Study guide

7.2 Laws of Thermodynamics and Cyclic Processes

NCEES Fundamentals of Engineering FE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Mathematics

1.1 Analytic Geometry, Algebra, and Trigonometry 1.2 Calculus and Differential Equations 1.3 Numerical Methods and Measurement Error

2 Chapter 2: Probability and Statistics

2.1 Probability Distributions, Central Tendency, and Regression 2.2 Hypothesis Testing, ANOVA, and Statistical Quality Control

3 Chapter 3: Engineering Sciences

3.1 Mechanics and Dynamics 3.2 Electrical Circuits and Laws

4 Chapter 4: Materials Science

4.1 Material Properties and Compatibilities 4.2 Corrosion, Polymers, Ceramics, and Composites

5 Chapter 5: Chemistry and Biology

5.1 Stoichiometry, Analytical Chemistry, and Chemical Equilibrium 5.2 Organic Chemistry and Nomenclature 5.3 Biological Systems and Kinetics

6 Chapter 6: Fluid Mechanics and Dynamics

6.1 Fluid Properties, Dimensionless Numbers, and Flow Regimes 6.2 Bernoulli Equation and Mechanical Energy Balances 6.3 Flow Measurement and Fluid Machinery 6.4 Compressible and Non-Newtonian Flows

7 Chapter 7: Thermodynamics

7.1 Thermodynamic Properties, Ideal Gas, and State Equations 7.2 Laws of Thermodynamics and Cyclic Processes 7.3 Vapor-Liquid Equilibrium (VLE) and Phase Equilibrium 7.4 Chemical Equilibrium, Heats of Reaction, and Mixing

8 Chapter 8: Material and Energy Balances

8.1 Steady-State Material Balances 8.2 Unsteady-State Mass Balances 8.3 Steady-State Energy Balances 8.4 Unsteady-State Energy Balances

9 Chapter 9: Heat Transfer

9.1 Conduction, Convection, and Radiation Fundamentals 9.2 Heat Transfer Coefficients, Fouling, and Overall U 9.3 Heat Exchanger Design

10 Chapter 10: Mass Transfer and Separation

10.1 Diffusion Fundamentals 10.2 Gas Absorption, Stripping, and Liquid-Liquid Extraction 10.3 Distillation and McCabe-Thiele Method 10.4 Continuous Contact Methods, Membrane Separations, and Evaporative Operations

11 Chapter 11: Solids Handling

11.1 Particle Properties and Solid Processing 11.2 Solids Transportation and Storage

12 Chapter 12: Chemical Reaction Engineering

12.1 Reaction Kinetics and Performance Metrics 12.2 Ideal Reactor Design 12.3 Multiple Reactions, Catalysis, and Heterogeneous Kinetics

13 Chapter 13: Economics

13.1 Time Value of Money and Project Selection 13.2 Profitability Analysis, Depreciation, and Break-Even

14 Chapter 14: Process Design

14.1 Process Flowsheets and Instrumentation 14.2 Equipment Selection, Sizing, and Cost Estimation 14.3 Process Optimization, Sustainability, and Inherently Safer Design

15 Chapter 15: Process Control

15.1 Process Dynamics and Transfer Functions 15.2 Feedback Control Loops, PID Tuning, and Control Hardware

16 Chapter 16: Safety, Health, and Environment

16.1 Flammability, Toxicity, and Industrial Hygiene 16.2 Hazard Identification and Risk Analysis 16.3 Overpressure Relief, Reactivity Hazards, and Waste Regulations

17 Chapter 17: Ethics and Professional Practice

17.1 Professional Codes of Ethics and Public Welfare 17.2 Intellectual Property, Contracts, and Professional Liability

7.2 Laws of Thermodynamics and Cyclic Processes

Key Takeaways Explain This Topic AI

The First Law provides energy conservation constraints: delta U = Q - W for closed systems and mass-flow enthalpy balances for open systems.

The Second Law establishes entropy generation constraints: dS must be greater than or equal to dQ/T, dictating process feasibility.

Isentropic processes for ideal gases are governed by relationships combining pressure, temperature, and specific heat ratio k.

Thermodynamic cycles (Carnot, Rankine, Brayton, Vapor-Compression) model practical power-generation and refrigeration processes.

Last updated: July 2026

The First and Second Laws of Thermodynamics

The First Law of Thermodynamics is the principle of conservation of energy. For a closed system undergoing a change of state, the energy balance is: Δ U = Q − W \Delta U = Q - W Δ U = Q − W

where Δ U \Delta U Δ U is the change in internal energy, Q Q Q is the net heat transferred into the system, and W W W is the net work done by the system on its surroundings. For a steady-state, steady-flow open system, the energy balance is expressed in terms of enthalpy ( h h h ), velocity ( V V V ), and elevation ( z z z ) in the FE Reference Handbook: Q ˙ − W ˙ s = ∑ m ˙ o u t ( h + V 2 2 + g z ) o u t − ∑ m ˙ i n ( h + V 2 2 + g z ) i n \dot{Q} - \dot{W}_s = \sum \dot{m}_{out} \left(h + \frac{V^2}{2} + gz\right)_{out} - \sum \dot{m}_{in} \left(h + \frac{V^2}{2} + gz\right)_{in} Q ˙ ​ − W ˙ s ​ = ∑ m ˙ o u t ​ ( h + 2 V 2 ​ + g z ) o u t ​ − ∑ m ˙ in ​ ( h + 2 V 2 ​ + g z ) in ​

where W ˙ s \dot{W}_s W ˙ s ​ is shaft work. For pumps, compressors, and turbines, kinetic and potential energy changes are typically negligible, simplifying the balance to W ˙ s = m ˙ ( h i n − h o u t ) \dot{W}_s = \dot{m}(h_{in} - h_{out}) W ˙ s ​ = m ˙ ( h in ​ − h o u t ​ ) (assuming adiabatic operation).

The Second Law of Thermodynamics dictates the direction of natural processes. It asserts that the total entropy of an isolated system can never decrease over time. The change in entropy ( S S S ) for any process is: Δ S ≥ ∫ d Q T \Delta S \ge \int \frac{dQ}{T} Δ S ≥ ∫ T d Q ​

For a reversible process, this becomes d S = d Q r e v / T dS = dQ_{rev}/T d S = d Q re v ​ / T . For an ideal gas with constant specific heats, the change in specific entropy between two states is calculated using: s 2 − s 1 = C p ln ⁡ ( T 2 T 1 ) − R ln ⁡ ( P 2 P 1 ) = C v ln ⁡ ( T 2 T 1 ) + R ln ⁡ ( v 2 v 1 ) s_2 - s_1 = C_p \ln\left(\frac{T_2}{T_1}\right) - R \ln\left(\frac{P_2}{P_1}\right) = C_v \ln\left(\frac{T_2}{T_1}\right) + R \ln\left(\frac{v_2}{v_1}\right) s 2 ​ − s 1 ​ = C p ​ ln ( T 1 ​ T 2 ​ ​ ) − R ln ( P 1 ​ P 2 ​ ​ ) = C v ​ ln ( T 1 ​ T 2 ​ ​ ) + R ln ( v 1 ​ v 2 ​ ​ )

For an isentropic process (reversible and adiabatic), Δ s = 0 \Delta s = 0 Δ s = 0 . This leads to the isentropic relations for an ideal gas: T 2 T 1 = ( P 2 P 1 ) k − 1 k = ( v 1 v 2 ) k − 1 \frac{T_2}{T_1} = \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} = \left(\frac{v_1}{v_2}\right)^{k-1} T 1 ​ T 2 ​ ​ = ( P 1 ​ P 2 ​ ​ ) k k − 1 ​ = ( v 2 ​ v 1 ​ ​ ) k − 1

where k = C p / C v k = C_p / C_v k = C p ​ / C v ​ is the specific heat ratio.

Thermodynamic Processes

Let's summarize the work and heat relationships for an ideal gas undergoing various processes:

Isothermal ( T = constant T = \text{constant} T = constant ): Since internal energy of an ideal gas is a function of temperature only, Δ U = Δ H = 0 \Delta U = \Delta H = 0 Δ U = Δ H = 0 . The First Law yields Q = W = n R T ln ⁡ ( V 2 / V 1 ) = n R T ln ⁡ ( P 1 / P 2 ) Q = W = nRT \ln(V_2/V_1) = nRT \ln(P_1/P_2) Q = W = n RT ln ( V 2 ​ / V 1 ​ ) = n RT ln ( P 1 ​ / P 2 ​ ) .

Isobaric ( P = constant P = \text{constant} P = constant ): Work is W = P ( V 2 − V 1 ) = n R ( T 2 − T 1 ) W = P(V_2 - V_1) = nR(T_2 - T_1) W = P ( V 2 ​ − V 1 ​ ) = n R ( T 2 ​ − T 1 ​ ) . Heat transfer is Q = Δ H = n C p ( T 2 − T 1 ) Q = \Delta H = n C_p (T_2 - T_1) Q = Δ H = n C p ​ ( T 2 ​ − T 1 ​ ) .

Isochoric ( V = constant V = \text{constant} V = constant ): Since the volume is constant, boundary work W = 0 W = 0 W = 0 . Heat transfer is Q = Δ U = n C v ( T 2 − T 1 ) Q = \Delta U = n C_v (T_2 - T_1) Q = Δ U = n C v ​ ( T 2 ​ − T 1 ​ ) .

Isentropic ( S = constant S = \text{constant} S = constant , Q = 0 Q = 0 Q = 0 ): Work done by the gas is W = − Δ U = n C v ( T 1 − T 2 ) = P 1 V 1 − P 2 V 2 k − 1 W = -\Delta U = n C_v (T_1 - T_2) = \frac{P_1 V_1 - P_2 V_2}{k - 1} W = − Δ U = n C v ​ ( T 1 ​ − T 2 ​ ) = k − 1 P 1 ​ V 1 ​ − P 2 ​ V 2 ​ ​ .

Power and Refrigeration Cycles

Engineers use thermodynamic cycles to convert heat into work (power cycles) or to transfer heat from a cold region to a hot region (refrigeration and heat pump cycles).

The Carnot Cycle

The Carnot cycle represents the theoretical limit of thermodynamic efficiency. It consists of four reversible steps: isothermal expansion, isentropic expansion, isothermal compression, and isentropic compression.

Thermal Efficiency ( η Carnot \eta_{\text{Carnot}} η Carnot ​ ): For a power cycle operating between hot reservoir T H T_H T H ​ and cold reservoir T L T_L T L ​ : η Carnot = 1 − T L T H \eta_{\text{Carnot}} = 1 - \frac{T_L}{T_H} η Carnot ​ = 1 − T H ​ T L ​ ​

Coefficient of Performance (COP): For refrigeration (R) and heat pump (HP) cycles: C O P R , Carnot = T L T H − T L , C O P H P , Carnot = T H T H − T L COP_{R,\text{Carnot}} = \frac{T_L}{T_H - T_L}, \quad COP_{HP,\text{Carnot}} = \frac{T_H}{T_H - T_L} CO P R , Carnot ​ = T H ​ − T L ​ T L ​ ​ , CO P H P , Carnot ​ = T H ​ − T L ​ T H ​ ​

Note that all temperatures in these equations must be absolute (K or R).

The Rankine Cycle

The Rankine cycle is the model for steam power plants. It consists of:

1 → \to → 2 Isentropic Compression: Water is pressurized by a pump. Work input is w p = h 2 − h 1 ≈ v 1 ( P 2 − P 1 ) w_p = h_2 - h_1 \approx v_1(P_2 - P_1) w p ​ = h 2 ​ − h 1 ​ ≈ v 1 ​ ( P 2 ​ − P 1 ​ ) .

2 → \to → 3 Isobaric Heat Addition: High-pressure liquid is heated in a boiler to form superheated steam. Heat input is q i n = h 3 − h 2 q_{in} = h_3 - h_2 q in ​ = h 3 ​ − h 2 ​ .

3 → \to → 4 Isentropic Expansion: Steam expands through a turbine to generate power. Work output is w t = h 3 − h 4 w_t = h_3 - h_4 w t ​ = h 3 ​ − h 4 ​ .

4 → \to → 1 Isobaric Heat Rejection: Wet steam is condensed back to liquid in a condenser. Heat rejected is q o u t = h 4 − h 1 q_{out} = h_4 - h_1 q o u t ​ = h 4 ​ − h 1 ​ .

The net thermal efficiency is η thermal = w t − w p q i n \eta_{\text{thermal}} = \frac{w_t - w_p}{q_{in}} η thermal ​ = q in ​ w t ​ − w p ​ ​ .

The Brayton Cycle

The Brayton cycle is the ideal cycle for gas turbine engines. It operates on a gas (usually air) and consists of isentropic compression (pump/compressor), isobaric heat addition (combustor), isentropic expansion (turbine), and isobaric heat rejection. The efficiency depends on the pressure ratio r p = P 2 / P 1 r_p = P_2 / P_1 r p ​ = P 2 ​ / P 1 ​ : η Brayton = 1 − 1 r p ( k − 1 ) / k \eta_{\text{Brayton}} = 1 - \frac{1}{r_p^{(k-1)/k}} η Brayton ​ = 1 − r p ( k − 1 ) / k ​ 1 ​

Vapor-Compression Refrigeration Cycle

This is the standard cycle for household refrigerators and air conditioners. It consists of:

1 → \to → 2 Isentropic Compression: Low-pressure vapor is compressed to high pressure. w c = h 2 − h 1 w_c = h_2 - h_1 w c ​ = h 2 ​ − h 1 ​ .

2 → \to → 3 Isobaric Heat Rejection: Vapor condenses into high-pressure liquid. q o u t = h 2 − h 3 q_{out} = h_2 - h_3 q o u t ​ = h 2 ​ − h 3 ​ .

3 → \to → 4 Isenthalpic Expansion: Liquid is throttled through an expansion valve. This is a constant-enthalpy process: h 3 = h 4 h_3 = h_4 h 3 ​ = h 4 ​ .

4 → \to → 1 Isobaric Heat Addition: Liquid evaporates at low pressure, absorbing heat. q i n = h 1 − h 4 q_{in} = h_1 - h_4 q in ​ = h 1 ​ − h 4 ​ .

The COP is C O P R = h 1 − h 4 h 2 − h 1 COP_R = \frac{h_1 - h_4}{h_2 - h_1} CO P R ​ = h 2 ​ − h 1 ​ h 1 ​ − h 4 ​ ​ .

Worked Example: Carnot Refrigerant Analysis

A vapor-compression refrigerator operates on a Carnot cycle between a cold space at − 10 ∘ C -10^\circ\text{C} − 1 0 ∘ C and a hot reservoir at 35 ∘ C 35^\circ\text{C} 3 5 ∘ C . Determine the maximum coefficient of performance ( C O P R COP_R CO P R ​ ) and the minimum power input required to remove 5.0 kW 5.0\text{ kW} 5.0 kW of heat from the cold space.

Step 1: Convert temperatures to absolute scale (Kelvin). T L = − 10 + 273.15 = 263.15 K T_L = -10 + 273.15 = 263.15 \text{ K} T L ​ = − 10 + 273.15 = 263.15 K T H = 35 + 273.15 = 308.15 K T_H = 35 + 273.15 = 308.15 \text{ K} T H ​ = 35 + 273.15 = 308.15 K

Step 2: Calculate the Carnot Coefficient of Performance ( C O P R , Carnot COP_{R,\text{Carnot}} CO P R , Carnot ​ ). C O P R , Carnot = T L T H − T L = 263.15 308.15 − 263.15 = 263.15 45.0 ≈ 5.85 COP_{R,\text{Carnot}} = \frac{T_L}{T_H - T_L} = \frac{263.15}{308.15 - 263.15} = \frac{263.15}{45.0} \approx 5.85 CO P R , Carnot ​ = T H ​ − T L ​ T L ​ ​ = 308.15 − 263.15 263.15 ​ = 45.0 263.15 ​ ≈ 5.85

Step 3: Calculate the minimum power input ( W ˙ in \dot{W}_{\text{in}} W ˙ in ​ ). C O P R = Q ˙ L W ˙ in ⟹ W ˙ in = Q ˙ L C O P R COP_R = \frac{\dot{Q}_L}{\dot{W}_{\text{in}}} \implies \dot{W}_{\text{in}} = \frac{\dot{Q}_L}{COP_R} CO P R ​ = W ˙ in ​ Q ˙ ​ L ​ ​ ⟹ W ˙ in ​ = CO P R ​ Q ˙ ​ L ​ ​ W ˙ in = 5.0 kW 5.85 ≈ 0.855 kW = 855 W \dot{W}_{\text{in}} = \frac{5.0 \text{ kW}}{5.85} \approx 0.855 \text{ kW} = 855 \text{ W} W ˙ in ​ = 5.85 5.0 kW ​ ≈ 0.855 kW = 855 W

This represents the thermodynamic minimum work required. Any actual refrigerator operating between these temperatures will require more power because of irreversibilities (friction, pressure drops, non-isentropic compression).

Cycle Comparison Table

Cycle Working Fluid Key Component 1 (Compression) Key Component 2 (Heat In) Key Component 3 (Expansion) Key Component 4 (Heat Out)

  • Rankine Water/Steam Pump (isentropic) Boiler (isobaric) Turbine (isentropic) Condenser (isobaric)
  • Brayton Gas/Air Compressor (isentropic) Combustor (isobaric) Turbine (isentropic) Heat Exchanger (isobaric)

Vapor-Compression Refrigerant Compressor (isentropic) Condenser (isobaric) Throttling Valve (isenthalpic) Evaporator (isobaric)