Study guide

10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction

NCEES Fundamentals of Engineering FE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Mathematics

1.1 Analytic Geometry, Algebra, and Trigonometry 1.2 Calculus and Differential Equations 1.3 Numerical Methods and Measurement Error

2 Chapter 2: Probability and Statistics

2.1 Probability Distributions, Central Tendency, and Regression 2.2 Hypothesis Testing, ANOVA, and Statistical Quality Control

3 Chapter 3: Engineering Sciences

3.1 Mechanics and Dynamics 3.2 Electrical Circuits and Laws

4 Chapter 4: Materials Science

4.1 Material Properties and Compatibilities 4.2 Corrosion, Polymers, Ceramics, and Composites

5 Chapter 5: Chemistry and Biology

5.1 Stoichiometry, Analytical Chemistry, and Chemical Equilibrium 5.2 Organic Chemistry and Nomenclature 5.3 Biological Systems and Kinetics

6 Chapter 6: Fluid Mechanics and Dynamics

6.1 Fluid Properties, Dimensionless Numbers, and Flow Regimes 6.2 Bernoulli Equation and Mechanical Energy Balances 6.3 Flow Measurement and Fluid Machinery 6.4 Compressible and Non-Newtonian Flows

7 Chapter 7: Thermodynamics

7.1 Thermodynamic Properties, Ideal Gas, and State Equations 7.2 Laws of Thermodynamics and Cyclic Processes 7.3 Vapor-Liquid Equilibrium (VLE) and Phase Equilibrium 7.4 Chemical Equilibrium, Heats of Reaction, and Mixing

8 Chapter 8: Material and Energy Balances

8.1 Steady-State Material Balances 8.2 Unsteady-State Mass Balances 8.3 Steady-State Energy Balances 8.4 Unsteady-State Energy Balances

9 Chapter 9: Heat Transfer

9.1 Conduction, Convection, and Radiation Fundamentals 9.2 Heat Transfer Coefficients, Fouling, and Overall U 9.3 Heat Exchanger Design

10 Chapter 10: Mass Transfer and Separation

10.1 Diffusion Fundamentals 10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction 10.3 Distillation and McCabe-Thiele Method 10.4 Continuous Contact Methods, Membrane Separations, and Evaporative Operations

11 Chapter 11: Solids Handling

11.1 Particle Properties and Solid Processing 11.2 Solids Transportation and Storage

12 Chapter 12: Chemical Reaction Engineering

12.1 Reaction Kinetics and Performance Metrics 12.2 Ideal Reactor Design 12.3 Multiple Reactions, Catalysis, and Heterogeneous Kinetics

13 Chapter 13: Economics

13.1 Time Value of Money and Project Selection 13.2 Profitability Analysis, Depreciation, and Break-Even

14 Chapter 14: Process Design

14.1 Process Flowsheets and Instrumentation 14.2 Equipment Selection, Sizing, and Cost Estimation 14.3 Process Optimization, Sustainability, and Inherently Safer Design

15 Chapter 15: Process Control

15.1 Process Dynamics and Transfer Functions 15.2 Feedback Control Loops, PID Tuning, and Control Hardware

16 Chapter 16: Safety, Health, and Environment

16.1 Flammability, Toxicity, and Industrial Hygiene 16.2 Hazard Identification and Risk Analysis 16.3 Overpressure Relief, Reactivity Hazards, and Waste Regulations

17 Chapter 17: Ethics and Professional Practice

17.1 Professional Codes of Ethics and Public Welfare 17.2 Intellectual Property, Contracts, and Professional Liability

10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction

Key Takeaways Explain This Topic AI

Gas absorption transfers solute from gas to liquid ( y > y ∗ y > y^* y > y ∗ ), while stripping transfers solute from liquid to gas ( y < y ∗ y < y^* y < y ∗ ).

The operating line for dilute countercurrent columns is y = ( L / G ) x + ( y 2 − ( L / G ) x 2 ) y = (L/G)x + (y_2 - (L/G)x_2) y = ( L / G ) x + ( y 2 ​ − ( L / G ) x 2 ​ ) , which lies above the equilibrium curve for absorption and below it for stripping.

The minimum liquid-to-gas ratio ( L / G ) min ⁡ (L/G)_{\min} ( L / G ) m i n ​ occurs when the operating line touches the equilibrium curve at a pinch point, requiring infinite stages.

Liquid-liquid extraction separations are analyzed using triangular ternary phase diagrams containing a binodal solubility curve and tie lines.

The plait point represents the composition where the extract and raffinate phases become identical and the tie line length shrinks to zero.

Last updated: July 2026

10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction

Gas absorption, stripping, and liquid-liquid extraction are key separation processes that involve mass transfer of a solute between two phases. On the FE Chemical exam, questions typically focus on mass balances, equilibrium relationships, operating lines, finding minimum solvent or gas rates, and interpreting ternary extraction diagrams.

Gas Absorption and Stripping Fundamentals

Gas absorption is a process where a gas mixture is contacted with a liquid solvent to selectively dissolve one or more soluble components (solutes) from the gas. Stripping (or desorption) is the physical reverse of absorption, where a liquid mixture is contacted with a gas stream to transfer a solute from the liquid phase into the gas phase.

In a typical industrial column (usually packed or trayed), flow is countercurrent: liquid enters at the top and flows downwards, while gas enters at the bottom and flows upwards.

Equilibrium and Henry's Law

For dilute systems, the equilibrium relationship between the mole fraction of solute in the gas phase ( y ∗ y^* y ∗ ) and the liquid phase ( x x x ) is linear, described by Henry's Law: y ∗ = m x y^* = m x y ∗ = m x

Where:

y ∗ y^* y ∗ is the equilibrium mole fraction of solute in the vapor phase.

x x x is the mole fraction of solute in the liquid phase.

m m m is the equilibrium constant (Henry's law slope).

Molar Material Balances

Consider a countercurrent column where:

The bottom is designated as Stage 1 and the top as Stage 2.

Gas enters the bottom at molar flow rate G G G with solute mole fraction y 1 y_1 y 1 ​ .

Gas leaves the top at molar flow rate G G G with solute mole fraction y 2 y_2 y 2 ​ .

Liquid enters the top at molar flow rate L L L with solute mole fraction x 2 x_2 x 2 ​ .

Liquid leaves the bottom at molar flow rate L L L with solute mole fraction x 1 x_1 x 1 ​ .

For dilute systems (typically solute mole fractions < 5 % < 5\% < 5% ), the total gas and liquid flow rates G G G and L L L remain approximately constant. A mass balance over the entire column yields: L x 2 + G y 1 = L x 1 + G y 2 ⟹ G ( y 1 − y 2 ) = L ( x 1 − x 2 ) L x_2 + G y_1 = L x_1 + G y_2 \implies G(y_1 - y_2) = L(x_1 - x_2) L x 2 ​ + G y 1 ​ = L x 1 ​ + G y 2 ​ ⟹ G ( y 1 ​ − y 2 ​ ) = L ( x 1 ​ − x 2 ​ )

A mass balance from the top of the column to an arbitrary cross-section gives the Operating Line equation : y = L G x + ( y 2 − L G x 2 ) y = \frac{L}{G} x + \left( y_2 - \frac{L}{G} x_2 \right) y = G L ​ x + ( y 2 ​ − G L ​ x 2 ​ )

This operating line represents the actual vapor and liquid compositions passing each other at any point in the column.

Absorption vs. Stripping Operating Lines

Absorption: Solute is transferred from the gas phase to the liquid. Therefore, at any point in the column, the actual gas phase concentration y y y must be higher than the equilibrium concentration y ∗ y^* y ∗ in contact with liquid concentration x x x . The operating line lies above the equilibrium line ( y > m x y > m x y > m x ).

Stripping: Solute is transferred from the liquid phase to the gas. Therefore, the actual liquid phase concentration x x x must be higher than the equilibrium concentration x ∗ x^* x ∗ in contact with gas concentration y y y . The operating line lies below the equilibrium line ( y < m x y < m x y < m x ).

Minimum Liquid-to-Gas Flow Rate ( L / G ) min ⁡ (L/G)_{\min} ( L / G ) m i n ​ in Absorption

In gas absorption, the liquid solvent rate L L L represents an operating cost (since the solvent must be regenerated or disposed of). Decreasing L L L for a fixed gas rate G G G decreases the slope of the operating line ( L / G L/G L / G ).

If the liquid flow rate is decreased too much, the operating line will rotate downwards until it touches the equilibrium line. The point of contact is called the pinch point . At the pinch point, the operating line and the equilibrium line intersect, meaning the concentration driving force ( y − y ∗ ) (y - y^*) ( y − y ∗ ) becomes zero. According to mass transfer principles, a driving force of zero requires an infinite column height (or infinite equilibrium stages) to achieve the desired separation.

For a linear equilibrium curve ( y ∗ = m x y^* = m x y ∗ = m x ) and an absorber with a solute-free liquid feed ( x 2 = 0 x_2 = 0 x 2 ​ = 0 ), the pinch point occurs at the bottom of the column where the liquid leaving ( x 1 x_1 x 1 ​ ) is in equilibrium with the entering gas ( y 1 y_1 y 1 ​ ). Thus, the maximum possible liquid concentration at the outlet is: x 1 ∗ = y 1 m x_1^* = \frac{y_1}{m} x 1 ∗ ​ = m y 1 ​ ​

The minimum liquid-to-gas flow rate ratio is calculated by connecting the inlet liquid composition point ( x 2 , y 2 ) (x_2, y_2) ( x 2 ​ , y 2 ​ ) to this equilibrium point ( x 1 ∗ , y 1 ) (x_1^*, y_1) ( x 1 ∗ ​ , y 1 ​ ) : ( L G ) min ⁡ = y 1 − y 2 x 1 ∗ − x 2 = y 1 − y 2 ( y 1 / m ) − x 2 \left(\frac{L}{G}\right)_{\min} = \frac{y_1 - y_2}{x_1^* - x_2} = \frac{y_1 - y_2}{(y_1 / m) - x_2} ( G L ​ ) m i n ​ = x 1 ∗ ​ − x 2 ​ y 1 ​ − y 2 ​ ​ = ( y 1 ​ / m ) − x 2 ​ y 1 ​ − y 2 ​ ​

Exam Tip: In practice, the operating liquid rate is set to 1.2 1.2 1.2 to 1.5 1.5 1.5 times the minimum liquid rate. If the liquid flow rate is below L min ⁡ L_{\min} L m i n ​ , the desired separation is physically impossible.

Liquid-Liquid Extraction (LLE)

Liquid-liquid extraction separates a solute from a liquid mixture (carrier) by contacting it with another immiscible or partially miscible liquid solvent that has a higher affinity for the solute.

Ternary Systems

LLE involves three components:

Solute ( A A A ): The component being separated.

Carrier ( B B B ): The original solvent containing the solute.

Extracting Solvent ( C C C ): The added liquid solvent.

The separation yields two phases:

Extract phase: The solvent-rich phase containing the extracted solute.

Raffinate phase: The residual carrier-rich phase depleted of solute.

Ternary Phase Diagrams

Ternary mixtures are represented on an equilateral triangular diagram, where each vertex represents 100 % 100\% 100% of a pure component ( A A A , B B B , or C C C ).

Binodal Curve (Solubility Curve): The envelope dividing the single-phase homogeneous region (outside/above the curve) from the two-phase heterogeneous region (inside the curve).

Tie Lines: Straight lines within the two-phase region that connect the compositions of the raffinate phase ( R R R , on the carrier-rich side of the curve) and the extract phase ( E E E , on the solvent-rich side of the curve) that are in equilibrium.

Plait Point: The point on the binodal curve where the raffinate and extract compositions become identical. At the plait point, the tie line length shrinks to zero.

Lever-Arm Rule: For a feed mixture M M M that splits into raffinate R R R and extract E E E , the ratio of the mass of the phases is given by: Mass of Raffinate (R) Mass of Extract (E) = M E ‾ M R ‾ \frac{\text{Mass of Raffinate (R)}}{\text{Mass of Extract (E)}} = \frac{\overline{ME}}{\overline{MR}} Mass of Extract (E) Mass of Raffinate (R) ​ = MR ME ​

Where M E ‾ \overline{ME} ME is the length of the segment from M M M to E E E , and M R ‾ \overline{MR} MR is the length of the segment from M M M to R R R along the tie line passing through M M M .

Worked Example: Minimum Solvent Rate for an Absorber

Problem: A countercurrent packed column is designed to absorb hydrogen sulfide ( H 2 S \text{H}_2\text{S} H 2 ​ S ) from a gas stream using pure water. The entering gas contains 4.0 mol % H 2 S 4.0\text{ mol}\%\text{ H}_2\text{S} 4.0 mol % H 2 ​ S ( y 1 = 0.040 y_1 = 0.040 y 1 ​ = 0.040 ), and the exit gas must contain no more than 0.2 mol % H 2 S 0.2\text{ mol}\%\text{ H}_2\text{S} 0.2 mol % H 2 ​ S ( y 2 = 0.002 y_2 = 0.002 y 2 ​ = 0.002 ). The total gas flow rate is 150 kmol/h 150\text{ kmol/h} 150 kmol/h . The water entering the column is pure ( x 2 = 0 x_2 = 0 x 2 ​ = 0 ). The equilibrium relationship is given by y ∗ = 1.6 x y^* = 1.6 x y ∗ = 1.6 x . Calculate:

The minimum water flow rate ( L min ⁡ L_{\min} L m i n ​ ) in kmol/h \text{kmol/h} kmol/h .

The operating water flow rate if the design is set at 1.3 1.3 1.3 times the minimum.

Solution:

Determine the maximum possible liquid concentration at the bottom of the column ( x 1 ∗ x_1^* x 1 ∗ ​ ), which would be in equilibrium with the entering gas ( y 1 = 0.040 y_1 = 0.040 y 1 ​ = 0.040 ): x 1 ∗ = y 1 m = 0.040 1.6 = 0.025 x_1^* = \frac{y_1}{m} = \frac{0.040}{1.6} = 0.025 x 1 ∗ ​ = m y 1 ​ ​ = 1.6 0.040 ​ = 0.025

Calculate the minimum liquid-to-gas flow rate ratio ( L / G ) min ⁡ (L/G)_{\min} ( L / G ) m i n ​ : ( L G ) min ⁡ = y 1 − y 2 x 1 ∗ − x 2 = 0.040 − 0.002 0.025 − 0 = 0.038 0.025 = 1.52 \left(\frac{L}{G}\right)_{\min} = \frac{y_1 - y_2}{x_1^* - x_2} = \frac{0.040 - 0.002}{0.025 - 0} = \frac{0.038}{0.025} = 1.52 ( G L ​ ) m i n ​ = x 1 ∗ ​ − x 2 ​ y 1 ​ − y 2 ​ ​ = 0.025 − 0 0.040 − 0.002 ​ = 0.025 0.038 ​ = 1.52

Multiply by the gas flow rate G = 150 kmol/h G = 150\text{ kmol/h} G = 150 kmol/h to find L min ⁡ L_{\min} L m i n ​ : L min ⁡ = 1.52 × 150 kmol/h = 228 kmol/h L_{\min} = 1.52 \times 150\text{ kmol/h} = 228\text{ kmol/h} L m i n ​ = 1.52 × 150 kmol/h = 228 kmol/h

Compute the operating liquid flow rate ( L L L ): L = 1.3 × L min ⁡ = 1.3 × 228 kmol/h = 296.4 kmol/h L = 1.3 \times L_{\min} = 1.3 \times 228\text{ kmol/h} = 296.4\text{ kmol/h} L = 1.3 × L m i n ​ = 1.3 × 228 kmol/h = 296.4 kmol/h

Thus, the minimum solvent rate is 228 kmol/h 228\text{ kmol/h} 228 kmol/h and the operating solvent rate is 296.4 kmol/h 296.4\text{ kmol/h} 296.4 kmol/h .