Study guide

Groundwater: Darcy, Theis & Cooper-Jacob

FE Environmental Study Guide Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction, Mathematics & Ethics

Exam Format, NCEES CBT Logistics & Blueprint Map Calculus & Differential Equations Probability, Statistics & Regression Numerical Methods & Engineering Math Mathematics Applications for Environmental FE

2 Ethics, Economics & Materials

NCEES Model Rules & Engineering Ethics Professional Practice, Liability & Public Safety Engineering Economics: Time Value of Money Benefit-Cost, Replacement & Inflation Analysis Materials: Concrete, Corrosion & Polymers

3 Environmental Science & Chemistry

Geosynthetics & Environmental Materials Environmental Chemistry & Stoichiometry Water Chemistry: pH, Alkalinity & Hardness Microbiology, BOD Kinetics & Monod Growth Henry's Law & Phase Equilibrium for Air Quality

4 Risk Assessment & Water Resources

Environmental Science Applications EPA Four-Step Risk Assessment Paradigm Exposure, Dose, Hazard Quotient & Cancer Risk Hydrology & Rainfall-Runoff Analysis Open-Channel Flow & Manning Equation

5 Groundwater & Water Treatment

Groundwater: Darcy, Theis & Cooper-Jacob Streeter-Phelps & Water-Quality Modeling Water Treatment: Sedimentation & Filtration Disinfection, CT Rule & Chlorination Wastewater: Activated Sludge & BOD Removal

6 Advanced Treatment & Air Quality

Advanced Treatment: MBR, GAC & RO Sludge Handling & Water Reuse NAAQS, Criteria Pollutants, HAPs & AQI Gaussian Plume, Pasquill Stability & Effective Stack Height AP-42 Factors & Air Pollution Control Technologies

7 Air Permitting & Solid/Hazardous Waste

PSD, NSR, BACT, LAER, Title V & Offsets RCRA Lists, Characteristics & Generator Categories Subtitle D Landfill Design, Liners & Leachate CERCLA, UST, TCLP & Land Disposal Restrictions MSW Collection, Transfer, Composting, WTE & Recycling

8 Sustainability, EHS & Exam Day

LCA Stages, Carbon Footprint & Scope 1/2/3 Emissions LEED Credits, ISO 14001 EMS & Triple Bottom Line PELs, TLVs, Hierarchy of Controls & Confined Spaces EPCRA Reporting, TRI Form R, DOT Hazmat & RCRA Manifests Exam Format, NCEES CBT Logistics & Blueprint Map

Groundwater: Darcy, Theis & Cooper-Jacob

Key Takeaways Explain This Topic AI

Darcy's law Q = K i A relates discharge to hydraulic conductivity, hydraulic gradient, and cross-sectional area.

Hydraulic conductivity K depends on porous media grain size, porosity, and fluid viscosity — not the same as permeability.

Confined aquifers have artesian pressure; unconfined aquifers have a free water table.

Theis equation models transient drawdown in confined aquifers from a pumping well.

Cooper-Jacob approximates Theis at large time when u = r²S/(4Tt) is small.

Last updated: July 2026

Quick Answer: Steady flow → Darcy . Pump test drawdown → Theis (or Cooper-Jacob at late time). Know T = Kb (transmissivity) and S (storativity) for confined aquifers.

Groundwater supplies drinking water, receives septic and landfill leachate, and carries contaminant plumes. FE Environmental items test Darcy calculations and conceptual pumping-test interpretation.

Darcy's Law Q = K i A = K A h 1 − h 2 L Q = K \, i \, A = K \, A \, \frac{h_1 - h_2}{L} Q = K i A = K A L h 1 ​ − h 2 ​ ​

  • Symbol Meaning Typical units
  • Q Volumetric discharge m³/s, gpm
  • K Hydraulic conductivity m/s, gpd/ft²
  • i Hydraulic gradient ft/ft (dimensionless)
  • A Flow area perpendicular to flow ft², m²

Valid for laminar flow in saturated porous media (Reynolds < ~10 in granular media).

Worked example: Sand column A = 2 m²; L = 50 m; h₁ − h₂ = 2 m; K = 1×10⁻⁴ m/s. Q = 10 − 4 × 2 × 2 50 = 8 × 10 − 6 m 3 / s Q = 10^{-4} \times 2 \times \frac{2}{50} = 8 \times 10^{-6} \text{ m}^3/\text{s} Q = 1 0 − 4 × 2 × 50 2 ​ = 8 × 1 0 − 6 m 3 / s

Permeability vs. Hydraulic Conductivity

Intrinsic permeability k (darcy) depends on media only. K = k ρg/μ includes fluid properties. Temperature affects μ — warmer water slightly higher K.

Aquifer Types

  • Type Definition Key parameter
  • Confined Bounded above/below by aquitards Artesian head may rise above top
  • Unconfined Water table is upper boundary Specific yield for drainage
  • Leaky Partial confinement with leakage Leakance

Transmissivity T = K × b (confined aquifer thickness b). Storativity S (confined) is small (~10⁻⁵–10⁻³); specific yield Sy (unconfined) is larger (~0.1–0.3).

Steady Radial Flow to a Well (Confined, Thiem) Q = 2 π T ( h 2 − h 1 ) ln ⁡ ( r 2 / r 1 ) Q = \frac{2\pi T (h_2 - h_1)}{\ln(r_2/r_1)} Q = ln ( r 2 ​ / r 1 ​ ) 2 π T ( h 2 ​ − h 1 ​ ) ​

Drawdown s = h₀ − h at distance r. Used for equilibrium pumping tests.

Theis Equation (Transient)

Drawdown in confined aquifer from constant discharge Q: s ( r , t ) = Q 4 π T W ( u ) , u = r 2 S 4 T t s(r,t) = \frac{Q}{4\pi T} W(u), \quad u = \frac{r^2 S}{4 T t} s ( r , t ) = 4 π T Q ​ W ( u ) , u = 4 Tt r 2 S ​

W(u) is the well function — Handbook table or approximation.

Assumptions: Infinite aquifer, horizontal flow, constant T and S, fully penetrating well, instantaneous withdrawal from storage.

Cooper-Jacob Approximation

When u < ~0.01: s = 2.3 Q 4 π T log ⁡ 10 ⁣ ( 2.25 T t r 2 S ) s = \frac{2.3 Q}{4\pi T} \log_{10}\!\left(\frac{2.25 T t}{r^2 S}\right) s = 4 π T 2.3 Q ​ lo g 10 ​ ( r 2 S 2.25 Tt ​ )

Plot s vs. log t → straight line; slope Δs per log cycle gives T; intercept gives S.

Worked example (conceptual): Steeper drawdown curve at early time near well; flattening at distance — typical Theis behavior.

Unconfined Aquifer Notes

Delayed yield complicates early-time data — Jacob correction or numerical models. FE may stay conceptual: water table lowering increases gradient toward well.

Contaminant Transport (Brief)

Advection v = K i / n_e (effective porosity n_e). Dispersion spreads plume beyond mean advective front. Retardation R = 1 + ρ_b K_d / n_e slows solutes.

Well Design and Influence

Radius of influence R₀ where drawdown negligible — used in design estimates. Well efficiency losses (skin, partial penetration) raise drawdown in real wells.

FE Exam Checklist

Darcy: identify A, L, Δh, K.

Pumping: confined vs. unconfined; use T not K alone when Theis applies.

Match units — days vs. seconds in t ruins S.

Drawdown adds for multiple wells (superposition principle).

Exam trap: Using Sy in Theis confined equation — use storativity S , not specific yield.

Exam trap: Darcy velocity v = Q/A differs from seepage velocity v_s = Q/(n_e A).

Groundwater math pairs with water treatment when wells supply plants or when remediation extracts contaminated aquifers.

Specific Capacity and Well Tests

Specific capacity = Q/s (yield per unit drawdown) declines as wells clog or aquifer depletes. Step-drawdown tests separate aquifer loss from well loss (turbulence near screen).

Boundary Conditions

Image well theory handles constant head streams or no-flow boundaries — conceptual adjustment to Theis solutions near rivers and barriers.

Unconfined Delayed Yield

Early-time drawdown data may overestimate T if delayed yield not accounted for — late-time data more reliable for parameter fitting.

FE Problem Walkthrough

Given: Q = 0.05 m³/s, r = 30 m, t = 2 days, T = 0.01 m²/s, S = 0.0003 → compute u, lookup W(u), solve s. Units on t must match S and T (days vs. seconds — catastrophic if mixed).

Leaky Aquifer Concept

Leakance from confined aquifer through aquitard to adjacent aquifer adds water to pumped well — drawdown lower than ideal Theis predicts. Image wells model boundaries.

Well Field Interference

Multiple pumping wells within radius of influence superpose drawdowns — municipal well fields spaced to limit mutual interference during peak demand.

Full Theis Numeric Sketch

Q = 0.04 m³/s, r = 20 m, t = 1 day = 86400 s, T = 0.008 m²/s, S = 0.0002. u = r 2 S 4 T t = 400 × 0.0002 4 × 0.008 × 86400 = 2.9 × 10 − 5 u = \frac{r^2 S}{4Tt} = \frac{400 \times 0.0002}{4 \times 0.008 \times 86400} = 2.9 \times 10^{-5} u = 4 Tt r 2 S ​ = 4 × 0.008 × 86400 400 × 0.0002 ​ = 2.9 × 1 0 − 5

For small u, W(u) ≈ -0.5772 - ln(u) ≈ 10.0. Then s = Q 4 π T W ( u ) = 0.04 0.1005 × 10 ≈ 4.0 s = \frac{Q}{4\pi T} W(u) = \frac{0.04}{0.1005} \times 10 \approx 4.0 s = 4 π T Q ​ W ( u ) = 0.1005 0.04 ​ × 10 ≈ 4.0 m drawdown at 20 m after one day.

Thiem Equilibrium Example

Confined aquifer: T = 50 m²/day, h₀ = 30 m at R₀ = 500 m, well r_w = 0.3 m, Q = 200 m³/day. s w = Q 2 π T ln ⁡ R 0 r w = 200 314 ln ⁡ ( 1667 ) = 0.637 × 7.4 ≈ 4.7 m s_w = \frac{Q}{2\pi T}\ln\frac{R_0}{r_w} = \frac{200}{314}\ln(1667) = 0.637 \times 7.4 \approx 4.7\text{ m} s w ​ = 2 π T Q ​ ln r w ​ R 0 ​ ​ = 314 200 ​ ln ( 1667 ) = 0.637 × 7.4 ≈ 4.7 m

at the well (conceptual order-of-magnitude check).

Unit Conversion Trap

T in m²/day with t in seconds without conversion changes u by 86400² — always convert t to same time base as T before Theis.