Study guide
20.3 Attribute Control Charts: Defectives (p, np) and Defects (c, u)
FE Industrial and Systems Study Guide Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, CBT Strategy & Handbook Navigation
1.1 FE Industrial Exam Structure, CBT Logistics, and Pacing 1.2 Using the NCEES FE Reference Handbook and Approved Calculators
2 Chapter 2: Mathematics for Industrial Engineers
2.1 Analytic Geometry, Coordinate Systems, and Trigonometry 2.2 Calculus: Differential, Integral, and Series Approximations 2.3 Linear Algebra: Matrix Operations, Systems of Equations, and Vectors
3 Chapter 3: Engineering Sciences Core
3.1 Thermodynamics Fundamentals and Fluid Flow Principles 3.2 Statics, Dynamics, and Mechanics of Materials Core 3.3 Electrical Circuits, DC/AC Analysis, and Power in Industrial Systems
4 Chapter 4: Ethics and Professional Practice
4.1 NCEES Model Rules of Professional Conduct and Technical Society Ethics 4.2 Engineering Licensure, Public Welfare, and Professional Liability 4.3 Engineering Contracts, Intellectual Property, and Conflicts of Interest
5 Chapter 5: Engineering Economics
5.1 Time Value of Money, Discount Factors, and Equivalence 5.2 Evaluating Alternatives: Present Worth, Equivalent Annual Cost, and IRR 5.3 Incremental Rate of Return, Replacement Analysis, and Break-Even 5.4 Depreciation Methods, MACRS, Income Taxes, and Inflation
6 Chapter 6: Probability Foundations & Distributions
6.1 Basic Probability Concepts, Conditional Probability, and Bayes' Theorem 6.2 Discrete Probability Distributions 6.3 Continuous Probability Distributions
7 Chapter 7: Statistical Inference, Regression & Design of Experiments
7.1 Sampling Distributions, Central Limit Theorem, and Confidence Intervals 7.2 Hypothesis Testing: Means, Proportions, and Variances 7.3 Linear Regression, Correlation Analysis, and Design of Experiments (ANOVA)
8 Chapter 8: Data, Logic, Modeling & Linear Programming
8.1 Optimization Modeling: Decision Variables, Objectives, and Constraints 8.2 Linear Programming: Graphical Solutions and Simplex Fundamentals 8.3 Duality, Sensitivity Analysis, and Integer Linear Programming 8.4 Data, Logic Development, and Analytics
9 Chapter 9: Stochastic Models & Simulation
9.1 Queuing Theory: Little's Law, M/M/1, and Multi-Server Systems 9.2 Discrete-Time Markov Chains: Transition Matrices and Steady-State Probabilities 9.3 Discrete-Event Simulation Principles and Monte Carlo Modeling
10 Chapter 10: Engineering Management, Project Planning & Performance Measurement
10.1 Organizational Structure, Leadership, and Worker Motivation Theories 10.2 Project Management: WBS, Critical Path Method (CPM), PERT, and Crashing 10.3 Earned Value Management (EVM), Decision Trees, and Risk Preference 10.4 Performance Measurement: Productivity, KPIs, Wage Systems, and the Balanced Scorecard
11 Chapter 11: Manufacturing & Production Systems
11.1 Manufacturing Processes, Material Processing, and Tolerancing 11.2 Assembly Line Balancing, Takt Time, Cycle Time, and Throughput 11.3 Sustainable Manufacturing, Waste Minimization, and Life-Cycle Assessment
12 Chapter 12: Production Planning, Inventory Control & Sequencing
12.1 Demand Forecasting Methods and Forecast Error Tracking 12.2 Aggregate Planning, Master Production Scheduling (MPS), and MRP 12.3 Deterministic Inventory Models: EOQ, EPQ, and Safety Stock 12.4 Job Sequencing, Dispatching Rules, and Flow Shop Scheduling
13 Chapter 13: Lean Systems & Theory of Constraints
13.1 Lean Foundations: Value Stream Mapping, Seven Wastes, and 5S 13.2 Pull Systems, Kanban, Just-In-Time (JIT), and SMED Setup Reduction 13.3 Theory of Constraints: Bottleneck Identification and Drum-Buffer-Rope
14 Chapter 14: Facilities Planning & Material Handling
14.1 Facility Location Analysis: Qualitative Factor Rating and Centroid Method 14.2 Facility Layout Design and Flow Analysis 14.3 Material Handling Equipment, Warehousing, and AS/RS
15 Chapter 15: Supply Chain Design & Logistics
15.1 Supply Chain Network Architecture and Transportation Modes 15.2 Distribution Strategies, Cross-Docking, and Vehicle Routing 15.3 The Bullwhip Effect, Risk Pooling, and Supply Chain Coordination
16 Chapter 16: Human Factors & Cognitive Ergonomics
16.1 Cognitive Engineering, Human-Machine Interface, Displays, and Controls 16.2 Anthropometric Principles, Percentile Design, and Biomechanical Posture 16.3 Environmental Ergonomics: Industrial Noise, Lighting, and Heat Stress
17 Chapter 17: Physical Ergonomics & Workplace Safety
17.1 Physical Ergonomics: The NIOSH Manual Lifting Equation 17.2 Cumulative Trauma Disorders and Postural Assessment 17.3 Workplace Safety: OSHA Standards, Hazard Analysis, and Control Hierarchy
18 Chapter 18: Work Design & Measurement
18.1 Methods Engineering, Process Charting, and Principles of Motion Economy 18.2 Direct Stopwatch Time Study: Observed Time, Performance Rating, and Allowances 18.3 Predetermined Time Systems, Work Sampling, and Learning Curves
19 Chapter 19: Quality Management, Six Sigma & Analytical Tools
19.1 Quality Philosophies, Total Quality Management, and Cost of Quality 19.2 Six Sigma DMAIC Methodology and Quality Function Deployment 19.3 The Seven Basic Quality Tools, Root Cause Analysis, and Taguchi Loss Function
20 Chapter 20: Statistical Process Control
20.1 Statistical Process Control Principles, Variation, and Run Rules 20.2 Variable Control Charts: X-bar & R, X-bar & S, and Individual-Moving Range 20.3 Attribute Control Charts: Defectives (p, np) and Defects (c, u)
21 Chapter 21: Process Capability & Acceptance Sampling
21.1 Process Capability Indices and Defect Levels 21.2 Acceptance Sampling Concepts and Operating Characteristic Curves 21.3 Sampling Risks, AQL, LTPD, and Standard Sampling Plans
22 Chapter 22: Systems Engineering & Life-Cycle Management
22.1 The Systems Engineering V-Model, Stakeholder Requirements, and Functional Architecture 22.2 Configuration Management, Interface Control, and Verification & Validation 22.3 Life-Cycle Costing, Maintainability, and System Availability
23 Chapter 23: Reliability Engineering & Risk Analysis
23.1 Reliability Mathematics, Hazard Rates, and the Bathtub Curve 23.2 System Reliability Configurations: Series, Parallel, and k-out-of-n Systems 23.3 Failure Modes and Effects Analysis and Fault Tree Analysis
20.3 Attribute Control Charts: Defectives (p, np) and Defects (c, u)
Key Takeaways Explain This Topic AI
Attribute control charts classify inspection data into two distinct statistical distributions: nonconforming units / defectives governed by the Binomial distribution (p and np charts) and nonconformities / defects per unit governed by the Poisson distribution (c and u charts).
A p-chart tracks the fraction nonconforming and supports variable or constant sample sizes n, whereas the np-chart tracks the integer count of defective items and strictly mandates a CONSTANT subgroup sample size n.
A c-chart monitors the total count of defects across a single constant inspection unit, whereas a u-chart monitors the defect rate per unit (u = c / n) and accommodates varying inspection sample sizes or continuous inspection areas.
When calculating lower control limits for attribute charts, any negative mathematical result must be truncated to zero (LCL = max(0, calculated value)) because physical counts and proportions cannot be negative.
When subgroup sample sizes vary on a p-chart, the baseline center line p_bar must be computed as total defectives divided by total inspected units (Sigma d_i / Sigma n_i), NOT as the unweighted arithmetic average of subgroup percentages.
Last updated: September 2026
Attribute control charts evaluate qualitative characteristics that are counted rather than measured on a continuous dimensional scale. Attribute data arises when products are classified into discrete binary states (e.g., conforming vs. nonconforming, pass vs. fail, functional vs. inoperable) or when surface blemishes, solder bridges, or packaging flaws are tallied across an inspection unit. While attribute charts require larger sample sizes than variable charts to achieve equivalent statistical power, they offer tremendous administrative advantages: inspection is often rapid, non-destructive, inexpensive (e.g., go/no-go plug gauges or automated vision sensors), and capable of summarizing complex multi-defect assemblies into a single metric.
1. Classification of Attribute Data: Defectives vs. Defects
The single most critical conceptual hurdle on the FE exam is distinguishing between nonconforming units (defectives) and nonconformities (defects) : Attribute Data Taxonomy
- │
- ┌──────────────────────┴──────────────────────┐
- ▼ ▼
- DEFECTIVE ITEM DEFECT COUNT
- (Nonconforming Unit) (Nonconformity)
- ───────────────────── ─────────────────
- The ENTIRE unit is rejected • Specific flaw, scratch, or blemish
- Binary: Conforming vs Nonconforming • Multiple flaws can reside on 1 unit
- Statistical Model: BINOMIAL • Statistical Model: POISSON
- Sample Size: n items inspected • Sample Size: Inspection area / volume
- │ │
- ┌────┴────┐ ┌────┴────┐
- ▼ ▼ ▼ ▼
- p-Chart np-Chart c-Chart u-Chart
- Fraction Count Count Rate
- Defective Defective Defects Defects/Unit
- (n varies (n CONSTANT) (Unit (Unit
- or fixed) CONSTANT) varies)
- Defectives (Nonconforming Units) — Binomial Distribution
An item is either conforming (acceptable) or nonconforming (defective). A smartphone either powers on or it does not; a sealed hydraulic fitting either leaks or holds pressure. Regardless of whether a part has 1 flaw or 10 flaws, it counts as exactly one defective item .
Governing Distribution : Binomial distribution with parameters n n n (sample size) and p p p (probability of nonconformance).
Applicable Charts : p p p -chart (fraction nonconforming) and n p np n p -chart (number of nonconforming items).
Defects (Nonconformities) — Poisson Distribution
A defect is a specific physical imperfection or departure from a quality standard. An automobile door panel may have two paint pinholes, one scratch, and one dent: that is four defects on a single unit. A circuit board may have five cold solder joints but still pass functional testing.
Governing Distribution : Poisson distribution with parameter λ \lambda λ (average count of independent, rare events per inspection area of opportunity).
Applicable Charts : c c c -chart (count of defects per constant unit) and u u u -chart (defects per unit for variable inspection sizes).
Classification Characteristic Statistical Model Control Charts Operational Examples
Defective (Nonconforming Item) Unit is classified binary Pass / Fail Binomial ( n , p n, p n , p ) p p p -Chart (proportion); n p np n p -Chart (count) Cracked turbine blades, blown fuses, leaking syringes
Defect (Nonconformity) Tally of flaws per inspection unit Poisson ( λ \lambda λ ) c c c -Chart (constant unit); u u u -Chart (variable unit) Solder voids per board, weave blemishes per 100 m 2 100\text{ m}^2 100 m 2 , paint scratches
2. The p p p -Chart (Fraction Nonconforming)
The p p p -chart monitors the proportion (or fraction) of nonconforming items in a sample. It is the most versatile attribute chart because it accommodates both constant and variable subgroup sample sizes n i n_i n i .
Fundamental Formulas
For m m m subgroups, where subgroup i i i contains n i n_i n i inspected items and d i d_i d i nonconforming items:
Fraction Nonconforming for Subgroup i i i : p i = d i n i p_i = \frac{d_i}{n_i} p i = n i d i
Center Line ( p ˉ \bar{p} p ˉ ) : The overall weighted historical average fraction nonconforming: p ˉ = ∑ i = 1 m d i ∑ i = 1 m n i = Total Defective Items Inspected Total Items Inspected \bar{p} = \frac{\sum_{i=1}^m d_i}{\sum_{i=1}^m n_i} = \frac{\text{Total Defective Items Inspected}}{\text{Total Items Inspected}} p ˉ = ∑ i = 1 m n i ∑ i = 1 m d i = Total Items Inspected Total Defective Items Inspected
CRITICAL EXAM TRAP : If sample sizes n i n_i n i vary across subgroups, p ˉ \bar{p} p ˉ must never be calculated as the simple arithmetic average of the subgroup proportions ( 1 m ∑ p i \frac{1}{m}\sum p_i m 1 ∑ p i ). Doing so treats small batches with equal weight to large batches, introducing mathematical bias!
Control Limits for Constant Sample Size n n n
Under the Binomial distribution, the variance of sample proportion p p p is σ p 2 = p ( 1 − p ) n \sigma_p^2 = \frac{p(1-p)}{n} σ p 2 = n p ( 1 − p ) . Using historical p ˉ \bar{p} p ˉ : C L p = p ˉ CL_p = \bar{p} C L p = p ˉ U C L p = p ˉ + 3 p ˉ ( 1 − p ˉ ) n UCL_p = \bar{p} + 3 \sqrt{\frac{\bar{p}(1 - \bar{p})}{n}} U C L p = p ˉ + 3 n p ˉ ( 1 − p ˉ ) L C L p = max ( 0 , p ˉ − 3 p ˉ ( 1 − p ˉ ) n ) LCL_p = \max\left(0, \; \bar{p} - 3 \sqrt{\frac{\bar{p}(1 - \bar{p})}{n}}\right) L C L p = max ( 0 , p ˉ − 3 n p ˉ ( 1 − p ˉ ) )
Mandatory Truncation Rule : If the mathematical calculation yields L C L p < 0 LCL_p < 0 L C L p < 0 , the Lower Control Limit is set to L C L = 0 LCL = 0 L C L = 0 . A negative proportion of defectives is physically impossible!
Handling Variable Sample Sizes on a p p p -Chart
When subgroup size n i n_i n i varies from batch to batch:
Variable Control Limits (Exact Method) : Calculate separate control limits for each individual subgroup i i i based on its specific n i n_i n i : U C L i = p ˉ + 3 p ˉ ( 1 − p ˉ ) n i , L C L i = max ( 0 , p ˉ − 3 p ˉ ( 1 − p ˉ ) n i ) UCL_i = \bar{p} + 3 \sqrt{\frac{\bar{p}(1 - \bar{p})}{n_i}}, \qquad LCL_i = \max\left(0, \; \bar{p} - 3 \sqrt{\frac{\bar{p}(1 - \bar{p})}{n_i}}\right) U C L i = p ˉ + 3 n i p ˉ ( 1 − p ˉ ) , L C L i = max 0 , p ˉ − 3 n i p ˉ ( 1 − p ˉ ) Notice : Larger sample sizes produce narrower control bands; smaller sample sizes produce wider control bands.
Average Sample Size Method ( n ˉ \bar{n} n ˉ ) : If individual sample sizes vary by no more than ± 25 % \pm 25\% ± 25% from the average sample size n ˉ = 1 m ∑ n i \bar{n} = \frac{1}{m}\sum n_i n ˉ = m 1 ∑ n i , a single set of constant control limits may be computed using n ˉ \bar{n} n ˉ .
3. The n p np n p -Chart (Number of Nonconforming Items)
The n p np n p -chart monitors the raw count of defective items ( d i d_i d i ) rather than the fraction p i p_i p i .
The Mandatory Operational Rule for n p np n p -Charts
STRICT CONSTRAINT : The n p np n p -chart requires a strictly CONSTANT sample size n n n across all subgroups ( n 1 = n 2 = ⋯ = n n_1 = n_2 = \dots = n n 1 = n 2 = ⋯ = n ). If sample size varies, the n p np n p -chart cannot be used!
Fundamental Formulas
For constant sample size n n n and baseline fraction nonconforming p ˉ \bar{p} p ˉ :
Center Line ( C L n p CL_{np} C L n p ) : C L n p = n p ˉ CL_{np} = n\bar{p} C L n p = n p ˉ
Control Limits : U C L n p = n p ˉ + 3 n p ˉ ( 1 − p ˉ ) UCL_{np} = n\bar{p} + 3 \sqrt{n\bar{p}(1 - \bar{p})} U C L n p = n p ˉ + 3 n p ˉ ( 1 − p ˉ ) L C L n p = max ( 0 , n p ˉ − 3 n p ˉ ( 1 − p ˉ ) ) LCL_{np} = \max\left(0, \; n\bar{p} - 3 \sqrt{n\bar{p}(1 - \bar{p})}\right) L C L n p = max ( 0 , n p ˉ − 3 n p ˉ ( 1 − p ˉ ) )
Why Use an n p np n p -Chart over a p p p -Chart?
On factory production floors, line operators prefer the n p np n p -chart because it eliminates division. If n = 100 n = 100 n = 100 stamping parts are pulled, the operator simply counts the defective parts (e.g., 4 parts) and plots the integer 4 directly on the chart without calculating 4 / 100 = 0.04 4/100 = 0.04 4/100 = 0.04 .
4. The c c c -Chart (Defects per Constant Inspection Unit)
The c c c -chart monitors the count of nonconformities (defects) observed in a single, standardized inspection unit of fixed size.
The Mandatory Operational Rule for c c c -Charts
STRICT CONSTRAINT : The area of opportunity (inspection unit size) must be strictly CONSTANT across all samples (e.g., exactly 1 refrigerator, exactly 50 m 2 50\text{ m}^2 50 m 2 of fabric, exactly 1 complex circuit board).
Fundamental Formulas
Under the Poisson distribution, the mean equals the variance ( λ = σ 2 = c \lambda = \sigma^2 = c λ = σ 2 = c ). Therefore, the standard deviation of defect count is σ c = c \sigma_c = \sqrt{c} σ c = c .
For m m m inspected units, where unit i i i exhibits c i c_i c i defects:
Center Line ( c ˉ \bar{c} c ˉ ) : C L c = c ˉ = 1 m ∑ i = 1 m c i CL_c = \bar{c} = \frac{1}{m} \sum_{i=1}^m c_i C L c = c ˉ = m 1 i = 1 ∑ m c i
Control Limits : U C L c = c ˉ + 3 c ˉ UCL_c = \bar{c} + 3 \sqrt{\bar{c}} U C L c = c ˉ + 3 c ˉ L C L c = max ( 0 , c ˉ − 3 c ˉ ) LCL_c = \max\left(0, \; \bar{c} - 3 \sqrt{\bar{c}}\right) L C L c = max ( 0 , c ˉ − 3 c ˉ )
If c ˉ − 3 c ˉ < 0 \bar{c} - 3\sqrt{\bar{c}} < 0 c ˉ − 3 c ˉ < 0 , truncate L C L c LCL_c L C L c to 0 .
5. The u u u -Chart (Defects per Unit for Variable Inspection Sizes)
When the inspection unit size varies from sample to sample (e.g., inspecting 5 aircraft wings on Monday, 3 on Tuesday; or inspecting continuous rolls of sheet steel where roll lengths vary), the c c c -chart is invalid. The engineer must use a u u u -chart , which monitors the average defect rate per standardized inspection unit .
Fundamental Formulas
For subgroup i i i with n i n_i n i inspection units and c i c_i c i total defects:
Defects per Unit for Subgroup i i i : u i = c i n i u_i = \frac{c_i}{n_i} u i = n i c i
Center Line ( u ˉ \bar{u} u ˉ ) : The overall weighted defect rate: u ˉ = ∑ i = 1 m c i ∑ i = 1 m n i = Total Defects Counted Total Inspection Units Examined \bar{u} = \frac{\sum_{i=1}^m c_i}{\sum_{i=1}^m n_i} = \frac{\text{Total Defects Counted}}{\text{Total Inspection Units Examined}} u ˉ = ∑ i = 1 m n i ∑ i = 1 m c i = Total Inspection Units Examined Total Defects Counted
Control Limits for Subgroup i i i (Variable Limits) : C L u = u ˉ CL_u = \bar{u} C L u = u ˉ U C L u , i = u ˉ + 3 u ˉ n i UCL_{u, i} = \bar{u} + 3 \sqrt{\frac{\bar{u}}{n_i}} U C L u , i = u ˉ + 3 n i u ˉ L C L u , i = max ( 0 , u ˉ − 3 u ˉ n i ) LCL_{u, i} = \max\left(0, \; \bar{u} - 3 \sqrt{\frac{\bar{u}}{n_i}}\right) L C L u , i = max ( 0 , u ˉ − 3 n i u ˉ )
If sample size is constant ( n i = n n_i = n n i = n ), the control limits remain fixed across all subgroups.
6. Master Control Chart Selection Guide
The following decision logic guarantees selecting the correct chart on the FE exam: Master Chart Selection Decision Tree
What type of data do you have?
- │
- ┌──────────────────────┴──────────────────────┐
- ▼ ▼
- VARIABLE (Continuous) ATTRIBUTE (Discrete)
- (mm, kg, MPa, cP) (Good/Bad, Flaw Counts)
- │ │
What is sample size n? What are you counting?
- ┌─────┼─────┐ ┌─────────────┴─────────────┐
- ▼ ▼ ▼ ▼ ▼
- n = 1 2<=n<=9 n>=10 DEFECTIVES DEFECTS
- │ │ │ (Items Rejected) (Flaw Counts)
- I-MR X-R X-S │ │
Is n constant? Is area constant?
- ┌───┴───┐ ┌───┴───┐
- ▼ ▼ ▼ ▼
- CONST VARIES CONST VARIES
- │ │ │ │
- np p c u
- (or p) (or u)
Quality Characteristic Unit of Measurement Sample Size ( n n n ) Underlying Distribution NCEES Chart
Continuous Dimension Length, weight, torque, pressure n = 1 n = 1 n = 1 Normal ( n = 1 n=1 n = 1 ) I − M R I-MR I − MR
Continuous Dimension Dimensions, thickness, diameter 2 ≤ n ≤ 9 2 \le n \le 9 2 ≤ n ≤ 9 Normal (Central Limit) X ˉ \bar{X} X ˉ & R R R
- Continuous Dimension High-volume automated sensing n ≥ 10 n \ge 10 n ≥ 10 Normal X ˉ \bar{X} X ˉ & S S S
- Fraction Defective Fraction nonconforming units Variable or Constant Binomial p p p -Chart
- Count of Defectives Integer count of rejected parts Strictly Constant Binomial n p np n p -Chart
- Count of Defects Flaws, scratches, blemishes Strictly Constant Poisson c c c -Chart
- Defect Rate per Unit Flaws per m 2 m^2 m 2 , voids per board Variable or Constant Poisson u u u -Chart
- 7. Step-by-Step Worked Engineering Calculations
- Worked Example 20.3.1: p p p -Chart and n p np n p -Chart with Lower Limit Truncation
Problem Statement : An automated optical inspection (AOI) station evaluates surface-mount PCB assemblies for component misalignment. A quality engineer inspects m = 20 m = 20 m = 20 production lots, each consisting of a constant sample size of n = 250 n = 250 n = 250 boards. Across all 20 lots, a total of 150 defective boards are identified.
Calculate the center line p ˉ \bar{p} p ˉ for the p p p -chart.
Compute the 3-sigma Upper and Lower Control Limits for the p p p -chart.
Compute the Center Line and 3-sigma Control Limits if the data were plotted on an n p np n p -chart.
If Lot 12 exhibits 18 defective boards, evaluate whether this lot represents an out-of-control condition on both charts.
Solution :
- Step 1: Compute Center Line for p p p -Chart
- Total defective boards: ∑ d i = 150 \sum d_i = 150 ∑ d i = 150
Total boards inspected: ∑ n i = 20 × 250 = 5 , 000 \sum n_i = 20 \times 250 = 5,000 ∑ n i = 20 × 250 = 5 , 000 p ˉ = 150 5 , 000 = 0.030 ( 3.0 % nonconforming ) \bar{p} = \frac{150}{5,000} = 0.030 \quad (3.0\% \text{ nonconforming}) p ˉ = 5 , 000 150 = 0.030 ( 3.0% nonconforming )
Step 2: Calculate p p p -Chart Control Limits
Standard error of sample proportion: σ p = p ˉ ( 1 − p ˉ ) n = 0.030 ( 1 − 0.030 ) 250 = 0.030 ( 0.970 ) 250 = 0.0291 250 = 0.0001164 ≈ 0.010789 \sigma_p = \sqrt{\frac{\bar{p}(1 - \bar{p})}{n}} = \sqrt{\frac{0.030(1 - 0.030)}{250}} = \sqrt{\frac{0.030(0.970)}{250}} = \sqrt{\frac{0.0291}{250}} = \sqrt{0.0001164} \approx 0.010789 σ p = n p ˉ ( 1 − p ˉ ) = 250 0.030 ( 1 − 0.030 ) = 250 0.030 ( 0.970 ) = 250 0.0291 = 0.0001164 ≈ 0.010789
3-sigma margin: 3 σ p = 3 ( 0.010789 ) = 0.032367 ≈ 0.0324 3\sigma_p = 3(0.010789) = 0.032367 \approx 0.0324 3 σ p = 3 ( 0.010789 ) = 0.032367 ≈ 0.0324
Control Limits: C L p = p ˉ = 0.0300 CL_p = \bar{p} = 0.0300 C L p = p ˉ = 0.0300 U C L p = p ˉ + 3 σ p = 0.0300 + 0.0324 = 0.0624 ( 6.24 % ) UCL_p = \bar{p} + 3\sigma_p = 0.0300 + 0.0324 = 0.0624 \quad (6.24\%) U C L p = p ˉ + 3 σ p = 0.0300 + 0.0324 = 0.0624 ( 6.24% ) L C L p = p ˉ − 3 σ p = 0.0300 − 0.0324 = − 0.0024 LCL_p = \bar{p} - 3\sigma_p = 0.0300 - 0.0324 = -0.0024 L C L p = p ˉ − 3 σ p = 0.0300 − 0.0324 = − 0.0024
Applying the Mandatory Truncation Rule: Because L C L p < 0 LCL_p < 0 L C L p < 0 , set L C L p = 0.000 LCL_p = 0.000 L C L p = 0.000 .
Step 3: Calculate n p np n p -Chart Limits Because sample size is constant ( n = 250 n = 250 n = 250 ):
Center Line: C L n p = n p ˉ = 250 ( 0.030 ) = 7.50 CL_{np} = n\bar{p} = 250(0.030) = 7.50 C L n p = n p ˉ = 250 ( 0.030 ) = 7.50 defectives
Standard deviation: σ n p = n p ˉ ( 1 − p ˉ ) = 250 ( 0.030 ) ( 0.970 ) = 7.275 ≈ 2.6972 \sigma_{np} = \sqrt{n\bar{p}(1 - \bar{p})} = \sqrt{250(0.030)(0.970)} = \sqrt{7.275} \approx 2.6972 σ n p = n p ˉ ( 1 − p ˉ ) = 250 ( 0.030 ) ( 0.970 ) = 7.275 ≈ 2.6972
3-sigma margin: 3 σ n p = 3 ( 2.6972 ) = 8.0916 3\sigma_{np} = 3(2.6972) = 8.0916 3 σ n p = 3 ( 2.6972 ) = 8.0916
Control Limits: U C L n p = 7.50 + 8.0916 = 15.59 defectives UCL_{np} = 7.50 + 8.0916 = 15.59 \text{ defectives} U C L n p = 7.50 + 8.0916 = 15.59 defectives L C L n p = max ( 0 , 7.50 − 8.0916 ) = max ( 0 , − 0.59 ) = 0.00 defectives LCL_{np} = \max(0, \; 7.50 - 8.0916) = \max(0, -0.59) = 0.00 \text{ defectives} L C L n p = max ( 0 , 7.50 − 8.0916 ) = max ( 0 , − 0.59 ) = 0.00 defectives
Step 4: Evaluate Lot 12
For Lot 12: d 12 = 18 d_{12} = 18 d 12 = 18 defectives.
On the n p np n p -chart: d 12 = 18 > U C L n p ( 15.59 ) d_{12} = 18 > UCL_{np} (15.59) d 12 = 18 > U C L n p ( 15.59 ) . Out of control!
On the p p p -chart: p 12 = 18 250 = 0.0720 p_{12} = \frac{18}{250} = 0.0720 p 12 = 250 18 = 0.0720 . Since p 12 = 0.0720 > U C L p ( 0.0624 ) p_{12} = 0.0720 > UCL_p (0.0624) p 12 = 0.0720 > U C L p ( 0.0624 ) . Out of control!
Conclusion : Both charts provide identical statistical conclusions. Lot 12 indicates a special-cause disturbance (e.g., feeder misalignment or solder paste stencil blockage) that must be investigated.
Worked Example 20.3.2: c c c -Chart vs. u u u -Chart with Variable Inspection Units
Problem Statement : An industrial coating facility inspects newly electroplated steel panels for surface pitting defects. Over five consecutive shifts, inspectors record the total number of pitting defects found across varying numbers of standard panels inspected:
- Shift ( i i i ) Panels Inspected ( n i n_i n i ) Total Defects Counted ( c i c_i c i )
- 1 10 18
- 2 15 24
- 3 8 20
- 4 20 32
- 5 12 16
Explain why a c c c -chart is mathematically invalid for this operational scenario.
Calculate the center line u ˉ \bar{u} u ˉ for the appropriate u u u -chart.
Compute the specific Upper and Lower Control Limits for Shift 3 ( n 3 = 8 n_3 = 8 n 3 = 8 panels) and Shift 4 ( n 4 = 20 n_4 = 20 n 4 = 20 panels).
Evaluate whether Shift 3 ( c 3 = 20 c_3 = 20 c 3 = 20 defects) represents an out-of-control condition.
Solution :
Step 1: Chart Justification The data records nonconformities (defects), which follow a Poisson model. However, the sample size varies from shift to shift ( n i n_i n i ranges from 8 to 20 panels). A c c c -chart strictly requires a constant area of opportunity ( n i = constant n_i = \text{constant} n i = constant ). Plotting raw counts when sample size varies would cause large batches to trigger false alarms simply due to higher inspection volume. Therefore, a u u u -chart (defects per unit) must be used.
Step 2: Calculate Center Line u ˉ \bar{u} u ˉ
Total defects counted: ∑ c i = 18 + 24 + 20 + 32 + 16 = 110 \sum c_i = 18 + 24 + 20 + 32 + 16 = 110 ∑ c i = 18 + 24 + 20 + 32 + 16 = 110 defects
Total panels inspected: ∑ n i = 10 + 15 + 8 + 20 + 12 = 65 \sum n_i = 10 + 15 + 8 + 20 + 12 = 65 ∑ n i = 10 + 15 + 8 + 20 + 12 = 65 panels u ˉ = 110 65 = 1.6923 ≈ 1.692 defects per panel \bar{u} = \frac{110}{65} = 1.6923 \approx 1.692 \text{ defects per panel} u ˉ = 65 110 = 1.6923 ≈ 1.692 defects per panel
Step 3: Calculate Control Limits for Shifts 3 and 4 For Shift 3 ( n 3 = 8 n_3 = 8 n 3 = 8 panels) :
Standard error: σ u , 3 = u ˉ n 3 = 1.6923 8 = 0.21154 ≈ 0.4599 \sigma_{u, 3} = \sqrt{\frac{\bar{u}}{n_3}} = \sqrt{\frac{1.6923}{8}} = \sqrt{0.21154} \approx 0.4599 σ u , 3 = n 3 u ˉ = 8 1.6923 = 0.21154 ≈ 0.4599
Limits: U C L u , 3 = 1.6923 + 3 ( 0.4599 ) = 1.6923 + 1.3798 = 3.072 defects/panel UCL_{u, 3} = 1.6923 + 3(0.4599) = 1.6923 + 1.3798 = 3.072 \text{ defects/panel} U C L u , 3 = 1.6923 + 3 ( 0.4599 ) = 1.6923 + 1.3798 = 3.072 defects/panel L C L u , 3 = max ( 0 , 1.6923 − 1.3798 ) = 0.313 defects/panel LCL_{u, 3} = \max(0, \; 1.6923 - 1.3798) = 0.313 \text{ defects/panel} L C L u , 3 = max ( 0 , 1.6923 − 1.3798 ) = 0.313 defects/panel
For Shift 4 ( n 4 = 20 n_4 = 20 n 4 = 20 panels) :
Standard error: σ u , 4 = u ˉ n 4 = 1.6923 20 = 0.08462 ≈ 0.2909 \sigma_{u, 4} = \sqrt{\frac{\bar{u}}{n_4}} = \sqrt{\frac{1.6923}{20}} = \sqrt{0.08462} \approx 0.2909 σ u , 4 = n 4 u ˉ = 20 1.6923 = 0.08462 ≈ 0.2909
Limits: U C L u , 4 = 1.6923 + 3 ( 0.2909 ) = 1.6923 + 0.8727 = 2.565 defects/panel UCL_{u, 4} = 1.6923 + 3(0.2909) = 1.6923 + 0.8727 = 2.565 \text{ defects/panel} U C L u , 4 = 1.6923 + 3 ( 0.2909 ) = 1.6923 + 0.8727 = 2.565 defects/panel L C L u , 4 = max ( 0 , 1.6923 − 0.8727 ) = 0.820 defects/panel LCL_{u, 4} = \max(0, \; 1.6923 - 0.8727) = 0.820 \text{ defects/panel} L C L u , 4 = max ( 0 , 1.6923 − 0.8727 ) = 0.820 defects/panel
(Notice: For n = 20 n = 20 n = 20 , the control limits are significantly tighter than for n = 8 n = 8 n = 8 ).
Step 4: Evaluate Shift 3
For Shift 3, the observed defect rate per panel is: u 3 = c 3 n 3 = 20 8 = 2.500 defects per panel u_3 = \frac{c_3}{n_3} = \frac{20}{8} = 2.500 \text{ defects per panel} u 3 = n 3 c 3 = 8 20 = 2.500 defects per panel
Comparing to Shift 3 control limits: L C L u , 3 ( 0.313 ) ≤ u 3 ( 2.500 ) ≤ U C L u , 3 ( 3.072 ) LCL_{u, 3} (0.313) \le u_3 (2.500) \le UCL_{u, 3} (3.072) L C L u , 3 ( 0.313 ) ≤ u 3 ( 2.500 ) ≤ U C L u , 3 ( 3.072 )
Conclusion : Shift 3 is in statistical control . Even though 20 defects appeared high in raw count, when standardized against the small sample size ( n = 8 n = 8 n = 8 ), the rate of 2.500 defects/panel remains within 3-sigma random variation.
8. NCEES Reference Handbook Tips & Realistic Exam Traps
Defect vs. Defective Trap : Always ask: Can an item have more than one of these flaws and still be one item? If yes, it is a defect ( c c c or u u u chart). If the item is simply rejected as bad or accepted as good, it is a defective ( p p p or n p np n p chart).
Mandatory LCL Truncation : Whenever an attribute control chart formula generates a negative lower control limit, you must truncate it to zero ( L C L = 0 LCL = 0 L C L = 0 ). NCEES exam questions frequently include the raw negative number as an attractive distractor!
Weighted Average for p ˉ \bar{p} p ˉ and u ˉ \bar{u} u ˉ : If an exam problem presents varying sample sizes, never take the simple average of the percentages. You must sum all defectives (or defects) and divide by the sum of all inspected units: p ˉ = ∑ d i ∑ n i , u ˉ = ∑ c i ∑ n i \bar{p} = \frac{\sum d_i}{\sum n_i}, \qquad \bar{u} = \frac{\sum c_i}{\sum n_i} p ˉ = ∑ n i ∑ d i , u ˉ = ∑ n i ∑ c i
When n n n Varies, n p np n p and c c c are Banned : If subgroup sizes fluctuate, you cannot use an n p np n p -chart or a c c c -chart. You must select a p p p -chart (with variable limits or n ˉ \bar{n} n ˉ ) or a u u u -chart.