering Sciences
3.1 Mechanics and Dynamics 3.2 Electrical Circuits and Laws
4 Chapter 4: Materials Science
4.1 Material Properties and Compatibilities 4.2 Corrosion, Polymers, Ceramics, and Composites
5 Chapter 5: Chemistry and Biology
5.1 Stoichiometry, Analytical Chemistry, and Chemical Equilibrium 5.2 Organic Chemistry and Nomenclature 5.3 Biological Systems and Kinetics
6 Chapter 6: Fluid Mechanics and Dynamics
6.1 Fluid Properties, Dimensionless Numbers, and Flow Regimes 6.2 Bernoulli Equation and Mechanical Energy Balances 6.3 Flow Measurement and Fluid Machinery 6.4 Compressible and Non-Newtonian Flows
7 Chapter 7: Thermodynamics
7.1 Thermodynamic Properties, Ideal Gas, and State Equations 7.2 Laws of Thermodynamics and Cyclic Processes 7.3 Vapor-Liquid Equilibrium (VLE) and Phase Equilibrium 7.4 Chemical Equilibrium, Heats of Reaction, and Mixing
8 Chapter 8: Material and Energy Balances
8.1 Steady-State Material Balances 8.2 Unsteady-State Mass Balances 8.3 Steady-State Energy Balances 8.4 Unsteady-State Energy Balances
9 Chapter 9: Heat Transfer
9.1 Conduction, Convection, and Radiation Fundamentals 9.2 Heat Transfer Coefficients, Fouling, and Overall U 9.3 Heat Exchanger Design
10 Chapter 10: Mass Transfer and Separation
10.1 Diffusion Fundamentals 10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction 10.3 Distillation and McCabe-Thiele Method 10.4 Continuous Contact Methods, Membrane Separations, and Evaporative Operations
11 Chapter 11: Solids Handling
11.1 Particle Properties and Solid Processing 11.2 Solids Transportation and Storage
12 Chapter 12: Chemical Reaction Engineering
12.1 Reaction Kinetics and Performance Metrics 12.2 Ideal Reactor Design 12.3 Multiple Reactions, Catalysis, and Heterogeneous Kinetics
13 Chapter 13: Economics
13.1 Time Value of Money and Project Selection 13.2 Profitability Analysis, Depreciation, and Break-Even
14 Chapter 14: Process Design
14.1 Process Flowsheets and Instrumentation 14.2 Equipment Selection, Sizing, and Cost Estimation 14.3 Process Optimization, Sustainability, and Inherently Safer Design
15 Chapter 15: Process Control
15.1 Process Dynamics and Transfer Functions 15.2 Feedback Control Loops, PID Tuning, and Control Hardware
16 Chapter 16: Safety, Health, and Environment
16.1 Flammability, Toxicity, and Industrial Hygiene 16.2 Hazard Identification and Risk Analysis 16.3 Overpressure Relief, Reactivity Hazards, and Waste Regulations
17 Chapter 17: Ethics and Professional Practice
17.1 Professional Codes of Ethics and Public Welfare 17.2 Intellectual Property, Contracts, and Professional Liability
9.3 Heat Exchanger Design
Key Takeaways Explain This Topic AI
Counter-current flow is thermodynamically superior to parallel flow because it maintains a larger, more uniform driving temperature difference and avoids temperature cross limits
The Log Mean Temperature Difference (LMTD) method is used for sizing exchangers when all inlet and outlet temperatures are known
Multipass exchangers require a correction factor F (F <= 1.0) applied to the counter-current LMTD: Q = U A F LMTD_CF
The Effectiveness-NTU (epsilon-NTU) method is preferred for rating exchangers when outlet temperatures are unknown, avoiding iterative calculations
Last updated: July 2026
9.3 Heat Exchanger Design
Heat exchangers are devices that facilitate the transfer of thermal energy between two or more fluids at different temperatures. They are ubiquitous in chemical processes, ranging from simple double-pipe heat exchangers to complex shell-and-tube units. When designing or rating heat exchangers, chemical engineers rely on two key methods: the Log Mean Temperature Difference (LMTD) method and the Effectiveness-Number of Transfer Units ( ϵ {\epsilon} ϵ -NTU) method. This section covers double-pipe and shell-and-tube configurations, co-current vs. counter-current flows, and the applications of both methods using formulas consistent with the FE Reference Handbook.
Heat Exchanger Configurations
Heat exchangers are classified based on their construction and flow configuration.
Double-Pipe Heat Exchangers
The simplest design consists of two concentric pipes. One fluid flows through the inner pipe while the other flows through the annular space.
Parallel Flow (Co-current) : Both fluids enter at the same end, flow in the same direction, and leave at the same end. The outlet temperature of the cold fluid can never exceed the outlet temperature of the hot fluid.
Counter-Current Flow : The fluids enter at opposite ends and flow in opposite directions. This maintains a more uniform temperature difference along the exchanger length. The cold fluid outlet temperature can exceed the hot fluid outlet temperature, resulting in higher thermodynamic efficiency and lower thermodynamic irreversibility (entropy generation).
Shell-and-Tube Heat Exchangers
For larger thermal loads, shell-and-tube exchangers are used. These consist of a bundle of tubes mounted inside a cylindrical shell. Baffles are installed in the shell to support the tubes, direct the shell-side fluid flow across the tube bundle to increase turbulence, and enhance the convective heat transfer coefficient.
Pass Configurations : Described by the number of shell passes and tube passes. A "1-2 exchanger" has one shell pass and two tube passes. Multipass designs increase the fluid velocity and heat transfer rate, though they increase pressure drop.
Log Mean Temperature Difference (LMTD) Method
The heat transfer rate in a heat exchanger is expressed as: Q ˙ = U A Δ T l m \dot{Q} = U A \Delta T_{lm} Q ˙ = U A Δ T l m
where U U U is the overall heat transfer coefficient, A A A is the heat transfer area, and Δ T l m \Delta T_{lm} Δ T l m is the Log Mean Temperature Difference (LMTD).
The LMTD is defined as: Δ T l m = Δ T 1 − Δ T 2 ln ( Δ T 1 / Δ T 2 ) \Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} Δ T l m = ln ( Δ T 1 /Δ T 2 ) Δ T 1 − Δ T 2
The definition of the terminal temperature differences Δ T 1 \Delta T_1 Δ T 1 and Δ T 2 \Delta T_2 Δ T 2 depends on the flow direction:
Flow Type Δ T 1 \Delta T_1 Δ T 1 Δ T 2 \Delta T_2 Δ T 2
Parallel (Co-current) T h , i n − T c , i n T_{h,in} - T_{c,in} T h , in − T c , in T h , o u t − T c , o u t T_{h,out} - T_{c,out} T h , o u t − T c , o u t
Counter-Current T h , i n − T c , o u t T_{h,in} - T_{c,out} T h , in − T c , o u t T h , o u t − T c , i n T_{h,out} - T_{c,in} T h , o u t − T c , in
If the temperature differences at the two ends are equal ( Δ T 1 = Δ T 2 \Delta T_1 = \Delta T_2 Δ T 1 = Δ T 2 ), the expression for LMTD is mathematically indeterminate ( 0 / 0 0/0 0/0 ). LMTD is then evaluated as the limit, which simplifies to Δ T l m = Δ T 1 = Δ T 2 \Delta T_{lm} = \Delta T_1 = \Delta T_2 Δ T l m = Δ T 1 = Δ T 2 .
LMTD Correction Factor (F)
For multipass shell-and-tube and cross-flow heat exchangers, the flow is not purely counter-current. To account for this, a dimensionless correction factor ( F F F ) is introduced: Q ˙ = U A F Δ T l m , C F \dot{Q} = U A F \Delta T_{lm,CF} Q ˙ = U A F Δ T l m , CF
where Δ T l m , C F \Delta T_{lm,CF} Δ T l m , CF is the LMTD calculated assuming pure counter-current flow.
F F F is always less than or equal to 1.0 1.0 1.0 ( F = 1.0 F = 1.0 F = 1.0 for pure counter-current flow).
F F F is determined using charts in the FE Reference Handbook based on two dimensionless ratios:
Temperature Effectiveness ( P P P ) : P = t o u t − t i n T i n − t i n P = \frac{t_{out} - t_{in}}{T_{in} - t_{in}} P = T in − t in t o u t − t in
Capacity Ratio ( R R R ) : R = T i n − T o u t t o u t − t i n R = \frac{T_{in} - T_{out}}{t_{out} - t_{in}} R = t o u t − t in T in − T o u t (Here, uppercase T T T represents the shell-side fluid and lowercase t t t represents the tube-side fluid).
If F < 0.75 F < 0.75 F < 0.75 , the design is generally inefficient due to potential temperature cross, and a multi-shell-pass design should be selected.
Effectiveness-NTU (ε-NTU) Method
When the fluid outlet temperatures are unknown, the LMTD method requires iterative calculations. In such cases, the Effectiveness-NTU ( ϵ \epsilon ϵ -NTU) method is preferred.
Key Parameters
Heat Capacity Rate ( C C C ) : C = m ˙ C p C = \dot{m} C_p C = m ˙ C p Identify C m i n = min ( C h , C c ) C_{min} = \min(C_h, C_c) C min = min ( C h , C c ) and C m a x = max ( C h , C c ) C_{max} = \max(C_h, C_c) C ma x = max ( C h , C c ) .
Maximum Possible Heat Transfer Rate ( Q ˙ m a x \dot{Q}_{max} Q ˙ ma x ) : Q ˙ m a x = C m i n ( T h , i n − T c , i n ) \dot{Q}_{max} = C_{min} (T_{h,in} - T_{c,in}) Q ˙ ma x = C min ( T h , in − T c , in ) This represents the heat transfer in an infinitely long counter-current exchanger.
Heat Exchanger Effectiveness ( ϵ {\epsilon} ϵ ) : ϵ = Q ˙ Q ˙ m a x \epsilon = \frac{\dot{Q}}{\dot{Q}_{max}} ϵ = Q ˙ ma x Q ˙ The actual heat transfer rate is then: Q ˙ = ϵ C m i n ( T h , i n − T c , i n ) \dot{Q} = \epsilon C_{min} (T_{h,in} - T_{c,in}) Q ˙ = ϵ C min ( T h , in − T c , in )
Number of Transfer Units ( N T U NTU NT U ) : N T U = U A C m i n NTU = \frac{U A}{C_{min}} NT U = C min U A
Capacity Ratio ( C r C_r C r ) : C r = C m i n C m a x ( 0 ≤ C r ≤ 1 ) C_r = \frac{C_{min}}{C_{max}} \qquad (0 \le C_r \le 1) C r = C ma x C min ( 0 ≤ C r ≤ 1 )
Effectiveness Relations
The effectiveness is a function of NTU and C r C_r C r depending on flow configuration:
Parallel Flow : ϵ = 1 − exp [ − N T U ( 1 + C r ) ] 1 + C r \epsilon = \frac{1 - \exp[-NTU(1 + C_r)]}{1 + C_r} ϵ = 1 + C r 1 − exp [ − NT U ( 1 + C r )]
Counter-Current Flow : ϵ = 1 − exp [ − N T U ( 1 − C r ) ] 1 − C r exp [ − N T U ( 1 − C r ) ] ( for C r < 1 ) \epsilon = \frac{1 - \exp[-NTU(1 - C_r)]}{1 - C_r \exp[-NTU(1 - C_r)]} \qquad (\text{for } C_r < 1) ϵ = 1 − C r exp [ − NT U ( 1 − C r )] 1 − exp [ − NT U ( 1 − C r )] ( for C r < 1 ) ϵ = N T U 1 + N T U ( for C r = 1 ) \epsilon = \frac{NTU}{1 + NTU} \qquad (\text{for } C_r = 1) ϵ = 1 + NT U NT U ( for C r = 1 )
Condensers/Boilers ( C r = 0 C_r = 0 C r = 0 ) :
When one fluid undergoes a phase change (e.g., steam condensing or refrigerant boiling), its specific heat is effectively infinite, meaning C m a x → ∞ C_{max} \to \infty C ma x → ∞ and C r = 0 C_r = 0 C r = 0 . For all flow configurations: ϵ = 1 − exp ( − N T U ) \epsilon = 1 - \exp(-NTU) ϵ = 1 − exp ( − NT U )
- Worked Examples
- Worked Example 1: LMTD Method for Exchanger Sizing
A double-pipe, counter-current heat exchanger is used to cool 0.5 kg/s 0.5 \text{ kg/s} 0.5 kg/s of an oil ( C p = 2200 J/(kg ⋅ K) C_{p} = 2200 \text{ J/(kg}\cdot \text{K)} C p = 2200 J/(kg ⋅ K) ) from 120 ∘ C 120^\circ\text{C} 12 0 ∘ C to 70 ∘ C 70^\circ\text{C} 7 0 ∘ C . Cooling water ( C p = 4180 J/(kg ⋅ K) C_p = 4180 \text{ J/(kg}\cdot \text{K)} C p = 4180 J/(kg ⋅ K) ) enters at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C and leaves at 55 ∘ C 55^\circ\text{C} 5 5 ∘ C . The overall heat transfer coefficient is U = 350 W/(m 2 ⋅ K) U = 350 \text{ W/(m}^2\cdot \text{K)} U = 350 W/(m 2 ⋅ K) . Calculate the required heat transfer area.
Step 1: Calculate the rate of heat transfer ( Q ˙ \dot{Q} Q ˙ ). Q ˙ = m ˙ o i l C p , o i l ( T h , i n − T h , o u t ) = 0.5 × 2200 × ( 120 − 70 ) = 55 , 000 W \dot{Q} = \dot{m}_{oil} C_{p,oil} (T_{h,in} - T_{h,out}) = 0.5 \times 2200 \times (120 - 70) = 55,000 \text{ W} Q ˙ = m ˙ o i l C p , o i l ( T h , in − T h , o u t ) = 0.5 × 2200 × ( 120 − 70 ) = 55 , 000 W
Step 2: Calculate the terminal temperature differences for counter-current flow.
Δ T 1 = T h , i n − T c , o u t = 120 − 55 = 65 ∘ C \Delta T_1 = T_{h,in} - T_{c,out} = 120 - 55 = 65^\circ\text{C} Δ T 1 = T h , in − T c , o u t = 120 − 55 = 6 5 ∘ C
Δ T 2 = T h , o u t − T c , i n = 70 − 20 = 50 ∘ C \Delta T_2 = T_{h,out} - T_{c,in} = 70 - 20 = 50^\circ\text{C} Δ T 2 = T h , o u t − T c , in = 70 − 20 = 5 0 ∘ C
Step 3: Calculate the LMTD ( Δ T l m \Delta T_{lm} Δ T l m ). Δ T l m = Δ T 1 − Δ T 2 ln ( Δ T 1 / Δ T 2 ) = 65 − 50 ln ( 65 / 50 ) = 15 0.2624 ≈ 57.17 ∘ C \Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} = \frac{65 - 50}{\ln(65 / 50)} = \frac{15}{0.2624} \approx 57.17^\circ\text{C} Δ T l m = ln ( Δ T 1 /Δ T 2 ) Δ T 1 − Δ T 2 = ln ( 65/50 ) 65 − 50 = 0.2624 15 ≈ 57.1 7 ∘ C
Step 4: Solve for the heat transfer area ( A A A ). Q ˙ = U A Δ T l m ⟹ A = Q ˙ U Δ T l m = 55 , 000 350 × 57.17 ≈ 2.75 m 2 \dot{Q} = U A \Delta T_{lm} \implies A = \frac{\dot{Q}}{U \Delta T_{lm}} = \frac{55,000}{350 \times 57.17} \approx 2.75 \text{ m}^2 Q ˙ = U A Δ T l m ⟹ A = U Δ T l m Q ˙ = 350 × 57.17 55 , 000 ≈ 2.75 m 2
The required heat transfer area is 2.75 m 2 2.75 \text{ m}^2 2.75 m 2 .
Worked Example 2: ε-NTU Method for Exchanger Rating
A counter-current heat exchanger with an area of 5.0 m 2 5.0 \text{ m}^2 5.0 m 2 and an overall heat transfer coefficient of U = 280 W/(m 2 ⋅ K) U = 280 \text{ W/(m}^2\cdot \text{K)} U = 280 W/(m 2 ⋅ K) is used to heat water ( C p = 4180 J/(kg ⋅ K) C_p = 4180 \text{ J/(kg}\cdot \text{K)} C p = 4180 J/(kg ⋅ K) ) flowing at 0.2 kg/s 0.2 \text{ kg/s} 0.2 kg/s . The heating fluid is an oil stream ( C p = 2000 J/(kg ⋅ K) C_p = 2000 \text{ J/(kg}\cdot \text{K)} C p = 2000 J/(kg ⋅ K) ) flowing at 0.3 kg/s 0.3 \text{ kg/s} 0.3 kg/s . The oil enters at 150 ∘ C 150^\circ\text{C} 15 0 ∘ C and the water enters at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C . Calculate the effectiveness of the exchanger and the heat transfer rate.
Step 1: Calculate the heat capacity rates.
C c = m ˙ c C p , c = 0.2 × 4180 = 836 W/K C_c = \dot{m}_c C_{p,c} = 0.2 \times 4180 = 836 \text{ W/K} C c = m ˙ c C p , c = 0.2 × 4180 = 836 W/K
C h = m ˙ h C p , h = 0.3 × 2000 = 600 W/K C_h = \dot{m}_h C_{p,h} = 0.3 \times 2000 = 600 \text{ W/K} C h = m ˙ h C p , h = 0.3 × 2000 = 600 W/K
Thus:
- C m i n = 600 W/K C_{min} = 600 \text{ W/K} C min = 600 W/K (oil)
- C m a x = 836 W/K C_{max} = 836 \text{ W/K} C ma x = 836 W/K (water)
C r = C m i n C m a x = 600 836 ≈ 0.718 C_r = \frac{C_{min}}{C_{max}} = \frac{600}{836} \approx 0.718 C r = C ma x C min = 836 600 ≈ 0.718
Step 2: Calculate the Number of Transfer Units ( N T U NTU NT U ). N T U = U A C m i n = 280 × 5.0 600 ≈ 2.333 NTU = \frac{U A}{C_{min}} = \frac{280 \times 5.0}{600} \approx 2.333 NT U = C min U A = 600 280 × 5.0 ≈ 2.333
Step 3: Calculate the effectiveness ( ϵ {\epsilon} ϵ ) for counter-current flow. ϵ = 1 − exp [ − N T U ( 1 − C r ) ] 1 − C r exp [ − N T U ( 1 − C r ) ] \epsilon = \frac{1 - \exp[-NTU(1 - C_r)]}{1 - C_r \exp[-NTU(1 - C_r)]} ϵ = 1 − C r exp [ − NT U ( 1 − C r )] 1 − exp [ − NT U ( 1 − C r )] N T U ( 1 − C r ) = 2.333 × ( 1 − 0.718 ) = 2.333 × 0.282 ≈ 0.658 NTU(1 - C_r) = 2.333 \times (1 - 0.718) = 2.333 \times 0.282 \approx 0.658 NT U ( 1 − C r ) = 2.333 × ( 1 − 0.718 ) = 2.333 × 0.282 ≈ 0.658 exp [ − 0.658 ] ≈ 0.518 \exp[-0.658] \approx 0.518 exp [ − 0.658 ] ≈ 0.518 ϵ = 1 − 0.518 1 − 0.718 × 0.518 = 0.482 1 − 0.372 = 0.482 0.628 ≈ 0.768 ( 76.8 % ) \epsilon = \frac{1 - 0.518}{1 - 0.718 \times 0.518} = \frac{0.482}{1 - 0.372} = \frac{0.482}{0.628} \approx 0.768 \quad (76.8\%) ϵ = 1 − 0.718 × 0.518 1 − 0.518 = 1 − 0.372 0.482 = 0.628 0.482 ≈ 0.768 ( 76.8% )
Step 4: Calculate the actual heat transfer rate ( Q ˙ \dot{Q} Q ˙ ). Q ˙ m a x = C m i n ( T h , i n − T c , i n ) = 600 × ( 150 − 20 ) = 78 , 000 W \dot{Q}_{max} = C_{min} (T_{h,in} - T_{c,in}) = 600 \times (150 - 20) = 78,000 \text{ W} Q ˙ ma x = C min ( T h , in − T c , in ) = 600 × ( 150 − 20 ) = 78 , 000 W Q ˙ = ϵ Q ˙ m a x = 0.768 × 78 , 000 = 59 , 904 W ≈ 59.9 kW \dot{Q} = \epsilon \dot{Q}_{max} = 0.768 \times 78,000 = 59,904 \text{ W} \approx 59.9 \text{ kW} Q ˙ = ϵ Q ˙ ma x = 0.768 × 78 , 000 = 59 , 904 W ≈ 59.9 kW
The heat transfer rate is 59.9 kW 59.9 \text{ kW} 59.9 kW .