Study guide

9.2 Heat Transfer Coefficients, Fouling, and Overall U

NCEES Fundamentals of Engineering FE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Mathematics

1.1 Analytic Geometry, Algebra, and Trigonometry 1.2 Calculus and Differential Equations 1.3 Numerical Methods and Measurement Error

2 Chapter 2: Probability and Statistics

2.1 Probability Distributions, Central Tendency, and Regression 2.2 Hypothesis Testing, ANOVA, and Statistical Quality Control

3 Chapter 3: Engineering Sciences

3.1 Mechanics and Dynamics 3.2 Electrical Circuits and Laws

4 Chapter 4: Materials Science

4.1 Material Properties and Compatibilities 4.2 Corrosion, Polymers, Ceramics, and Composites

5 Chapter 5: Chemistry and Biology

5.1 Stoichiometry, Analytical Chemistry, and Chemical Equilibrium 5.2 Organic Chemistry and Nomenclature 5.3 Biological Systems and Kinetics

6 Chapter 6: Fluid Mechanics and Dynamics

6.1 Fluid Properties, Dimensionless Numbers, and Flow Regimes 6.2 Bernoulli Equation and Mechanical Energy Balances 6.3 Flow Measurement and Fluid Machinery 6.4 Compressible and Non-Newtonian Flows

7 Chapter 7: Thermodynamics

7.1 Thermodynamic Properties, Ideal Gas, and State Equations 7.2 Laws of Thermodynamics and Cyclic Processes 7.3 Vapor-Liquid Equilibrium (VLE) and Phase Equilibrium 7.4 Chemical Equilibrium, Heats of Reaction, and Mixing

8 Chapter 8: Material and Energy Balances

8.1 Steady-State Material Balances 8.2 Unsteady-State Mass Balances 8.3 Steady-State Energy Balances 8.4 Unsteady-State Energy Balances

9 Chapter 9: Heat Transfer

9.1 Conduction, Convection, and Radiation Fundamentals 9.2 Heat Transfer Coefficients, Fouling, and Overall U 9.3 Heat Exchanger Design

10 Chapter 10: Mass Transfer and Separation

10.1 Diffusion Fundamentals 10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction 10.3 Distillation and McCabe-Thiele Method 10.4 Continuous Contact Methods, Membrane Separations, and Evaporative Operations

11 Chapter 11: Solids Handling

11.1 Particle Properties and Solid Processing 11.2 Solids Transportation and Storage

12 Chapter 12: Chemical Reaction Engineering

12.1 Reaction Kinetics and Performance Metrics 12.2 Ideal Reactor Design 12.3 Multiple Reactions, Catalysis, and Heterogeneous Kinetics

13 Chapter 13: Economics

13.1 Time Value of Money and Project Selection 13.2 Profitability Analysis, Depreciation, and Break-Even

14 Chapter 14: Process Design

14.1 Process Flowsheets and Instrumentation 14.2 Equipment Selection, Sizing, and Cost Estimation 14.3 Process Optimization, Sustainability, and Inherently Safer Design

15 Chapter 15: Process Control

15.1 Process Dynamics and Transfer Functions 15.2 Feedback Control Loops, PID Tuning, and Control Hardware

16 Chapter 16: Safety, Health, and Environment

16.1 Flammability, Toxicity, and Industrial Hygiene 16.2 Hazard Identification and Risk Analysis 16.3 Overpressure Relief, Reactivity Hazards, and Waste Regulations

17 Chapter 17: Ethics and Professional Practice

17.1 Professional Codes of Ethics and Public Welfare 17.2 Intellectual Property, Contracts, and Professional Liability

9.2 Heat Transfer Coefficients, Fouling, and Overall U

Key Takeaways Explain This Topic AI

The overall heat transfer coefficient U accounts for both convective boundary layers and conductive solid wall resistances in series

Thermal resistances are analogous to electrical resistances: series resistances add directly, while parallel resistances combine reciprocally

In cylindrical geometries, heat transfer area varies with radius, meaning overall U must be referenced to a specific area: U_i A_i = U_o A_o = 1/R_total

Fouling factors (R_f) represent thermal resistance due to scale and deposits, reducing U according to 1/U_dirty = 1/U_clean + R_f

Last updated: July 2026

9.2 Heat Transfer Coefficients, Fouling, and Overall U

In process plants, heat transfer rarely occurs through a single, isolated material layer. More commonly, heat is transferred from a hot fluid through a solid wall (which may be multi-layered or insulated) and then to a cold fluid. To analyze such composite systems, chemical engineers utilize local and overall heat transfer coefficients along with the thermal resistance network method. This section covers the formulation of overall heat transfer coefficients ( U U U ), series and parallel thermal resistances, cylindrical geometries, and the impacts of fouling factors.

Convection Heat Transfer Coefficients

The convective heat transfer rate between a solid surface and a fluid is governed by Newton's Law of Cooling, written as Q ˙ = h A ( T s − T ∞ ) \dot{Q} = h A (T_s - T_\infty) Q ˙ ​ = h A ( T s ​ − T ∞ ​ ) . The term h h h is the convective heat transfer coefficient.

Local convective coefficient ( h l o c a l h_{local} h l oc a l ​ ) : Represents the heat transfer rate at a specific point on the surface, which varies due to the development of velocity and thermal boundary layers.

Average convective coefficient ( h h h ) : The integrated average coefficient over the entire heat transfer area, used for macroscopic energy balances.

Thermal Resistance Network

The thermal resistance analogy is a powerful framework modeled after electrical circuits. The temperature difference ( Δ T \Delta T Δ T ) acts as the driving potential (voltage), the heat transfer rate ( Q ˙ \dot{Q} Q ˙ ​ ) represents the thermal current (electric current), and the thermal resistance ( R t h R_{th} R t h ​ ) represents the resistance. Q ˙ = Δ T R t o t a l \dot{Q} = \frac{\Delta T}{R_{total}} Q ˙ ​ = R t o t a l ​ Δ T ​

Depending on the system configuration, thermal resistances can combine in series, parallel, or a combination of both.

Series Resistances

For a series heat transfer path (such as a composite plane wall), the heat must pass through each layer sequentially. The total thermal resistance is the sum of the individual resistances: R t o t a l = ∑ R i = R 1 + R 2 + R 3 + … R_{total} = \sum R_i = R_1 + R_2 + R_3 + \dots R t o t a l ​ = ∑ R i ​ = R 1 ​ + R 2 ​ + R 3 ​ + …

Under steady-state conditions, the rate of heat transfer is constant through all layers, allowing interface temperatures to be solved by equating heat rates across individual barriers.

Parallel Resistances

For a parallel heat transfer path (such as a wall with structural studs or different materials side-by-side), the heat can flow through multiple pathways simultaneously. The overall thermal resistance is combined reciprocally: 1 R t o t a l = ∑ 1 R i ⟹ R t o t a l = ( 1 R 1 + 1 R 2 + … ) − 1 \frac{1}{R_{total}} = \sum \frac{1}{R_i} \implies R_{total} = \left( \frac{1}{R_1} + \frac{1}{R_2} + \dots \right)^{-1} R t o t a l ​ 1 ​ = ∑ R i ​ 1 ​ ⟹ R t o t a l ​ = ( R 1 ​ 1 ​ + R 2 ​ 1 ​ + … ) − 1

  • Expressions for Common Thermal Resistances
  • Conduction Resistance (Plane Wall) : R c o n d = L k A R_{cond} = \frac{L}{k A} R co n d ​ = k A L ​

Conduction Resistance (Cylindrical Wall) : R c y l = ln ⁡ ( r o / r i ) 2 π k L R_{cyl} = \frac{\ln(r_o/r_i)}{2 \pi k L} R cy l ​ = 2 πk L ln ( r o ​ / r i ​ ) ​

  • Convection Resistance : R c o n v = 1 h A R_{conv} = \frac{1}{h A} R co n v ​ = h A 1 ​
  • Overall Heat Transfer Coefficient (U)

The overall heat transfer coefficient ( U U U ) is defined as the reciprocal of the total thermal resistance scaled by the heat transfer area: Q ˙ = U A Δ T o v e r a l l \dot{Q} = U A \Delta T_{overall} Q ˙ ​ = U A Δ T o v er a ll ​ U A = 1 R t o t a l ⟹ U = 1 A R t o t a l U A = \frac{1}{R_{total}} \implies U = \frac{1}{A R_{total}} U A = R t o t a l ​ 1 ​ ⟹ U = A R t o t a l ​ 1 ​

For flat walls where the area ( A A A ) is constant across all layers, U U U is independent of position. For a flat plate with convection on both sides and N N N solid layers in series, the overall coefficient is: 1 U = 1 h i + ∑ j = 1 N L j k j + 1 h o \frac{1}{U} = \frac{1}{h_i} + \sum_{j=1}^N \frac{L_j}{k_j} + \frac{1}{h_o} U 1 ​ = h i ​ 1 ​ + j = 1 ∑ N ​ k j ​ L j ​ ​ + h o ​ 1 ​

Cylindrical Geometries and Area-Dependent Overall U

In radial coordinates (e.g., pipes and tubes), the heat transfer area increases with radius ( A = 2 π r L A = 2\pi r L A = 2 π r L ). Consequently, the overall heat transfer coefficient must be defined with respect to a specific reference area—typically the inner surface area ( A i A_i A i ​ ) or the outer surface area ( A o A_o A o ​ ).

Because the total heat transfer rate Q ˙ \dot{Q} Q ˙ ​ is constant, the relation is: Q ˙ = U i A i Δ T = U o A o Δ T ⟹ U i A i = U o A o = 1 R t o t a l \dot{Q} = U_i A_i \Delta T = U_o A_o \Delta T \implies U_i A_i = U_o A_o = \frac{1}{R_{total}} Q ˙ ​ = U i ​ A i ​ Δ T = U o ​ A o ​ Δ T ⟹ U i ​ A i ​ = U o ​ A o ​ = R t o t a l ​ 1 ​

Consider a pipe with inner radius r i r_i r i ​ , outer radius r o r_o r o ​ , thermal conductivity k k k , length L L L , and convective coefficients h i h_i h i ​ (internal) and h o h_o h o ​ (external). The total thermal resistance is: R t o t a l = R c o n v , i + R c o n d , p i p e + R c o n v , o = 1 h i A i + ln ⁡ ( r o / r i ) 2 π k L + 1 h o A o R_{total} = R_{conv, i} + R_{cond, pipe} + R_{conv, o} = \frac{1}{h_i A_i} + \frac{\ln(r_o/r_i)}{2\pi k L} + \frac{1}{h_o A_o} R t o t a l ​ = R co n v , i ​ + R co n d , p i p e ​ + R co n v , o ​ = h i ​ A i ​ 1 ​ + 2 πk L ln ( r o ​ / r i ​ ) ​ + h o ​ A o ​ 1 ​

Thus, the overall heat transfer coefficient based on the outer area A o = 2 π r o L A_o = 2\pi r_o L A o ​ = 2 π r o ​ L is: 1 U o = A o R t o t a l = A o h i A i + A o ln ⁡ ( r o / r i ) 2 π k L + A o h o A o \frac{1}{U_o} = A_o R_{total} = \frac{A_o}{h_i A_i} + \frac{A_o \ln(r_o/r_i)}{2\pi k L} + \frac{A_o}{h_o A_o} U o ​ 1 ​ = A o ​ R t o t a l ​ = h i ​ A i ​ A o ​ ​ + 2 πk L A o ​ ln ( r o ​ / r i ​ ) ​ + h o ​ A o ​ A o ​ ​ 1 U o = r o r i h i + r o ln ⁡ ( r o / r i ) k + 1 h o \frac{1}{U_o} = \frac{r_o}{r_i h_i} + \frac{r_o \ln(r_o/r_i)}{k} + \frac{1}{h_o} U o ​ 1 ​ = r i ​ h i ​ r o ​ ​ + k r o ​ ln ( r o ​ / r i ​ ) ​ + h o ​ 1 ​

Similarly, based on the inner area A i = 2 π r i L A_i = 2\pi r_i L A i ​ = 2 π r i ​ L : 1 U i = A i R t o t a l = 1 h i + r i ln ⁡ ( r o / r i ) k + r i r o h o \frac{1}{U_i} = A_i R_{total} = \frac{1}{h_i} + \frac{r_i \ln(r_o/r_i)}{k} + \frac{r_i}{r_o h_o} U i ​ 1 ​ = A i ​ R t o t a l ​ = h i ​ 1 ​ + k r i ​ ln ( r o ​ / r i ​ ) ​ + r o ​ h o ​ r i ​ ​

Fouling Factors

Over time, heat exchanger surfaces accumulate deposits such as mineral scale, rust, soot, or biological slime. This layer of deposits introduces an additional thermal resistance, known as the fouling resistance .

The fouling resistance is expressed using a fouling factor ( R f R_f R f ​ ), which has units of m 2 ⋅ K/W \text{m}^2\cdot \text{K/W} m 2 ⋅ K/W (or h ⋅ ft 2 ⋅ °F/Btu \text{h}\cdot \text{ft}^2\cdot \text{°F/Btu} h ⋅ ft 2 ⋅ °F/Btu ): R f o u l i n g = R f A R_{fouling} = \frac{R_f}{A} R f o u l in g ​ = A R f ​ ​

When fouling occurs on both the inner and outer surfaces of a tube, these resistances are added in series to the overall resistance network: R t o t a l = 1 h i A i + R f , i A i + ln ⁡ ( r o / r i ) 2 π k L + R f , o A o + 1 h o A o R_{total} = \frac{1}{h_i A_i} + \frac{R_{f,i}}{A_i} + \frac{\ln(r_o/r_i)}{2\pi k L} + \frac{R_{f,o}}{A_o} + \frac{1}{h_o A_o} R t o t a l ​ = h i ​ A i ​ 1 ​ + A i ​ R f , i ​ ​ + 2 πk L ln ( r o ​ / r i ​ ) ​ + A o ​ R f , o ​ ​ + h o ​ A o ​ 1 ​

Based on the outer area A o A_o A o ​ , the dirty overall heat transfer coefficient ( U o , d i r t y U_{o,dirty} U o , d i r t y ​ ) is related to the clean overall coefficient ( U o , c l e a n U_{o,clean} U o , c l e an ​ ) by: 1 U o , d i r t y = 1 U o , c l e a n + R f , i ( r o r i ) + R f , o \frac{1}{U_{o,dirty}} = \frac{1}{U_{o,clean}} + R_{f,i}\left(\frac{r_o}{r_i}\right) + R_{f,o} U o , d i r t y ​ 1 ​ = U o , c l e an ​ 1 ​ + R f , i ​ ( r i ​ r o ​ ​ ) + R f , o ​

  • Worked Examples
  • Worked Example 1: Composite Wall Interface Temperatures

A furnace wall is constructed of 0.12 m 0.12 \text{ m} 0.12 m of firebrick ( k 1 = 1.4 W/(m ⋅ K) k_1 = 1.4 \text{ W/(m}\cdot \text{K)} k 1 ​ = 1.4 W/(m ⋅ K) ) and 0.08 m 0.08 \text{ m} 0.08 m of insulating brick ( k 2 = 0.2 W/(m ⋅ K) k_2 = 0.2 \text{ W/(m}\cdot \text{K)} k 2 ​ = 0.2 W/(m ⋅ K) ). The hot gas inside the furnace is at 900 ∘ C 900^\circ\text{C} 90 0 ∘ C with a convective coefficient of h i = 30 W/(m 2 ⋅ K) h_i = 30 \text{ W/(m}^2\cdot \text{K)} h i ​ = 30 W/(m 2 ⋅ K) . The ambient air outside is at 30 ∘ C 30^\circ\text{C} 3 0 ∘ C with a convective coefficient of h o = 10 W/(m 2 ⋅ K) h_o = 10 \text{ W/(m}^2\cdot \text{K)} h o ​ = 10 W/(m 2 ⋅ K) . Calculate the steady-state heat loss per unit area ( q ′ ′ q'' q ′′ ) and the temperature at the interface between the two bricks.

Step 1: Calculate the individual thermal resistances per unit area ( R ′ ′ = R ⋅ A R'' = R \cdot A R ′′ = R ⋅ A ).

Inner convection: R c o n v , i ′ ′ = 1 h i = 1 30 ≈ 0.0333 m 2 ⋅ K/W R''_{conv, i} = \frac{1}{h_i} = \frac{1}{30} \approx 0.0333 \text{ m}^2\cdot \text{K/W} R co n v , i ′′ ​ = h i ​ 1 ​ = 30 1 ​ ≈ 0.0333 m 2 ⋅ K/W

Firebrick conduction: R c o n d , 1 ′ ′ = L 1 k 1 = 0.12 1.4 ≈ 0.0857 m 2 ⋅ K/W R''_{cond, 1} = \frac{L_1}{k_1} = \frac{0.12}{1.4} \approx 0.0857 \text{ m}^2\cdot \text{K/W} R co n d , 1 ′′ ​ = k 1 ​ L 1 ​ ​ = 1.4 0.12 ​ ≈ 0.0857 m 2 ⋅ K/W

Insulation conduction: R c o n d , 2 ′ ′ = L 2 k 2 = 0.08 0.2 = 0.4000 m 2 ⋅ K/W R''_{cond, 2} = \frac{L_2}{k_2} = \frac{0.08}{0.2} = 0.4000 \text{ m}^2\cdot \text{K/W} R co n d , 2 ′′ ​ = k 2 ​ L 2 ​ ​ = 0.2 0.08 ​ = 0.4000 m 2 ⋅ K/W

Outer convection: R c o n v , o ′ ′ = 1 h o = 1 10 = 0.1000 m 2 ⋅ K/W R''_{conv, o} = \frac{1}{h_o} = \frac{1}{10} = 0.1000 \text{ m}^2\cdot \text{K/W} R co n v , o ′′ ​ = h o ​ 1 ​ = 10 1 ​ = 0.1000 m 2 ⋅ K/W

Step 2: Calculate the total thermal resistance per unit area. R t o t a l ′ ′ = R c o n v , i ′ ′ + R c o n d , 1 ′ ′ + R c o n d , 2 ′ ′ + R c o n v , o ′ ′ R''_{total} = R''_{conv, i} + R''_{cond, 1} + R''_{cond, 2} + R''_{conv, o} R t o t a l ′′ ​ = R co n v , i ′′ ​ + R co n d , 1 ′′ ​ + R co n d , 2 ′′ ​ + R co n v , o ′′ ​ R t o t a l ′ ′ = 0.0333 + 0.0857 + 0.4000 + 0.1000 = 0.6190 m 2 ⋅ K/W R''_{total} = 0.0333 + 0.0857 + 0.4000 + 0.1000 = 0.6190 \text{ m}^2\cdot\text{K/W} R t o t a l ′′ ​ = 0.0333 + 0.0857 + 0.4000 + 0.1000 = 0.6190 m 2 ⋅ K/W

Step 3: Calculate the heat flux ( q ′ ′ q'' q ′′ ). q ′ ′ = T ∞ , i − T ∞ , o R t o t a l ′ ′ = 900 − 30 0.6190 ≈ 1405.5 W/m 2 q'' = \frac{T_{\infty, i} - T_{\infty, o}}{R''_{total}} = \frac{900 - 30}{0.6190} \approx 1405.5 \text{ W/m}^2 q ′′ = R t o t a l ′′ ​ T ∞ , i ​ − T ∞ , o ​ ​ = 0.6190 900 − 30 ​ ≈ 1405.5 W/m 2

Step 4: Solve for the interface temperature ( T i n t T_{int} T in t ​ ).

The temperature drop from the hot gas to the interface is: T ∞ , i − T i n t = q ′ ′ ( R c o n v , i ′ ′ + R c o n d , 1 ′ ′ ) T_{\infty, i} - T_{int} = q'' (R''_{conv, i} + R''_{cond, 1}) T ∞ , i ​ − T in t ​ = q ′′ ( R co n v , i ′′ ​ + R co n d , 1 ′′ ​ ) 900 − T i n t = 1405.5 × ( 0.0333 + 0.0857 ) = 1405.5 × 0.1190 ≈ 167.3 ∘ C 900 - T_{int} = 1405.5 \times (0.0333 + 0.0857) = 1405.5 \times 0.1190 \approx 167.3^\circ\text{C} 900 − T in t ​ = 1405.5 × ( 0.0333 + 0.0857 ) = 1405.5 × 0.1190 ≈ 167. 3 ∘ C T i n t = 900 − 167.3 = 732.7 ∘ C T_{int} = 900 - 167.3 = 732.7^\circ\text{C} T in t ​ = 900 − 167.3 = 732. 7 ∘ C

Worked Example 2: Overall U of a Condenser Tube with Fouling

Water flows inside a copper tube ( k w a l l = 400 W/(m ⋅ K) k_{wall} = 400 \text{ W/(m}\cdot \text{K)} k w a ll ​ = 400 W/(m ⋅ K) , r i = 9.0 mm r_i = 9.0 \text{ mm} r i ​ = 9.0 mm , r o = 10.0 mm r_o = 10.0 \text{ mm} r o ​ = 10.0 mm ) while steam condenses on the outer surface. The convective heat transfer coefficients are h i = 4000 W/(m 2 ⋅ K) h_i = 4000 \text{ W/(m}^2\cdot \text{K)} h i ​ = 4000 W/(m 2 ⋅ K) and h o = 10000 W/(m 2 ⋅ K) h_o = 10000 \text{ W/(m}^2\cdot \text{K)} h o ​ = 10000 W/(m 2 ⋅ K) . The inner fouling factor is R f , i = 0.0001 m 2 ⋅ K/W R_{f,i} = 0.0001 \text{ m}^2\cdot \text{K/W} R f , i ​ = 0.0001 m 2 ⋅ K/W and the outer fouling factor is neglected. Calculate the overall heat transfer coefficient based on the outer area ( U o U_o U o ​ ).

Step 1: Set up the equation for 1 / U o 1/U_o 1/ U o ​ . 1 U o = r o r i h i + R f , i ( r o r i ) + r o ln ⁡ ( r o / r i ) k w a l l + 1 h o \frac{1}{U_o} = \frac{r_o}{r_i h_i} + R_{f,i}\left(\frac{r_o}{r_i}\right) + \frac{r_o \ln(r_o/r_i)}{k_{wall}} + \frac{1}{h_o} U o ​ 1 ​ = r i ​ h i ​ r o ​ ​ + R f , i ​ ( r i ​ r o ​ ​ ) + k w a ll ​ r o ​ ln ( r o ​ / r i ​ ) ​ + h o ​ 1 ​

Step 2: Substitute the known values (convert radii to meters).

  • r i = 0.009 m r_i = 0.009 \text{ m} r i ​ = 0.009 m
  • r o = 0.010 m r_o = 0.010 \text{ m} r o ​ = 0.010 m

r o / r i = 10 / 9 ≈ 1.111 r_o / r_i = 10 / 9 \approx 1.111 r o ​ / r i ​ = 10/9 ≈ 1.111 r o r i h i = 1.111 4000 ≈ 0.000278 m 2 ⋅ K/W \frac{r_o}{r_i h_i} = \frac{1.111}{4000} \approx 0.000278 \text{ m}^2\cdot\text{K/W} r i ​ h i ​ r o ​ ​ = 4000 1.111 ​ ≈ 0.000278 m 2 ⋅ K/W R f , i ( r o r i ) = 0.0001 × 1.111 ≈ 0.000111 m 2 ⋅ K/W R_{f,i}\left(\frac{r_o}{r_i}\right) = 0.0001 \times 1.111 \approx 0.000111 \text{ m}^2\cdot\text{K/W} R f , i ​ ( r i ​ r o ​ ​ ) = 0.0001 × 1.111 ≈ 0.000111 m 2 ⋅ K/W r o ln ⁡ ( r o / r i ) k w a l l = 0.010 × ln ⁡ ( 1.111 ) 400 = 0.010 × 0.10536 400 ≈ 2.63 × 10 − 6 m 2 ⋅ K/W \frac{r_o \ln(r_o/r_i)}{k_{wall}} = \frac{0.010 \times \ln(1.111)}{400} = \frac{0.010 \times 0.10536}{400} \approx 2.63 \times 10^{-6} \text{ m}^2\cdot\text{K/W} k w a ll ​ r o ​ ln ( r o ​ / r i ​ ) ​ = 400 0.010 × ln ( 1.111 ) ​ = 400 0.010 × 0.10536 ​ ≈ 2.63 × 1 0 − 6 m 2 ⋅ K/W 1 h o = 1 10000 = 0.000100 m 2 ⋅ K/W \frac{1}{h_o} = \frac{1}{10000} = 0.000100 \text{ m}^2\cdot\text{K/W} h o ​ 1 ​ = 10000 1 ​ = 0.000100 m 2 ⋅ K/W

Step 3: Sum the terms to find 1 / U o 1/U_o 1/ U o ​ . 1 U o = 0.000278 + 0.000111 + 0.00000263 + 0.000100 ≈ 0.0004916 m 2 ⋅ K/W \frac{1}{U_o} = 0.000278 + 0.000111 + 0.00000263 + 0.000100 \approx 0.0004916 \text{ m}^2\cdot\text{K/W} U o ​ 1 ​ = 0.000278 + 0.000111 + 0.00000263 + 0.000100 ≈ 0.0004916 m 2 ⋅ K/W

Step 4: Take the reciprocal to find U o U_o U o ​ . U o = 1 0.0004916 ≈ 2034 W/(m 2 ⋅ K) U_o = \frac{1}{0.0004916} \approx 2034 \text{ W/(m}^2\cdot\text{K)} U o ​ = 0.0004916 1 ​ ≈ 2034 W/(m 2 ⋅ K)

The overall heat transfer coefficient based on the outer surface area is 2034 W/(m 2 ⋅ K) 2034 \text{ W/(m}^2\cdot \text{K)} 2034 W/(m 2 ⋅ K) .